• Title/Summary/Keyword: Valve Block

Search Result 124, Processing Time 0.027 seconds

Wear Property of SACM645 Material with DLC Coating (DLC 코팅된 SACM645 소재의 마모 특성)

  • Kim, Nam-Soek;Nam, Ki-Woo;Park, Jong-Nam;Ahn, Seok-Hwan;Kim, Hyun-Soo
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.6
    • /
    • pp.76-80
    • /
    • 2010
  • Oil hydraulic piston pumps are being extensively used around the world, because of their simple design, light weight, effective cost, etc. An oil hydraulic pump is likely to have the serious problems of high leakage, friction, and low energy efficiency after a long period of use. In an oil hydraulic piston pump, the clearance between the valve block and piston plays an important role for volumetric and overall efficiency. In this study, the wear property of the SACM645 material with DLC coating used for a hydraulic piston pump was determined by experimentation with variable heat treatment. To investigate the effect according to the piston surface condition, five different types of specimens were prepared. The maximum tensile strengths of the QT and QT Nitration specimens had similar values of about 800 MPa, but the strains indicated a big difference. In a wear test, the wear characteristic of the DLC coating specimen was shown to be excellent. The QT, QT + IH, QT + Nitration, and matirx specimen showed similar wear characteristics. In the case of a dry condition without oil, the DLC coating specimen had good wear resistance, with no wear shown.

Study on Fatigue Property of Material for Oil Hydraulic Piston Pump (유압 피스톤 펌프 소재의 피로특성 연구)

  • Kim, Nam-Seok;Nam, Ki-Woo;Kim, Hyun-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.5
    • /
    • pp.555-559
    • /
    • 2011
  • Oil hydraulic piston pumps are extensively used worldwide because of their simple design, light weight, and cost effectiveness. However, an oil hydraulic pump is likely to have high leakage, friction, and low energy efficiency after long-term use. In oil hydraulic piston pumps the clearance between the valve block and the piston plays an important role in the volumetric and overall efficiency. We studied the wear property of the SACM645 material used in hydraulic piston pumps via experiments with different heat treatments. We prepared three different specimens. The maximum tensile strengths of the QT and QT-nitration specimens are similar (about 820 MPa), but the strains are significantly different. However, the fatigue characteristic depended on the heat treatment.

Chemisorption of CO on ultrathin epitaxial Ni films n Cu(001) surface

  • E.K. Hwang;J.J. Oh;Lee, J.S.;Kim, S.K.;Kim, J.S.;Kim, J.S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.182-182
    • /
    • 1999
  • The chemisorption effect of CO on the Ni/Cu(001) surface was investigated using LEED(Low Energy Electron Diffraction) and EELS(Electron Energy Loss Spectrscopy0 under the UHV conditions. after mounting the Cu(001) single crystal in the UHV chamber (base pressure 1$\times$10-10Torr), a clean surface was obtained after a few cycles of repeated Ar+ ion sputtering and annealing at about 40$0^{\circ}C$. The epitaxial thin Ni films were formed on the Cu(001) by evaporation from 99.999% Ni block. The pseudomorphic growth and the orderness of the thin Ni films were monitored by c(2$^{\circ}C$2) LEED pattern. CO adlayers on Ni epitaxial thin films were prepared by dosing pure CO has through a leak valve. After CO adsorpton at room temperature, two pairs of peaks were observed by EELS, whose relative intensities are changed as the film thickness is varied and time is elapsed. These two pair of peaks are likely related to different bonding sites (-top and bridge sites) of C-Ni as well as C-O vibration. Experimental results and qualitative interpretation of the spectra wille be discussed. The possibility of using EELS in combination with probe species (CO) to investigate the nature of thin film growth is mentioned. We will report the experimental result of O2 dosage on Ni film and interaction of CO and O2.

  • PDF

Design consideration and explosion safety of underground ammunition storage facilities (지하탄약고의 설계요소 및 폭발안전 연구)

  • Kim, Oon-Young;Lee, Myung-Jae;Kim, Min-Seok;Kim, Joon-Youp;Joo, Hyo-Joon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.5 no.1
    • /
    • pp.55-70
    • /
    • 2003
  • Ammunition magazine, which is installed on the ground, has difficulty in protecting from the external attack, and accidental explosion should cause great damage to the life and property. For these reasons, it is needed to develop underground magazine that it has the advantages of safety, security and maintenance. This paper introduce the design case for blasting facilities, which should resist blasting pressure, as well as layout of underground magazine, which takes a safety for explosion and a working space of loading/unloading machine into consideration. On the layout, in case of ${\bigcirc}{\bigcirc}$ underground magazine, put three storage chambers in position almost parallel with principle stress direction, where less effected on discontinuity and hard rock area. Also, secured safe distance according to safety criteria of the Defense Ministry, and verified suitable layout by trace simulation for loading/unloading machine on working stage. Blasting design was performed on evaluation of maximum blast pressure between donar and acceptor chambers, and design condition for blast door, valve, etc. Diminution facilities against explosion, such as thrust block or debris trap, determined its size after plan in accordance with blasting criteria and calculation by structural analysis.

