• Title/Summary/Keyword: VP1-2A

Search Result 430, Processing Time 0.028 seconds

Comparison of Accuracy and Output Waveform of Devices According to Rectification Method (정류방식에 따른 장치의 정확도와 출력 파형의 비교)

  • Lee, In Ja
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.603-610
    • /
    • 2018
  • This study examined the following: accuracy of the exposure conditions in the inverter device and three-phase device; output waveform over the exposure conditions; and average and standard deviation of the output waveform. After assessing whether the dose corresponding to the theoretical dose was presented, the following conclusions were obtained: 1. The accuracy of the tube voltage(kVp) and tube current(mA) exposure time(sec) was within the tolerable level prescribed in Korea's Safety Management Standards. In the error, Inverter device was large the tube voltage and exposure time, the three-phase device was large the tube current. 2. In terms of the output waveform of the exposure conditions and the average and standard deviation of the output waveform, the higher tube voltage and larger tube current resulted in greater standard deviation in pulsation. Moreover, the standard deviation of pulsation was shown to be greater in the inverter device than the three-phase device; there was also greater standard deviation in the inverter device considering the exposure time. 3. Regarding the exposure conditions over the output dose, all linearity showed the coefficient of variation which had an allowable limit of error within 0.05. Although the output dose ratio for the inverter device was 1.00~1.10 times no difference that of the three-phase device, there was almost no difference in dose ratio between the tube currents.

Measurement of Image Quality According to the Time of Computed Radiography System (시간에 따르는 CR장비의 영상의 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Hwang, Sun-Kwang;Lee, Ik-Pyo;Kim, Ki-Won;Jung, Jae-Yong;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.365-374
    • /
    • 2015
  • The regular quality assurance (RQA) of X-ray images is essential for maintaining a high accuracy of diagnosis. This study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) of a computed radiography (CR) system for various periods of use from 2006 to 2015. We measured the pre-sampling MTF using the edge method and RQA 5 based on commission standard international electro-technical commission (IEC). The spatial frequencies corresponding to the 50% MTF for the CR systems in 2006, 2009, 2012 and 2015 were 1.54, 1.14, 1.12, and $1.38mm^{-1}$, respectively and the10% MTF for 2006, 2009, 2012, and 2015 were 2.68, 2.44, 2.44, and $2.46mm^{-1}$, respectively. In the NPS results, the CR systems showed the best noise distribution in 2006, and with the quality of distributions in the order of 2015, 2009, and 2012. At peak DQE and DQE at $1mm^{-1}$, the CR systems showed the best efficiency in 2006, and showed better efficiency in order of 2015, 2009, and 2012. Because the eraser lamp in the CR systems was replaced, the image quality in 2015 was superior to those in 2009 and 2012. This study can be incorporated into used in clinical QA requiring performance and evaluation of the performance of the CR systems.

Feasibility of the Threshold-Based Quantification of Myocardial Fibrosis on Cardiac CT as a Prognostic Marker in Nonischemic Dilated Cardiomyopathy

