• Title/Summary/Keyword: Valley Following algorithm

Search Result 2, Processing Time 0.017 seconds

Development of a Semi-automatic Search Program for Crown Delineation Based on Watershed and Valley Following Algorithms

  • Sim, Woodam;Park, Jeongmook;Lee, Jungsoo
    • Journal of Forest and Environmental Science
    • /
    • v.34 no.2
    • /
    • pp.142-144
    • /
    • 2018
  • This paper discusses the development of semi-automatic search program for crown delineation in stand level. The crown of an individual tree was delineated by applying the Watershed (WS) and Valley Following (VF) algorithms. Unmanned Aerial Vehicle (UAV) images were used in the semi-automatic search program to delineate the crown area. The overall accuracy and Khat were used in accuracy assessment. WS algorithm's model showed the overall accuracy and Khat index of 0.80 and 0.59, respectively, in Plot 1. However, the overall accuracy and Khat of VF algorithm's model were 0.78 and 0.51, respectively, in Plot 2.

Signl processing method and diagnostic algorithm for arterial oxygen-saturation measument (산소포화도 측정을 위한 신호처리방법 및 계산 알고리즘)

  • 김수진;황돈연;전계진;이종연;정성규;윤길원
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.6
    • /
    • pp.452-456
    • /
    • 2000
  • A measurement unit and signal processing algorithm have been developed for predicting arterial oxygen saturation noninvasively. The measurement set-up was composed of a probe including light source and photodetector, optical signal processing section, LED driving circuit, PC interface software for data acquisition and data processing software. Light from the LED's was irradiated onto the finger nail bed and transmitted light was measured at different wavelengths. An effective baseline correction method was developed and measured data were analyzed by using various data processing methods and prediction algOlithms. For performance evaluation, a pulse oximeter simulator (Bio- Tek Instrument Inc.) was used as reference. The best performance in terms of the correlation coefficient and the standard deviation was obtained under the following conditions; when the arterial signals were computed in terms of area rather than peak-valley difference, and when the algorithm calculating by $In(I_p/I_v)/I_{avr}$ value for pulsation waveform was used. In in vivo test, prediction was improved when the developed baseline correction method was used. In addition, wavelengths of 660 nm and 940 nm provided better linearity and precision than wavelengths of 660 nm and 805 nm. 05 nm.

  • PDF