• 제목/요약/키워드: Valve performance

검색결과 1,244건 처리시간 0.029초

여과형 비점오염 처리장치의 오염물질 제거특성 및 역세척 분석 (The Performance of Pollutant Removal Using Nonpoint Treatment Filtration Device and Analysis of the Filter Backwashing Effect)

  • 이준호;양승호;방기웅
    • 한국물환경학회지
    • /
    • 제31권5호
    • /
    • pp.523-532
    • /
    • 2015
  • Hydrocyclone is widely used in industry, for its simple design, high capacity, low maintenance and low operational cost. The objective of this study is to develop hydrocyclone coagulation and filtration system. The system is made of hydrocyclone ballasted coagulation with polyaluminium chloride silicate (PACS) and upflow filter to treat micro particles in urban storm runoff. Roadside sediment particles (< $200{\mu}m$) was mixed with tap water to make various turbid suspensions to simulate urban storm runoff. The filter cartridge was filled with polyethylene media system and ran 1hr per everyday and total operation time were 8.19hrs and backwashing everyday after end of operation. The operation condition of flowrate was $8.2{\sim}11.9m^3/day$ (mean $10.1m^3/day$) and surface overflow rate (SOR) based on filter surface area was $45.5{\sim}65.9m^3/m^2/day$ (mean $55.7m^3/m^2/day$). The range of PACS dosage concentration was 14.0~31.5 mg/L. As the results of operation, the range of removal efficiency of turbidity, SS were 81.0~95.8% (mean 89.5%) 81.8~99.0% (mean 91.4%), respectively. An increase of filtration basin retention time brought on increased of removal efficiency of turbidity and SS, and increase of SOR brought on decreased of removal efficiency. During the first flush in urban area, storm runoff have an high concentration of SS (200~600 mg/L) and the filtration bed becomes clogged and decreased of removal efficiency. Backwashing begins when the drainage pipe valve at the filtration tank bottom is completely open (backwashing stage 1). Backwashing stage 2 was using air bubbles and water jet washing the media for 5 mins and open the drainage valve. After backwashing stage 1, 2, 61.83~64.04%, 18.53~27.51% of SS loading was discharged from filtration tank, respectively. Discharged SS loading from effluent was 7.12~14.79% and the range of residual SS loading in fliter was 2.26~5.00%. The backwashing effects for turbidity, SS were 89.5%, 91.4%, respectively. The hydrocyclone coagulation and filtration with backwashing system, which came out to solve the problems of the costly exchange filter media, and low efficiency of removing micro particles of filter type nonpoint treatment devices, is considered as an alternative system.

도시철도차량 제동장치의 솔레노이드 밸브에 대한 전류기반 고장진단기법 개발 (A Fault Detection Method for Solenoid Valves in Urban Railway Braking Systems Using Temperature-Effect-Compensated Electric Signals)

  • 서보성;이규석;조수호;오현석;윤병동
    • 대한기계학회논문집A
    • /
    • 제40권9호
    • /
    • pp.835-842
    • /
    • 2016
  • 국내 도시철도차량의 유지보수는 대부분 예방정비에 기초하고 있다. 기존 유지보수 방법의 한계를 극복하기 위해, 상태기반 유지보수기법을 철도차량에 적용하려는 움직임이 최근 활발히 진행되고 있다. 본 연구는 도시철도차량 제동장치의 핵심 고장부품인 솔레노이드 밸브에 대하여 전류기반 고장진단기법 개발을 시도하였다. 주요 고장부품으로 선정된 솔레노이드 밸브에 대하여, 등가회로모델 및 온도 보상된 전류 감시에 기반한 고장 진단법을 제안하였다. 제안한 고장 진단법의 유효성을 검증하기 위해 실제 도시철도차량에 사용되는 솔레노이드 밸브(상용제동 전자밸브)를 이용하여 사례연구를 진행했다. 본 연구는 철도차량 제동장치의 솔레노이드 밸브 고장진단이 추가 센서의 장착 없이 가능함을 보여주었고, 철도차량의 안전성 및 신뢰성 향상에 도움을 줄 것으로 기대한다.

