• Title/Summary/Keyword: VOC emission

Search Result 195, Processing Time 0.02 seconds

Development of the vac Source Profile using Collinearity Test in the Yeosu Petrochemical Complex (여수석유화학산단의 공선성 시험을 이용한 VOC 오염원 분류표 개발)

  • Jeon Jun-Min;Hur Dang;Hwang In Jo;Kim Dong-Sul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.3
    • /
    • pp.315-327
    • /
    • 2005
  • The total of 35 target VOCs (volatile organic compounds), which were included in the TO-14, was selected to develop a VOCs' source profile matrix of the Yeosu Petrochemical Complex and to test its collinearity by singular value decomposition(SVD) technique. The VOCs collected in canisters were sampled from 12 different sources such as 8 direct emission sources (refinery, painting, wastewater treatment plant, incinerator, petrochemical processing, oil storage, fertilizer plant, and iron mill) and 4 general area sources (gasoline vapor emission, graphic art activity, vehicle emission, and asphalt paving activity) in this study area, and then those samples were analyzed by GC/MS. Initially the resulting raw data for each profile were scaled and normalized through several data treatment steps, and then specific VOCs showing major weight fractions were intensively reviewed and compared by introducing many other related studies. Next, all of the source profiles were tested in terms of degree of collinearity by SVD technique. The study finally could provide a proper VOCs' source profile in the study area, which can give opportunities to apply various receptor models properly including chemical mass balance (CMB).

A prediction of indoor pollutant concentration using method mass transfer coefficient in multi-layered building materials (복합 건축자재의 물질전달계수를 이용한 실내 오염물질 농도 예측방법)

  • Kim, Chang Nam;Lee, Yun Gyu;Leigh, Seung Bok;Kim, Tae Yeon
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.53-58
    • /
    • 2007
  • In order to predict the indoor air pollutant, the VOCs emission rate is used through small chamber in the design process. However, the small chamber method has limitations as the convective mass transfer coefficient, the most important factor when predicting VOCs contamination of indoor air, is different between the small chamber result and the measured data in the actual building. Furthermore, the existing studies which analyzed mass transfer coefficient in the small chamber were directed on the small chambers developed at the time and FLEC(Field and Laboratory Emission Cell), thus, are different from the current small chamber which has been changed with improvements. The purpose of this study is to determine the emission rate of pollutant in multi-layered building materials, and predict the indoor pollutant concentration through the CFD(Computational of Fluid Dynamics) and CRIAQ2 based on the mass transfer coefficient on singled-layered building material by using the current small chamber widely used in Korea. Futhermore, this study used the new convective mass transfer coefficient(hm') which indicates the existing convective mass transfer coefficient(hm) including VOC partition coefficient(k). Also, formaldehyde was selected as target pollutant.

Estimating Influence of Local and Neighborhood Emissions on Ozone Concentrations over the Kwang-Yang Bay based on Air Quality Simulations for a 2010 June Episode (대기질 모사를 통한 인접지역 배출량이 광양만 오존농도에 미치는 영향분석 - 2010년 6월 사례를 중심으로)

  • Kim, Soon-Tae;Lee, Chong-Bum
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.504-522
    • /
    • 2011
  • Simulations of CMAQ with the High-order Decoupled Direct Method (HDDM) for a 2010 June episode are applied to estimate the influence of local and neighborhood emissions on ozone concentrations in the Kwang-Yang Bay (KYB) area. In order to examine ozone response to reductions in $NO_x$ and VOC emissions from KYB and Gyeongsang, ozone isopleths are generated with the first and second-order sensitivity coefficients from HDDM simulations at three sites; Taein, Samil, and Gwangmoo. Simulations show that reduction in KYB $NO_x$ may increase ozone over the sites. On the contrary, $NO_x$ reduction from Gyeongsang may decrease ozone at the sites when transport of ozone and its precursors from upwind Gyeongsang is potentially high. However, VOC reductions from KYB and Gyeongsang are favorable to lower ozone over KYB. The study implies that emission reductions for both local and neighboring areas are likely more effective to bring KYB to ozone attainment.

The Development of VOC Measurement System Uging PCA & ANN (PCA와 ANN을 이용한 VOC 측정기기 개발)

  • Lee Jang-Hoon;Kwon Hyuk-Ku;Park Seung Ho;Kim Dong-Jin;Hong Chol-Ho
    • Environmental Analysis Health and Toxicology
    • /
    • v.19 no.2
    • /
    • pp.161-167
    • /
    • 2004
  • Air quality monitoring is a primary activity for industrial and social environment. The government identifies the pollutants that each industry must monitor. Especially, the VOCs (Volatile Organic Compounds), which are very harmful to human body and environment atmosphere, should be controlled under the government policy. However, the VOCs, which have not been confirmed in emission sources are very difficult to monitor. It is needed to develop the monitoring system that allow the continuous and in situ measurement of VOCs mixture in different environmental matrices. Gas chromatography and mass spectrometry are the most prevalent current techniques among those available for the analysis of VOCs. But, they need a large size analytical instrument, which costs a great deal for purchase and operation. In addition, it has some limitations for realtime environmental monitoring such as location problems and slow processing time. Recently, several companies have commercialized a portable VOCs measurement systems, which cannot classify various kinds of VOCs but total quantities. We have developed a VOCs measurement system, which recognizes various kinds and quantities of VOCs, such as benzene, toluene, and xylene (BTX). Also, it can be used as a stand- alone type and/or fixed type in the vehicle with rack for real -time environmental monitoring.

