• 제목/요약/키워드: Vacuum Plate

검색결과 268건 처리시간 0.04초

항공기 박판 구조의 가공가능 폭과 두께에 관한 실험 연구 (An Experiment of Machineable Width and Thickness of Airframe Thin Plate Structure)

  • 신용보;김수진
    • 한국생산제조학회지
    • /
    • 제22권1호
    • /
    • pp.162-167
    • /
    • 2013
  • The most important factor in an aircraft manufacturing is stability and weight reduction. Most of aircraft components are designed with thin plate type to satisfy weight reduction needs. The thin plate is difficult to be machined because it is apt to be vibrated by dynamic force generated in milling process. The most critical factor in machining of aluminum thin plate is width and thickness between stiffeners. So we tested many cases to find out the machinable minimum thickness at different width between stiffeners. And with the data obtained from many tests, this papers suggested the standard width thickness relation that is machinable without vacuum fixture. Machinist will be able to reduce the cost of aircraft thin plate parts by reducing the number of vacuum fixture used by the help of this standard.

지역난방 적용 태양열시스템의 장기 열성능 분석 (Analysis of Long-term Thermal Performance of Solar Thermal System Connected to District Heating System)

  • 백남춘;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.167-173
    • /
    • 2007
  • This study analyzed by simulation using TRNSYS as well as by experiment on the solar district heating system installed for the first time for the district heating system in Bundang. Simulation analysis using TRNSYS focused on the thermal behavior and long-term thermal efficiency of solar system. Experiment carried out for the reliability of simulation system. This solar system where the circuits of two different collectors, flat plate and vacuum tube collector, are connected in series by a collector heat exchanger, and the collection characteristics of each circuit varies. Therefore, these differences must be considered for the system's control. This system uses variable flow rate control in order to obtain always setting temperature of hot water by solar system. Specifically, this is a system that heats returning district heating water (DHW) at approximately $60^{\circ}C$ using a solar collector without a storage tank, up to the setting temperature of approximately $85{\sim}95^{\circ}C$ To realize this, a flat plate collector and a vacuum tube collector are used as separate collector loops. The first heating is performed by a flat plate collector loop and the second by a vacuum tube collector loop. In a gross collector area basis, the mean system efficiency, for 4 years, of a flat plate collector is 33.4% and a vacuum tube collector is 41.2%. The yearly total collection energy is 2,342GJ and really collection energy per unit area ($m^2$) is 1.92GJ and 2.37GJ respectively for the flat plate vacuum tube collector. This result is very important on the share of each collector area in this type of solar district heating system.

고진공하에서의 위성체 부품의 오염측정에 관한 연구 (A Study on the contamination measurement of spacecraft components under High Vacuum Environment)

  • 이상훈;서희준;문귀원;최석원
    • 한국진공학회지
    • /
    • 제11권2호
    • /
    • pp.87-96
    • /
    • 2002
  • 위성체가 작동하는 우주환경인 고진공상태에서는 위성체의 부품에서 발생 할 수 있는 outgassing으로 인해 위성체가 오염되어 위성체의 성능이 저하될 수 있으며, 특히 이차면경(second surface mirror) 및 광학렌즈 등을 오염시킴으로써 위성체 본연의 임무수행 실패라는 결과를 초래할 수도 있다. 따라서 지상에서 위성체의 부품에 대해 고온($85^{\circ}C$ 이상)과 고진공($5.0\times10^{-3}$ Pa 이하)의 상태를 모사하여 오염물질을 제거함으로써 outgassing의 발생을 막고, 아울러 오염근원을 검출할 수 있는 vacuum bake-out 시험이 필수적이라 할 수 있다. 이를 위해서 한국항공우주연구원 우주시험동에 설치된 bake-out 챔버를 이용하여 위성체 부품 중에서 SAR(Solar Array Regulator)와 MLI(Multi Layer Insulator)를 예를 들어 오염측정에 관한 연구를 수행하였다. 항공우주연구원의 bake-out 챔버는 rotary vacuum pump와 booster pump를 이용하여 5.0 Pa의 저진공을 형성하고, 2대의 cryopump를 이용하여$5.0\times10^{-3}$ Pa 이하의 고진공을 생성하게 된다. 또한 $180^{\circ}C$까지의 고온을 모사하기 위하여 챔버 shroud 안쪽에 ceramic 재질로 된 heater가 $30^{\circ}$간격으로 총 48개를 설치되어 있으며, 온도제어는 PID(Proportional Integral Differential) 제어 방식이 이용되었다. Vacuum bake-out 시험시에는 RGA(Residual Gas Analyzer)를 이용하여 각종 오염물질을 검출할 수 있고, TQCM(Thermoelectric Quartz Crystal Microbalance)을 사용하여 발생하는 오염물질의 방출률(outgassing rate)을 측정한다. 또한 필요시에는 IR/UV Spectrometer를 이용하여 witness plate에 흡착된 오염물질의 성분을 분석하여 위성체 부품으로의 적합성을 판단한다. SAR의 bake-out에서는 TQCM 측정결과 오염물질이 시간에 따라 감소추이는 보이지만 꾸준히 배출되고 있는 경향을 나타내고, RGA 분석결과 그 성분이 고분자 화합물로 추정되어 위성체 부품으로 사용하기에는 적절하지 못할 것으로 판단하였다. MLI의 bake-out에서는 RGA 및 witness plate를 이용한 오염측정 결과 특이한 오염물질을 발견할 수 없었다.