  • PDF

A Study of the Variation in Intensifier Performance Characteristics Varying with Pressure and Temperature (압력·온도 변화에 따른 초고압 발생기 성능특성 연구)

  • Kim, Hyoung-Eui;Lee, Gi-Chun;Kim, Jae-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.9
    • /
    • pp.1249-1255
    • /
    • 2010
  • An ultra high- pressure system generally consists of a hydraulic power unit, an oil supply unit, an electrical power supply device, and an electrical control device. The hydraulic power unit supplies the hydraulic power to the intensifier to create generate ultra high pressure. The intensifier amplifies increases the pressure using the oil supplied from by the hydraulic power unit. The electrical supply devices and control devices maintain are provided for the electric motors, valves, and sensors. In this study, instead of a flow-control device, a pressure-control type device was mounted on a manifold block in the hydraulic power unit instead of the flow-control type. A servo valve was fitted in the intensifier, and the performance characteristics of the intensifier varied according to the variations of in the pressure cycle and with the temperature of the operating oil in the hydraulic power unit.

Heart Sound Recognition by Analysis of Block Integration and Statistical Variables (구간적분과 통계변수 분석에 의한 심음 인식)

  • 이상민;김인영;홍승홍
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.6
    • /
    • pp.573-581
    • /
    • 1999
  • Although phonocardiography by auscultation has been used in diagnosis long time ago, recognition of heart sound was tried only restricted fields such as the first heart sound, the second heart sound, and specific valve operation for the purpose of analyzing local function or operation of heart and developments of heart sound recognition in full cycle are quite insignificant. in this paper, we proposed a recognition method which extracts features of heart sound in full cycle and classllies heart sounds This proposed recognition algorithm is based on detecting the first and second heart sounds in thme domain. The algorithm classifics heart sound into several classes by extracting the important time blocks and analyzing the peak position, integration values and statistical variables. Heart sounds are classified into normal, early systolic murmur, late systolic mumur, early diastolic murmur, late diastolie murmur, continuous murmur. We can verify our algorithm is useful from the results which show the average recognition rate of heart sounds is 88 perecnt. Recognition error was occurred mainly in early systolic murmur.

  • PDF

A novel FBN1 gene mutation associated with early-onset pneumothorax in Marfan syndrome

  • Park, Min Ji;Lee, Dong Hun;Shin, Young Lim;Hong, Yong Hee
    • Journal of Genetic Medicine
    • /
    • v.13 no.1
    • /
    • pp.41-45
    • /
    • 2016
  • Marfan syndrome (MFS) is an inherited connective tissue disorder with a mutation in the fibrillin-1 (FBN1) gene. Fibrillin is a major building block of microfibrils, which constitute the structural component of the connective tissues. A 10-year-old girl visited our hospital with the chief complaint of precocious puberty. According to her medical history, she had a pulmonary wedge resection for a pneumothorax at 9 years of age. There was no family history of MFS. Mid parental height was 161.5 cm. The patient's height was 162 cm (>97th percentile), and her weight was 40 kg (75th-90th percentile). At the time of initial presentation, her bone age was approximately 11 years. From the ophthalmologic examination, there were no abnormal findings except myopia. There was no wrist sign. At the age of 14 years, she revisited the hospital with the chief complaint of scoliosis. Her height and weight were 170 cm and 50 kg, respectively, and she had arachnodactyly and wrist sign. We performed an echocardiograph and a test for the FBN1 gene mutation with direct sequencing of 65 coding exons, suspecting MFS. There were no cardiac abnormalities including mitral valve prolapse. A cytosine residue deletion in exon 7 (c.660delC) was detected. This is a novel mutation causing a frameshift in protein synthesis and predicted to create a premature stop codon. We report the case of a patient with MFS with a novel FBN1 gene missense mutation and a history of pneumothorax at a young age without cardiac abnormalities during her teenage years.

Long-term Result after Repair of Sinus Valsalva Aneurysm Rupture (발살바동류 및 파열의 수술 후 장기 성적)

  • Lim, Sang-Hyun;Chang, Byung-Chul;Joo, Hyun-Chul;Kang, Meyun-Shick;Hong, You-Sun
    • Journal of Chest Surgery
    • /
    • v.38 no.10 s.255
    • /
    • pp.693-698
    • /
    • 2005
  • Background: Sinus valsalva aneurysm (SVA) is a rare disease, and it is frequently accompanied by ventricular septal defect and aortic valve regurgitaion. For treatment of SVA, several surgical mordalities were applied, but there was no report on the long-term result after surgical repair in Korea. We reviewed our 28 years of experiences and analyzed the long-term results after treatment of sinus valsalva aneurysm with or without rupture. Material and Method: Between March 1974 and February 2002, 81 patients were operated under the impression of sinus valvsalva aneurysm or sinus valsalva aneurym rupture. Retrospectively we reviewed the patients' record. Mean age of patients was $29.2\pm11.5$ and there were 49 males. Accompanyng diseases were as follows: VSD in 50, PDA in 2, Behcet's disease in 2, TOF in 1, RVOTO in 1, AAE in 1. Seventy-seven $(95\%)$ patients had sinus valsalva rupture and in 14 patients, subacute bacterial endocarditis was accompanied. Degree of aortic valve regurgitation was as follows: grade I: 8, II: 10, III: 9, IV: 4. Most common rupture site was right coronary sinus (66 patients, $81\%$) and most common communication site was right ventricle (53 patients). In repair of sinus valsalva rupture, patch was used in 37 patients, and direct suture was done in 38 patients. Result: There was one surgical death $(1.2\%)$. Follow up was done in 78 patients $(97.5\%)$, mean follow up period was $123.3\pm80.9(3\~330\;months)$. During the follow up period, 3 patients died $(3.8\%)$. One patient died of heart failure, another patient died of arrhythmia and the other one died of unknown cause. In two patients, complete atrio-ventricular block was developed during follow up period, and there was no operation related event or complication. Kaplan-Meier survival analysis revealed $92.5\pm3.5\%$ survival at 15 and 27 years and it seems to be satisfactory. Conclusion: Long-term surgical results and survival is satisfactory after repair of sinus valsalva aneurysm with or without rupture.