농업용 트랙터의 프론트 로더 충격 저감을 위한 유압 회로의 설계 개선 (Improved Design of Hydraulic Circuit of Front-end Loader for Bump Shock Reduction of an Agricultural Tractor)

  • 조봉진;안성욱;이창주;윤영환;이수성;김학진
    • 드라이브 ㆍ 컨트롤
    • /
    • 제13권2호
    • /
    • pp.10-18
    • /
    • 2016
  • A front-end loader (FEL) mounted on an agricultural tractor is one of the most commonly used implements to mechanize routine agricultural tasks. When the FEL is used with a loaded bucket, careful operation is required to maintain safety and avoid spillage when the tractor passes a bump because a change in the gravity center of the tractor due to varied loadings can affect the stability of the tractor. Use of a boom suspension system consisting of accumulators and orifice dampers can be instrumental in reducing pitching vibrations while increasing the handling performance of the FEL-mounted tractor. The objective of this research was to reduce bump shocks by adding an orifice and a flow control valve to the original hydraulic circuit composed solely of accumulators. A simulation study was performed using the SimulationX program to investigate the effects of an accumulator and an orifice-throttle damper on bump shocks. Results showed that the peak pressure on a boom cylinder and the vertical acceleration of a bucket were significantly affected by use of both an accumulator and an orifice damper. In a field test conducted with a 75-kW tractor, the peak pressure of the boom cylinder, and the root mean square (RMS) vertical acceleration of the bucket and seat were reduced by on average, 23.0, 42.2, and 44.9% respectively, as compared to those measured with the original accumulator system, showing that an improved design for the accumulator hydraulic circuit can reduce bump shocks. Further studies are needed to design a tractor suspension system that includes the effects of cabin suspension and tires as well as dynamic analysis.

인터쿨러와 공랭식 응축기를 동시에 사용하는 냉방-냉동 겸용 캐스케이드 사이클에 대한 연구 (A Study on the Cascade Hybrid Cooling/Refrigeration Cycle Equipped With Intercooler and Air-Cooled Condenser in Series)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제20권7호
    • /
    • pp.353-362
    • /
    • 2019
  • 그간 캐스케이드 냉동 시스템에 대해서 열역학적 해석은 다수 수행되었으나 증발기, 응축기, 인터쿨러 등 부품 해석을 통한 시스템 평가는 미진한 상태이다. 본 연구에서는 냉방 및 냉동 열교환기가 별도로 장착되어 있고 하부 사이클에 공랭식 응축기와 인터쿨러가 직렬로 연결되어 있는 캐스케이드 냉동 사이클에 대해 성능 해석을 수행하였다. 우선 증발기, 응축기, 인터쿨러 등 요소부품에 대해 모델링을 수행하고 R-410A를 사용하는 냉방 능력 8 kW, 냉동 능력 15 kW의 캐스케이드 냉동 사이클의 요소 부품의 - 상부 응축기, 하부 응축기, 냉방 증발기, 냉동 증발기, 인터쿨러, 압축기, 전자팽창변 - 설계를 수행하였다. 설계 사양에 대하여 외기 온도를 $26^{\circ}C$에서 $38^{\circ}C$로 변화시키며 해석을 수행한 결과 냉각 열량은 하부 증발기에서는 거의 일정하고 상부 증발기에서는 9% 감소, 인터쿨러에서는 63% 증가하였다. 한편 COP는 외기 온도의 증가에 따라 감소하였다. 인터쿨러가 작동하지 않는 사이클 대비 인터쿨러 사이클이 COP 측면에서 우위를 보였다. 또한 상부 응축기의 크기를 당초 설계치의 2배 증가시키면 하부 증발기 열량은 변함이 없는 반면 상부 증발기 열량은 4% 증가하였다. 한편 상부 응축기의 크기 증가에 따라 상부 사이클의 COP는 증가하는 반면 하부 사이클의 COP는 큰 변화가 없다. 또한 하부 응축기 크기를 2.8배 증가시키면 상하부 증발기의 열량 변화는 거의 없고 인터쿨러의 열량만이 8% 감소하였다. 아울러 하부 사이클의 COP는 응축기의 크기가 증가함에 따라 다소 증가하였으나 상부 사이클의 경우는 그 변화가 미미하였다.

