• 제목/요약/키워드: Vacuum degree

검색결과 241건 처리시간 0.03초

위성에 탑재된 상변화물질 열제어장치 비행모델의 열진공시험 및 이를 통한 열해석 모델 보정 (Thermal Vacuum Test of the Phase Change Material Thermal Control Unit Loaded on the Satellite Flight Model and Thermal Model Correlation with Test Results)

  • 조연;김택영;서정기;장태성;박홍영
    • 한국항공우주학회지
    • /
    • 제50권10호
    • /
    • pp.729-737
    • /
    • 2022
  • 하반기에 발사 예정인 차세대소형위성2호(NEXTSat-2)에 탑재된 고상-액상 상변화물질 열제어장치(Phase Change Material Thermal Control Unit, PCMTCU)의 비행모델에 대한 위성 차원 열진공시험 결과로부터 융해-응고에 따른 작동과정을 분석하였다. 시험결과 PCM의 상변화는 발열부품의 온도 안정화에 기여함을 확인하였다. 시험에서 계측된 온도변화를 이용하여 타당한 정도의 정확도를 갖도록 PCMTCU의 열해석모델에 대한 보정을 수행하였다. 보정된 열해석모델로써 임무궤도의 정상 작동에 따른 PCMTCU의 주기적 온도변화를 예측하였으며, PCM의 액상분율로써 정량적 기여도를 평가하였다. 향후 임무궤도에서의 비행자료를 수신하여 PCMTCU의 우주 환경 검증을 완료할 예정이다.

각종 근관충전용 시멘트의 미세누출에 관한 연구 (A STUDY ON THE MICROLEAKAGE OF ROOT CANAL SEALERS)

  • 조지선;황호길;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.202-217
    • /
    • 1996
  • The purpose of this study was to compare the degree of microleakage of Glass-Ionomer root canal sealer possessed several enviable properties with that of the other sealers and to evaluate clinical performance. One hundred twenty single-rooted teeth were used in this experiment. The teeth were cleaned mechanically and immersed for 24 hours in 5.25% sodium hypochlorite and clinical crowns then were removed. After the root canals were instrumented using a step-back technique. one hundred twenty single-rooted teeth were divided into five groups of 24 in each. Group 1 : Tubli-Seal(Kerr Co., MI, U.S.A/ZOE-based), lateral condensation Group 2 : Sealapex(Kerr/Sybron, Romulus, MI/ $Ca(OH)_2$-based), lateral condensation Group 3 : AH 26(De Trey Co., Zurich Switzerland/Resin-based), lateral condensation Group 4 : Ketac-Endo(ESPE GMBH & CO. KG Seefeld:oberbay. Germany/ Glass Ionomer Cement-based), lateral condensation Control group : no sealer. lateral condensation And then. the root canals were obturated by lateral condensation technique with gutta-percha and experimental sealers. The control group were obturated without sealer. The teeth were placed in a vacuum chamber for 15 minutes and immersed 2% methylene blue under vacuum for 15 minutes. The teeth were passively stained for 1 week and 2 weeks and were cleared and evaluated for linear dye leakage using Tool maker's microscope(${\times}200$). The results were as follows: 1. There were statistically significant differences in the degree of dye penetration between the control group and experimental groups(p<0.05). 2. In the experimental groups, Sealapex($1.2871{\pm}0.9180mm$) exhibited the lowest mean value of dye penetration, followed by Ketac-Endo($1.4432{\pm}0.8082mm$), AH 26($1.5030{\pm}0.7752mm$) and Tubli-Seal($1.6458{\pm}1.0292mm$)(p>0.05). 3. There were statistically significant differences in the variation of microleakage between 1 week and 2weeks in Tubli-Seal and Seal apex groups (p<0.05). 4. The degree of dye penetration of all groups were increased as the time elapsed and AH 26 showed the lowest variation(+0.11) and Tubli-Seal(+ 1.03) showed the highest variation (p<0.001).

  • PDF

Process Fault Probability Generation via ARIMA Time Series Modeling of Etch Tool Data

  • Arshad, Muhammad Zeeshan;Nawaz, Javeria;Park, Jin-Su;Shin, Sung-Won;Hong, Sang-Jeen
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.241-241
    • /
    • 2012
  • Semiconductor industry has been taking the advantage of improvements in process technology in order to maintain reduced device geometries and stringent performance specifications. This results in semiconductor manufacturing processes became hundreds in sequence, it is continuously expected to be increased. This may in turn reduce the yield. With a large amount of investment at stake, this motivates tighter process control and fault diagnosis. The continuous improvement in semiconductor industry demands advancements in process control and monitoring to the same degree. Any fault in the process must be detected and classified with a high degree of precision, and it is desired to be diagnosed if possible. The detected abnormality in the system is then classified to locate the source of the variation. The performance of a fault detection system is directly reflected in the yield. Therefore a highly capable fault detection system is always desirable. In this research, time series modeling of the data from an etch equipment has been investigated for the ultimate purpose of fault diagnosis. The tool data consisted of number of different parameters each being recorded at fixed time points. As the data had been collected for a number of runs, it was not synchronized due to variable delays and offsets in data acquisition system and networks. The data was then synchronized using a variant of Dynamic Time Warping (DTW) algorithm. The AutoRegressive Integrated Moving Average (ARIMA) model was then applied on the synchronized data. The ARIMA model combines both the Autoregressive model and the Moving Average model to relate the present value of the time series to its past values. As the new values of parameters are received from the equipment, the model uses them and the previous ones to provide predictions of one step ahead for each parameter. The statistical comparison of these predictions with the actual values, gives us the each parameter's probability of fault, at each time point and (once a run gets finished) for each run. This work will be extended by applying a suitable probability generating function and combining the probabilities of different parameters using Dempster-Shafer Theory (DST). DST provides a way to combine evidence that is available from different sources and gives a joint degree of belief in a hypothesis. This will give us a combined belief of fault in the process with a high precision.