비유리식(nonglass) 진공관의 진공도가 집열판의 열적 특성에 미치는 영향 (Effect of Vacuum in a Non-glass Vacuum Tube on the thermal behavior of the Absorber Plate)

  • 오승진;현준호;김남진;이윤준;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제28권3호
    • /
    • pp.67-73
    • /
    • 2008
  • This study has been carried out to investigate the effect of vacuum on the thermal performance of a nonglass evacuated tube. A series of measurements are made indoors to monitor the temperature change of the absorber plate contained in the evacuated tube under different conditions of vacuum and heat fluxes. Those temperatures measured at the thermal equilibrium could be used to assess the heat losses to the ambient in link with the steady operation of non-glass evacuated tubes for solar exploitation.

The New Storage Technology: Effect of Far Infrared Ray (FIR) Ceramic Sheet Package on Storage Quality of Pork Loin

  • Lin, Liang-Chuan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제16권11호
    • /
    • pp.1695-1700
    • /
    • 2003
  • A total of 30 pork loin sections were utilized to evaluate the effects of FIR ceramic sheet in PE and vacuum package on preserving the quality of chilled pork stored at 4 and $0^{\circ}C$. Based on meat color, results indicated that pork loin packaged in ceramic sheet and control treatment showed that the samples of the control treatment tended to darken gradually in comparison with the samples at 0 day, but FIR treatment had few changes. Among the total plate counts of sliced loin in PE and loin in vacuum package under different storage times at 4 and $0^{\circ}C$, results showed that FIR ceramic sheet package treatment had lower total plate counts and significant differences (p<0.05). In VBN value, both treatments tended to rise high with the increasing of storage time, but the FIR treatment was significantly lower (p<0.05) than the control treatment. Its results had a corresponding relationship with the total plate counts. Regarding the drip loss of sliced loin in PE and loin in vacuum package, it showed that FIR ceramic sheet package treatment had lower drip loss and significant differences (p<0.01). These results showed that the use of FIR ceramic sheet package, including PE and vacuum package, is an effective method of maintaining the quality of meat.

금형 충전 해석을 이용한 연료전지 분리판 진공 다이캐스팅 금형 설계 방안 및 실험 검증 (Vacuum Die Casting Mold Design of Fuel Cell Bipolar Plate using Die Filling Simulation and Experimental Verification)

  • 진철규;장창현;강충길
    • 한국주조공학회지
    • /
    • 제32권2호
    • /
    • pp.65-74
    • /
    • 2012
  • In this paper, we present the results of our studies on optimal die design towards development of a vacuum die casting process to fabricate fuel cell bipolar plate with micro-channel array. Cavity and overflow shape is designed by computational filling analysis of MAGMA soft. Optimal die design consists of seven overflows at the end of cavity and three overflows at each side wall of cavity. The molten metal that passed the gate and reached the side wall flowed into the side overflow, no turbulent flow occurred, and the filling behavior and velocity distribution were uniform. In addition, partially solidified molten metal passing through the channel was perfectly eliminated by overflow without back-flow. When vacuum pressure, injection speed of low and high region was 300 mbar, 0.3 m/s and 2.5 m/s respectively with Silafont 36 die casting alloy, sound sample without casting defects was obtained. The experimental results are nearly consistent with simulation results.

표면처리를 이용한 단일진공관과 기존 이중진공관 태양열집열기의 성능비교 연구 (Study on Performance Comparison for Solar Collectors with Single Evacuated Tube using Surface Treatment and Commercial Double Evacuated Tube)

  • 전태규;양영준;이경희;안영철
    • 한국기계가공학회지
    • /
    • 제12권5호
    • /
    • pp.149-156
    • /
    • 2013
  • The performances of solar collectors with single and double evacuated tube were experimentally compared. The solar collector with single evacuated tube using surface treatment in this study consists of radiation fin, heat pipe, absorber plate, glass tube, cap and regulating valve, and so on. Surface treatment was conducted for heat pipe and absorber plate with black chrome plating and copper black coating. As the results, the performance of solar collector with single evacuated tube using surface treatment showed good results compared that of double evacuated tube. Absorber plate played a positive role in performance and showed increase of about 28%. Further performance depends on vacuum degree and vacuum degree has to be considered economical efficiency in solar collector.

Effect of the suction plate shape on metering performance of a vacuum metering device for garlic seeds

  • Kim, Deok-Keun;Choi, Yeong-Soo;Yang, Seung-Hwan
    • 농업과학연구
    • /
    • 제47권4호
    • /
    • pp.829-844
    • /
    • 2020
  • A vacuum metering device for garlic seeds was developed, and its metering performance was tested according to the design factors. Three design factors were as follows: suction surface diameter (Edge), suction surface curvature (Type), and guide height (Guide). The suction surface curvature represents the distance between the center of the grooved suction plate and the bottom of suction plate. The metering rate and multiple metering rate were analyzed as the metering performance of the developed device with two varieties of garlic seeds: Namhae (warm region-adapted garlic) and Uiseong (cold region-adapted garlic). The best metering performance for the Namhae seeds were found with the following conditions: An Edge, Guide and Type of 40, 4, and 35 mm, respectively. In the case of the Uiseong seeds, the best conditions were as follows: An Edge, Guide and Type of 35, 4, and 30 mm, respectively. The guide height was found to be the most influential design factor on the metering performance of the metering rate and multiple rate for both Namhae seeds and Uiseong seeds. Additionally, the interaction between the area of the suction surface and the curvature of the suction surface had some effects on the multiple rate for the Uiseong seeds. It was concluded that the guide height should be 4 mm or higher so that more than 90% of the metering rate could be achieved for the tested garlic seeds with the developed metering device.