• Title/Summary/Keyword: Vacuum Extraction

Search Result 160, Processing Time 0.045 seconds

Analysis of Soil Vacuum Extraction using Analytical Solution of Groundwater Flow (지하수 흐름의 해석해를 이용한 토양진공추출 해석)

  • Kim, Min-Hwan;Lee, Hak;Han, Dong-Jin
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.5
    • /
    • pp.139-145
    • /
    • 2009
  • An analytical solution of groundwater flow is applied to design soil vacuum extraction for removing volatile organic compounds from the unsaturation zone. The governing equation of gas or vapor flow in porous media is nonlinear in that gas density depends on gas pressure. A linear equation suggested by researcher is similar to that of groundwater flow. The pressure drawdowns of confined and leaky aqufiers are calculated using Massmann's field data, and the pressure drawdowns are compared. A solution of Theis equation calculated by Massmann is modified using GASSOLVE9 program in this paper. The pressure drawdown using Hantush's analytical solution for leaky aquifer also compared to that of Massmann. Hantush's analytical solution gives good approximations to pressure drawdown.

A case of scalp abscess caused by Achromobacter xylosoxidans after vacuum delivery (진공분만으로 출생한 신생아에서 발생한 Achromobacter xylosoxidans에 의한 두피 농양 1례)

  • Park, Eun-Young;Kwon, Moon-Kyung;Min, Seon-Jeong;Hwang, Hyung-Sik
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.4
    • /
    • pp.451-454
    • /
    • 2006
  • Achromobacter xylosoxidans is an aerobic gram-negative bacillus that may cause opportunistic infections in immunocompromized patients and newborns. Neonatal scalp abscess is generally a complication of fetal scalp monitoring and is typically polymicrobial. We present a case of a newborn, delivered by vacuum extraction, who developed a scalp abscess that yielded growth of Achromobacter xylosoxidans.

Transparent Conducting Zinc-Tin-Oxide Layer for Application to Blue Light Emitting-diode

  • Kim, Do-Hyeon;Kim, Gi-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.346.2-346.2
    • /
    • 2014
  • To use the GaN based light-emitting diodes (LEDs) as solid state lighting sources, the improvement of light extraction and internal quantum efficiency is essential factors for high brightness LEDs. In this study, we suggested the new materials system of a zinc tin oxide (ZTO) layer formed on blue LED epi-structures to improve the light extraction. ZTO is a representative n-type oxide material consisted of ZnO and SnO system. Moreover, ZTO is one of the promising oxide semiconductor material. Even though ZTO has higher chemical stability than IGZO owing to its SnO2 content this has high mobility and high reliability. After formation of ZTO layer on p-GaN layer by using the spin coating method, structural and optical properties are investigated. The x-ray diffraction (XRD) measurement results show the successful formation of ZTO. The photoluminescence (PL) and absorption spectrum shows that it has 3.6-4.1eV band gap. Finally, the light extraction properties of ZTO/LED chip using electroluminescence (EL) measurement were investigated. The experimental and theoretical analyses were simultaneously conducted.

  • PDF

The effects of solenoid magnet on plasma extraction in Filtered Vacuum Arc Source (FVAS) (자장여과 아크 소스에서 각 전자석이 플라즈마 인출에 미치는 영향)

  • 김종국;변응선;이구현;조영상
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.4
    • /
    • pp.431-439
    • /
    • 2001
  • In this paper, the a-Diamond films were synthesized using filtered vacuum arc source (FVAS), FVAS was composed of a torus structure with bending angle of 60 degree. The radius of torus was 266 mm, the radius of plasma duct was 80 mm and the total length was 600 mm. The magnet parts were composed of one permanent magnet and five solenoid magnets. The plasma duct was electrically isolated from the ground so that a bias voltage could be applied. The baffles inside plasma duct were installed in order to prevent the recoil effect of macro-particles. Cathode was made of graphite with 80 mm in diameter. The effects of solenoid magnet on plasma extraction were investigated by computer simulation and experiment using Taguchi's methode. The source and extraction magnet affected the arc stabilization. The extraction beam current was maximized with low value of the source magnet current and high value of the filtering magnet current. The beam current density was 3.2 mA/$\textrm{cm}^2$ and average deposition rate was 5 $\AA$/sec when the currents of arc discharge, source, extraction, bending, deflection and outlet magnet were 30 A, 1 A, 3 A, 5 A, 5 A, and 5 A, respectively. The beam current density and the efficiency of beam transportation were increased with the positive bias voltage of the plasma duct.

