• 제목/요약/키워드: VOCs: Volatile Organic Compounds

검색결과 690건 처리시간 0.022초

휘발성 유기화합물 탐지용 다공성 실리콘 Microcavity 센서 (Porous Silicon Microcavity Sensors for the Detection of Volatile Organic Compounds)

  • 박철영
    • 통합자연과학논문집
    • /
    • 제2권3호
    • /
    • pp.211-214
    • /
    • 2009
  • A new porous silicon (PSi) microcavity sensor for the detection of volatile organic compounds (VOCs) was developed. PSi microcavity sensor exhibiting unique reflectivity was successfully obtained by an electrochemical etching of silicon wafer. When PSi was fabricated into a structure consisting of two high reflectivity muktilayer mirrors separated by an active layer, a microcavity was formed. This PSi microcavity is very sensitive structures. Reflection spectrum of PSi microcavity indicated that the full-width at half-maximum (FWHM) was of 10 nm and much narrower than that of fluorescent organic molecules or quantum dot. The detection of volatile organic compounds (VOCs) using PSi microcavity was achieved. When the vapor of VOCs condensed in the nanopores, the refractive indices of entire particle increased. When PSi microcavity was exposed to acetone, ether, and toluene, PSi microcavity in reflectivity was red shifted by 28 nm, 33 nm, and 20 nm for 2 sec, respectively.

  • PDF

국내 대기 중 독성 휘발성 유기화합물의 오염 특성(I) - 측정 방법론 평가 - (Characteristics of Atmospheric Concentrations of Toxic Volatile Organic Compounds in Korea ( I ) - Evaluation of Sampling and Analytical Methodology)

  • 백성옥;김미현;김수현;박상곤
    • Environmental Analysis Health and Toxicology
    • /
    • 제17권2호
    • /
    • pp.95-107
    • /
    • 2002
  • This study was designed to investigate the characteristics of atmospheric concentrations of toxic volatile organic compounds (VOCs) in Korea. Target compounds included 1,3-butadiene, aromatics such as BTEX, and a number of carbonyl compounds. In this paper, as the first part of the study, the performance of sampling and analytical methods was evaluated for the measurement of selected VOCs and carbonyl compounds in the ambient air. VOCs were determined by the adsorbent tube sampling and automatic thermal desorption coupled with GC/MSD analysis, while carbonyls by the DNPH-silica cartridge sampling with HPLC analysis. The methodology was investigated with a wide range of performance criteria such as repeatability, linearity. lower detection limits, collection efficiency, thermal conditioning, breakthrough volume and calibration methods using internal standards. In addition, the sampling and analytical methods established in this study were applied to real field samples duplicately collected in various ambient environments. Precisions for the duplicate samples appeared to be comparable with the performance criteria recommended by USEPA TO-17. The overall precision of the sampling and analytical methods was estimated to be within 20 ∼ 30% for major aromatic VOCs such as BTEX, whereas the precision for major carbonyl compounds such as formaldehyde and acetaldehyde was within 10 ∼ 20% for field samples. This study demonstrated that the adsorbent sampling and thermal desorption method can be reliably applied for the measurement of BTEX in ppb levels frequently occurred in common indoor and ambient environments.

고속도로 터널내부 공기 중 휘발성 유기화합물의 농도 측정 (Measurement of Volatile Organic Compounds Concentrations in the Air of a Highway Tunnel)

  • 백성옥;김영민;황승만
    • 한국대기환경학회지
    • /
    • 제14권1호
    • /
    • pp.73-77
    • /
    • 1998
  • In this study, a total of 10 volatile organic compounds (VOCs) including BTEX were determined in the inside and outside of a highway thnnel in order to evaluate the emission profile of automobile exhaust with respect to the concentrations, relative ratio and correlation coefficient of target analytes. In addition to VOCs, CO $CO_2 and NO_2$ were measured simultaneously. The results of this study indicated that the most abundant compound was toluene followed by benzene and m+p-xylenes, and the correlation coefficients between VOCs except styrene were higher than 0.96. The concentration ratio of toluene, ethylbenzene, xylenes with respect to benzene measured in the inside of tunnel was 1.5, 0.13, 0.74, respectively. Such ratios were found to be very similar to those measured in tunnels in the USA.

