• Title/Summary/Keyword: Vacuum therapy

Search Result 56, Processing Time 0.018 seconds

Tracheobronchial Foreign Body in a Shih-tzu Dog; Diagnostic and Therapeutic Trial Using Bronchoscopy (시츄견에서 발생한 기관기관지 이물의 기관지경을 통한 진단적 및 치료적 적용 증례)

  • Park, Chul;Yoo, Jong-Hyun;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.26 no.4
    • /
    • pp.336-339
    • /
    • 2009
  • A 4-year-old, neutered male Shih-tzu dog weighing 5.4 kg was referred due to anorexia and chronic coughing. Based on history, physical examination, laboratory tests, radiographic findings, echocardiography, and bronchoscopic examination, the dog was diagnosed as tracheobronchial foreign body. The foreign body was steamed rice debris, which was removed by bronchoalveolar lavage (BAL) with vacuum suction of bronchoscopy. Bacterial and fungal culture of collected BAL fluid was negative. Baermann test for lungs parasites also was negative. The dog was treated with bronchodilator, antibiotics, anti-inflammatory agent, and mucolytics for 7 days. Appetite increased and coughing sign was clearly improved after removal of foreign body and medical therapy. This case report describes that bronchoscopic techniques are available for the evaluation and management of airway foreign bodies.

Preparation and properties of glass fiber-reinforced endodontic (root canal therapy) posts (유리섬유 강화 근관치료 포스트의 제조 및 특성에 대한 연구)

  • Son, Jae-Yong;Kim, Kyoung-Ja;Kim, Kyoung-Hun;Park, Joo-Seok;Shim, Kwang-Bo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.25 no.3
    • /
    • pp.105-110
    • /
    • 2015
  • The fiber-reinforced endodontic posts were prepared using a photocurable resin and a glass fiber. The mechanical property of the posts increased with increasing density of glass fiber and the micro-pores in the post were removed by a vacuum impregnation process. To improve the interfacial adhesion between glass fiber and polymer, silane coupling agent was used. The surface treatment of glass fiber increased the surface wettability of resing on glass fiber and increased the adhesion property with resin, consequently improved the mechanical property of posts.

A study of the Mori Radicis Cortex pre-treatment on transient ischemic brain injury in mice (상백피(桑白皮) 메탄올 추출물 전처치가 일과성 허혈에 의한 생쥐의 뇌 손상에 미치는 영향)

  • Chung, Byung-Woo;Lim, Jae-Yu;Lee, Se-Eun;Lee, Byoungho;Lim, Sehyun;Lim, Chiyeon;Cho, Suin
    • The Korea Journal of Herbology
    • /
    • v.32 no.1
    • /
    • pp.25-31
    • /
    • 2017
  • Objectives : Mori Radicis Cortex (MRC), the root epidermis of Morus alba L., has been traditionally used to treat lung-related diseases in Korean Medicine. The common of MRC is Mulberry bark Morus bark, and it's pharmaceutical properties and taste are known as sweet and cold, and it promotes urination and reduce edema by reducing heat from the lungs and soothe asthma. In the present study, anti-apoptotic mechanism of MRC in middle cerebral artery occlusion (MCAO) model in mice. Methods : Two-hundred grams of MRC was extracted with methanol at room temperature for 5 days, and this was repeated one time. After filtration, the methanol was removed using vacuum evaporator, then stored at $-20^{\circ}C$ until use. C57BL/6 male mice were housed in an environment with controlled humidity, temperature, and light cycle. In order to determine beneficial effects of MRC on ischemia induced brain damage, infarct volume, neurological deficit scores, activities of several apoptosis-related proteins such as caspase-8, -9, Bcl-xL in MCAO-induced brains of mice were analyzed. Mice in MRC-treated groups were orally administered 30, 100, or 300 mg/kg of body weight for three consecutive days before commencing the MCAO procedure. Results : Pre-treatment of MRC significantly reduced infarct volume in MCAO subjected mice applied with 300 mg/kg of MRC methanol extract, and MRC effectively inhibited Bcl-xL reduction and caspase-9 activation caused by MCAO-induced brain damage. Conclusions : MRC showed neuro-protective effects by regulating apoptosis-related protein signals, and it can be a potential candidate for the therapy of ischemia-induced brain damage.

