• 제목/요약/키워드: Valve area gradient

검색결과 19건 처리시간 0.025초

도플러 초음파를 이용한 인공판막 상하의 압력차 측정에 관한 연구 -승모판막 치환에 사용한 Duromedics 인공판막과 정사인의 승모판막과의 비교연구- (Noninvasive assessment of pressure gradients across prosthetic heart valve by doppler ultrasound -A comparative studyof the duromedics bileaflet valves in mitral position and normal mitral valves-)

  • 진성훈;서경필
    • Journal of Chest Surgery
    • /
    • 제20권2호
    • /
    • pp.223-229
    • /
    • 1987
  • Doppler echocardiography provides valuable information regarding prosthetic heart valve function rather than structure. There are three methods of expressing the severity of mitral valve obstruction: the transvalvular pressure gradient, effective valve area, and pressure half-time. Of these, the transvalvular pressure gradient [~p] can be determined by the measurement of maximum transvalvular blood flow velocity [V] according to the modified Bernoulli`s equation [gp=4V*]. Eleven patients, who underwent mitral valve replacement with Duromedics mechanical prostheses, and 17 normal persons were investigated. There were significantly higher calculated pressure gradients in prosthetic than normal mitral valves [9.*10*2.22mmHg-vs-3.26*0.99mmHg:p<0,01], and there was a inverse relationship between pressure gradient and prosthetic valve size [11.17*0.%mmHg in size 27mm and 29mm -v- 7.38*1.12mmHg in size 31mm and 33mm; r=0.85, p<0.01] The noninvasive Doppler technique should be useful in the diagnosis of prosthetic valve obstruction.

  • PDF

작은 기계 판막을 이용한 대도액 판막 치환술 후 판막 전후 압력차 (transprosthetic Pressure Gradient after aortic Valve Replacement with Small Sized Prostheses)

  • 황경환;박계현;차대원;전태국;박표원;채헌
    • Journal of Chest Surgery
    • /
    • 제33권2호
    • /
    • pp.146-150
    • /
    • 2000
  • background: The prognosis after an aortic valve replacment can be affected significantly by the transprosthetic pressure gradient which is determined mainly by the size of the patients body and the prosthesis used. We analyzed the hemodynamic feature of two relatively new prosthese the ATS and the evensized Medtronic-Hall(M-H) valves by measuring the transprosthetic pressure gradient in the cases where small sizes (23mm or smaller) were used. Material and method: There were 94 patients who received whom aortic valve replacement with prosthesis smaller than 23 mm from October 1994 to June 1998. In these patients the transprosthetic pressure gradient clalculated from the pressure half time during postoperative Dopper echocardiographic examination was compared between the prostheses of different sizes. The body surface area of each patient was also taken into consideration. result: The mean pressure gradient and body surface area in each group were 21.7$\pm$10.2 mmHg and 1.52$\pm$0.14m2 in ATS 19mm 11.4$\pm$6.5 mmHg and 1,57$\pm$0.20m2 in M-H 20mm 15.2$\pm$6.3 mmHg and 1.54$\pm$0.13m2 in ATS 21mm 9.3$\pm$2.5 mmHg and 1.63 $\pm$0.14m2 in M-H 22 mm and 12.9$\pm$5.3 mmHg and 1.69$\pm$0.13m2 in ATS 23mm. Conclusion: The 19mm ATS prosthesis showed significant trasprosthetic pressure gradient which is similar to the values previously reported with other bileaflet prosthesesm Close follow-up was needed in terms of exercise capacity and change in left ventiricular geometry. In patients with small aortic valve annulus the 20mm M-H valve is recomendable as an alternative to 19mm bileaflet valves because it has less pressure gradient with similar outer diameter.

  • PDF

인공심장판막의 개발 및 동물실 (Development and Animal Tests of Artificial Heart Valves)