  • Na Young Kim;Dong Jin Im;Yoo Jin Hong;Byoung Wook Choi;Seok-Min Kang;Jong-Chan Youn;Hye-Jeong Lee
    • Korean Journal of Radiology
    • /
    • v.25 no.6
    • /
    • pp.540-549
    • /
    • 2024
  • Objective: This study investigated the feasibility and prognostic relevance of threshold-based quantification of myocardial delayed enhancement (MDE) on CT in patients with nonischemic dilated cardiomyopathy (NIDCM). Materials and Methods: Forty-three patients with NIDCM (59.3 ± 17.1 years; 21 male) were included in the study and underwent cardiac CT and MRI. MDE was quantified manually and with a threshold-based quantification method using cutoffs of 2, 3, and 4 standard deviations (SDs) on three sets of CT images (100 kVp, 120 kVp, and 70 keV). Interobserver agreement in MDE quantification was assessed using the intraclass correlation coefficient (ICC). Agreement between CT and MRI was evaluated using the Bland-Altman method and the concordance correlation coefficient (CCC). Patients were followed up for the subsequent occurrence of the primary composite outcome, including cardiac death, heart transplantation, heart failure hospitalization, or appropriate use of an implantable cardioverter-defibrillator. The Kaplan-Meier method was used to estimate event-free survival according to MDE levels. Results: Late gadolinium enhancement (LGE) was observed in 29 patients (67%, 29/43), and the mean LGE found with the 5-SD threshold was 4.1% ± 3.6%. The 4-SD threshold on 70-keV CT showed excellent interobserver agreement (ICC = 0.810) and the highest concordance with MRI (CCC = 0.803). This method also yielded the smallest bias with the narrowest range of 95% limits of agreement compared to MRI (bias, -0.119%; 95% limits of agreement, -4.216% to 3.978%). During a median follow-up of 1625 days (interquartile range, 712-1430 days), 10 patients (23%, 10/43) experienced the primary composite outcome. Event-free survival significantly differed between risk subgroups divided by the optimal MDE cutoff of 4.3% (log-rank P = 0.005). Conclusion: The 4-SD threshold on 70-keV monochromatic CT yielded results comparable to those of MRI for quantifying MDE as a marker of myocardial fibrosis, which showed prognostic value in patients with NIDCM.

The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor (통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.100-108
    • /
    • 2012
  • The purpose of the study was to evaluate the influence of shading and ventilation on Mean Radiant Temperature(MRT) of the outdoor space at a summer outdoor. The Wind Speed(WS), Air Temperature(AT) and Globe Temperature(GT) were recorded every minute from $1^{st}$ of May to the $30^{th}$ of September 2011 at a height of 1.2m above in four experimental plots with different shading and ventilating conditions, with a measuring system consisting of a vane type anemometer(Barini Design's BDTH), Resistance Temperature Detector(RTD, Pt-100), standard black globe(${\O}$ 150mm) and data acquisition systems(National Instrument's Labview and Compfile Techs' Moacon). To implement four different ventilating and shading conditions, three hexahedral steel frames, and one natural plot were established in the open grass field. Two of the steel frames had a dimension of $3m(W){\times}3m(L){\times}1.5m(H)$ and every vertical side covered with transparent polyethylene film to prevent lateral ventilation(Ventilation Blocking Plot: VP), and an additional shading curtain was applied on the top side of a frame(Shading and Ventilation Blocking Plot: SVP). The third was $1.5m(W){\times}1.5m(L){\times}1.5m(H)$, only the top side of which was covered by the shading curtain without the lateral film(Shading Plot: SP). The last plot was natural condition without any kind of shading and wind blocking material(Natural Open Plot: NP). Based on the 13,262 records of 44 sunny days, the time serial difference of AT and GT for 24 hour were analyzed and compared, and statistical analysis was done based on the 7,172 records of daytime period from 7 A.M. to 8 P.M., while the relation between the MRT and solar radiation and wind speed was analyzed based on the records of the hottest period from 11 A.M. to 4 P.M.. The major findings were as follows: 1. The peak AT was $40.8^{\circ}C$ at VP and $35.6^{\circ}C$ at SP showing the difference about $5^{\circ}C$, but the difference of average AT was very small within${\pm}1^{\circ}C$. 2. The difference of the peak GT was $12^{\circ}C$ showing $52.5^{\circ}C$ at VP and $40.6^{\circ}C$ at SP, while the gap of average GT between the two plots was $6^{\circ}C$. Comparing all four plots including NP and SVP, it can be said that the shading decrease $6^{\circ}C$ GT while the wind blocking increase $3^{\circ}C$ GT. 3. According to the calculated MRT, the shading has a cooling effect in reducing a maximum of $13^{\circ}C$ and average $9^{\circ}C$ MRT, while the wind blocking has heating effect of increasing average $3^{\circ}C$ MRT. In other words, the MRT of the shaded area with natural ventilation could be cooler than the wind blocking the sunny site to about $16^{\circ}C$ MRT maximum. 4. The regression and correlation tests showed that the shading is more important than the ventilation in reducing the MRT, while both of them do an important role in improving the outdoor thermal comfort. In summary, the results of this study showed that the shade is the first and the ventilation is the second important factor in terms of improving outdoor thermal comfort in summer daylight hours. Therefore, it can be apparently said that the more shade by the forest, shading trees etc., the more effective in conditioning the microclimate of an outdoor space reducing the useless or even harmful heat energy for human activities. Furthermore, the delicately designed wind corridor or outdoor ventilation system can improve even the thermal environment of urban area.

