• Title/Summary/Keyword: VOCs analysis

Search Result 327, Processing Time 0.024 seconds

An analysis of indoor environment research trends in Korea using topic modeling : Case study on abstracts from the journal of the Korean society for indoor environment (토픽모델링을 활용한 실내환경 분야 연구동향 파악 : 실내환경학회지 초록 사례연구)

  • Jeon, Hyung Jin;Kim, Do Youn;Han, Kook Jin;Kim, Dong Woo;Son, Seung Woo;Lee, Cheol Min
    • Journal of odor and indoor environment
    • /
    • v.17 no.4
    • /
    • pp.322-329
    • /
    • 2018
  • The objective of this study is to identify the research trend in the field of indoor environment in Korea. We collected 419 papers published in the Journal of the Korean Society for indoor environment between 2004 and 2018, and attempted to produce datasets using a topic modeling technique, Latent Dirichlet Allocation(LDA). The result of topic modeling showed that 8 topics ("VOCs investigation", "Subway environment", "Building thermal environment", "School health", "Building particulate matter", "Asbestos risk", "Radon risk", "Air cleaner and treatment") could be extracted using Gibbs sampling method. In terms of topic trends, investigation of volatile organic compounds, subway environment, school health, and building particulate matter showed a decreasing tendency, while the building thermal environment, asbestos risk, radon risk, air cleaners, and air treatment showed an increasing tendency. The results of this topic modeling could help us to understand current trends related indoor environment, and provide valuable information in developing future research and policy frameworks.

Analysis of the Correlation between Urban High Temperature Phenomenon and Air Pollution during Summer in Daegu

  • An, Eun-Ji;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.28 no.10
    • /
    • pp.831-840
    • /
    • 2019
  • Recently, summer high temperature events caused by climate change and urban heat island phenomenon have become a serious social problem around the world. Urban areas have low albedo and huge heat storage, resulting in higher temperatures and longer lasting characteristics. To effectively consider the urban heat island measures, it is important to quantitatively grasp the impact of urban high temperatures on the society. Until now, the study of urban heat island phenomenon had been carried out focusing only on the effects of urban high temperature on human health (such as heat stroke and sleep disturbance). In this study, we focus on the effect of urban heat island phenomenon on air pollution. In particular, the relationship between high temperature phenomena in urban areas during summer and the concentration of photochemical oxidant is investigated. High concentrations of ozone during summer are confirmed to coincide with a day when the causative substances (NO2,VOCs) are high in urban areas during the early morning hours. Further, it is noted that the night urban heat island intensity is large.. Finally, although the concentration of other air pollutants has been decreasing in the long term, the concentration of photochemical oxidant gradually increases in Daegu.

Effects of exogenous enzymes from invertebrate gut-associated bacteria on volatile organic compound emissions and microbiota in an in vitro pig intestine continuous fermentation model

  • Jong-Hoon Kim;Ho-Yong Park;Kwang-Hee Son
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.48 no.2
    • /
    • pp.67-77
    • /
    • 2024
  • This study aims to assess the efficacies of exogenous enzymes, derived from invertebrate gut-associated microbes, as feed additives, in reducing volatile organic compound (VOC) emissions using an in vitro pig intestine continuous fermentation system. An in vitro continuous fermentation model was used to simulate a comparable bionic digestion system by co-reacting feed, enzymatic additives (arazyme, mannanase, and xylanase, derived from the gut bacteria of Nephila clavata, Eisenia fetida, and Moechotypa diphysis, respectively), and gastrointestinal microbes, followed by an analysis of their correlations. A significant correlation was observed between exogenous enzyme supplementation and reduced VOC emissions in the fecal phase of continuous fermentation (p < 0.05). The concentration of VOCs decreased by 3.75 and 2.75 ppm in the treatment group following arazyme and multi-enzyme supplementation, respectively, compared to that in the control group (7.83 ppm). In addition, supplementation with arazyme and multiple enzymes significantly affected the microbial composition of each fermentation phase (p < 0.05). In particular, Lactiplantibacillus pentosus and Pediococcus pentosaceus, which changed in abundance according to arazyme or multi-enzyme supplementation, exhibited a positive relationship with VOC emissions. These results suggest that exogenous enzymes derived from invertebrate gut-associated bacteria can be efficiently applied as feed additives, leading to a reduction in VOC emissions.