전동식 부항기에 대한 안전성 및 성능평가 가이드라인 개발연구 (Study on Developing Assessment Guideline for Safety and Performance of Electric Cupping Apparatus)

  • 이승호;김은정;신경훈;남동우;강중원;이승덕;이혜정;이재동;김갑성
    • Journal of Acupuncture Research
    • /
    • 제26권6호
    • /
    • pp.101-110
    • /
    • 2009
  • Objectives : We developed and proposed a guideline for safety and performance assessment of electric cupping apparatus(Class 2 medical device). Methods : We drafted the guideline for safety and performance assessment of electric cupping apparatus by referring the existing standards and guideline, based on online questionnaire for Korean medical doctors and measurement data from commercially available products. Physical dimension of cups and inner vacuum pressure were acquired for the measurement in order to achieve the purposes. Results : This guideline only can be applied to electric cupping apparatus for enhancing blood circulation by employing negative pressure generated by electricity. Seven items of appearance and label, operation test of pump, variation test of input electricity, vacuum level test, vacuum sustain test, cup-size dependent test, noise level test are suggested for evaluation subjects and methods required for electric cupping devices. Requirements for the design and development of electric cupping devices are suggested: vacuum level indicator, vacuum generation rate, pressure control, valve detachment stability, cup comparability, safety measure, surge protection, user friendliness, instruction for use (IFU). Conclusions : We proposed a guideline for safety and performance assessment of electric cupping apparatus to improve the quality of relating products and aid the commercialization of them, by aiming higher industrial competitiveness of the medical device sectors in Korea. Discussion with related institutes such as industry, academy and government is further required. Public hearings also need to be held prior to the establishment of a final guideline and standard.

  • PDF

양극 닫힌계 작동에서 수소 배출 방법에 의한 고분자전해질 연료전지 성능 영향 (Effect of Hydrogen Purge Mode on the Polymer Electrolyte Membrane Fuel Cell (PEMFC) Performance under Dead-ended Anode Operation)

  • 김준섭;김준범
    • 공업화학
    • /
    • 제30권6호
    • /
    • pp.687-693
    • /
    • 2019
  • 수소전기차와 발전을 시작으로 수소연료전지 시장이 성장하면서 연료전지와 수소의 수요가 증가하고 있으므로, 조기 상용화와 시장 활성화를 위하여 연료전지의 내구성과 연료 이용효율에 관한 연구가 진행되어야 한다. 본 연구에서는 연료전지의 성능과 연료 이용효율을 최적화하기 위하여 양극 닫힌계의 운전조건에 대한 연구를 수행하였다. 부하 전류에 대한 배출 조건과 수소 공급 압력이 고분자전해질 연료전지의 성능에 미치는 영향에 대하여 평가하였고, 전해질막 두께에 대한 물의 역확산 영향을 분석하였다. 양극 닫힌계에서 수소극에 쌓인 물은 연료전지 전압이 3% 감소한 경우에 솔레노이드 밸브를 열어 배출하였다. 수소 공급 압력은 0.1~0.5 bar, 배출 시간은 0.1~1 s까지 변화시키면서 실험을 수행하였다. NR 211 (25.4 um) 전해질막의 경우 0.1 bar의 수소 공급 압력과 0.1 s 배출 시간 조건에서 수소 이용효율 98.9%의 가장 높은 연료 이용효율을 보였지만 잦은 flooding으로 인하여 장시간 운전 시 연료전지의 성능이 감소하였다. 이에 반해 NR 212 (50.8 um)의 전해질막에서 생성된 물과 질소의 역확산 속도를 늦추어 배출 간격을 늘리고 연료 이용효율을 높일 수 있었다.

