• 제목/요약/키워드: Valve angle

Search Result 244, Processing Time 0.027 seconds

Isokinetic Evaluation of Trunk Flexors and Trunk Extensors in Normal Adult Subjects and Patients with Post-operative Herniated Intervertebral Lumbar Disc (정상 성인남자와 요추간판탈출증 수술후 성인남자의 요추부 굴곡근 및 신전근의 등속성 근력평가)

  • Oh Seung-Kil
    • The Journal of Korean Physical Therapy
    • /
    • v.10 no.1
    • /
    • pp.81-98
    • /
    • 1998
  • Isokinetic evaluation of trunk flexors and trunk extensors was performed at $60^{\circ}/sec\;and\;120^{\circ}/sec$ of angular velocity by using cybex 6000TEF Unit on 31 healthy male white workers and 15 post-operative HILD patients with no significant difference in mean age and mean body weight between two groups, and compared each other. The purpose of this study is to obtain the isokinetic normative strength values and endurance latins for Dunk extensors and trunk flexors, and is to provide a guideline for rehabilitation program of post-operative HILD patients. The collected data were analyzed by ANOVA, Duncan's Nyktuoke Range Test, and Pearson correlation coefficiency in PC-SAS program, The results obtained were as follow ; 1. Post-operative subjects has lower isokinetic values than normal subjects in peak torque, peak torque $\%$ by body weight, total work, total work $\%$ by body weight, average power, average power $\%$ by body weight, TAAE of trunk flexors and trunk extensors, and there are significant differences with statistic value in trunk extensors at $60^{\circ}/sec$ and in trunk flexors and trunk extensors at $120^{\circ}/sec$ between two groups(p<0.05). 2. Pest-ooperative subjects has lower values for angle of peak torque than normal subjects in trunk extensors, and there are significant differences with statistic value at $60^{\circ}/sec$ and $120^{\circ}/sec$ between two groups. 3. Post-operative subjects has higher values for endurance ratios than normal subjects in trunk extensors and flexors, but there are no significant differences with statistic value between two groups. 4. Post-operative subjects has higher values than normal subjects in peak torque ratios, total work ratios, average power ratios of trunk flexors to trunk extensors, and there are significant differences with statistic value between two groups(p<0.01). 5. There is significant positive-correlation with statistic valve between peak torque and height and body weight in normal subjects(p<0.05), but Thjere is significant negative-correlation between peak torque of trunk extensor at $120^{\circ}/sec$ and age (p<0.05). 6. There is significant positive-correlation with statistic value between peak torque of trunk flexors and body weight in post-operative subjects (p<0.05), but There is significant negative-correlation between peak torque of trunk extensor add age (p<0.05). In conclusion, post-operative subjects have greater weakness in trunk musculature than normal subjects, especially there is more significant weakness in trunk extensors than in trunk flexors

  • PDF

Automation of Longline -Automation of the Alaska Pollack Longline- (주낙어구의 자동화 -명태주낙어업의 자동화-)

  • KO Kwan-Soh;YOON Gab-Dong;LEE Chun-Woo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.20 no.2
    • /
    • pp.106-113
    • /
    • 1987
  • The Alaska pollack longline operations, which consist of baiting, shooting, hauling and arrangement of hooks, are dependant on manual labour up to the present. The automation against this traditional way is necessary to eliminate the manual operations and to reduce crew. We have developed a prototype longline system suitable for Alaska pollack longline gear, which is composed of an automatic baiting machine, an automatic line hauler, a hook cleaner and storage rails. The automatic bailing machine driven by hydraulic power is precise baiting method controlled sequentially, and the automatic line hauler is to haul up the mainline by means of hydraulic power and at the same time to split every hook and to carry it onto storage rail automatically. A series functioning tests on shooting and hauling apparatus were carried out in the laboratory and at sea. The results obtained are as follows ; 1. As for the baiting machine, the exciting time of solenoid which operates a directional valve, bait feeding and cutting time, is shortened according to the increase of pressure, and also, after cutting the bait, the over-rotated angle of the blade increased in accordance with the increase of pressure. 2. The baiting efficiency is about $90\%$ when using sand lance (Hypoptychus dybowskii), and the most proper pressure of the hydraulic circuit in feeding and cutting the bait is between $13\;kgf/cm^2\;and\;20\;kgf/cm^2$. 3. The hook splitting rate of the automatic line hauler is about $95.5\%$ regardless of hauling speed and materials of snood. 4. The case of unseparating hook is appeared when the snood gets entangled or the hook is sticked in the mainline.

