• 제목/요약/키워드: Valve location

검색결과 87건 처리시간 0.029초

모세관 인력으로 작동되는 열공압형 마이크로 펌프의 형상이 성능에 미치는 영향 (The Influence of the Geometry on the Performance of a Thermopneumatic Micropump Operated by Capillary Attraction)

  • 전도한;양상식
    • 대한기계학회논문집B
    • /
    • 제33권10호
    • /
    • pp.778-782
    • /
    • 2009
  • Recently, we developed a simple thermopneumatic micropump having neither a membrane nor a valve. This micropump discharges liquid by a thermopneumatic pressure and refill by a capillary attraction. In case of the micropump driven by the capillary attraction, the flow characteristic depends mainly on the geometry of the micropump. In this paper, we investigated the influence of the geometry of the micropump on the performance of the micropump to illustrate the properness of the micropump shape. We analyzed the micropump characteristics of six types having different geometries by FVM simulation with a commercial CFD tool. Also we fabricated the micropumps with PDMS and glass by micromachining, and tested the performances. The simulation and the test results illustrate that the discharge volume and the discharge time depend on the chamber volume. The expansion angle of the inlet channel location has influence on the refill time, while the front air channel direction has influence on the backward flow loss.

단수피해 최소화를 위한 상수관망 내 최적 밸브위치 선정 (Determination of Optimal Valve Location in Water Distribution Networks)

  • 임갑율;강두선
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2018년도 학술발표회
    • /
    • pp.108-108
    • /
    • 2018
  • 상수관의 노후화 혹은 공사 중 작업자의 실수, 또는 자연재해 등에 의해 상수관망 내 파손 관이 발생할 경우 파손된 관의 보수 및 교체 작업을 위해서는 파손 관과 인접한 밸브를 차폐하게 된다. 이로 인하여 관망의 일부 지역에 물 공급이 차단되는 단수구역이 발생하게 되며, 단수구역은 밸브를 닫음으로 인해 파손 관과 함께 격리되는 직접고립지역(segment)과 직접고립지역을 차폐함으로써 의도치 않게 수원으로부터 물 공급이 차단되는 간접고립지역(unintended isolation)으로 구분할 수 있다. 간접고립지역은 차폐된 직접고립지역으로 인해 수원으로부터의 유일한 용수공급 노선이 차단되어 발생한다. 관 파손에 의한 단수 피해를 현실적으로 모의하기 위해서는 밸브위치에 따른 단수구역을 정확히 산정할 필요가 있다. 단수구역은 파손관의 위치뿐만 아니라 차단 밸브의 개수 및 위치에 따라 달라진다. 따라서, 관 파손에 의한 단수피해를 최소화하기 위해서는 각 관로의 파손확률과 절점의 중요도를 고려하여, 적절한 밸브의 위치를 선정해야 한다. 본 연구에서는 관 파손에 따른 단수상황을 모의하여 파손 관에 의한 직, 간접 단수구역을 탐색한 후, 단수용량을 파악하고 이를 최소화하기 위한 밸브의 적정 위치를 최적화 알고리즘을 이용하여 결정하는 방안을 제시하였다.

  • PDF

밸브위치 및 단수구역을 고려한 상수관망 지진피해 복구 (Post-earthquake Restoration of Water Supply Network considering Valve Location and Segment Layout)

  • 최정욱;강두선
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2018년도 학술발표회
    • /
    • pp.19-19
    • /
    • 2018
  • 최근 경주, 울산, 포항 등 경상도 지역에서 잇달아 발생한 대규모 지진으로 인해 사회기반시설물의 내진 안전성이 이슈가 되고 있다. 지진 안전 국가라고 여겨지던 우리나라는 상대적으로 지진에 대한 대비가 매우 부족한 실정이며, 자칫 대규모 피해로 이어질 우려가 있다. 특히 상수관망의 경우, 지중에 매설되어 있는 특성상 지진에 취약하고, 그 피해를 발견하기 어려워 장기적인 피해가 불가피하다. 상수관로의 지진피해는 누수와 파손으로 구분할 수 있으며, 파손관의 경우 용수공급능력을 크게 저하시키기 때문에 신속한 복구가 요구된다. 파손관의 복구는 부근에 위치한 차단밸브를 닫아 피해관로의 통수를 차단한 후에 복구 작업을 진행하는 것이 일반적이다. 이때, 차단밸브의 위치에 따라 단수구역이 광범위하게 발생할 수 있어 시스템 전반의 용수공급능력 저하로 이어질 가능성이 있다. 본 연구에서는 지진 발생 후 피해관로의 효율적인 복구전략 마련을 위한 상수관망 지진피해 복구 시뮬레이션 모형을 개발하였다. 개발 모형은 피해복구에 따른 상수관망 시스템의 용수공급능력을 정량적으로 산정할 수 있으며, 지진 발생과 같은 비정상 상황의 시스템 용수공급능력을 수리학적으로 정확하게 해석하기 위해 압력기반의 해석(Pressure-driven analysis, PDA)을 적용하였다. 또한, 피해관로의 복구 시, 차단밸브에 의해 발생되는 단수구역을 탐색한 후, 수리해석 모의에 적용함으로써 현실적인 용수공급 상황을 모의할 수 있도록 하였다. 본 연구에서는 개발모형을 활용하여 차단밸브의 위치 및 개수가 단수구역의 범위 및 지진복구에 미치는 영향을 정량적으로 비교 분석하였으며, 이를 통해 효율적인 지진피해 복구 전략을 제시하였다.