곡물냉각기의 개발 (Development of a New Commercial Grain Cooler)

  • 김동철;김의웅;금동혁;한종규
    • 한국식품저장유통학회지
    • /
    • 제11권2호
    • /
    • pp.250-256
    • /
    • 2004
  • 국내의 기상조건 및 벼의 수확후 처리여건에 적합한 곡물냉각기를 개발하고, 냉각능력, 재열능력, 가열능력, 소요전력 및 성능계수 등의 성능을 측정하여 설계조건에 적합한지를 분석하였다. 그 결과를 요약하면 다음과 같다. 압축기 무부하전자변과, 재열기 및 증발기에 고온고압의 냉매가스를 공급하여 냉각능력을 0∼100%까지 제어할 수 있고, 온도 5$^{\circ}C$이상, 상대습도 54∼95%의 정온정습 공기를 발생할 수 있는 1일 최대 벼 200톤을 냉각할 수 있는 곡물냉각기를 개발하였다. 이 곡물냉각기의 최대냉각능력은 35,284㎉/hr, 송풍량 및 정압은 각각 120㎥/min, 279mmAq이었으며, 재열기를 통한 냉각공기의 최대 온도상승 및 상대습도의 저하범위는 각각 7.6∼8.6$^{\circ}C$, 34.5∼41.0%이었으며, 최대가열능력은 5.6$^{\circ}C$이었다. 또한, 최대 소요동력은 22.8㎾이었으나, 압축기의 무부하 전자변이 작동될 때는 총소요동력의 33.3%, 압축기 소요축동력의 44.7%가 절약되는 것으로 나타났으며, 제어조건에 따라 전체소요동력의 26.7~33.3%정도가 절약되는 것으로 나타났으며, 냉동시스템의 성능계수는 과냉각으로 인해 표준냉동사이클하에서의 4.0보다 높은 4.71이었으며, 전성능계수는 1.8로 나타났다.

연료전지 스택 폐열 활용 전동식 히트펌프 시스템 난방 성능 특성 연구 (Experimental study on heating performance characteristics of electric heat pump system using stack coolant in a fuel cell electric vehicle)

  • 이호성;김정일;원헌주;이무연
    • 한국산학기술학회논문지
    • /
    • 제19권12호
    • /
    • pp.924-930
    • /
    • 2018
  • 본 연구의 목적은 수소연료전지 자동차의 난방부하 대응을 위한 스택 냉각수를 활용하여서, 전동식 히트펌프 시스템에 대한 난방성능 특성을 다양한 운전조건 변화에 대해서 고찰하는 것이다. 냉각수와 냉매(R-134a)와의 열교환을 위해서 판형열교환기를 적용하였고, 전동식 히트펌프 시스템에 적용되는 실내열교환기 입구의 공기온도와 압축기 회전수를 변화시키면서 난방 성능 특성을 분석하였다. 실내열교환기 입구 공기 온도 변화에 대해서 난방 성능은 거의 동일한 결과를 보이고 있는데, 이는 입출구 온도차와 공기 측 밀도의 변화가 균형을 이루었기 때문으로 판단된다. 반면, 히트펌프 시스템 효율(COP)의 경우, 난방 성능은 온도변화에 따라 동일하였지만, 유량 변화로 인하여서, 압축기 소모동력이 감소하였기 때문에, 실내열 교환기 입구 온도가 감소함에 따라서, 시스템 효율은 증가하는 경향을 보이고 있다. 추가적으로, EEV개도가 45%정도까지 열리는 구간에서는, 압축기 소모전력 감소하였기 때문에, 시스템 효율이 증가하였고, 그 이후에는 동일한 시스템 효율을 유지하는 것을 알 수 있었다. 압축기 회전수 변화 시에는 난방성능이 증가하면, 시스템 효율은 감소하는 경향을 보여주고 있다. 이러한 원인은 압축기 회전수 증가에 따른 유량의 증가로 판단된다. 향후, 열원으로 사용하는 냉각수에 대한 운전조건을 변화시켜가면서, 난방성능 특성을 분석하여, 전동식 히트펌프의 난방부하 대응을 위한 제어 방안을 연구하고자 한다.