Preliminary Results of Stereotactic Radiosurgery Using Stereotactic Body Frame (정위 체부 고정틀을 이용한 체부 방사선수술의 예비적 결과)

  • Ahn Seung Do;Yi Byong Yong;Choi Eun Kyung;Kim Jong Hoo;Nho Young Ju;Shin Kyung Hwan;Kim Kyoung Ju;Chung Won Kyun;Chang Hyesook
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.251-256
    • /
    • 2000
  • Purpose : To evaluate efficacy and complication of stereotactic radiosurgery using stereotactic body frame. Methods and Materials :From December 1997 to June 1999, 11 patients with primary and metastatic tumors were treated with stereotactic radiosurgery using stereotactic body frame(Precision TherapyTu). Three patients were treated with primary hepatoma and seven with metastatic tumor from liver, lung, breast, trachea and one with arteriovenous malformation on neck. We used vacuum pillow for immobilization and made skin marker on sternum and tibia area with chest marker and leg marker. Diaphragm control was used for reducing movement by respiration. CT-simulation and treatment planning were peformed. Set-up error was checked by CT-Simulator before each treatment. Dose were calculated on the 80$\~$90$\%$ isodose of isocenter dose and given consecutive 3 fractions for total dose of 30 Gy (10 Gy/fraction). Results :Median follow-up was 12 months. One patient (9$\%$) showed complete response and four Patients (36$\%$) showed partial response and others showed stable disease. Planning target volumes (PTV) ranged from 3 to 111 cc (mean 18.4 n). Set-up error was within 5 mm in all directions (X, Y, Z axis). There was no complication in all patients. Conclusion :In Primary and metastatic tumors, stereotactic body frame is very safe, accurate and effective treatment modality.

  • PDF

Effect of Carbon Couch Side Rail and Vac-lok In case of Lung RPO irradiation (Lung RPO 선량전달시, Carbon Couch Side Rail과 Vac-lok이 미치는 영향)

  • Kim, Seok Min;Gwak, Geun Tak;Lee, Seung Hun;Kim, Jung Soo;Kwon, Hyoung Cheol;Kim, Yang Su;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.27-34
    • /
    • 2018
  • Purpose : To evaluate the effect of carbon couch side rail and vacuum immobilization device in case of lung RPO irradiation. Materials and Methods : The 10, 20, 30 mm thickness of vac-lok's right side were obtained. To measure of doses, glass dosimeters were used and measured reference point is left lung center at the phantom. A, B, C, and D points are left, right, down, and up directions based on the center point. In the state of Side-Rail-Out, place the without vac-lok, with the thickness of 10, 20, and 30 mm vac-lok. After the glass dosimeters was inserted in center, A, B, C, and D points, 100 MU of 6 MV X-ray were irradiated to the referenced center point in the condition of $10{\times}10cm^2$ field size, SAD 100 cm, gantry angle 225, 300 MU/min dose rate. Five measurements were made for each point. In the state of Side-Rail-In, five measurement were made for each point under the same conditions. The average is measured on each of the five Side-Rail-Out and Side-Rail-In measurements. Results : In the presence of side rail, the dose reduction ratio was -11.8 %, -12.3 %, -4.1 %, -12.3 %, -7.3 % for each A, B, C, and D points. In the state of Side-Rail-Out, the dose reduction ratio for the using 10 mm thickness of vac-lok was -0.9 % than without vac-lok. The dose reduction ratio for the using 20 mm thickness of vac-lok was -2.0 %, for the using 30 mm thickness of the vac-lok was -3.0 % than without vac-lok. In the state of Side-Rail-In, the dose reduction ratio for the using 10 mm thickness of vac-lok was -1.0 % than without vac-lok. The dose reduction ratio for the using 20 mm vac-lok was -2.1 %, for the using 30 mm vac-lok was -3.0 % than without vac-lok. Based on the value of no vac-lok dose in the Side-Rail-In state, The dose reduction ratios for the using 10 mm, 20 mm and 30 mm thickness of vac-loks In the Side-Rail-Out that the center point were -12.7 %, -13.7 %, -14.2 % and -12.8 %, -13.8 %, -14.5 % respectively at point A. The dose reduction ratios for the same conditions to the B point were -4.9 %, -6.1 %, -7.1 % and -13.4 %, -14.4 %, -15.5 % respectively at point C. The dose reduction ratios for the same conditions to the D point were -8.4 %, -9.0 %, -10.4 % respectively. Conclusion : The attenuation was caused by presence of side rails and thickness of vac-lok. Pay attention to these attenuation factors, making it a more effective radiation therapy.