  • PDF

수치해석을 통한 건설중장비 유압시스템용 파이프설계에 대한 연구 (Pipe Design for Hydraulic System in Construction Heavy Equipment by Numerical Analysis)

  • 신유인;이중섭;한성길;이호성
    • 한국기계가공학회지
    • /
    • 제18권9호
    • /
    • pp.64-71
    • /
    • 2019
  • We herein propose a systematic design method of hydraulic pipes used in heavy construction equipment. We found that even though many design studies have been conducted regarding major hydraulic components such as pumps, cylinders, and control valves, studies regarding the optimal design of hydraulic pipes are scarce. In this study, the design of four types of pipes is considered: two high-pressure and two low-pressure pipes. First, fluid flow analysis was conducted based on oil flow and pressure for various radii of curvature. For a check-valve pipe, we considered the location of an inlet pipe. We could visualize fluid flow inside the pipe according to the flow velocity and pressure distribution. Based on fluid flow analysis, we conducted a structural analysis that revealed the stress distribution and concentration for each pipe design. We selected the best design parameters for each pipe design, fabricated the pipes, and subsequently tested them for validity.

Best-Estimate Analysis of MSGTR Event in APR1400 Aiming to Examine the Effect of Affected Steam Generator Selection

  • Jeong, Ji-Hwan;Chang, Keun-Sun;Kim, Sang-Jae;Lee, Jae-Hun
    • Nuclear Engineering and Technology
    • /
    • 제34권4호
    • /
    • pp.358-369
    • /
    • 2002
  • Abundant information about analyses of single steam generator tube rupture (SGTR) events is available because of its importance in terms of safety. However, there are few literatures available on analyses of multiple steam generator tube rupture (MSGTR) events. In addition, knowledge of transients and consequences following a MSGTR event are very limited as there has been no occurrence of MSGTR event in the commercial operation of nuclear reactors. In this study, a postulated MSGTR event in an APR1400 is analyzed using thermal-hydraulic system code MARSI.4. The present study aims to examine the effects of affected steam generator selection. The main steam safety valve (MSSV) lift time for four cases are compared in order to examine how long operator response time is allowed depending on which steam generate. (S/G) is affected. The comparison shows that the cases where two steam generators are simultaneously affected allow longer time for operator action compared with the cases where a single steam generator is affected. Furthermore, the tube ruptures in the steam generator where a pressurizer is connected leads to the shortest operator response time.

울산지역 공원에서 채집된 모기의 심장사상충 감염도 조사 (Survey on infection rate of Dirofilaria immitis in mosquitoes collected from the parks in Ulsan)

  • 차세진;윤남식;이승준;장지택
    • 한국동물위생학회지
    • /
    • 제45권4호
    • /
    • pp.317-323
    • /
    • 2022
  • Dirofilariasis is a mosquito-borne parasitic infection that mainly causes symptoms such as chronic cough, respiratory distress, abnormal breath sounds, heart valve dysfunction, right heart hypertrophy, liver congestion and cirrhosis, ascites, and pleural effusion in dogs. In this study, from June to September 2021, we collected and identified mosquitoes in parks where citizens often take their dogs for a walk, and created pools from them by month, species, and location. These pools were checked for the infection of Dirofilaria immitis by PCR and the minimum infection rates (MIRs) were calculated. The MIR of all mosquitoes collected was 6.4, and the MIRs of mosquitoes from Daewangam Park, Yeocheoncheon Walk, Taehwagang National Garden, and Sinbulsan County Park were 9.7, 4.7, 2.1, and 0, respectively. It also confirmed that Aedes hatorii, Aedes vexans nipponii, and Ochlerotatus koreicus were major vectors of heartworm in Ulsan. Our results suggest that heartworm prophylaxis should be considered in Ulsan.

