• 제목/요약/키워드: Valve performance

검색결과 1,244건 처리시간 0.03초

반능동가변형 주퇴복좌기의 설계 및 제어

  • 김동환;최문철;이규섭
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.213-217
    • /
    • 1997
  • The semi-active recoil system provides automatic hydraulic pressure and recoil length by an exteral impulse compared with the conventional recoil system. We developed the proto type of recoil system and validated the performance through simulation and experiment. The main issue of the system is how to adjust pressure and length simultaneously. The system consists of external pressure control valve and flow control valve outside of cylinder. The pressure control valve control the cylinder pressure and recoil length. The controlled system enhances the control performance.

Measurement of Fluid Film Thickness on the Valve Plate in Oil Hydraulic Axial Piston rumps (I) - Bearing Pad Effects -

  • Kim, Jong-Ki;Jung, Jae-Youn
    • Journal of Mechanical Science and Technology
    • /
    • 제17권2호
    • /
    • pp.246-253
    • /
    • 2003
  • The tribological mechanism between the valve plate and the cylinder block in oil hydraulic axial piston pumps plays an important role on high power density. In this study, the fluid film thickness between the valve plate and the cylinder block was measured with discharge pressure and rotational speed by use of a gap sensor, and a slip ring system in the operating period. To investigate the effect of the valve plate shapes, we designed two valve plates with different shapes . the first valve plate was without a bearing pad, while the second valve plate had a bearing pad. It was found that both valve plates behaved differently with respect to the fluid film thickness characteristics. The leakage flow rates and the shaft torque were also experimented in order to clarify the performance difference between the valve plate without a bearing pad and the valve plate with a bearing pad. From the results of this study, we found out that in the oil hydraulic axial piston pumps, the valve plate with a bearing pad showed better film thickness contours than the valve plate without a bearing pad.

농용(農用)트랙터의 3점 히치 시스템의 마이크로컴퓨터 제어(制御)(II) -성능시험(性能試驗)- (Microcomputer Control of Electronic-Hydraulic Three-Point Hitch for Agricultural Tractor(II) -Performance Test-)

  • 류관희;유수남;김영상
    • Journal of Biosystems Engineering
    • /
    • 제17권3호
    • /
    • pp.223-228
    • /
    • 1992
  • This study was conducted to develop an electro-hydraulic three-point hitch control system using an electro-hydraulic servo valve and microcomputer and to investigate the performance of the three-point hitch control system through indoor and field experiments. 1. The results from indoor experiments coincided with those from computer simulation reported in the previous paper. However, the draft control with the value 4 of Kd showed a slight sustained oscillation after it reached the draft set. 2. From the field experiments, it appeared that the RMS errors increased with the ground speed of tractor. In position control, the three-point hitch control system with electro-hydraulic servo valve showed better performance than that with on-off electro-magnetic valve in the ground speed less than 1.6 m/s. In draft control, however, there was no significant differece in performance between those two systems. 3. In depth control, the both types of electro-hydraulic three-point hitch control system showed better performance than the conventional mechanical-hydraulic three-point hitch control system.

  • PDF

Development of cryogenic free-piston reciprocating expander utilizing phase controller

  • Cha, Jeongmin;Park, Jiho;Kim, Kyungjoong;Jeong, Sangkwon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권2호
    • /
    • pp.42-47
    • /
    • 2016
  • A free-piston reciprocating expander is a device which operates without any mechanical linkage to a stationary part. Since the motion of the floating piston is only controlled by the pressure difference at two ends of the piston, this kind of expander may indispensably require a sophisticated active control system equipped with multiple valves and reservoirs. In this paper, we have suggested a novel design that can further reduce complexity of the previously developed cryogenic free-piston expander configuration. It is a simple replacement of both multiple valves and reservoirs by a combination of an orifice valve and a reservoir. The functional characteristic of the integrated orifice-reservoir configuration is similar to that of a phase controller applied in a pulse tube refrigerator so that we designate the one as a phase controller. Depending on the orifice valve size in the phase controller, the different PV work which affects the expander performance is generated. The numerical model of this unique free-piston reciprocating expander utilizing a phase controller is established to understand and analyze quantitatively the performance variation of the expander under different valve timing and orifice valve size. The room temperature experiments are carried out to examine the performance of this newly developed cryogenic expander.

3방 비례제어 조절밸브 개발 및 성능 연구 (Development of Three-Way Proportional Control Valve and Performance Study)

  • 이종화;정택수;조종두;김주용
    • 설비공학논문집
    • /
    • 제26권5호
    • /
    • pp.218-223
    • /
    • 2014
  • Korea District heating corp. recently give an attention to combine the district heating and supply pipes as a two pipe system that are in the present system separated with room heating and warm water supply pipe, and the two pipe system is commonly applied for heating service in European countries. In the new two pipe system, only one heat source is supplied to a house and partitioned into room heating and warm water supply by household substation. So the effective distribution of supplied heat source in accordance to user intention is very important. This paper presents the development and performance test of three-way proportional control valve for a combined heat source system in district heating. The proposed valve is controlled to partition heat source into two different directions : hot water distributor for space heating and household substation for warm water supply in response to the pressure drops of tap water caused by the user. The performance investigation is shown within 3% of error compared to the theoretical model of the three-way proportional valve and its controllability is verified.