  • 이재영
    • Journal of Chest Surgery
    • /
    • 제20권3호
    • /
    • pp.458-472
    • /
    • 1987
  • A heart supplies bloods of about 15, 000 liters to each human organ in a day. A normal function of heart valves is necessary to this act of heart. The disease of heart valve develops to a narrowness of a closure, resulting in an abnormal circulation of bloods. In an attempt to eliminate the affliction of heart valves, the operation method to repair with artificial heart valves has been developed and saved numerous patients over past 30 years. This replacement operation has been performed since early 1960`s in Korea, but all the artificial heart valves used are imported from abroad with very high costs until recent years. The artificial heart valve using pyrolytic carbon has been developed at KAIST, which was proved to be stable in the mechanical performance and durability. Therefore, the in viva performance of this valve was examined through animal tests. The artificial heart valves used in this study are tilting disc type valves, in which the disc were made of graphite coated with pyrolytic carbon and the cages were made of titanium. In viva testings of these valves were performed in 12 dogs, in which right ventriculo-pulmonary arterial [Croup I] or inter-aortic [Croup IV] valved conduit was implanted using polytetrafluoroethylene conduits containing KAIST valve and aortic valve [Group II] or pulmonary valve [Croup III] was replaced by a KAIST valve with a 21mm or 19mm tissue annulus diameter. In group I and II, pre-and post-operative transvalvular pressure gradient was measured and compared with other prosthetic valves. During post operative period laboratory examination was performed including hemoglobin, hematocrit, red cell count, white cell, lactic acid dehydrogenase and platelet. The eight surviving dogs were sacrificed and autopsy was performed at 2, 6, and 8 weeks. KAIST valve has low transvalvular gradient and relatively high orifice area. Average ventriculo-aortic peak systolic transvalvular gradient was 14 mmHg in 21 mm valve and 19 mmHg in 19 mm valve. The valve has slight intravascular hemolysis effect. Thrombogenic effect of low polishing quality and eddy currents around small orifice is high. The valve has vulnerability of disc movement. These animal tests suggest that the improvement of the heart valve design, surface polishing state and prescription methods.

  • PDF

대동맥판막하 막상협착증 치험 2례 (Discrete Membranous Subaortic Stenosis)

  • 문경훈
    • Journal of Chest Surgery
    • /
    • 제21권4호
    • /
    • pp.727-733
    • /
    • 1988
  • Two cases of the discrete membranous subaortic stenosis were experienced at the Department of Thoracic & Cardiovascular Surgery, National Medical Center, Seoul, Korea. Case I was 31 years old male with a history of aortic valve replacement[Ionescu-Shiley, 19mm] at the other hospital in 1980. Heart failure was noticed 6 years later. On cardiac catheterization, pressure gradient between left ventricle 4 aorta was 104 mmHg, but subvalvular aortic stenosis was not detected by preoperative 2-D echo <% left ventriculogram. Above case revealed stenoinsufficiency of the prosthetic valve. Under the diagnosis of the prosthetic valve failure, re-do aortic valve replacement[Bjork-Shiley, 23 mm] was done. During operation, the discrete membranous subaortic stenosis was incidentally found, and it was completely resected. So we thought that above discrete membranous subaortic stenosis was not detected at first operation, and it was progressed during 6 years, and accelerated the degeneration of the prosthetic valve. Case II was 20 years old female. Her complaints were exertional dyspnea, angina, syncope, which were aggravated since 5 years ago. 2-D echo <% left ventriculogram revealed the discrete membranous subaortic stenosis. Pressure gradient was 20 mmHg, but her symptoms were serious. Associated cardiac anomaly was the persistent left superior vena cava without connection with right superior vena cava. Complete excision of the membranous tissue was done. Post-operative pressure gradient between left ventricle & aorta was absent, and her complaints were nearly subsided. Both cases were type I according to the Newfeld classification of the discrete subvalvular aortic stenosis, and complete excision of the membranous tissue was done without myotomy or mymectomy. And short-term follow-up results[Case I:2 years, Case II: 1 ~ years] were good except soft systolic murmur[grade II/VI] at the aortic area in both cases.

  • PDF

이색 PIV 기술을 이용한 5밸브 가솔린엔진 연소실 내의 유동특성 분석 (Investigation on the In-Cylinder Flow of 5-Valve Gasoline Engine by Using Two Color PIV Method)

  • 이기형;우영완;박상찬;이창식
    • 대한기계학회논문집B
    • /
    • 제26권2호
    • /
    • pp.238-244
    • /
    • 2002
  • A 5-valve(intake 3-valve) engine has been developed to increase engine performance. These engines have a high power caused by the decrease of inertia mass of an intake valve and the increase of intake effective area. In this study, in-cylinder flow patterns were visualized with laser sheet method and velocity profiles at near intake valves were inspected by using a two-color PIV. In addition, steady flow tests were performed to quantify tumble ratio of flow-fields generated by a tumble control valve(TCV). Experimental results of steady flow test show that the cure of tumble ratio in intake 3-valve engine farmed as a S shape with valve lift changes. This tendency is different from the one in intake 2-valve engine. Using laser sheet method and two color PIV method, we can find that the intake flow through upper valve increases and the velocity gradient also slightly increases as valve lift increases. From this study, the in-cylinder flow characteristics around intake valves were made clearly.