Quantifying Energy Consumption to the Level of Service Pressure in Water Distribution Network

  • Marlim, Malvin S.;Choi, Jeongwook;Kang, Doosun
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2022년도 학술발표회
    • /
    • pp.458-458
    • /
    • 2022
  • It is essential to reduce global carbon emissions, mainly from energy use. The water supply and distribution sector is a vital part of human society and is one of the primary energy consumers. The procurement and distribution of water require electricity to operate the pump to deliver water to users with sufficient pressure. As the water users are spatially distributed over a wide area, the energy required to deliver water to each user differs depending on the corresponding supplying element (reservoir, tank, pipe, pump, and valve). This difference in energy required for each user also comes with a difference in pressure availability which affects the level of service for individual users and the whole network. Typically, there is a disproportion where users close to the source experience excessively high pressure with low energy consumption. In contrast, remote users need more energy to get the minimum pressure. This study proposes the Energy Return Index (ERI) to quantify the pressure return from particular energy consumption to supply water to each node. The disproportionality can be quantified and identified in the network using the proposed ERI. The index can be applied to optimize the network elements such as pump operation and tank location/size to reach a balanced energy consumption with the appropriate level of service.

  • PDF

교류전류를 이용한 새로운 비파괴탐상법의 개발;표면결함과 이면결함의 평가 및 실기 부재의 결함 검출 (Development of the Advanced NDI Technique Using an Alternating Current : the Evaluation of surface crack and blind surface crack and the detection of defects in a field component)

  • 김훈;임재규
    • Journal of Welding and Joining
    • /
    • 제13권2호
    • /
    • pp.42-52
    • /
    • 1995
  • In the evaluation of aging degradation on the structural materials based on the fracture mechanics, the detection and size prediction of defect are very important. Aiming at nondestructive detection and size prediction ol defect with high accuracy and resolution, therefore, an lnduced Current Focusing Potential Drop(ICFPD) technique has been developed. The principle of this technique is to induce a focusing current at an exploratory region by an induction wire flowing an alternating current(AC) that is a constant ampere and frequency. Defects are assessed with the potential drops that are measured the induced current on the surface of metallic material by the potential pick-up pins. In this study, the lCFPD technique was applied for evaluating the location and size of the surface crack and blind crack made in plate specimens, and also for detecting the defects existing in valve, a field component, that were developed by SCC etc. during the service. The results of this present study show that surface crack and blind crack are able to defect with potential drop. these cracks are distinguished with the distribution of potential drop, and the crack depths can be estimated with each normalized potential drop that are parameters estimating the depth of each type crack. In the field component, the defects estimated by experiment result correspond with those in the cutting face of the measuring point within a higher sensitivity.

  • PDF

IoT를 이용한 상수도관의 효율적인 수압 측정 시스템 (An Efficient Water Pressure Measurement System of the Water Pipes using IoT)

  • 이재수;최인호;홍권의;최학윤;노희정;안정근
    • 한국ITS학회 논문지
    • /
    • 제17권1호
    • /
    • pp.114-122
    • /
    • 2018
  • 본 논문은 맨홀 아래 지하에 매설된 상수도관의 수압을 효율적으로 측정하기 위하여 무선통신 모듈을 내장한 수압센서(IoT)를 모든 상수도관 밸브에 설치하여 수압을 측정하도록 하였다. 측정한 데이터는 무선 통신으로 스마트폰에 전송하고 스마트폰은 수신한 데이터를 다시 서버로 전송하여 저장하고 관리할 수 있도록 하는 새로운 수압측정 시스템을 제안하였다. 담당자들은 서버에 저장된 수압 데이터를 원격에서 조회하여 상수도관의 누수 여부나 관리지역 내의 수압의 적정성 여부 등을 확인하여 이상 여부를 체크할 수 있도록 함으로써 상수도관의 수압을 효율적으로 관리할 수 있다.

공조용 로터리 압축기의 소음 저감에 관한 연구 (A Study on Noise Reduction of Rotary Compressor)

  • 안병하;김영수
    • 동력기계공학회지
    • /
    • 제3권3호
    • /
    • pp.60-69
    • /
    • 1999
  • The noise and vibration sources of rotary compressor for room air-conditioner are pressure pulsation of compression process, cavity resonance of inner space, structural radiation noise of shell and impact noise of discharge valve. Among them, pressure pulsation is very important noise and vibration source. Because it transferred various kinds of noise and vibration like as mentioned above. In this reason, muffler and resonator are used in order to absorb and remove these noises. But an analytical prediction using acoustic analysis does not coincident with the experimental result. The difference between analysis and actual state is due to the assumption of analysis. This paper covered with new concept of muffler design based on the turbulence kinetic energy of flow by using CFD. From this analysis, it is possible to decide the best position of discharge port of muffler. Therefore $2{\sim}3dB$ noise reduction effect is acquired in rotary compressor of 5000 BTU grade. Also new approach of resonator design is suggested. From this study, the characteristics of resonator and surge hole (a kind of resonator without pipe length) are identified. The former is useful for pure tone noise (narrow frequency band), and the latter is effective for broad frequency band. This paper shows that it is very available to use 3 dimensional analysis of resonator in order to predict more exact tuning frequency. The result is proved by a lot of experiments. From combination of fluid analysis and acoustic analysis, up stream position is effective location of resonator concerning turbulence motion of fluid.

  • PDF