  • PDF

Application of Polystyrene/SiO2 Core-shell Nanospheres to Improve the Light Extraction of GaN LEDs

  • Yeon, Seung Hwan;Kim, Kiyong;Park, Jinsub
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.314.2-314.2
    • /
    • 2014
  • To improve the optical and electrical properties of commercialized GaN-based light-emitting diodes (LEDs), many methods are suggested. In recent years, great efforts have been made to improve the internal quantum efficiency and light extraction efficiency (LEE) and promising approaches are suggested using a patterned sapphire substrate (PSS), V-pit embedded LED structures, and silica nanostructures. In this study, we report on the enhancement of photoluminescence (PL) intensity in GaN-based LED structures by using the combination of SiO2 (silica) nanospheres and polystyrene/SiO2 core-shell nanospheres. The SiO2 nanospheres-coated LED structure shows the slightly increased PL intensity. Moreover the polystyrene/SiO2 core-shell nanospheres-coated structure shows the more increase of PL intensity comparing to that of only SiO2 spheres-coated structure and the conventional structure without coating of nanospheres. The Finite-difference time-domain (FDTD) simulation results show corresponding result with experimentally observed results. The mechanism of enhancement of PL intensity using the coating of polystyrene/SiO2 core-shell nanospheres on LED surface can be explained by the improvement in extraction efficiency by both increasing the probability of light escape by reducing Fresnel reflection and by multiple scattering within the core-shell nanospheres.

  • PDF

A compact mass spectrometer for plasma ion species analysis

  • ;S.A. Nikiforov
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.185-185
    • /
    • 2000
  • 플라즈마 연구 및 응용에서 플라즈마를 구성하는 이온에 대한 정보를 얻는 것은 중요하다. 특히 플라즈마 진단, 박막 증착, 플라즈마 코팅, 플라즈마 이온주입 등과 같은 플라즈마 프로세싱에서 이온들의 종류 구성비율 및 분포는 매우 중요하다. 질량분석기는 대개 큰 규모로 복잡하고 값비싼 경향이 있다. 플라즈마 교란을 최소화하면서 충분한 질량분해능을 갖고 국소적으로 이온들을 분석할 수 있는 간단하고 작은 규모의 값싼 질량분석기가 필요하다. 본 연구에서는 플라즈마 내에 존재하는 이온을 분석하기 위하여 간단하고 작은 규모의 값싼 프라즈마 이온 질량분석기를 설계, 제작하였다. 이온 질량분석기는 ion extraction part, double focusing sector magnet, ion collector로 구성되어 있다. 플라즈마에 잠기는 ion extraction part의 외부 전극에 Al2O3를 코팅하여 플라즈마 교란을 최소화하였다. 이온들의 공간적 분포를 측정하기 쉽게 하기 위하여 ion extraction part를 이동하여도 질량여과기를 통과한 후에 접속되는 초점의 위치가 Faraday ion collector 에 고정되도록 ion optical system을 설계하였다. Extracting electrode에 의하여 가속된 이온들이 sector magnet에 들어갈 때 평행이 되게 하기 위하여 여러 개의 미세구조를 갖는 Mo grids를 사용하고 immersion lens를 넣어서 이온 광학 시스템을 구성하였다. extraction electrode와 sector magnet 사이에 보조 electrode를 하나 더 넣어서 extracting electrode와 보조 electrode 사이에 immersion lens를 만들었다. 질량여과기로는 permanent magnet sector와 time-varying electrical field를 결합하여 사용하였다. Extracting electrode에 1kV 정도의 전압을 인가하여 이온들을 가속시키고 sector magnet에 톱니파 형태의 전압을 인가하여 mass spectrum을 얻었다. 이온 질량분석기를 플라즈마 장치에 적용하여 질량분해능 등의 특성을 연구하였다. Hot cathode discharge와 inductively coupled RF discharge에서 발생된 질소 플라즈마를 구성하는 이온들의 종류와 그 구성비율을 연구하였다.

