• Title/Summary/Keyword: VSCS

Search Result 49, Processing Time 0.023 seconds

Method for Removing Reaching Phase in Variable Structure Control Systems Using Bell Type Switching Function (Bell형 스위칭 함수를 이용한 가변구조제어계의 도달기간 제거방법)

  • 김윤업;윤종일;곽군평
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.8
    • /
    • pp.1269-1275
    • /
    • 2002
  • This paper presents a new method for removing reaching phase in variable structure control systems using Bell type switching function. By proposed method, during the entire control process reaching phase is removed. For effective speed control of trapezoidal type brushless DC motor, a time varying switching function based speed controller is developed as illustration.

PI-type Variable Structure Control with High Speed Reaching Mode (빠른 도달 속도를 가지는 PI형 가변구조 제어)

  • Shin, Seung-Min;Jun, Kyung-Han;Jun, Hae-Jin;Choi, Bong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.236-239
    • /
    • 2001
  • In this paper, we present the new PI-type VSC(variable structure control). In general, conventional VSCs with a discontinuous reaching law have a chattering problem, and with a PI-type reaching law have a slow reaching speed characteristic. To solve this problem, we propose the reaching law consists of a discontinuous and a PI-type reaching law to obtain a high speed reaching mode and a non-chattering characteristic at the same time. Simulation results show the effectiveness of a proposed scheme.

  • PDF

A variable structure controller with a PI-type reaching law (PI 형 도갈법칙을 가지는 가변구조 제어)

  • Chun, Kyung-Han;Lee, Yun-Jung;Choi, Bong-Yeol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.3
    • /
    • pp.214-218
    • /
    • 1997
  • We propose a VSC(Variable Structure Controller) with a PI-type reaching law. In General, conventional VSCs with a reaching law including a discontinuous term have the chattering problem, and thus the system may be unstable due to the disregarded high frequency dynamics in the modeling process. To resolve this problem, the PI-type reaching law is proposed in this paper. The proposed reaching law makes it easy to determine the reaching dynamics as well as the reaching time by utilizing the 2nd-order system analysis. Furthermore, since the discontinous term is not involved in the reaching law, the chattering is considerably reduced. To show the effectiveness of the proposed scheme, the stability of the proposed system is proved by Lyapunov method and the computer simulations are performed for the Ball Balance System.

  • PDF

Voltage Control in a Novel Three-Phase Line Interactive UPS System with Parallel-Series Active Power Line Conditioning Capabilities using AC Line Reactor (AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 Line-Interactive UPS 시스뎀의 전압제어)

  • Ji, Jun-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.6
    • /
    • pp.1072-1077
    • /
    • 2006
  • In this paper a novel 3-phase line interactive UPS(Uninterruptible Power Supply) system with parallel-series active power-line conditioning capability using AC line reactor and two four-leg PWM VSCs(Voltage Source Converters) is proposed. And the strategy of voltage control in proposed UPS system is explained. The objective of voltage control in parallel(shunt) and series PWM VSC of proposed UPS system is to guarantee satisfactory characteristics in steady state and transient state.

  • PDF

Improved Circuit Model for Simulating IGBT Switching Transients in VSCs

  • Haleem, Naushath Mohamed;Rajapakse, Athula D.;Gole, Aniruddha M.
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1901-1911
    • /
    • 2018
  • This study presents a circuit model for simulating the switching transients of insulated-gate bipolar transistors (IGBTs) with inductive load switching. The modeling approach used in this study considers the behavior of IGBTs and freewheeling diodes during the transient process and ignores the complex semiconductor physics-based relationships and parameters. The proposed circuit model can accurately simulate the switching behavior due to the detailed consideration of device-circuit interactions and the nonlinear nature of model parameters, such as internal capacitances. The developed model is incorporated in an IGBT loss calculation module of an electromagnetic transient simulation program to enable the estimation of switching losses in voltage source converters embedded in large power systems.

Beneficial Effect of Korea Red Ginseng on Halitosis; Attenuation of H2S Induced Inflammatory Mediators and cystathionine γ-lyase Expression (고려홍삼의 구강악취 억제기능; H2S 생성에 따른 염증매개 유전자 및 cystathionine γ-lyase의 약화기능)

  • Choi, Ki-Seok;Lee, So-Jung;Lee, Jeong-Sang;Hong, Kyung-Sook;Kim, Jeong-Gon;Kim, Yoon-Jae;Hahm, Ki-Baik
    • Journal of Ginseng Research
    • /
    • v.33 no.4
    • /
    • pp.367-377
    • /
    • 2009
  • Halitosis is a generally accepted marker of diseases in the oral cavity and of systemic and gastrointestinal disorders. Based on these authors' previous findings (that (1) there is a close association between H. pylori infection and halitosis; (2) Korea red ginseng may suppress the colonization of H. pylori, fight H. pylori-induced cytotoxicity, and impose significant anti-inflammatory actions in patients with chronic gastritis; and (3) H. pylori infection is linked with the generation of significant levels of volatile sulfur compounds (VSCs), and the levels of VSCs correlate significantly with H. pylori-associated mucosal damages), in the current study, the authors documented the molecular mechanisms of Korea red ginseng's efficacy in ameliorating halitosis. When the RAW 264.7 cells were treated with the $H_2S$ releasing compound NaHS, the mRNA expression of cystathionine ${\gamma}$-lyase (CSE), IL-6, COX-2, and iNOS were more significantly induced compared with the vehicle-treated group. The cytoskeletal components of ezrin's and moesin's mRNA expressions were elevated by NaHS treatment accompanied by the activation of MAPK, p38, and ERK. Korea red ginseng pretreatment reduced both the NaHS-induced CSE expression and the proinflammatory genes (e.g., IL-6, COX-2, and iNOS) in a concentration-dependent manner. The ERM expression and the phosphorylation of p38 were also significantly reduced by Korea-red-ginseng pretreatment. Overall, Korea red ginseng pretreatment imposed significant anti-inflammatory effects through the downregulation of the NaHS-triggered proinflammatory gene expression, CSE, and ERM mRNA expression. Korea red ginseng could thus be said to be a key remedy of halitosis and to be effective in relieving gastric inflammation.