  • PDF

간호사의 생동성에 영향을 미치는 요인 (Factors Influencing Vitality among Nurses)

  • 이지순;오원옥
    • 대한간호학회지
    • /
    • 제37권5호
    • /
    • pp.676-683
    • /
    • 2007
  • Purpose: This study was conducted to understand the degree of vitality, meaning in life and self-efficacy and to elucidate the factors influencing this vitality in the nurses of Korea. Method: A cross-sectional survey of nurses from 4 hospitals was conducted by convenience sampling. Data collection was conducted through the use of questionnaires which were constructed to include a Vitality Self Test, Purpose in Life Test and Self-efficacy Scale. Results: The degree of vitality in nurses was in the middle range. The nurses of this study had few goals towards meaning in life, and an existential vacuum state. A positive relationship was found between vitality and the research variables. The significant predictors influencing vitality in nurses were meaning in life, self-efficacy, and clinical career, and these variables accounted for 28.7% of the variance in vitality. Conclusions: This results support that vitality is an important link with meaning in life and self-efficacy. There should be a comprehensive study in the future for in-depth understanding of the vitality of nurses.

자장여과 아크 소스에서 각 전자석이 플라즈마 인출에 미치는 영향 (The effects of solenoid magnet on plasma extraction in Filtered Vacuum Arc Source (FVAS))

  • 김종국;변응선;이구현;조영상
    • 한국진공학회지
    • /
    • 제10권4호
    • /
    • pp.431-439
    • /
    • 2001
  • 비정질 다이아몬드 박막(amorphous-Diamond a-B)을 증착하기 위하여 제작된 Filtered Vacuum Arc Source (FVAS)는 60도의 굽힘 각도를 가지는 토러스형 구조로 토러스 반경 266 mm, 플라즈마 덕트 반경 80 % 전체 길이 600 mm이며, 1 개의 영구자석 및 5 개의 전자석으로 되어있다. 플라즈마 덕트는 임의의 전압을 인가할 수 있도록 전기적으로 절연 시켰으며, 덕트 내부는 배플을 설치하여 macro-particle의 되튐 현상을 방지하였다. 사용된 음극은 직경 80 mm의 graphite이다. 각 전자석이 플라즈마 인출에 미치는 영향은 taguchi 실험계획법을 이용, 수치 모사와 실험을 행하였다. 소스 전자석과 인출 전자석은 아크의 안정성에 영향을 주었고, 빔 인출 전류는 낮은 소스 전자석 전류와 특정한 필터 전자석 전류에서 최대값을 나타내었다. 이때 소스, 인출, 굽힘, 반사, 출구 전자석의 전류값은 1 A, 3 A, 5 A, 5 A, 5 A였으며, 아크 전류 30 A일 때, 빔 전류 밀도 3.2 mA/$\textrm{cm}^2$, 평균 증착률 5 $\AA$/sec를 얻었다. 또한 플라즈마 덕트의 바이어스 전압 증가에 따라, 빔 전류 밀도는 증가하였으며, 더 효율적인 빔을 인출할 수 있었다.

  • PDF

전처리조건에 따른 냉풍감압건조 복숭아의 이화학적 및 항산화 활성 (Effect of Different Pre-treatments on the Physicochemical and Antioxidant Activities of Cold-Vacuum Dried Peaches)

