• 제목/요약/키워드: Vacuum Gauge

검색결과 75건 처리시간 0.019초

초음파유도 난포채란기의 개발과 이의 검증 (Development of needle guidance system and its evaluation for ultrasound-guided follicular aspiration)

  • 최민철;이효종;조성근;강태영;원현희
    • 대한수의학회지
    • /
    • 제39권6호
    • /
    • pp.1210-1217
    • /
    • 1999
  • This study was carried out to develop a newly designed ovum pick-up(OPU) instrument for ultrasound-guided transvaginal follicular aspiration in cows. This new instrument consists of out- & inner-layer stainless pipes and a grip with a trigger(hand) switch. Some gauge types of disposable needles and tubes can be attached to this inner pipe. With this instrument, while grasping an ovary with one hand, the other hand can handle in apiration and vacuum on/off with the least assitant's help. With this instrument the mean recovery rate of bovine follicular oocytes was 45.2%. In recovered oocytes, usable oocytes(Grade I & II) were 30.4% and this rate meant 1.4 oocytes per ovary. For 30 days after initial aspiration with this instrument, some adverse effects such as adhesion, hemorrhage, hematoma and other mass formation in/with ovaries were also examined by rectal examination, ultrasonographic and endoscopic images. Adhesion was found in one ovary 1 week after aspiration, and hemorrhagic lesion was found 1-2 days and petechia were found 3-5 days after aspiration and there was no remarkable adverse effects. It was found that this instrument could be applicable and safe for ovum pick-up in cows.

  • PDF

Nanotribology를 이용한 PMMA 박막의 Hardness와 Elastic Modulus 특성 연구 (Characteristics of Hardness and Elastic Modulus of PMMA Film using Nano-Tribology)

  • 김수인;김현우;노성철;윤덕진;장홍준;이종림;이창우
    • 한국진공학회지
    • /
    • 제18권5호
    • /
    • pp.372-376
    • /
    • 2009
  • 현대 반도체 공정에서 일정한 패턴을 생성하기 위하여 리소그래피(Lithography) 공정을 이용하고 있으나 선폭의 감소로 인하여 기존 UV를 이용한 PR(Photoresist) 이외에 e-beam을 이용한 PMMA(Polymethyl methacrylate) 리소그래피에 대한 관심이 높아지고 있다. 또한 리소그래피에 의하여 생성된 패턴은 이후 세정 공정에서 잔류물을 제거하는 과정에서 패턴 붕괴를 일으키게 되는데 이러한 패턴 붕괴에 대한 방어력은 패턴 형성 물질의 탄성력(Elastic modulus)과 비례하는 것으로 알려져 있다. 이 논문에서 우리는 PMMA의 soft-baking 이후 Hardness(H)와 Elastic modulus(Er)의 변화를 압입력을 25 uN에서 8,500 uN으로 134.52 uN 간격으로 증가시키며 측정하였다. 또한 이 실험에서 Hardness(H)와 Elastic modulus(Er)는 Hysitron사의 Triboindenter를 이용하여 측정하였고 압입팁은 Berkovich 팁을 사용하였다.