선천성 대동맥판막 협착증 치험 1례 (Congenital Aortic Valvular Stenosis: report of a case)

  • 김병열
    • Journal of Chest Surgery
    • /
    • 제12권4호
    • /
    • pp.350-354
    • /
    • 1979
  • The incidence of congenital aortic valvular stenosis has been known rare, and approximately 3-6% of congenital heart diseases. Recently, we experienced 1 case of congenital aortic valvular stenosis, and which was corrected surgically under extracorporeal circulation successfully. A 11 years old male pt. was admitted to N.M.C. because of dyspnea, dizziness, chest pain and episode of syncope. An auscultation, harsh systolic murmur [Gr. IV/VI] was noted at aortic area and also palpable strong thrill. ECG showed LVH c strain pattern and suspicious LVH finding in simple chest P-A film. In Lt. cardiac catheterization, abrupt pressure change [110mmHg] between LV & Aorta was noted across the aortic valve. And aortic insufficiency was absent, well visualized both coronary arteries and suspicious bicuspid aortic valve in aortography. Valve form was bicuspid, large one was noncoronary cusp and another cusp was Rt. & Lt. coronary cusp which was interpositioned rudimentary commissure. Central aortic orifice was about 5ram in diameter. Valvulotomy was done along the fusioned commissure between noncoronary cusp and Rt. & Lt.coronary cusp, and then short incision was added between Rt. coronary cusp & Lt. coronary cusp. Immediate postoperative course smooth but unknown cardiac arrest was noted in POD second day. Complete recovery was done without sequelae by resuscitation. After operation, clinical symptoms were subsided but systolic murmur [Gr. II/VI] was audible at aortic area, diastolic murmur was absent. ECG showed still remained LVH but much decreased R wave voltage in Lt. precordial leads. Simple chest P-A showed no interval changes compared to preop film. Control Lt. heart catheterization revealed still remained pressure gradient [40ramrig] between LV & Aorta. But much decreased pressure gradient compared to preop pressure gradient [110mmHg].

  • PDF

Early Aortic Valve Replacement in Symptomatic Normal-Flow, Low-Gradient Severe Aortic Stenosis: A Propensity Score-Matched Retrospective Cohort Study

  • Kyu Kim;Iksung Cho;Kyu-Yong Ko;Seung-Hyun Lee;Sak Lee;Geu-Ru Hong;Jong-Won Ha;Chi Young Shim
    • Korean Circulation Journal
    • /
    • 제53권11호
    • /
    • pp.744-755
    • /
    • 2023
  • Background and Objectives: Aortic valve replacement (AVR) is considered a class I indication for symptomatic severe aortic stenosis (AS). However, there is little evidence regarding the potential benefits of early AVR in symptomatic patients diagnosed with normal-flow, low-gradient (NFLG) severe AS. Methods: Two-hundred eighty-one patients diagnosed with symptomatic NFLG severe AS (stroke volume index ≥35 mL/m2, mean transaortic pressure gradient <40 mmHg, peak transaortic velocity <4 m/s, and aortic valve area <1.0 cm2) between January 2010 and December 2020 were included in this retrospective study. After performing 1:1 propensity score matching, 121 patients aged 75.1±9.8 years (including 63 women) who underwent early AVR within 3 months after index echocardiography, were compared with 121 patients who received conservative care. The primary outcome was a composite of all-cause death and heart failure (HF) hospitalization. Results: During a median follow-up of 21.9 months, 48 primary outcomes (18 in the early AVR group and 30 in the conservative care group) occurred. The early AVR group demonstrated a significantly lower incidence of primary outcomes (hazard ratio [HR], 0.52; 95% confidence interval [CI], 0.29-0.93; p=0.028); specifically, there was no significant difference in all-cause death (HR, 0.51; 95% CI, 0.23-1.16; p=0.110), although the early AVR group showed a significantly lower incidence of hospitalization for HF (HR, 0.43; 95% CI, 0.19-0.95, p=0.037). Subgroup analyses supported the main findings. Conclusions: An early AVR strategy may be beneficial in reducing the risk of a composite outcome of death or hospitalization for HF in symptomatic patients with NFLG severe AS. Future randomized studies are required to validate and confirm our findings.