  • PDF

외국식물의 배치변화에 따른 폼알데하이드와 VOCs 농도저감에 관한 연구 (A Study on the Reduction of Formaldehyde and VOCs by Positions of Foreign Plants)

  • 송정은;김용식;손장열
    • KIEAE Journal
    • /
    • 제8권2호
    • /
    • pp.53-58
    • /
    • 2008
  • With architectural technology, a building has been a far dense and close. So the thermal environment of the building has become pleasant, but the quality of indoor air has been degraded. Using synthetic products for construction materials and furniture indoors escalates the concentration of volatile organic compounds(VOCs) at indoor air, threatening the health of the residents. To reduce the concentration of volatile organic compounds at indoor air, many methods are designed, and of late, concern has been increased about the effect of air purification using air purifying plants. Field measurements were performed using Aglaonema brevispathum, Pachira aquatica and Ficus benjamiana, which were verified as air-purifying plants by NASA. The effect of reducing the concentration of air contaminants by plant studied in a full scale mock-up model. The variations of concentration of Benzene, Toluene, Ethylbenzene and Formaldehyde were monitored. In most cases, the effect was excellent in Toluene and formaldehyde in summer.

Development of primary reference gas mixtures of 18 volatile organic compounds in hazardous air pollutants (5 nmol/mol level) and their analytical methods

  • Kang, Ji Hwan;Kim, Yong Doo;Lee, Jinhong;Lee, Sangil
    • 분석과학
    • /
    • 제34권5호
    • /
    • pp.202-211
    • /
    • 2021
  • Volatile organic compounds (VOCs) in hazardous air pollutants (HAPs) have been regulated by the Air Pollution Control Act (1978) and their atmospheric concentrations have been monitored in 39 monitor sites in Korea. However, measurement standards of volatile organic compounds (VOCs) in HAPs at ambient levels have not been established in Korea. Primary reference gas mixtures (measurement standards) at ambient levels are required for accurately monitoring atmospheric VOCs in HAPs and managing their emissions. In this study, primary reference gas mixtures (PRMs) at 5 nmol/mol were developed in order to establish primary national standards of VOCs in HAPs at ambient levels. Primary reference gas mixtures (PRMs) were prepared in pressurized aluminum cylinders with special internal surface treatment using gravimetric method. Analytical methods using gas chromatography-flame ionization detector (GC-FID) coupled with a cryogenic preconcentrator were also developed to verify the consistency of gravimetrically prepared HAP VOCs PRMs. Three different columns installed in the GC-FID were evaluated and compared for the retention times and separation of eighteen target components in a chromatogram. Results show that the HAP VOCs PRMs at 5 nmol/mol were consistent within a relative expanded uncertainty (k=2) of less than 3 % except acrylonitrile (less than 6 %) and the 18 VOCs were stable for 1 year within their associated uncertainties.

토양 흡착에 대한 유기탄소와 온도의 영향 (Influence of Organic Matter and Temperature on the Sorption of Volatile Organic Compounds on Soil)

  • 김희경
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 1998년도 공동 심포지엄 및 추계학술발표회
    • /
    • pp.57-59
    • /
    • 1998
  • The headspace method has been acknowledged as a cost-effective and convenient method to analyze volatile organic compounds(VOCs) in soil. The headspace analysis is based on equilibrium partitioning of VOCs among water, air and soil in a closed system. However, the headspace method cannot be applied to soils where most of the VOCs remain sorbed even at high temperature. In this study, it was investigated how the sorption characteristics of VOCs varied with soil with different organic carbon contents and temperature. This study showed that all the VOCs were volatilized, not sorved, only in the soil with 5% organic carbon at 45$^{\circ}C$ or higher. Some fraction of VOCs remained in soil with 8% organic carbon at $65^{\circ}C$ of higher. Most of the VOCs remained sorbed in soil with 12% organic content even at 95$^{\circ}C$. This result suggested that the headspace method can be applied only to soils with little organic carbon content (less than 5%). In this case, 45$^{\circ}C$ seems to be high enough to volatilize all the VOCs from soil. Large particles still showed a significant sorption capacity for VOCs from soil. Large Particles still showed a significant sorption capacity for VOCs despite of their low level of organic carbon content. It was also shown that the organic carbon sorption coefficients (Koc) of VOCs varied with soils with different organic carbon content. This suggests that not only the organic matter content of soil but also the property of the organic matter in soil influence the sorption of VOCs to soil.