  • PDF

Triangular Resection of the Upper Lateral Cartilage for Middle Vault Deviation

  • Ryu, Gwanghui;Seo, Min Young;Lee, Kyung Eun;Hong, Sang Duk;Chung, Seung-Kyu;Dhong, Hun-Jong;Kim, Hyo Yeol
    • Clinical and Experimental Otorhinolaryngology
    • /
    • v.11 no.4
    • /
    • pp.275-280
    • /
    • 2018
  • Objectives. Middle vault deviation has a significant effect on the aesthetic and functional aspects of the nose, and its management continues to be a challenge. Spreader graft and its modification techniques have been focused, but there has been scarce consideration for removing surplus portion and balancing the upper lateral cartilage (ULC). This study aimed to report the newly invented triangular-shaped resection technique ("triangular resection") of the ULC and to evaluate its efficacy for correcting middle vault deviation. Methods. A retrospective study included 17 consecutive patients who presented with middle vault deviation and underwent septorhinoplasty by using triangular resection at a tertiary academic hospital from February 2014 and March 2016. Their outcomes were evaluated pre- and postoperatively including medical photographs, acoustic rhinometry and subjective nasal obstruction using a 7-point Likert scale. Results. The immediate outcomes were evaluated around 1 month after surgery, and long-term outcomes were available in 12 patients; the mean follow-up period was 9.1 months. Nasal tip deviation angle was reduced from $5.66^{\circ}$ to $2.37^{\circ}$ immediately (P<0.001). Middle vault deviation also improved from $169.50^{\circ}$ to $177.24^{\circ}$ (P<0.001). Long-term results were $2.49^{\circ}$ (P=0.015) for nasal tip deviation and $178.68^{\circ}$ (P=0.002) for middle vault deviation. The aesthetic outcome involved a complete correction in eight patients (47.1%), a minimally visible deviation in seven patients (41.2%) and a remaining residual deviation in two patients (11.8%). Pre- and postoperative minimal cross-sectional areas (summation of the right and left sides) were 0.86 and 1.07, respectively (P=0.021). Fifteen patients answered about their nasal obstruction symptoms and the median symptom score had alleviated from 6.0 to 3.0 (P=0.004). Conclusion. Triangular resection of the ULC is a simple and effective method for correcting middle vault deviation and balancing the ULCs without complications as internal nasal valve narrowing.

Anatomical Structures of the Aortic Root in Koreans (한국인 대동맥 근부의 해부학적 구조)

  • Kang, Min-Woong;Yu, Jae-Hyeon;Lim, Seung-Pyung;Lee, Young;Kim, Si-Wook;Kim, Su-Il;Chung, In-Hyuk;Na, Myung-Hoon
    • Journal of Chest Surgery
    • /
    • v.40 no.5 s.274
    • /
    • pp.321-328
    • /
    • 2007
  • Background: It is very important to determine the surgical anatomy of the aortic root when performing spreading aortic root preserving heart surgery. This study focuses on the surgical aspect of the aortic root anatomy by performing dissection of Korean cadavers. Material and Method: The subjects were 62 cadavers. We measured the intercommissural distances, heights of the sinuses and the circumference of the sinotubular junction and the aortic annulus. Result: The mean age of death was 61.3 years. The intercommissural distance for the right coronary sinus was $0.73{\pm}2.23mm$, that for the non coronary sinus was $19.34{\pm}2.03mm$, and that for the left coronary sinus was $18.58{\pm}2.15mm$. The height of sinus was $20.59{\pm}2.48mm$ for the right coronary sinus, $18.61{\pm}2.26mm$ for the non coronary sinus and $17.95{\pm}19mm$ for the left coronary sinus. The circumference of the sinotubular junction was $70.73{\pm}5.94mm$ and that of the aortic annulus was $77.94{\pm}5.63mm$. There is no correlation between age and STJ, aortic annulus and the ratio of STJ of aortic annulus respectively (p=0.920, p=0.111, p=0.073). The tilting angle of the sinotubular junction and aortic annulus is from $2.03^{\circ}$ to $7.77^{\circ}$ $(mean=4.90^{\circ})$. Conclusion: The intercommissural distance and the height of the sinus were largest in the right coronary sinus, and the position of the sinotubular junction to the aortic annulus is obliquely tilted levo-posteriorly.