A Study on the Interior Design Guidelines in consideration of Merchandising of Department Store Supermarket (백화점 수퍼마켓의 머천다이징을 고려한 실내디자인 지침에 관한 연구)

  • Park, Seoung-Zun;Choi, Sang-Hun
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.6
    • /
    • pp.22-29
    • /
    • 2015
  • The purpose of this study is to investigate the details of the overall interior design of the department store supermarket retail space, interior design and development, seeks to help change. In this study, a range of research the department store supermarket located in the major department store. Since 2012, new construction or renewal has been done in a department store, was investigated by selecting a total of five locations of two places in the premium supermarket. Conclusions are as followings ; First, In-store merchandising strategies, store configuration strategy, product mix strategies, and the layout plan considering the advanced strategies. Secondly, the interior guidelines are, (1)VP should be planned as an expression of a company or brand management strategies to visualize a concept image of product planning stages of merchandising to entering the store to induce curiosity to customers. (2)PP is by planning purposes, the use of lighting, directing structure, color harmony, by utilizing such as props and small parts must be able to attract attention. (3)IP is the customer to organize display, depending on the type of the display items to facilitate fraud, and the fixture plan in association with it, the customer selects a product must induced to purchase.

Acoustical Analysis of Phonological Reduction in Conversational Japanese (일본어 회화문에 나타난 축약형의 음운론적 해석과 음향음성학적 분석)

  • Choi, Young-Sook
    • Speech Sciences
    • /
    • v.8 no.4
    • /
    • pp.229-241
    • /
    • 2001
  • Using eighteen texts from various genera of present-day Japanese, I collected phonologically reduced forms frequently observed in conversational Japanese, and classified them in search of a unified. explanation of phonological phenomena. I found 7,516 cases of reduced forms which I divided into 43 categories according to the types of phonological changes they have undergone. The general tendencies are that deletion and fusion of a phoneme or an entire syllable takes place frequently, resulting in the decrease in the number of syllables. From a morphosyntactic point of view, phonological reduction often occurs at the NP and VP morpheme boundaries. The following findings are drawn from phonetical observations of reduction. (1) Vowels are more easily deleted than consonants. (2) Bilabials ([m], [b], and [w]) are the most likely candidates for deletion. (3) In a concatenation of vowels, closed vowels are absorbed into open vowels, or two adjacent vowels come to create another vowel, in which case reconstruction of the original sequence is not always predictable. (4) Alveolars are palatalized under the influence of front vowels. (5) Regressive assimilation takes place in a syllable starting with [r], changing the entire syllable into a phonological choked sound or a syllabic nasal, depending on the voicing of the following phoneme.

  • PDF

Hunt-Hess and Fisher Grades as Predicting Factors for Chronic Hydrocephalus in Surgically Treated Ruptured Aneurysm (수술적 치료를 받은 파열성 뇌동맥류환자에서의 예후와 뇌실-복강 단락술의 예측인자로써의 Hunt-Hess Grade와 Fisher Grade)