Loss Analysis and Comparison of High Power Semiconductor Devices in 5MW PMSG MV Wind Turbine Systems

  • Lee, Kihyun;Suh, Yongsug;Kang, Yongcheol
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1380-1391
    • /
    • 2015
  • This paper provides a loss analysis and comparison of high power semiconductor devices in 5MW Permanent Magnet Synchronous Generator (PMSG) Medium Voltage (MV) Wind Turbine Systems (WTSs). High power semiconductor devices of the press-pack type IGCT, module type IGBT, press-pack type IGBT, and press-pack type IEGT of both 4.5kV and 6.5kV are considered in this paper. Benchmarking is performed based on the back-to-back type 3-level Neutral Point Clamped Voltage Source Converters (3L-NPC VSCs) supplied from a grid voltage of 4160V. The feasible number of semiconductor devices in parallel is designed through a loss analysis considering both the conduction and switching losses under the operating conditions of 5MW PMSG wind turbines, particularly for application in offshore wind farms. This paper investigates the loss analysis and thermal performance of 5MW 3L-NPC wind power inverters under the operating conditions of various power factors. The loss analysis and thermal analysis are confirmed through PLECS Blockset simulations with Matlab Simulink. The comparison results show that the press-pack type IGCT has the highest efficiency including the snubber loss factor.

The Design of Variable Structure Position Controller for Bushless DC Motor Using New Switching Function (새로운 스위칭 함수를 이용한 브러시리스 직류 전등기의 가변 구조 위치 제어기 설계)

  • Chun, Hee-Young;Park, Gwi-Tae;Koh, Po-Hyoung;Lee, Sang-Lak;Song, Myung-Hyun;Yeo, Hyeong-Gee
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.336-339
    • /
    • 1990
  • This paper discusses the application of VSCS(Variable Structure Control System) to position control of a trapezoidal type brushless DC motor. In order to simplify the overall control system and to improve the robustness, a new switching function which is composed of linear combination of only measurable state variables Sr(x) and Sr(x) is defined. The proposed new switching function is implemented using a digital signal processor(DSP). A general PWM amplifier is replaced by an ON-OFF pattern generator for the hardware simplification and digitalization. Experimental results are given to demonstrate the validity of the proposed control method.

  • PDF

Control Strategy for Three-Phase Grid-Connected Converters under Unbalanced and Distorted Grid Voltages Using Composite Observers

  • Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.469-478
    • /
    • 2013
  • This paper proposes a novel scheme for the current controller for the grid-side converter (GSC) of permanent-magnet synchronous generator (PMSG) wind turbines to eliminate the high-order harmonics in the grid currents under grid voltage disturbances. The voltage unbalance and harmonics in three-phase systems cause grid current distortions. In order to mitigate the input current distortions, multi-loop current controllers are applied, where the positive-sequence component is regulated by proportional-integral (PI) controllers, and the negative-sequence and high-order harmonic components are regulated by proportional-resonance (PR) controllers. For extracting the positive/negative-sequence and harmonic components of the grid voltages and currents without a phase delay or magnitude reduction, composite observers are applied, which give faster and more precise estimation results. In addition, an active damping method using PR controllers to damp the grid current component of the resonant frequency is employed to improve the operating stability of VSCs with inductor-capacitor-inductor (LCL) filters. The validity of the proposed method is verified by simulation and experimental results.

A Novel Three-Phase Line-Interactive UPS System having AC Line Reactor and Parallel-Series Active Filters (AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 라인 인터렉티브 무정전전원장치 시스템)

  • Ji Jun-Keun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.06a
    • /
    • pp.193-197
    • /
    • 2004
  • The four-leg Voltage Source Converter(VSC) can use the DC link voltage effectively by the 3-D SVPWM method. Hence the DC battery voltage can be reduced by $15\%$ in comparison to that of the conventional line-interactive UPS system. In this paper a novel line interactive Uninterruptible Power Supply(UPS) using the two four-leg VSCs is proposed. One VSC is in parallel with the ac link reactor of the power source side, and the other is in series with the load. The parallel four-leg voltage source inverter controls the three-phase line voltage independently in order to control the line reactor current indirectly. It eliminates the neutral line current and the active ripple power of the source side using the pqr theory so that unity power factor and the sinusoidal source current can be achieved even though both the source and the load voltages have zero sequence components. The series four-leg voltage source inverter compensates the line voltage and allows it to be balanced and harmonic-free. Both of the parallel and series four-leg voltage source inverters always act as independently controllable voltage sources, so that the three-phase output voltage shows a seamless transition to the backup mode. The feasibility of the proposed UPS system has been investigated and verified through computer simulations results.

  • PDF