Establishment of analytical methods for HPHC list of mainstream cigarette smoke (담배 주류연 중 7개 그룹의 유해성분(HPHC) 분석법 확립 및 유효성 평가)

  • Park, Hyoung-Joon;Lee, Jin-Hee;Cho, So-Hyun;Heo, Seok;Yoon, Chang-yong;Baek, Sun-Young
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.385-397
    • /
    • 2015
  • Harmful and potentially harmful constituents (HPHCs) are chemical compounds in tobacco smoke that cause harm to smokers and non-smokers. This study established and validated methods for the analysis of HPHCs from mainstream cigarette smoke. The analyzed HPHCs were categorized into seven groups: aromatic amines, volatile organic compounds (VOCs), heavy metals, tobacco specific nitrosamines (TSNAs), benzo[a]pyrene (B[a]P), ammonia, and carbonyl compounds. The methods were validated by specificity, linearity, limit of detection (LOD), accuracy, precision, and recovery. These validated methods were then applied to the reference cigarettes (1R5F, 3R4F). The correlation coefficients (r2) for the calibration curves of the seven groups were over 0.995. The LODs showed values of 0.01-0.04 ng/cig cig for aromatic amines, 0.01-0.16 μg/cig for VOCs, 0.01-1.27 ng/cig for heavy metals, 0.06-0.28 ng/cig for TSNAs, 0.04 ng/cig for benzo[a]pyrene, 0.08 μg/cig for ammonia, and 0.78-1.77 μg/cig for carbonyl compounds. The precisions obtained from the intra and inter-day batches were less than 15%. The accuracy and the recovery range were less than 15% and 79.2-117.5%, respectively. The proposed methods can therefore be applied for determining HPHCs in tobacco mainstream smoke.

Emission Characteristics of VOC due to Major Industrial Activities in the Ban Wall Industrial Complex (안산시 반월공단을 중심으로 한 주요 배출시설의 업종 및 배출시설별 VOC의 배출특성)

  • Im, M.S.;Kim, K.H.;Choi, Y.J.;Jeon, E.C.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.3
    • /
    • pp.325-336
    • /
    • 2006
  • The presence of volatile organic compounds (VOC), produced and released from both anthropogenic and natural sources, can accelerate the degradation of air quality in the surrounding area. In this study, we investigated the emission concentrations of VOC based on a total of 115 sample analysis made from 47 companies (representing 17 types of industry) at the Ban Wall industrial complex (Jun. 2004 to Jan. 2005). Through a statistical analysis of these measurement data, we inspected the emission characteristics of VOC in relation with industrial type and processing unit. When these data were compared each other, toluene was found to record the highest value of 423 ppb followed by ethylbenzene (68.3 ppb), m, p-xylene (43.6 ppb), o-xylene (27.2 ppb), styrene (23.9 ppb), and benzene (16.4 pub). In addition, by converting these VOC concentration data into malodor intensity, we attempted to account for their distribution patterns in terms of relative contribution to the malodor formation. The results of odor intensity conversion generally indicated that the odor intensities of individual VOC do not exceed the degree of 1. When our VOC results were compared against other odorous compounds measured concurrently, the results were highly contrasting each other. Despite relative insignificance as odorous compounds, these VOCs are generally found ubiquitously and in abundant quantities in this strong source area.