  • Hong, Chang Ki;Park, Chong Oon;Hyun, Dong Keun;Ha, Young Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.1
    • /
    • pp.60-65
    • /
    • 2001
  • Objective : The popular grading systems in use, such as Hunt-Hess grade and Fisher scale score, are based primarily on the patient's clinical conditions or computerized tomography score after aneurysmal subarachnoid hemorrhage(SAH). The author investigated whether the need for ventriculoperitoneal(VP) shunt for chronic hydrocephalus and outcome can be predicted by Hunt-Hess grade and Fisher scale. Methods : A series of 146 patients admitted to our hospital from August 1991 to July 1999, who presented with SAH and underwent craniotomy for aneurysm clipping were studied retrospectively. Chronic hydrocephalus was defined as clinically and radiographically demonstrated hydrocephalus that lasted 2 weeks or longer after initial hemorrhage which required shunting. Patients were evaluated based on following factors : Hunt-Hess grade, Fisher scale, age, sex, hypertension, aneurysm location, and intervals from aneurysm rupture to operation. Results : The overall mortality rate of the study group was 8.2%. Hunt-Hess grade(p=0.001) or Fisher scale (p=0.001) at all pretreatment times was significantly correlated with outcome. In addition, there was an increased risk of poor outcome in older age(65<). However, there were statistically no significant relationship between outcome and sex, location of aneurysm, hypertension, and interval from aneurysmal rupture to operation(p>0.05). Of 134 surviving patients, 16 patients(12%) underwent VP shunt placement secondary to chronic hydrocephalus. Hunt-Hess grade(p=0.001) is more predictive of chronic hydrocephalus than Fisher scale(p=0.146). Aneurysm location was significantly correlated with development of chronic hydrocephalus (p<0.05), without significant correlations in sex, age, hypertension. IVH, and ICH. Conclusion : This study suggests that there is a high clinical correlation between outcome and Hunt-Hess grades and Fisher scales on admission, but Hunt-Hess grade is more predictive for chronic hydrocephalus than Fisher scale. In addition, age(<65 yrs) is the significant factor for prediction of outcome. There was a trend of increasing risk for chronic hydrocephalus according to aneurymal location.

  • PDF

Study of Image Properties for Computed Radiography (Computed Radiography의 영상특성에 관한 연구)

  • Ryu, Ki-Hyun;Jung, Jae-Eun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.2
    • /
    • pp.23-31
    • /
    • 2008
  • Computed radiography(CR) has been widely used in the field of diagnostic radiography since digital X-ray image was introduced. The imaging performance of CR system was studied by analyzing the digital image data of the CR images which are the outcomes of the whole imaging system composed of image plate(IP), laser digitizer, analoge-digital convertor, and a given image processing unit. In this study, we used a conventional CR system made by Agfa. From the flat field image of 150$\times$150 image pixels, signal-to-noise ratio(SNR) was calculated. SNR of the CR image increases in proportion to logarithm value of the X-ray exposure irradiated on the IP. SNR is less than about 6 at the exposure below 0.2mR and is more than 10 at the exposure above 0.54mR. In our study, most of images obtained by the smaller exposures less than 2.0mR can not be readable. In general, the minimum value of the SNR ranges from 3 to 5. We obtained modulation transfer function(MTF) by analyzing the bar pattern image which was made under conditions as follows: X-ray tube potential was 55kVp, the IP exposure was 0.54 mR, and the distance between X-ray source to IP was 2m, where bar pattern was located on the IP. MTF is 23% at 2.5lp/mm spatial frequency. Provided that the MTF of noise equivalent modulation is 10%, the CR system has the limiting spatial resolution of 3.2lp/mm. If the image sharpness is evaluated by the spatial frequency where MTF is 50%. the corresponding spatial frequency is 0.5$\sim$0.75lp/mm. MTFA(Modulation Transfer Function Area) is 1.0lp/mm. Compared with the Fuji CR whose MTFA is 1.1lp/mm, Agfa CR in this study shows almost same MTFA performance.

  • PDF

The Structure of Vegetation in Chamaecyparis obtusa Plantations (편백인공림(人工林)의 식생구조(植生構造)에 관(關)한 연구(硏究))