진공 측정 기술 개발 동향

  • 신용현
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.3-3
    • /
    • 2010
  • 이번 성원에드워드 학술상 수상자 선정은, 진공기술의 중요성에 공감하고 진공기술 발전을 위한 노력을 독려하자는 진공학회 회원들의 의견을 모아주신 결과로 생각한다. 본 발표에서는 그동안 한국표준과학연구원에서 수행해 온 진공 기술 연구 및 산학연 협력 네트워크 활동을 소개하고자 한다. 진공기술은 진공 환경을 발생시키고 측정 제어하며, 만들어진 진공 환경 안에서 원하는 작업을 할 수 있도록 하는 기술을 말한다. 우리나라의 주력산업인 반도체 및 디스플레이의 경우 그 생산 설비의 1/3이상이 진공 장비이며 진공 공정을 통해 만들어진다. 때문에 우리나라에서는 주력 산업분야나 그 전후방 산업의 경쟁력 강화 측면에서 진공기술 개발 중요성이 아주 크다. 한국표준과학연구원은 국가 대표 측정 기관으로 국가 측정 표준을 확립하고 측정관련 과학기술을 연구개발하며 그 성과를 보급하여 경제발전과 과학기술발전, 그리고 삶의 질 향상에 기여하는 것을 임무로 하고 있다. 우리나라에서 진공 측정 표준에 대한 연구가 본격적으로 시작된 것은 1984년으로 불용 장비로 불하받은 펌프와 챔버, 그리고 차관으로 도입된 Capacitance Diaphragm Gauge 몇 개만으로 시작되었다. 지금은 발전을 거듭하여 초음파 간섭 수은주 압력계를 비롯하여 정적 팽창시스템, 동적 팽창 시스템 등 진공도 범위별 국가 표준기와 리크 표준기를 자체 개발 하여 국가 측정 표준을 확립하고 있다. 우리나라의 진공 표준 및 측정 능력은 국제기구인BIPM에서 실시하는 국가 측정능력 비교시험을 통해 세계 최고 수준으로 인정 받은 바 있으며 교정검사 등을 통해 산학연에 보급되고 있다. 진공 측정 및 표준기술을 토대로, 1999년부터 과학기술부와 산업자원부의 지원을 받아 산학연이 필요로 하는 펌프 계측기 부품 소재 및 공정 특성을 평가하기 위한 장치와 절차를 개발하였다. 이를 이용해 보급되는 기술 data는 진공부품 및 장비 국산화, 국산제품 신뢰성 제고, 검증부품 사용을 통한 장비 품질 향상, 독자적 장비 기술 확보, 생산품 품질관리 등에 쓰이고 있다. 한국 표준연구원 진공센터의 교정 및 시험 능력은 ISO 9001 인증 획득과 국제 전문가의 review를 거쳐, 국제기구 측정능력표에 등재되어 있어 국제적 신뢰도도 확보하고 있다. 정기적인 진공기술 교류회를 개최하고 진공기술 홈페이지를 운영 하는 등 산학연 정보 교류 및 협력 네트워킹 활성화를 위해 노력한 바 있으며 이 분야의 연구 성과는 '국가 우수 연구성과 100선'에 선정된 바 있고, 산업자원부 지정 '산학연 연계 우수사례' 첫 번째로 선정되기도 하였다. 2008년부터는 진공기술 교류회 등을 통한 네트워킹 활동으로 도출된 기술 수요에 따라 대기업과 중소기업 학교 연구소들과 함께 진공공정 실시간 측정 진단 기술과 센서 개발 연구, 그리고 이들 개발품의 신뢰성 검증 및 평가 기술 개발을 위해 노력하고 있다.

  • PDF

젖소의 초음파 유도 채란율에 대한 FSH 전처리 효과의 비교 (Effect of FSH Pretreatment on Follicle Development and Oocyte Recovery by Ultrasound-guided Aspiration in Holstein Heifers)

  • 박충생;조성근;이정규;강태영;박성재;공일근;최민철
    • 한국가축번식학회지
    • /
    • 제21권2호
    • /
    • pp.147-156
    • /
    • 1997
  • Ultrasound-guided follicular aspiration was performed in Holstein heifers once weekly with or without pretreatment of single or multiple decreasing doses using a total of 400 mg FSH. Oocytes were aspirated with a 6.5 MHz convex-array ultrasound trasducer designed for intravaginal use. All the visible follicles larger than 4 mm in diameter were punctured with a 17 gauge, 55 cm needle at each aspiration session and the follicular fluids containing oocytes were obtained by vacuum suction. The results obtained were as follows: As a preliminary experiment, the recovery rates of folicular oocytes by ultrasound-guided aspiration from the isolated ovaries of Korean native cows were compared between suction methods using manual syringe or vacuum pump. The recovery rate of oocytes using vacuum pump (80.7%) was significantly (P<0.05) higher than that using manual syringe (47.1%). The follicles were counted by their size in diameter with ultrasound image, and recovery rates and grades of follicular oocytes collected by ultrasound-guided aspiration were investigated in Holstein heifers pretreated with or without FSH. A group of heifiers were injected with multiple decreasing doses (twice a day for 3 days) of a total of 400 mg FSH. The other 2 groups were injected with a single dose of 400 mg FSH mixed with 25% PVP. Ultrasound observation of follicle population and/or ultrasound-guided transvaginal oocyte aspiration were performed 12 hrs following the last FSH injection in the multiple dose group, and 48 or 60 hrs after FSH injection in the single dose groups. Most of the visible follicles had small size of less than 3 mm in diameter in unstimulated heifers (71.0%), but medium size in all the heifers treated with FSH. (70.5 to 92.8%). The number of OPU follicles per session (4.6$\pm$1.9) were much less, compared to the vilsible follicle counts (9.7$\pm$2.2), in the nustimulated heifers due to the small dominant follicles. Among 4 goups of heifers the most visible as well as OPU follicles were observed in the heifers at 60 hrs following treatment of a single dose of 400 mg FSH (21.2$\pm$2.3 and 21.0$\pm$2.0), and the differences in both the follicle counts between the groups was found significant (P<0.05) The rates of oocyte recovery from the follicles by ultrasound-guilded aspiration were varied 46.3 to 75.0% in the heifers unstimulated and treated with a single dose of 400 mg FSH, but the group difference was not significant. The number of recovered oocytes per session a, pp.ared to be highest at aspiration at 60 hrs following single FSH (10.6$\pm$2.2) than at aspiration at 48 hrs after single FSH (7.8$\pm$2.7) or in the unstimulated heifers (3.4$\pm$3.0). The proportion of grade I and II oocytes to all oocytes collected was varied 31.8 to 64.0% between the groups. However, there was found no significant difference in both the number of oocytes recovered per session and the percentage and the percentage of grade I and II oocytes. From the above results it was concluded that the more oocytes of superior quality might be recovered economically by ultrasound-guided aspiration at 60 hrs following the pretreatment of a single dose of 400 mg FSH and by suction using a vacuum pump system of about negative pressure of 75 to 85 mmHg.