정상유동에서 유동형 단엽폴리머 인공판막의 수력학적 성능평가 (Hydrodynamic Investigation of a Floating-type Monoleaflet Polymer Valve under Steady Flow Condition)

  • 김준우;박복춘
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.49-60
    • /
    • 1996
  • An experimental investigation was performed under steady flow condition to assess hydrodynamic performance of floating-type monoleaflet polymer valves (MLPV) withdifferent leaflet thickness. The St. Jude Medical valve (SJMV) was also used for comparison test. Pressure drops of MLPVS are larger than those for other types of polymer valves and mechanical valves. Furthermore, the thicker is the leaflet thickness of the polymer valve, the larger are the corresponding pressure drop. The velocity profiles for MLPs reveal a large reversed flow region downward to the valve position. The maximum wall shear stresses of MLPVS at a flow rate of $30{\ell}$/min are in the range 50-130 dyn/$cm^2$, and the corresponding maximum Reynolds shear stresses are in the range of 100-500 dyn/$cm^2$, respectively, which are beyond the allowable limit clinically. In contrast, floating-type monoleaflet polymer valves show better hydrodynamic performance in leakage volume. From the designing point of view, it may be concluded that the optimum thickness of leaflet for better hydrodynamic performance is one of the Important parameters.

  • PDF

정상유동에서 유동형 단엽폴리머 인공심장판막의 수력학적 성능평가 (Hydrodynamic Investigation of a Floating-type Monoleaflet Polymer Heart Valve under Steady Flow Condition)

  • 박복춘;김준우;백병준;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.241-246
    • /
    • 1995
  • An experimental investigation was performed under steady flow condition to assess hydrodynamic performance of floating-type monoleaflet polymer valves (MLPV) with different leaflet thickness. The St. Jude Medical valve (SJMV) was also used for comparison tests. Pressure drops of MLPVs are larger than those for other types of polymer valves and mechanical valves. Furthermore, the thicker is the leaflet thickness of a polymer valve, the larger arc the corresponding press drop. The velocity profiles for MLPV reveal a large reversed flow region downward to the valve position. The maximum wall shear stresses of MLPVs at a flow rate of 30 l/min are in the range $54-130\;dyn/cm^2$, and the corresponding maximum. Reynolds shear stresses are in the range of $100-500\;dyn/cm^2$, respectively. Both arc beyond the allowable limit clinically. In contrast, floating-type monoleaflet polymer valves show better hydrodynamic performance in leakage volume. From the designing point of view, it can be concluded that the optimum thickness of leaflet for better hydrodynamic performance is one of the important parameters.

  • PDF

플랩제어시스템 주제어밸브의 모델기반 설계 및 성능해석 (Model-based Design and Performance Analysis of Main Control Valve of Flap Control System)

  • 조현준;안만진;주춘식
    • 항공우주시스템공학회지
    • /
    • 제13권4호
    • /
    • pp.50-59
    • /
    • 2019
  • 플랩제어시스템의 주요 구성품인 주제어밸브의 설계는 실제 제작 경험을 바탕으로 반복-오차 방법에 의존하여 수행하였다. 본 논문에서는 모델 기반의 부품 설계 방법을 제안하였다. 플랩제어시스템은 주제어 밸브, 고장-안전 밸브, 솔레노이드 밸브, LVDT, 구동 모터 등으로 구성된다. 주제어밸브는 주로 스풀과 슬롯으로 구성된다. 주제어밸브의 중요한 설계변수는 슬롯의 폭 (Slot Width), 오버 랩(Overlap) 및 간극(Clearance)이다. AMESim을 활용하여 주 제어 밸브의 유로를 모델링하고 해석하였다. 제안된 설계절차를 적용한 결과 허용된 가공오차 범위 내에서 요구 성능을 충족함을 확인하였다.

반도체 약액용 자동제어 플라스틱 밸브의 내부 유동해석 (Internal Flow Analysis and Structural Design in Plastic Automatic Control Valve for the Semiconductor Chemical Liquid)

  • 이규훈;이응석;이민기;김진수;배일진
    • 한국생산제조학회지
    • /
    • 제21권2호
    • /
    • pp.311-315
    • /
    • 2012
  • Diaphragm type noncontact automatic control valve is a valve for controling acidic PR(Photo Resist) liquid used in the semiconductor process. PR is photosensitive liquid that changes phases depending on light transmittance. PR is very toxic and expensive; the purpose of this paper is to address methods that prevent loss due to leaks. The design of noncontact precise automatic control valve is expected to play an important role in controlling fluid flow, therefore influencing energy conservation and environmental improvement. In this paper, diaphragm type automatic control valve's part design, assembly and simulation are introduced. Also, through the analysis of fluid flow the valve's internal velocity, pressure, and turbulent intensity are interpreted. This paper proposes to contribute to the improvement of the valve's performance.

ER 댐퍼의 밸브 형상에 따른 감쇠 특성의 해석 및 실험 (An Analysis and Test Results of Damping Characteristics of ER Dampers with Two Different Valve Types)

  • 장보영;이종민;김창호;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.608-613
    • /
    • 1998
  • Damping characteristics of ER dampers and flow rates inside ER valve with two different valve types were analyzed and compared with test results. Fluid flow inside ER valves was modeled by Bingham plastic model and Hagen-Poiseulli flow, while the equations of motion of total ER damper system were modeled by flow and hydraulic force balance. A general straight valve case was compared with a bended valve case which is newly tested for a possible improvement of ER damping force. As expected, the bended ER valve generates higher damping force and lower flow rates than the conventional straight ER valve due to additional flow restriction at the bended section. Analytical models of ER valve and ER damper generally predict reasonable performance characteristics of tested results. Therefore, developed analysis can be used for designing new ER dampers and simulation of ER semi-active suspension system as well.

  • PDF