  • Goo, Gwan Hyo;Lee, Kang Young
    • Journal of Korean Society of Forest Science
    • /
    • v.80 no.4
    • /
    • pp.393-407
    • /
    • 1991
  • The vegetation structure within Chamaecyparis obtusa plantation was analyzed for the purpose of applying the effective forestation method for Chmaecyparis obtusa plantation, tending and regeneration in the southern districts of korea. The results were as follows ; 1. The importance percentage was high in the order of Eurya japonica, Rhus verniciflua, Chamaecyparis obtusa, Lindera erythrocarpa, Carpinus laxiflora, Styrax japonica, Viburnum dilatatum, Zanthoxylum piperitum and Smilax china among the vegetation of Chamaecyparis obtusa. Importance percentage of natural seedling of Chamaecyparis obtusa was high in lower story but gradually decreased in middle story. 2. The basal area of upper trees had a negative correlation with the density of natural seedlings in the middle and lower story, and it represents that the basal area of upper trees had some effect on the density of natural seedlings within understories. 3. The rate of the A and B class by Raunkiaer's frequency was higher in the vegetation of middle story than that of lower story. 4. By Morisita's index, the species of Chamaecyparis obtusa, Rhus verniciflua, Lindera erythrocarpa, Smilax china. Callicarpa japonica and Lindera obtusiloba were randomly distributed at lower story, but they were aggregatively distributed at middle story. At all of middle and lower story, Eurya japonica and Viburum dilatatum were randomly distributed, and Carpinus laxiflora, Zanthoxylum piperitum and Picrasma quassioides were aggregatively distributed. 5. The number of appearance species and the value of species diversity in western survey area were more than that of eastern survey area. 6. The value of species diversity at lower story was higher than that of middle story, and it represents that the number of individuals of appearance species was composed more even at lover story than middle story. 7. According to cluster analysis by similarity index, the survey areas were separated from inland and seacoast districts. 8. Judging from each stories ordination analysis by dissimilarity index, the vegetation was separated from lower and middle story, and the vegetation of lower story was more progressed succession stage than that of middle story. 9. In Chamaecyparis obtusa stands, Eurya japonica had a positive correlation with Sorbus alnifolia, Hex macropoda. Ficus erecta and Trachelospermum asiaticum, but it had a negative correlation with Zanthoxylum piperitum, Carpinus laxiflora and Parthenocissus tricuspidata. 10. In estimation of the productivity of Chamaecyparis obtusa stands, the value of SC (Conic surface) and VP (Parabolic volume) for upper trees was 94.5% and 99.63%, respectively and SC and VP of middle story was 5.49% and 0.37%, respectively. In the species of middle story, material productivity was high in order of Eurya japonica. Lindera eryhrocarpa, Rhus verniciflua. Carpinus laxiflora and Styrax japonica.

  • PDF

Vertical root fracture diagnosis in teeth with metallic posts: Impact of metal artifact reduction and sharpening filters

  • Debora Costa Ruiz;Lucas P. Lopes Rosado;Rocharles Cavalcante Fontenele;Amanda Farias-Gomes;Deborah Queiroz Freitas
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.139-145
    • /
    • 2024
  • Purpose: This study examined the influence of a metal artifact reduction (MAR) tool, sharpening filters, and their combination on the diagnosis of vertical root fracture (VRF) in teeth with metallic posts using cone-beam computed tomography (CBCT). Materials and Methods: Twenty single-rooted human premolars - 9 with VRF and 11 without - were individually placed in a human mandible. A metallic post composed of a cobalt-chromium alloy was inserted into the root canal of each tooth. CBCT scans were then acquired under the following parameters: 8 mA, a 5×5 cm field of view, a voxel size of 0.085 mm, 90 kVp, and with MAR either enabled or disabled. Five oral and maxillofacial radiologists independently evaluated the CBCT exams under each MAR mode and across 3 sharpening filter conditions: no filter, Sharpen 1×, and Sharpen 2×. The diagnostic performance was quantified by the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. These metrics were compared using 2-way analysis of variance with a significance level of α=5%. Intra- and inter-examiner agreement were assessed using the weighted kappa test. Results: Neither MAR nor the application of sharpening filters significantly impacted AUC or specificity (P>0.05). However, sensitivity increased when MAR was combined with Sharpen 1× and Sharpen 2× (P=0.015). The intra-examiner agreement ranged from fair to substantial (0.34-0.66), while the inter-examiner agreement ranged from fair to moderate (0.27-0.41). Conclusion: MAR in conjunction with sharpening filters improved VRF detection; therefore, their combined use is recommended in cases of suspected VRF.