• Title/Summary/Keyword: Vacuum degree

Search Result 241, Processing Time 0.028 seconds

Thermal Vacuum Test of the Phase Change Material Thermal Control Unit Loaded on the Satellite Flight Model and Thermal Model Correlation with Test Results (위성에 탑재된 상변화물질 열제어장치 비행모델의 열진공시험 및 이를 통한 열해석 모델 보정)

  • Cho, Yeon;Kim, Taig Young;Seo, Joung-Ki;Jang, Tae Seong;Park, Hong-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.10
    • /
    • pp.729-737
    • /
    • 2022
  • Melting and icing process of the PCMTCU(Phase Change Material Thermal Control Unit) installed on the NEXTSat-2, which is scheduled to be launched in the second half, was investigated through the results of satellite-level TVT(Thermal Vacuum Test). As a result of the test, it was confirmed that the latent heat of PCM contributes to the temperature stabilization of the heating components. The thermal model for numerical analysis of the PCMTCU was correlated to acquire a reasonable degree of accuracy using the collected temperature measurements during TVT. The periodic temperature variation of the PCMTCU in normal on-orbit operation was predicted with the correlated thermal model, and the quantitative contribution of the PCM on the thermal energy management was evaluated with the liquid fraction. It will receive flight telemetry from the NEXTSat-2 after the launch, and complete the space verification of the PCMTCU.

A STUDY ON THE MICROLEAKAGE OF ROOT CANAL SEALERS (각종 근관충전용 시멘트의 미세누출에 관한 연구)

  • Cho, Ji-Sun;Hwang, Ho-Keel;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.202-217
    • /
    • 1996
  • The purpose of this study was to compare the degree of microleakage of Glass-Ionomer root canal sealer possessed several enviable properties with that of the other sealers and to evaluate clinical performance. One hundred twenty single-rooted teeth were used in this experiment. The teeth were cleaned mechanically and immersed for 24 hours in 5.25% sodium hypochlorite and clinical crowns then were removed. After the root canals were instrumented using a step-back technique. one hundred twenty single-rooted teeth were divided into five groups of 24 in each. Group 1 : Tubli-Seal(Kerr Co., MI, U.S.A/ZOE-based), lateral condensation Group 2 : Sealapex(Kerr/Sybron, Romulus, MI/ $Ca(OH)_2$-based), lateral condensation Group 3 : AH 26(De Trey Co., Zurich Switzerland/Resin-based), lateral condensation Group 4 : Ketac-Endo(ESPE GMBH & CO. KG Seefeld:oberbay. Germany/ Glass Ionomer Cement-based), lateral condensation Control group : no sealer. lateral condensation And then. the root canals were obturated by lateral condensation technique with gutta-percha and experimental sealers. The control group were obturated without sealer. The teeth were placed in a vacuum chamber for 15 minutes and immersed 2% methylene blue under vacuum for 15 minutes. The teeth were passively stained for 1 week and 2 weeks and were cleared and evaluated for linear dye leakage using Tool maker's microscope(${\times}200$). The results were as follows: 1. There were statistically significant differences in the degree of dye penetration between the control group and experimental groups(p<0.05). 2. In the experimental groups, Sealapex($1.2871{\pm}0.9180mm$) exhibited the lowest mean value of dye penetration, followed by Ketac-Endo($1.4432{\pm}0.8082mm$), AH 26($1.5030{\pm}0.7752mm$) and Tubli-Seal($1.6458{\pm}1.0292mm$)(p>0.05). 3. There were statistically significant differences in the variation of microleakage between 1 week and 2weeks in Tubli-Seal and Seal apex groups (p<0.05). 4. The degree of dye penetration of all groups were increased as the time elapsed and AH 26 showed the lowest variation(+0.11) and Tubli-Seal(+ 1.03) showed the highest variation (p<0.001).

  • PDF

Process Fault Probability Generation via ARIMA Time Series Modeling of Etch Tool Data