A Study on the Comparative Analysis and Improvement of Indoor Environmental Factor in Green Building Rating Systems (국내외 친환경건축물 인증제도 실내 환경 관련 부문 비교분석 및 개선안 연구)

  • Joh Hahn
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.4 s.57
    • /
    • pp.21-28
    • /
    • 2006
  • To promote environmentally responsible architectural practice, many nations have established their own green building rating system. Among other criteria, recently the indoor environmental quality section has been paid great attention due to Sick Building Syndrome, as this believed to caused by polluted indoor environment. In this context, indoor environmental quality is one of very important sections of each green building rating system and closely related to the very happiness of building users. The goal of this research is to compare and analyze the indoor environmental sections of three green building rating systems, GBCC, LEED v2.1, and BREEAM Office 2005, and find a direction for the improvement of GBCC. First, the three rating systems are analyzed in general to compare the importance of indoor environmental factors in each system. Second, the indoor environmental factors are reclassified within related sub-categories for the comparable analysis. Finally, based upon the comparable analysis, directions for the improvement of GBCC are as follows: 1. GBCC's h4r Environment Section needs to clarify its VOCs criteria based upon types of finish materials. 2. Sound Environment Section's noise control criteria needs to be revised based upon types of building usages and application method. 3. An indoor lighting related section needs to be included in GBCC, as even though light is the one of the most important factors in indoor environment, it has not been included in GBCC yet. 4. The sub-section of Confortable Indoor Environment Section related to the resting space and the universal accessibility are not in accord with the goal of green building rating system. These items need to be dealt within general building codes. 5. The rating evaluation structure and process need to be streamlined.

Analysis of User Requirements Prioritization Using Text Mining : Focused on Online Game (텍스트마이닝을 활용한 사용자 요구사항 우선순위 도출 방법론 : 온라인 게임을 중심으로)

  • Jeong, Mi Yeon;Heo, Sun-Woo;Baek, Dong Hyun
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.43 no.3
    • /
    • pp.112-121
    • /
    • 2020
  • Recently, as the internet usage is increasing, accordingly generated text data is also increasing. Because this text data on the internet includes users' comments, the text data on the Internet can help you get users' opinion more efficiently and effectively. The topic of text mining has been actively studied recently, but it primarily focuses on either the content analysis or various improving techniques mostly for the performance of target mining algorithms. The objective of this study is to propose a novel method of analyzing the user's requirements by utilizing the text-mining technique. To complement the existing survey techniques, this study seeks to present priorities together with efficient extraction of customer requirements from the text data. This study seeks to identify users' requirements, derive the priorities of requirements, and identify the detailed causes of high-priority requirements. The implications of this study are as follows. First, this study tried to overcome the limitations of traditional investigations such as surveys and VOCs through text mining of online text data. Second, decision makers can derive users' requirements and prioritize without having to analyze numerous text data manually. Third, user priorities can be derived on a quantitative basis.

Temporal Variability of CH4 Gas Concentration Collected in Sampling Bag (온실가스 시료 보관시간에 따른 CH4 농도 변화)

  • Hong, Yoonjung;Cho, Changsang;Kang, Seongmin;Yun, Hyun-Ki;Jeon, Eui-Chan
    • Journal of Climate Change Research
    • /
    • v.7 no.4
    • /
    • pp.477-484
    • /
    • 2016
  • In general, $CH_4$ concentrations generated in combustion facilities are known to be ppm units. In most cases, $CH_4$ samples are collected in Tedlar bags and transported to laboratories for analysis. Considering this fact, in the present study, an attempt was made to find out how long samples can be stored in cases where they are kept in bags and transported as a preliminary study for sampling. According to the results of the experiment using simulated gases (1 ppm, 5 ppm, 10 ppm) in Tedlar bag, $CH_4$ was safe up to 240 hr which is the full time. In the case of simulated gases are containing 4 kind gases ($N_2$, $CO_2$, $CH_4$, and $N_2O$). Field samples (samples of obtained by collecting combustion facilities' exhaust gases) are known to contain highly reactive substances (for example NOx, SOx, and VOCs) and may affect each other. In the present study, one site sample was secured from each of a bituminous coal combustion facility and an LNG combustion facility and whether the concentrations of $CH_4$ gas would change over time (24 hr, 96 hr, 144 hr, 192 hr) was checked. Since site samples could not be analyzed on the day of collection, an experiment was started 24 hr after the time point of sampling to analyze the samples. As with the results of analysis of the simulated gas (240 hr), the results of analysis using the site sample indicated that it could be stored for the full study period 192 hr. Therefore, it was judged that if 192 hr would be taken after sampling before the sample would be analyzed, the concentration value should be reliable.