  • PDF

다중상 추출조건에서 L-NAPL의 토양이동 특성

  • 김성용;이인원;이승우;장윤영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.282-284
    • /
    • 2003
  • Multi-phase extraction of LNAPLs not only floating on groundwater but also captured in soil pores was studied in a simulated soil system. The extraction rate of LNAPL under the MPE conditions was much higher than the rate under usual hydraulic gradient conditions. The WE might be especially useful for recovery of oils in fine-textured soils such as clay-dominant soils. The vacuum-enhanced transport of LNAPL in soils also depended on the properties of LNAPL such as viscosity and density as well as soil textures.

  • PDF

Design of the vacuum pumping system for the KSTAR NBI device (KSTAR 중성빔 입사(NBI) 장치 배기계통 설계)

  • 오병훈;인상렬;조용섭;김계령;최병호
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.4B
    • /
    • pp.548-555
    • /
    • 1999
  • The NBI (Neutral BGeam Injection) System for the Korea Superconducting Tokamak Advanced Research (KSTAR) is composed of ion sources, neutralizers, bending magnets, ion dumps, and calorimeter. The vacuum chamber, in which all of the beam line components are enclosed, is composed of differential pumping system for the effective transfer of the neutral beams. The needed pumping speeds of each of the divided vacuum chamber and the optimized gas flow rate ot the neutralizer were calculated with the help of the particle balance equations. The minimum gas flow rate to the ion sources for producing needed beam current (120kV, 65A, 78MW), the pressure distributions in the vacuum chamber for minimizing re-ionization loss, and the beam loss rate on the beam line components were used as the input in the calculation. Also the scenario for short pulse operation was determined by analysing the time dependent equations. It showed that beam extraction during less than 0.5 sec could be made only with TMP.

  • PDF

Antioxidant Activity of Stevia Leaf Extracts Prepared by Various Extraction Methods (다양한 추출방법으로 조제된 스테비아 잎 추출물의 항산화 활성)

  • Kim, Jae-Hun;Sung, Nak-Yun;Kwon, Sun-Kyu;Jung, Pil-Moon;Choi, Jong-Il;Yoon, Yo-Han;Song, Beom-Seok;Yoon, Tai-Young;Kee, Hee-Jin;Lee, Ju-Woon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.2
    • /
    • pp.313-318
    • /
    • 2010
  • This study was carried out to evaluate the antioxidant activity of stevia extracts from Stevia rebaudiana Bertoni leaves. Stevia extracts were prepared by three different methods including hot water extraction (HWE) at $120^{\circ}C$ for 4 hr, vacuum extraction (VE) at $65^{\circ}C$ for 4 hr under 0.08 MPa, and fermentation of hot water extract (FHWE) using Lactobacillus buchneri. The antioxidant activities measured by radical scavenging activity, ferric-reducing antioxidant potential ability, and thiobarbituric acid reactive substance showed the highest values in vacuum extract. Also, the antioxidant activities of all extracts were higher than those of stevioside and rebaudioside at the same concentrations, known as the major active components in stevia. To define the antioxidative compound in stevia extracts, the total phenol content was measured, and it was shown that the highest contents of total phenolic compounds were in vacuum extract. These results suggest that the antioxidant activity of stevia extract was due to the phenolic compound components. In addition, vacuum extraction was the proper method to prepare stevia extract with higher antioxidant activity.