유압설계 변수에 따른 전기유압식 현가장치의 특성 (Characteristics of Electro-hydraulic Suspension According to Hydraulic Design Variables)

  • 고영호;이건복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.171-176
    • /
    • 2008
  • Active suspension controls stiffness and damping between unsprung mass and sprung mass in order to increase the ride quality. However, to increase the riding quality, the handling quality should be decreased and the rattle space should be increased. So, active suspension should cope with these conflict conditions. Therefore its actuating devices have to produce sufficient actuating force and have sufficiently short response time. In this paper, the dynamic characteristics of 1/4 car model with an active suspension is studied according to hydraulic design variables. The active suspension consists of a hydraulic servo valve and a hydraulic cylinder. It shows better performance when it has more powerful and faster actuator.

  • PDF

Postoperative Outcomes of Mitral Valve Repair for Mitral Restenosis after Percutaneous Balloon Mitral Valvotomy

  • Lee, Ji Seong;Chee, Hyun Keun;Kim, Jun Seok;Song, Myong Gun;Park, Jae Bum;Shin, Je Kyoun
    • Journal of Chest Surgery
    • /
    • 제48권5호
    • /
    • pp.328-334
    • /
    • 2015
  • Background: There have been a number of studies on mitral valve replacement and repeated percutaneous mitral balloon valvotomy for mitral valve restenosis after percutaneous mitral balloon valvotomy. However, studies on mitral valve repair for these patients are rare. In this study, we analyzed postoperative outcomes of mitral valve repair for mitral valve restenosis after percutaneous mitral balloon valvotomy. Methods: In this study, we assessed 15 patients (mean age, $47.7{\pm}9.7years$; 11 female and 4 male) who underwent mitral valve repair between August 2008 and March 2013 for symptomatic mitral valve restenosis after percutaneous mitral balloon valvotomy. The mean interval between the initial percutaneous mitral balloon valvotomy and the mitral valve repair was $13.5{\pm}7years$. The mean preoperative Wilkins score was $9.4{\pm}2.6$. Results: The mean mitral valve area obtained using planimetry increased from $1.16{\pm}0.16cm^2$ to $1.62{\pm}0.34cm^2$ (p=0.0001). The mean pressure half time obtained using Doppler ultrasound decreased from $202.4{\pm}58.6ms$ to $152{\pm}50.2ms$ (p=0.0001). The mean pressure gradient obtained using Doppler ultrasound decreased from $9.4{\pm}4.0mmHg$ to $5.8{\pm}1.5mmHg$ (p=0.0021). There were no early or late deaths. Thromboembolic events or infective endocarditis did not occur. Reoperations such as mitral valve repair or mitral valve replacement were not performed during the follow-up period ($39{\pm}16months$). The 5-year event-free survival was 56.16% (95% confidence interval, 47.467-64.866). Conclusion: On the basis of these results, we could not conclude that mitral valve repair could be an alternative for patients with mitral valve restenosis after percutaneous balloon mitral valvotomy. However, some patients presented with results similar to those of mitral valve replacement. Further studies including more patients with long-term follow-up are necessary to determine the possibility of this application of mitral valve repair.

대동맥판폐쇄부전을 동반한 국소성 (A Case of Localized Subaortic Stenosis Associated with Aortic Regurgitation)

  • 김삼현;서필원
    • Journal of Chest Surgery
    • /
    • 제29권7호
    • /
    • pp.780-784
    • /
    • 1996
  • 국소성 대동맥하협착은 뚜렷한 막성(discretemembraneous)에서 광범위한 터널형 협착에 이르는다 양한 병변을 보이며 드물지 않게 대동맥팥폐쇄부전이 동반된다. 이러한대동맥하협착과대동맥판폐쇄 부전은 시간이 경과함에 따라 진전되는 것으로 알려져 있으므로 조기수술이 고려되어야 한다. 븐 병 원에서는 중등도의 대동맥 판폐쇄부전이 동반된 국소성 대동맥하협착 환자 1례를 치헙하여 좋은 결과를 얻었다. 수술은 대동맥 판륜 하부의 섬유근성조직 (fibromuscular tissue)을 절제하고 비후된 심실중격에 근절제 및 근절개를 병 행 하였으며, 대동맥 판성 형술 및 교련하부판륜성 형술로 대동맥 판폐 쇄부전을 교정하였 다. 퇴 원 당시의 심장초음파검사에서 좌심실-대동맥간 수축기 압력 차이가 술전에 비 해 현저히 감소하였고 대동맥판폐쇄부전의 소견은 보이지 않았다.

  • PDF