  • PDF

DNA 검정우에서 FSH 호로몬 투여가 난포란의 채란율에 미치는 영향

  • 진종인;이명열;박준규;이지삼;정장용;박희성
    • 한국수정란이식학회:학술대회논문집
    • /
    • 한국수정란이식학회 2002년도 국제심포지엄
    • /
    • pp.87-87
    • /
    • 2002
  • 초음파기기를 이용한 난포란의 채란 기술은 유전적으로 우수한 수정란의 다량확보가 가능함으로써 가축개량에 널리 응용할 수 있다. 그러나 초음파유도 난포란의 채란은 무엇보다도 회수율과 회수한 난포란의 질적 등급의 개선이 이루어져야 할 것이다. 본 연구는 등지방층두께, 일당증체량, 근내지방도 및 배최장근 단면적에 연관된 DNA marker가 검정된 한우로부터 FSH(FOLLTROPIN-V, Vetrepharm, Canada)를 투여하여 FSH 투여전.후의 포의 발달율과 등급별 회수율을 조사하였다. 공시동물의 발정주기에 관계없이 매주 무처리와 채란 12시간 전에 FSH를 각각 l00mg 과 200mg을 근육 주사하여 난포란의 채취를 유토하였다. 난소내 난포란의 채란은 SONOACE-600형 (Medison CO., 한국) 초음파기기를 사용하여 모니터 상에 검게 나타나는 난포를 17-gauge needle (Cook, Australia) 로써 70mmHg로 유지된 regulated vacuum pump를 이용하여 모두 채란하였으며, 소난포는 손가락 촉지를 이용하여 채란하였다. 난포의 크기는(large : $\geq$6mm, medium : 2-6mm, small $\leq$2mm) 무처리구에서 small(56.6%), medium(33.0%), large follicles(10.4%) 순으로 나타났으며, 전체 난포수는 106(8.2$\pm$3.6개) 였다. FSH 200mg 투여구에서는 medium(47.5%), small(32.5%), large follicles(20.0%) 순으로 나타났으며, 전체난포수는 40(10.0$\pm$2.2개) 였다. FSH l00mg 투여구에서는 medium(45.6%), small(43.5%), large follicles (10.9%) 순으로 나타났으며, 전체 난포는 92(7.7$\pm$2.5개) 였다. FSH 투여전 초음파 image 상으로 관찰한 난포수와 FSH 투여 후 초음파기기와 손가락 촉지를 이용하여 난포의 발달 및 난포란의 채란율은 200mg 투여 구에서는 투여 전에 4.3$\pm$0.6개였으나 투여 후에는 9.3$\pm$2.1개로 증가하였으며, 채란율은 75.0% 였다. l00mg 투여구에서도 투여 전후에 각각 5.3$\pm$1.2개 및 8.2$\pm$2.3개였으며, 채란율은 81.6%였다. 난포란의 채란율은 무처리구에서 88.7%(7.2$\pm$3.9개)로 나타났으며, 회수한 난포란의 등급은 각각 0.0%(GI), 5.3%(GII), 28.T%(GIII), 66.0%(GIV)로 나타났다. FSH 200mg 투여구의 채란율은 87.5%(8.8$\pm$2.6개)로 나타났으며, 등급별회수율은 GI(2.8%), GII(8.6%), GIII(34.3%), GIV(54.3%)으로 나타났다. 뿐만 아니라 FSH 100mg 투여구에서도 회수율은 89.1%(6.8$\pm$5.2개)였으며, 등급별 회수율은 각각 GI(8.5%), GII(13.4%), GIII(43.9%), GIV(34.2%)로 나타났다.

  • PDF