Evaluation of Efficiency of SVE from Lab-scale Model Tests and Numerical Analysis (실내모형시험과 수치해석을 통한 SVE의 효율성 평가)

  • Suk, Heejun;Seo, Min Woo;Ko, Kyung-Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.1B
    • /
    • pp.137-147
    • /
    • 2008
  • Soil Vapor Extraction (SVE) has been extensively used to remove volatile organic compounds (VOCs) from the vadoze zone. In order to investigate the removal mechanism during SVE operation, laboratory modeling experiments were carried out and tailing effect could be observed in later stage of the experiment. Tailing effect means that removal rate of contaminants gets significantly to decrease in later stage of SVE operation. Also, mathematical model simulating the tailing effect was used, which considers rate-limited diffusion in a water film during mass transfer among gas, liquid, and solid phases. Measurement data obtained through the experiment was used as input data of the numerical analyses. Sensitivity analysis was performed to examine the effect of each parameter on required time to reach final target concentration. Finally, it was found that the concentration in the soil phase decreased significantly with a liquid and gas diffusion coefficient larger, actual path length shorter, and water saturation smaller.

Distribution Characteristics of Environmental Contaminant at Soil in an Industrial Complex Area (공단지역 토양 중 환경오염물질 농도 분포 특성)

  • Jung, Jong-Hyeon;Cho, Sang-Won;Lim, Hyun-Sul
    • Clean Technology
    • /
    • v.18 no.2
    • /
    • pp.200-208
    • /
    • 2012
  • This study was performed to prevent the health damage of environmental contaminants in Industrial Complex Area. And, this study aimed to identify the concentration levels and distribution characteristics of environmental contaminants and Polycyclic Aromatic Hydrocarbons (PAHs) at soil in Industrial Complex Area and control area. The concentration of the soil pollution standard such as the heavy metals in the soil, VOCs, PAHs, and PCB were measured and analyzed using the soil specimens in the Industrial Complex Area and control area. Soil specimens from the Industrial Complex Area (the direct exposure area) and the control area were surveyed. Songdo-dong, Haedo-dong and Jechul-dong, which are in the direct exposure area and near the emission source, showed relatively high concentrations of contaminant materials when compared with Jangki-myeon, which is far off and in the control area. The concentration of zinc was 20.8-58.9% of the level of concern (300 mg/kg) in the 1st region, which is a relatively high concentration. The concentration of fluoride was under the standard in every region, but it was about 74% of the level of concern (400 mg/kg) in the 1st region. It is recommended that controlling fluoride emissions is necessary. Levels of organic phosphate, phenol, and VOCs like benzene, toluene, ethylbenzene and xylene were under the detection limit of the analysis instruments. The concentration of TPH was high in Songdo-dong. The concentration of contaminants in Jechul-dong was high. In addition, it was observed that the level of soil contamination changed depending on the distance from the emission source. The concentration of PAH compounds in the soil was 18.71-1744.59 ng/g, and the concentration of six potential cancer-causing PAH materials was 6.54-695.94 ng/g. The highest concentration was in Songdo-dong. The PAH concentration in the direct exposure area near the complex was relatively high compared to the indirect exposure area.