  • Arshad, Muhammad Zeeshan;Nawaz, Javeria;Park, Jin-Su;Shin, Sung-Won;Hong, Sang-Jeen
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.241-241
    • /
    • 2012
  • Semiconductor industry has been taking the advantage of improvements in process technology in order to maintain reduced device geometries and stringent performance specifications. This results in semiconductor manufacturing processes became hundreds in sequence, it is continuously expected to be increased. This may in turn reduce the yield. With a large amount of investment at stake, this motivates tighter process control and fault diagnosis. The continuous improvement in semiconductor industry demands advancements in process control and monitoring to the same degree. Any fault in the process must be detected and classified with a high degree of precision, and it is desired to be diagnosed if possible. The detected abnormality in the system is then classified to locate the source of the variation. The performance of a fault detection system is directly reflected in the yield. Therefore a highly capable fault detection system is always desirable. In this research, time series modeling of the data from an etch equipment has been investigated for the ultimate purpose of fault diagnosis. The tool data consisted of number of different parameters each being recorded at fixed time points. As the data had been collected for a number of runs, it was not synchronized due to variable delays and offsets in data acquisition system and networks. The data was then synchronized using a variant of Dynamic Time Warping (DTW) algorithm. The AutoRegressive Integrated Moving Average (ARIMA) model was then applied on the synchronized data. The ARIMA model combines both the Autoregressive model and the Moving Average model to relate the present value of the time series to its past values. As the new values of parameters are received from the equipment, the model uses them and the previous ones to provide predictions of one step ahead for each parameter. The statistical comparison of these predictions with the actual values, gives us the each parameter's probability of fault, at each time point and (once a run gets finished) for each run. This work will be extended by applying a suitable probability generating function and combining the probabilities of different parameters using Dempster-Shafer Theory (DST). DST provides a way to combine evidence that is available from different sources and gives a joint degree of belief in a hypothesis. This will give us a combined belief of fault in the process with a high precision.

  • PDF

Factors Influencing Vitality among Nurses (간호사의 생동성에 영향을 미치는 요인)

  • Lee, Ji-Soon;Oh, Won-Oak
    • Journal of Korean Academy of Nursing
    • /
    • v.37 no.5
    • /
    • pp.676-683
    • /
    • 2007
  • Purpose: This study was conducted to understand the degree of vitality, meaning in life and self-efficacy and to elucidate the factors influencing this vitality in the nurses of Korea. Method: A cross-sectional survey of nurses from 4 hospitals was conducted by convenience sampling. Data collection was conducted through the use of questionnaires which were constructed to include a Vitality Self Test, Purpose in Life Test and Self-efficacy Scale. Results: The degree of vitality in nurses was in the middle range. The nurses of this study had few goals towards meaning in life, and an existential vacuum state. A positive relationship was found between vitality and the research variables. The significant predictors influencing vitality in nurses were meaning in life, self-efficacy, and clinical career, and these variables accounted for 28.7% of the variance in vitality. Conclusions: This results support that vitality is an important link with meaning in life and self-efficacy. There should be a comprehensive study in the future for in-depth understanding of the vitality of nurses.

The effects of solenoid magnet on plasma extraction in Filtered Vacuum Arc Source (FVAS) (자장여과 아크 소스에서 각 전자석이 플라즈마 인출에 미치는 영향)

  • 김종국;변응선;이구현;조영상
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.4
    • /
    • pp.431-439
    • /
    • 2001
  • In this paper, the a-Diamond films were synthesized using filtered vacuum arc source (FVAS), FVAS was composed of a torus structure with bending angle of 60 degree. The radius of torus was 266 mm, the radius of plasma duct was 80 mm and the total length was 600 mm. The magnet parts were composed of one permanent magnet and five solenoid magnets. The plasma duct was electrically isolated from the ground so that a bias voltage could be applied. The baffles inside plasma duct were installed in order to prevent the recoil effect of macro-particles. Cathode was made of graphite with 80 mm in diameter. The effects of solenoid magnet on plasma extraction were investigated by computer simulation and experiment using Taguchi's methode. The source and extraction magnet affected the arc stabilization. The extraction beam current was maximized with low value of the source magnet current and high value of the filtering magnet current. The beam current density was 3.2 mA/$\textrm{cm}^2$ and average deposition rate was 5 $\AA$/sec when the currents of arc discharge, source, extraction, bending, deflection and outlet magnet were 30 A, 1 A, 3 A, 5 A, 5 A, and 5 A, respectively. The beam current density and the efficiency of beam transportation were increased with the positive bias voltage of the plasma duct.

  • PDF

Effect of Different Pre-treatments on the Physicochemical and Antioxidant Activities of Cold-Vacuum Dried Peaches (전처리조건에 따른 냉풍감압건조 복숭아의 이화학적 및 항산화 활성)

