• 제목/요약/키워드: VOC treatment

검색결과 110건 처리시간 0.024초

VOC 처리를 위한 Biofilter 개발 원리 및 상업화 (Principle and Commercialization of Biofilter for Treatment of Volatile Organic Compounds)

  • 이은열;황재웅;강염석;문철연;박성훈
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2004년도 학술대회지
    • /
    • pp.85-106
    • /
    • 2004
  • Styrene as volatile organic compounds(VOC) has come under strict regulatory control as they cause serious health and environmental problems. Biofiltration offers a number of economical and environmental advantages over conventional technologies, such as incineration, catalytic adsorption, and chemical scrubbing. In this presentation, recent progresses on the development of lab-scale biofilter for the treatment of gas-phase styrene are reviewed, The potentials of commercialization of biofilter systems are also discussed.

  • PDF

이단미생물반응조에서 혼합 VOCs의 생분해 특성 (Biological Removal of a VOC Mixture in a Two-stage Bioreactor)

  • 송지현
    • 한국대기환경학회지
    • /
    • 제22권6호
    • /
    • pp.758-766
    • /
    • 2006
  • A two-stage bioreactor, which consists of a biotrickling filter module and a biofilter module in series, was investigated for the enhanced treatment of a VOC mixture, toluene and methyl ethyl ketone (MEK). Throughout the experiments, the overall inlet loading rate was maintained at approximately $43g/m^3/hr$, but the inlet ratios of the VOCs were modified. The experimental results showed that the different ratios of the VOC mixture resulted in changes of overall removal efficiencies, elimination capacities (ECs) and microbial accumulation on the surface of each packing material. The ratio of inlet toluene to MEK at 50 : 150 was found to be most effective in terms of the overall removal efficiency, because, at this condition, MEK (i.e., the hydrophilic compound) was mostly removed in the biotrickling filter module and the following biofilter module was used to remove toluene. It was also found that when the inlet loading rate of the VOC mixture was serially increased stepwise within short-term periods, the ECs for toluene dropped significantly but the ECs for MEK increased at the ratio of the VOC mixture. These results implied that substrate interaction and/or substrate preferable utilization might have an effect on the biological removal of each compound in the two-stage bioreactor; therefore, the bioreactor should be operated in the condition where the substrate interaction could be minimized in order to maximize overall performance of the two-stage bioreactor.

유류오염토양으로부터 발생하는 VOC가스처리를 위한 바이오스크러버 개발 (Development of a Bioscrubber for Treatment of VOC Emissions from Contaminated Soil with Hydrocarbons)

  • 장윤영;황경엽;곽재호;최대기
    • 한국토양환경학회지
    • /
    • 제2권1호
    • /
    • pp.83-90
    • /
    • 1997
  • 저농도의 난 수용성 VOC가스가 포함되어 있는 다량의 오염가스를 처리하기 위하여 흡수탑과 생물반응기의 결합체인 새로운 처리시스템을 제시하였다. 바이오스크러버의 스크러버에서는 세정액으로 기상중의 처리대상오염물질의 흡수가 일어나며 세정액은 생물반응기로 이송되어 호기성 미생물이 오염물을 분해시킨다. 본 연구에서는 폐가스중의 VOC분리를 위하여 재순환가능한 고비점용매를 사용하였다. 고비점용매를 포함한 세정액은 기/액 향류접촉이 이루어지는 흡수탑의 충전층에서 폐가스중의 오염물을 분리한다. 흡수탑은 Pall ring충전제로 채워 실제공정을 모사 하고자 하였다. 흡수처리후 생물반응기로 이송된 흡수액은 재생 후 다시 흡수탑으로 재 순환하였다. 실험에 사용된 대상가스는 농도가 400 mg/$\textrm{m}^3$ 인 톨루엔으로, 세정액이 가스흐름과 향류로 약 10~15L/min의 유량으로 충전층을 적시며 내려오는 충전탑내부로 약 100 L/min의 유량으로 도입하였다. VOC처리를 위해 제작된 본 바이오스크러버에서 고비점용매를 이용한 연속실험결과 최적운전 조건에서 약 80%의 처리율을 얻을 수 있었다.