외부 개질형 평판형 고체 산화물 연료전지 시스템 구성법에 따른 효율특성 (A Case Study of Different Configurations for the Performance Analysis of Solid Oxide Fuel Cells with External Reformers)

  • 이강훈;우현탁;이상민;이영덕;강상규;안국영;유상석
    • 대한기계학회논문집B
    • /
    • 제36권3호
    • /
    • pp.343-350
    • /
    • 2012
  • 본 연구에서는 외부 개질기에 열원을 공급하기 위한 시스템 내에 가용한 열에너지의 활용 및 확보에 대한 해석을 위해서 외부 개질기를 연계한 평판형 SOFC 시스템의 해석 모델을 구축하고자 한다. 이러한 해석을 위한 모델 구축을 위해 Matlab simulink$^{(R)}$ 기반의 ThermoLib module을 사용하였으며, 구축된 해석 모델을 통하여 시스템의 성능 향상을 위한 구성 기법에 대해서 연구를 하였다. 시스템 구성 방법은 기존 시스템의 layout을 바꾸기 위해 공기극 출구가스 재순환 및 외부개질기와 촉매연소기를 통합한 개질반응시스템 적용, 개질기에 공급되는 혼합연료의 예열, 연료극 출구가스의 응축을 통한 연료 농도 향상 등을 고려하였다. 시뮬레이션의 해석 결과에서는 SOFC 시스템에 있어서 일반 연소기를 적용한 기준 시스템에 비하여 촉매 연소기를 사용한 시스템의 전기 효율이 12.13% 향상되었으며, 연료극 출구 가스를 응축시켜 버너로 연소시킨 시스템에서는 열효율이 76.12%로 가장 높았다.

용적형 펌프를 추가한 소방자동차용 소방펌프의 성능 인정기준에 관한 연구 (Fire-fighting Pump Approval Standard for Fire-fighting Trucks with an Additional Positive Displacement Pump)

  • 한용택;성기찬;민세홍
    • 한국화재소방학회논문지
    • /
    • 제30권1호
    • /
    • pp.104-110
    • /
    • 2016
  • 본 연구는 2012년도에 제정된 원심펌프 기준에 바탕을 둔 소방자동차용 소방펌프의 성능 인정 기준에 각종 초고층 건물의 화재 및 대형화재에 대비하기 위한 고압 및 대용량의 방수 능력을 가진 용적형 펌프의 인정기준 추가에 관한 내용이다. 용적형 펌프의 실험을 바탕으로 V-1, 2, 3급의 3가지에 대한 성능에 대하여 인정기준을 제정하였으며 펌프의 효율은 원심펌프형과 동일한 65% 이상의 성능을 요구하는 인정기준이 포함 되었다. 방수압력은 1.5 MPa~2.5MPa 사이의 값을 유량은 최소 $0.31m^3/min$에서 최대 $3.0m^3/min$의 방수량의 성능을 요구하는 것으로 제정되었다. 또한, 구조적으로 체절압력을 조절해야하는 용적형 펌프 특성상 릴리이프 밸브에 대한 부분이 추가되었으며 이물질로 인한 펌프 내부의 파손을 방지하기 위한 스트레이너 설치 및 진공펌프 없이 작동하는 용적형 펌프와 원심펌프와의 차이점을 포함하고 있다. 이와같은 용적형 펌프의 인정기준 부분 추가로 인하여 초고층 빌딩 및 대형화재에서의 화재진압에 있어서 보다 다양한 화재 진압용 소방 장비의 선택과 능동적인 대응을 할 수 있을 것으로 기대되며, 이와같은 인정기준은 2016년 1월 제정되었다.