  • Kwon, Gi-Man;Kim, Jae-Won;Youn, KwangSup
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.4
    • /
    • pp.466-472
    • /
    • 2013
  • This study was performed to determine the effects of the pretreatment and cold-vacuum drying methods on the physicochemical properties and antioxidant activities of dried peaches. Moisture content was significantly lower with 0.3% NaCl treatment with cold-vacuum drying. The pH, brix and acid ratio (SS/TA) were the lowest with 1.0% soluble Ca treatment, while soluble solid and SS/TA were significantly higher with 0.1% vitamin C treatment compared to those with other treatments. The ${\delta}E$ and browning degree was lower in the pretreated sample compared to the untreated sample. Cutting strength of dried peaches was highest in the pretreated samples, and it was the highest with 1.0% soluble Ca treatment. Total sugar content with 0.1% vitamin C and 1.0% soluble Ca treatment was significantly higher than that with 0.3% NaCl treatment. The free sugar content was lower with 0.3% NaCl treatment but it was higher with 0.1% vitamin C and 1.0% soluble Ca treatment. The sensory evaluation result was highest with 0.1% vitamin C treatment. Phenolic compounds and antioxidant ability were the highest with the 0.1% vitamin C and 0.1% soluble Ca treatment; all the dried peaches showed relatively high antioxidant activities. These results suggest that pretreatment can affect the quality of dried peaches, showing that cold-vacuum drying can be applied for the production of high quality dried peach products.

Performance of a Commercial Scale Radio-frequency/vacuum Dryer Combined with a Mechanical Compressive Load (산업용 규모의 압체고주파진공건조시스템 성능 평가)

  • LEE, Nam-Ho;ZHAO, Xue-Feng;HWANG, Ui-Do;CHANG, Sae-Hwan;SHIN, Ik-Hyun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.192-199
    • /
    • 2009
  • This study was carried out to investigate the performance of a radio-frequency/vacuum dryer combined with a mechanical compressive load (RF/VC) with a scale of about $3m^3$ during drying board of Azobe (Lophira alata) and Korean red pine (Pinus densiflora). The degree of vacuum of the RF/VC system was maintained at 80~105 torr, and wood temperature was increased from $40^{\circ}C$ at the beginning of drying to $60^{\circ}C$ at the end of drying and the radiofrequency generator was operated with schedule of 7 minute-ON and 3 minute-OFF. The wood temperatures near charge plate always remained higher than those of the control during all of the drying stage, whereas the wood temperature near ground plate always remained lower than those of the controlled. As drying time proceeding, the temperature of the wood near ground plate presented lower than those of the control. Whereas the temperature of the wood near charge plate presented higher than those of the controlled. The final average moisture contents of the Azobe boards stacked near the input side of the RF generator showed slightly lower than those near the opposite side. Those of the wood stacked in the layers near the charge plate were lower than those of near the ground plate. The average length of surface checks of the Azobe boards stacked near the charge plate was very slight, whereas that toward the ground plate represented high values. The efficiency of input energy was simliar with the commercial systems.

Suppression of MgO hydration using Self-Assembled Monolayers

  • Lee, Kyung-Wha;Kim, Tae-Jun;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.533-535
    • /
    • 2004
  • We suggest the use of a self-assembled ultra thin organic film that can suppress the hydration of MgO protective layer in AC-PDP. We analyzed the degree of hydration of MgO layer in AC-PDP by XPS when exposed to air after vacuum deposition which proved the effectiveness of the hydration prevention. We also made PDP test panels to demonstrate the improvement in the luminance and luminous efficiency when the hydration of MgO surface is suppressed by the use of self-assembled ultra thin organic film.

  • PDF

Rotational loss assessment of flywheel energy storage system by Motor/Generator core (전동/발전기 코어에 의한 초전도 플라이휠 에너지 저장장치의 회전손실 특성 평가)

  • Lee, Jeong-Phil;Han, Young-Hee;Jung, Se-Yong;Han, Sang-Chul;Jeong, Nyeon-Ho;Sung, Tae-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.10
    • /
    • pp.1775-1781
    • /
    • 2007
  • In this paper, the rotational loss of the superconductor flywheel energy storage system (SFES) by motor/generator stator core was assessed. To do this, the vertical axial type SFES with journal type superconductor bearing was manufactured. To quantitatively assess the rotational loss by the stator core, the rotational losses by superconductor bearing and the degree of a vacuum were measured. In case of variation of the inner radius and outer radius of the stator core, the rotational losses were measured. From the experimental results, It is confirmed that the rotational loss can be reduced by means of the optimal stator core design.

Numerical Study for Design of Center-body Diffuser (Center-body 디퓨져 형상설계를 위한 수치적연구)

  • Kim, Jong-Rok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.487-491
    • /
    • 2009
  • A study is analyzed on the design factor of Center-body diffuser and performed on conceptual design of Center-body diffuser with Computational Fluid Dynamic. The flow field of Center-body diffuser is calculated using Axisymmetric two-dimensional Navier-Stokes equation with $k-{\omega}$ turbulence model. The center-body diffuser is compared with second throat exhaust diffuser in terms of starting pressure, the degree of vacuum pressure, the design factor.

  • PDF