The Early Results of Tricuspid Valvuloplasty with Using the Edwards MC3 Annuloplasty System (Edwards MC3 Annuloplasty System을 이용한 삼첨판 성형술의 조기 성적)

  • Oh, Tak-hyuck;Cho, Joon-Yong;Lee, Jong-Tae;Kim, Gun-Jik;Kim, Dae-Hyun
    • Journal of Chest Surgery
    • /
    • v.42 no.1
    • /
    • pp.28-33
    • /
    • 2009
  • Background: Functional tricuspid regurgitation (TR) greater than or equal to a mild grade requires tricuspid valvuloplasty, and tricuspid valvuloplasty with ring annuloplasty has shown good outcomes. We report here on our early experience with the Edwards $MC^3$ annuloplasty system (Edwards LifeSciences, Irvine, CA). Material and Method: From November 2004 to July 2006, 72 patients with tricuspid annular dilatation and TR underwent tricuspid valvuloplasty with using the Edwards $MC^3$ annuloplasty ring. Sixty-eight patients were operated on via median sternotomy and four patients were operated on using robotic assisted minimal invasive thoracotomy. The patient population included 21 males and 51 females and their mean age was $53.9{\pm}12.3$. The mean grade of TR, as assessed by the preoperative echocardiography, was $2.2{\pm}1.0$. The mean NYHA functional class was $3.1{\pm}0.8$. The mean left ventricular ejection fraction was $57.0{\pm}9.9$%. Result: The TR and NYHA functional class, as assessed by postoperative echocardiography, was significantly reduced (mean=$0.4{\pm}0.6$ and $2.0{\pm}0.7$, respectively p<0.001). There was one case of hospital mortality. One patient required permanent pacemaker insertion for third degree atrioventricular block. Conclusion: Our study shows that the Edwards $MC^3$ remodeling ring is easy to implant and it effectively corrects functional TR with excellent clinical and echocardiographic outcomes. Further follow-up and a larger clinical series are required to establish the long-term stability of this repair technique.

Clinical Features of Isolated Noncompaction of the Ventricular Myocardium (심근의 단독 비경화증(Isolated Noncompaction of Ventricular Myocardium)의 임상 양상)

  • Moon, Eun-Kyoung;Lee, Hoon-Young;Chang, Mea-Young;Kil, Hong-Ryang;Chung, Yong-Hun
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.12
    • /
    • pp.1528-1533
    • /
    • 2002
  • Purpose : Isolated noncompaction of the ventricular myocardium(INVM) is one of the unclassified cardiomyopathies that is characterized by numerous, excessively prominent trabeculations, and deep intertrabecular recesses. We performed this study to evaluate the clinical features of INVM in children. Methods : The medical records of 10 patients with INVM were reviewed. We analyzed the clinical manifestations, hemodynamics, pattern of inheritance, and long-term prognosis of INVM in children. Results : Age at diagnosis was $45{\pm}53months$(1 day-14 years) with follow-up lasting as long as 78 months. Most INVM was asymptomatic on diagnosis. Associated cardiac anomalies were noted in six patients(ventricualr or atrial septal defect, patent ductus arteriosus with mitral valve prolapse, or mitral valve cleft). Depressed or flat changes of T wave in lead II, III and aVF were observed on electrocardiography. Various arrhythmia including WPW syndrome with paroxysmal supraventricular tachycardia, third-degree atrioventricular block, and familial sick sinus node dysfuction were observed. The degree of trabeculation in INVM was significantly prominent from level of mitral valve to apex compared to age-matched control. Familial recurrences were noted in two patients. The systolic function of the left ventricle was decreased in 20% of patients during the follow-up period, but systemic embolism or ventricular tachycardia was not observed. Conclusion : INVM is not a rare disorder. The cardiac function may be deteriorated in children as well as adults during long-term follow up. Thus early diagnosis and long-term follow-up must be done. So, the nation-wide multicenter clinical study would be mandatory to evaluate the incidence, long-term prognosis, and establishment of objective diagnostic criteria of INVM.