  • PDF

낙동강 유역 일부 폐수처리장 방류수 및 공단배수로의 휘발성유기화합물(VOCs)의 분포현황 (The Detection of VOCs in Effluents from Several Wastewater Treatment Plants and Industry Drains in Nakdong River Basin)

  • 배헌균
    • 대한환경공학회지
    • /
    • 제34권4호
    • /
    • pp.254-259
    • /
    • 2012
  • 낙동강 유역 일부공단지역에 위치한 일곱 개소의 폐수처리장 및 두 개소의 공단배수로에서 휘발성유기화합물(Volatile Organic Compounds, VOCs)의 분포특성을 조사하였다. 시료는 2008년 5월부터 2008년 11월 사이 총 4회에 걸쳐 채취하였으며 총 17종의 VOCs를 분석하였다. 실험 결과, 8종의 VOCs가 일부 시료에서 검출이 되었고 검출농도는 종류와 시료채취 위치에 따라 달랐지만 모두 0.11 (Trichloroethylene)~5.81 (Toluene) ${\mu}g/L$ 의 범위인 것으로 확인되었다. VOCs는 미량으로도 인간의 건강이나 수중 생태계에 심각한 영향을 미칠 수 있으므로 이들 물질이 비록 미량의 수준을 보였으나 검출이 된 이상 이들 물질에 대한 적절한 관리대책이 강구되어야 할 것으로 사료되며 본 연구에서 이들 물질에 대한 관리방안을 제안하였다.

낙동강 상수원수의 오존처리 효과 - II. 회분식 오존처리에 의한 휘발성유기화합물 및 조류제거 효과 - (Effect of Ozone Treatment for Nakdong River Raw Water - II. Removal of VOCs and Algae in Raw Water by Conducting Batch Test of Ozonation Experiments -)

  • 임영성;이홍재;이도진;허종수;손보균;조주식
    • 한국환경과학회지
    • /
    • 제11권12호
    • /
    • pp.1267-1274
    • /
    • 2002
  • This study was carried out to evaluate the pollutant removal efficiencies of the advanced drinking water treatment using ozonation process. For raw water, Nakdong River was used. By conducting batch test of ozonation, the following results were obtained. When ozone dosage of $5 mg/{\ell}$ was used, ozone transfer and utilization efficiencies of the ozonation were 94 to 92%, respectively. Removal efficiencies of single VOC compound or mixed VOC compounds in the raw water were 80% to 90% by the ozonation with $2 mg/{\ell}$ dosage and 10 minutes contact time. Removal efficiencies of ABS by the ozonation with $1 mg/{\ell}$, $3 mg/{\ell}$ dosage and 20 minutes contact time were 83% to 96%, respectively. Almost 67% of chlorophyll-a at the concentration of $38.4\mu\textrm{g}/{\ell}$ was removed by ozonation at ozone dosage of $1 mg/{\ell}$ for 20 min. Considering the efficiency of ozone utilization and water treatment, the most effective ozonation could be obtained with high ozone dosage and short contact time.

진주시 대기중 휘발성 유기화합물의 농도특성 기초조사 (Characterization of Volatile Organic Compounds(VOCs) Concentrations in Jinju)

  • 박정호;박현건;서정민
    • 한국환경과학회지
    • /
    • 제22권1호
    • /
    • pp.91-98
    • /
    • 2013
  • In order to study the seasonal patterns and possible origins of air concentrations of volatile organic compounds(VOC), measurements were taken with GC-MS at 3 sampling sites in Jinju for 12 months from Mar. 2010 to Feb. 2011. Atmospheric VOC are sampled on tubes containing solid adsorbents(Tenax TA) with a time resolution of 2hrs. Composition and concentration of VOC are analysed with a GC system equipped with thermal desorption apparatus(ATD). The most abundant compound appeared to be Toluene, Ethylbenzene and m,p-Xylene. The mean concentrations of Benzene were 0.20 ppb at GN site, 0.18 ppb at DA site, and 0.25 ppb at SP site, respectively. VOC concentration showed a strong seasonal variation, with higher concentrations during the spring and lower concentrations during the summer. The results showed that monthly fluctuations in measured VOC concentrations depended on variations in the strength of sources, as well as on photochemical activity and meteorological conditions. In Jinju, the total VOC emissions for 2009 were estimated to be 4,407 ton/year by Clean Air Policy Support System(CAPSS). It is shown that solvent use 57.5%(2,534 ton/yr), waste treatment and disposal 23.3%(1,025 ton/yr), and mobil source-road traffic 12.2%(537 ton/yr) are the most significant anthropogenic source.