  • 권기만;김재원;윤광섭
    • 한국식품과학회지
    • /
    • 제45권4호
    • /
    • pp.466-472
    • /
    • 2013
  • 전처리 방법에 따른 냉풍감압건조 복숭아의 이화학적 및 기능적 특성을 조사한 결과 수분함량은 0.3% NaCl 처리에서 유의적인 낮은 수분함량을 나타내었다. pH의 경우 전처리 구에서 낮아지는 경향을 보였고, 당도 및 당산비는 0.1% Vit-C 처리에서 높은 값을 나타내었다. 색도는 전반적으로 건조가 진행될수록 밝기를 나타내는 L 값은 감소하는 경향을 보였으며 색차는 Vit-C>NaCl>Sol-Ca>non-treated 순으로 낮은 값을 나타내었다. 갈변도 또한 색차의 결과와 일치하는 경향을 나타내었다. 총당은 무처리, NaCl, Vit-C 및 Sol-Ca 처리구가 무처리에 비해 높은 함량을 나타내어 향기 및 감미 유지 효과가 있는 것으로 관찰되었고, 유리당은 Vit-C 및 Sol-Ca 처리구에서 fructose, glucose 및 sucrose의 함량이 높은 것으로 나타났다. 절단력은 무처리에 비해 전처리구에서 증가하는 결과를 나타내었으며, Sol-Ca 처리구에서 가장 높은 값을 나타내었다. 관능특성에서는 전처리 구가 무처리에 비하여 외관, 색, 맛, 종합적 기호도가 높아지는 결과를 나타내었으며 특히, Vit-C 처리에서 가장 높은 기호특성을 나타내었다. 전처리방법에 따른 폴리페놀, 플라보노이드 및 프로안토시아니딘 함량에서는 전반적으로 전처리 구에서 높은 함량을 나타내었으며 프로안토시아니딘 함량에서 Vit-C 처리에서 가장 높은 함량을 나타내었다. 항산화능에서는 유용성분 함량이 높을수록 라디칼 소거능이 높아지는 양적 상관관계를 나타내었다.

산업용 규모의 압체고주파진공건조시스템 성능 평가 (Performance of a Commercial Scale Radio-frequency/vacuum Dryer Combined with a Mechanical Compressive Load)

  • 이남호;;황의도;장세환;신익현
    • Journal of the Korean Wood Science and Technology
    • /
    • 제37권3호
    • /
    • pp.192-199
    • /
    • 2009
  • 본 연구에서는 수용재적 약 $3m^3$ 크기의 압체고주파진공건조시스템을 이용하여 Azobe (Lophira alata)와 국산 소나무(Pinus densiflora) 제재목을 건조하면서 건조시스템의 성능을 평가하였다. 압체고주파진공건조기의 진공도는 80~105 mbar를 유지시켰고, 건조 중 재온은 건조초기 $40^{\circ}C$에서 시작하여 건조말기 $60^{\circ}C$까지 상승시켰다. 全건조기간에 걸쳐 기전전극판측의 재온은 제어온도보다 항상 높게 유지되는 반면, 접지전극판측의 재온은 항상 낮게 유지되었다. 건조시간이 경과함에 따라 접지전극판측의 재온은 제어온도보다 더욱 낮고 기전전극판측의 재온은 제어온도보다 더욱 높게 나타났다. Azobe의 경우 입력포트측의 평균최종함수율보다 입력포트반대측의 평균최종함수율이 모든 잔적층에서 미미하게 높게 나타났으며, 잔적층의 수직방향으로의 최종함수율은 기전전극판측에서 접지전극판측을 향할수록 높게 나타났다. 기전전극판과 인접한 잔적층의 경우 재목당 평균할렬의 발생길이가 매우 경미하였으나, 접지전극판측을 향할수록 증가하는 경향을 보였다. 또한 투입된 에너지의 효율면에 있어 선진국의 상용설비와 유사한 수준을 보여 주는 것으로 평가되었다.

Suppression of MgO hydration using Self-Assembled Monolayers

  • Lee, Kyung-Wha;Kim, Tae-Jun;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.533-535
    • /
    • 2004
  • We suggest the use of a self-assembled ultra thin organic film that can suppress the hydration of MgO protective layer in AC-PDP. We analyzed the degree of hydration of MgO layer in AC-PDP by XPS when exposed to air after vacuum deposition which proved the effectiveness of the hydration prevention. We also made PDP test panels to demonstrate the improvement in the luminance and luminous efficiency when the hydration of MgO surface is suppressed by the use of self-assembled ultra thin organic film.

  • PDF

전동/발전기 코어에 의한 초전도 플라이휠 에너지 저장장치의 회전손실 특성 평가 (Rotational loss assessment of flywheel energy storage system by Motor/Generator core)

  • 이정필;한영희;정세용;한상철;정년호;성태현
    • 전기학회논문지
    • /
    • 제56권10호
    • /
    • pp.1775-1781
    • /
    • 2007
  • In this paper, the rotational loss of the superconductor flywheel energy storage system (SFES) by motor/generator stator core was assessed. To do this, the vertical axial type SFES with journal type superconductor bearing was manufactured. To quantitatively assess the rotational loss by the stator core, the rotational losses by superconductor bearing and the degree of a vacuum were measured. In case of variation of the inner radius and outer radius of the stator core, the rotational losses were measured. From the experimental results, It is confirmed that the rotational loss can be reduced by means of the optimal stator core design.

Center-body 디퓨져 형상설계를 위한 수치적연구 (Numerical Study for Design of Center-body Diffuser)

  • 김종록
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.487-491
    • /
    • 2009
  • center-body디퓨져에 대한 형상 설계 요소를 분석하고 수치적 기법을 통한 설계형상 변수를 구성하였다. 수치기법으로는 Center-body 디퓨져의 내부유동해석을 위하여 2차원 축대칭 Navier-Stokes equation와 $k-{\omega}$난류모델을 사용하였다. 또한 center-body디퓨져의 시동압력과 진공도 및 형상설계변수에 대해서 2차목 디퓨져와 비교하였다.

  • PDF