  • PDF

Characteristics of Volatile Organic Compounds from Newly Produced Building - Apartment House

  • Lee, Jeong-Joo;Kim, Jeong-Ho;Kim, Shin-Do
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2004년도 International Conference Global Environmental Problems and their Health Consequences
    • /
    • pp.223-226
    • /
    • 2004
  • Building materials emit high concentration volatile organic compounds(VOCs), formaldehyde(HCHO) and other hazardous air pollutants(HAPs) to indoor environment. Average value of VOCs and HCHO emission concentration were $3,770\;{\mu}g/m^3$, $430\;{\mu}g/m^3$ in newly buildings, respectively. VOCs and HCHO emission characteristic are high emission level at initial time and decreased in course of time.

  • PDF

하수관거 및 토구에서 발생하는 휘발성 유기화합물 악취 특성 (Odor Characteristics and Concentration of Malodorous Volatile Organic Compounds Emitted from a Sewer and Its Outlet)

  • 박상진;권수열
    • 한국환경보건학회지
    • /
    • 제43권6호
    • /
    • pp.457-466
    • /
    • 2017
  • Objectives: This study was carried out to investigate the characteristics of volatile organic compounds (VOCs) emitted from sewerage facilities such as a sanitary sewers, outlets, and catch basins. In addition, the dominant malodorous VOCs among the compounds in this study were studied. Methods: Waste gas samples were collected at 27 points in a sanitary sewer in commercial and residental areas. The concentrations of seven volatile organic compounds, including benzene and toluene, in the samples were analyzed by gas chromatograph mass spectrophotometer (GC/MS). Odor concentrations were estimated using the concentration data of the VOCs and each compound's threshold limit value. Results: As a result, it appeared that the average concentration of total observed data for acetaldehyde was 15.98 ppb and benzene 1.87 ppb, toluene 82.31 ppb, ethyl benzene 63.12 ppb, m+p-xylene 15.66 ppb, oxylene 18.73 ppb, and styrene 4.39 ppb. VOC concentrations in the commercial area were higher than those in the residential area. VOC concentrations of waste gas emitted from sewer lines was also higher than those at the outlet and in the catch basins. It was estimated that the main malodorous VOC among the seven VOCs was acetaldehyde. Conclusions: As there is little data on VOC concentrations inside sewer facilities in Korea, these data will be helpful for estimating impact assessment of VOCs and establishing a counter-plan for the abatement of VOCs from sewer facilities in the future.

휘발성 유기물질의 고효율 열산화 시스템 개발 연구 (Study on the Development of Recuperative Thermal Oxidation System for the Volatile Organic Compounds)

  • 현주수;이시훈;이종섭;민병무
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제29회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.225-230
    • /
    • 2004
  • Volatile organic compounds (VOCs) are low calorific value gases (LCVG) emitted from chemical processes such as painting booth, dye works and drying processes etc. Characteristics of VOCs are low calorific values less than 150 kcal/$m^3$, high activation energy for ignition and low energy output. These characteristics usually make combustion unstable and its treatment processes needs high-energy consumption, The cyclone combustion system is suitable for LCVG burning because it can recirculate energy through a high swirling flow to supply the activation energy for ignition, increases energy density to make a combustion temperature higher than usual swirl combustor and also increases mixing intensity, This research was conducted to develop optimized cyclone combustion system for thermal oxidation of VOCs. This research was executed to establish the effect of swirl number with respect to the combustion temperature and composition of exhausted gas in the specific combustor design.

  • PDF

휘발성 유기 화합물(VOCs) 처리 기술 (Technologies for Volatile Organic Compounds(VOCs) Treatment)

  • 서봉국;나영수;송승구
    • 한국환경과학회지
    • /
    • 제12권7호
    • /
    • pp.825-833
    • /
    • 2003
  • The emission of volatile organic compounds (VOCs) generated from painting and coating processes is a worldwide problem as contributing factors to the development of photochemical smog and other environmental problems. Common methods of reducing VOC emissions are adsorption on activated carbon, membrane separation, absorption, incineration, or catalytic oxidation. In this article, the environmental issues caused by VOC emissions and the trend of legislation against such emissions will be surveyed first. Several conventional control technologies will then be summarized and the characteristics of each process will be introduced. Lastly, some examples will be described to show the hybrid processes which have been industrially applied for the recovery of VOC.