전극의 부반응 기포발생에 따른 휘발특성과 전기화학고도산화능을 동시에 고려한 휘발성 유기화합물 처리용 최적 불용성전극 개발 (Optimum dimensionally stable anode with volatilization and electrochemical advanced oxidation for volatile organic compounds treatment)

  • 조완철;부경민;이지은;김태남;채규정
    • 상하수도학회지
    • /
    • 제33권1호
    • /
    • pp.31-41
    • /
    • 2019
  • Volatile organic compounds(VOCs) are toxic carcinogenic compounds found in wastewater. VOCs require rapid removal because they are easily volatilized during wastewater treatment. Electrochemical advanced oxidation processes(EAOPs) are considered efficient for VOC removal, based on their fast and versatile anodic electrochemical oxidation of pollutants. Many studies have reported the efficiency of removal of various types of pollutants using different anodes, but few studies have examined volatilization of VOCs during EAOPs. This study examined the removal efficiency for VOCs (chloroform, benzene, trichloroethylene and toluene) by oxidization and volatilization under a static stirred, aerated condition and an EAOP to compare the volatility of each compound. The removal efficiency of the optimum anode was determined by comparing the smallest volatilization ratio and the largest oxidization ratio for four different dimensionally stable anodes(DSA): Pt/Ti, $IrO_2/Ti$, $IrO_2/Ti$, and $IrO_2-Ru-Pd/Ti$. EAOP was operated under same current density ($25mA/cm^2$) and electrolyte concentration (0.05 M, as NaCl). The high volatility of the VOCs resulted in removal of more than 90% within 30 min under aerated conditions. For EAOP, the $IrO_2-Ru/Ti$ anode exhibited the highest VOC removal efficiency, at over 98% in 1 h, and the lowest VOC volatilization (less than 5%). Chloroform was the most recalcitrant VOC due to its high volatility and chemical stability, but it was oxidized 99.2% by $IrO_2-Ru/Ti$, 90.2% by $IrO_2-Ru-Pd/Ti$, 78% by $IrO_2/Ti$, and 75.4% by Pt/Ti anodes The oxidation and volatilization ratios of the VOCs indicate that the $IrO_2-Ru/Ti$ anode has superior electrochemical properties for VOC treatment due to its rapid oxidation process and its prevention of bubbling and volatilization of VOCs.

담체변화에 따른 Labscale 바이오필터의 성능 실험 (Operation of Biofilters with Different Packing Material - development of media and biological parameters for optimal odor treatment process in a biofilter)

  • Daechul Cho;Sung Hyun Kwon
    • 한국산학기술학회논문지
    • /
    • 제4권3호
    • /
    • pp.236-241
    • /
    • 2003
  • 산업체 발생 VOC를 효과적으로 처리하는 Biofilter 시스템을 고안하였다. 재질과 다공성이 다른 3기의 시스템으로부터 황화수소, 벤젠, 톨루엔, 크실렌의 단일성분과 복합성분계의 성능을 고찰하였다 저 pH Biofilter(pH 2-3)의 장기운전이 가능하였고 벤젠의 경우 경쟁적 저해를 나타내었으나 일정기간의 순응 이후 혼합처리시 양호한 처리능력을 보여주었다.

  • PDF

광촉매를 이용한 휘발성유기화합물의 처리장치 (A Photocatalytic Treatment equipment of Volatile Organic Compounds)

  • 유재흥;김태관;유진승;김광;김혜경;박윤창;이승호
    • 환경기술인
    • /
    • 통권176호
    • /
    • pp.58-63
    • /
    • 2001
  • 여러 환경정화 방법들 중 광촉매를 이용한 처리기술들이 관심을 모으고 있다. 광에 의해 활성을 갖는 여러 촉매들 가운데 이산화티타늄($TiO_2$)을 중심으로 한 연구가 가장 활발히 진행되고 있다. 본 연구는 TiO2를 개질화하여 광활성이 우수한 광촉매를 개발하고 이를 이용한 VOC 처리를 목적으로 하고 있다. VOC 중 할로겐화(halogenated)된 것들의 처리는 매우 어려우며 현재의 소각방식으로는 효과적으로 처리되고 있지 않다.

  • PDF