  • PDF

A study of $Smartpeg^{TM}'s$ lifetime according to sterilization for implant stability (임플랜트 안정성을 위한 자기공명막대의 소독방법에 따른 수명에 관한 연구)

  • Won, Ho-Yeon;Cho, In-Ho;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.42-52
    • /
    • 2008
  • Purpose: Resonance Frequency Analysis(RFA) technique can be used as an effective method in measuring the implant stability and documenting the clinical results. This technique also determines how stable the implant is before performing a prosthetic practice. Having become one the guidelines of the implant therapy whose final objective is the immediate loading, the $Osstell^{TM}$ mentor is giving a lot of information to the clinicians recently. In this communication, experiments were performed to investigate how reliable the measured ISQ values by $Osstell^{TM}$ mentor are, and to see if those are also stable even after sterilization. As five objectives: 1) How stable measured ISQ values after fixation $Smartpeg^{TM}s$ for 400 times. 2) How stable measured ISQ values after 'attach-detach'$Smartpeg^{TM}'s$ for 400 times. 3) How stable measured ISQ values after clinical sterilization methods. 4) How stable measured ISQ values after repeatedly sterilization in autoclave for 10 times. 5) What is the critical temperature which is lost the magnetism of $Smartpeg^{TM}$. Materials and Methods: Clinical sterilization methods(Autoclave sterilization, Dentistar sterilization, Ultra violet sterilization, Vacuum dry unit sterilization, Boiling water sterilization, combined $H_{2}O_{2}$ and Alcohol sterilization).$Smartpeg^{TM}s$. D3 Block bone($3{\times}9{\times}2cm$). Osstem implant(${\emptyset}4.1$-10mm).$Osstell^{TM}$ mentor. Individual experiment was used 8 number of $Smartpeg^{TM}s$ and they had measured to ISQ values of before experiment and after experiment. Results: 1. The measured ISQ values did not change after fixation $Smartpeg^{TM}s$ for 400 times. 2. There was no significant changes in the measured ISQ values of 'attach-detach $Smartpeg^{TM}s'$ for 400 times. 3. The measured ISQ values did not change after the usual clinical sterilization methods. 4. The measured ISQ values did not change after sterilization in autoclave for 10 times. 5. It was impossible to exactly measure the critical temperature which is lost the magnetism of $Smartpeg^{TM}s$. But, the results was resulted to lost its magnetism in higher temperature than $150^{\circ}C$/10 minute. Conclusion: The measured ISQ values showed insignificant differences in case of no changes in the magnetism of the $Smartpeg^{TM}s$. It seems that the $Smartpeg^{TM}s$ can be used repeatedly in every measurement if the original magnetisms of the $Smartpeg^{TM}s$ can be recognized. There seems to be no significant changes in the measured ISQ values of 'attach-detach $Smartpeg^{TM}s'$ only if the screw pitches were unimpaired. The clinical sterilization methods seems acceptable because the result was resulted to lost its magnetism in higher temperature than $150^{\circ}C$/10minute.