A Study of Emission Volume of Air Pollutants in Suwon City (수원시 대기오염발생량 조사에 관한 연구 -자동차에 의한 발생 중심으로-)

  • Cho, Ki-Chul;Whang, Kyung-Chul
    • Journal of Environmental Science International
    • /
    • v.19 no.3
    • /
    • pp.313-321
    • /
    • 2010
  • This study was carried out to investigate the emissions of the air pollutants from the automobile in Suwon city. To estimate emissions due to by automobile the data of express highway and the national road used an observation traffic volume, and the other roads used a method by Vehicle kilometer traveled(VKT). In the emissions due to by automobile from Suwon city, CO was highest 36,290.4 ton/year, NOx at 19,392.1 tons, HC 5,095.4 tons and PM 2,788.7 tons was highly order. SOx emissions in the whole Suwon city by fuel types was investigated with 178ton/year from the Diesel motorcar, 26.9 ton/year and 6.2 ton/year from the gasolines and LPG automobiles, respectively. VOC emissions from the automobile was investigated with 366.4 ton/year (29.22%) from Gwonseon-gu, 329.2 ton/year (26.25%) Yeongtong-gu, 319.9 ton/year (25.51%) Jangan-gu, 238.6 ton/year (19.03%) Paldal-gu.

Analysis of VOCs Produced from Incineration of Plastic Wastes Using a Small- Electric Furnace (소형전기로를 이용한 플라스틱류 소각시 발생하는 VOCs 농도분석)

  • Lee Byeong-Kyu;Kim Haengah
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.6
    • /
    • pp.759-771
    • /
    • 2004
  • This study analyzed concentrations of volatile organic compounds (VOCs) produced from incineration of plastic wastes at $600^{\circ}C$. The plastic wastes used in this study included polyethyleneterephthlate (PETE), high density polyethylene (HOPE), polyvinyl chloride (PVC), low density polyethylene (LOPE), polypropylene (PP), polystyrene (PS) and other. Plastic wastes were heated from room temperature upto $600^{\circ}C$ providing the compressed air inside of a small-scale electric furnace for 90 minutes and then they were oxidized (incinerated) for 60 minutes at $600^{\circ}C$ maintaining the same air supply. VOCs emitted from the incineration process were sampled using an air sampling pump and Tedlar air bags for 150 minutes and then the components and concentrations of the VOCs were analyzed by a GC-MS. The most prominent chemical structure of the VOCs obtained from the incineration process of the HOPE, LOPE and PP, which include ethylene groups in their main chains, was identified as aliphatic hydrocarbons such as 1-hexene. However, aromatics such as benzene were major chemical structure from the incineration of PETE, PVC and PS which include benzene rings in their main chains. This study estimated the total VOC production from the incineration of the plastic wastes based on the real plastic waste production and the emission factors. 64% and 27% of the total VOC emissions consisted of aliphatic hydrocarbons and aromatics, respectively, which have double bonds within their molecular structure and thus a high ground level ozone formation potential.

The Determination of Diffusion and Partition Coefficients of Indoor Bottom Finishing Materials (바닥재의 확산계수 및 분배계수 산정)

  • Park, Jin-Soo;Little, John C.;Kim, Shin-Do;Yun, Joong-Seop
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.3
    • /
    • pp.219-225
    • /
    • 2008
  • Many building materials may contain high concentrations of volatile organic compounds (VOCs) and other hazardous pollutants(HAPs). Specifically, VOCs discharged by indoor building material may cause "new house" syndrome, atopic dermatitis etc. The diffusion coefficient and initially contained total VOC quantity were determined using microbalance experiments and small chamber tests. Interactions between volatile organic compounds (VOCs) and vinyl flooring (VF), a relatively homogenous, diffusion-controlled building material, were characterized. Rapid determination of the material/air partition coefficient (K) and the material-phase diffusion coefficient (D) for each VOC was achieved by placing thin VF slabs in a dynamic microbalance and subjecting them to controlled sorption/desorption cycles. K and D are shown to be independent of concentration for all of the VOCs and water vapor. This approach can be applied to other diffusion-controlled materials and should facilitate the prediction of their source/sink behavior using physically-based models.

The synthesis and the structural analysis of advanced PVC plasticizer, 2,2,4-trimethyl-1,3-pentanediol-1-butyrate-3-isobutyrate

  • Cho Myo-Kyung;Ko Dong-Hyun;Lim Young-Hee;Jung Min-Hwan;Cho Hye-Sung;Ok Jong-Hoa
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.9 no.2
    • /
    • pp.103-109
    • /
    • 2005
  • New PVC plasticizer, 2,2,4-trimethyl-1,3-pentanediol-1-butyrate-3-isobutyrate was synthesized via simple esterification with butyric acid and Texanol(a trademark of Eastman Chemicals), the mixture of 2,2,4-trimethyl-1,3-pentanediol-3-isobutyrate and 2,2,4-trimethyl-1,3-pentanediol-1-isobutyrate. The analysis of $^1H-1D,\;^{13}C-1D$ NMR and HMBC spectra identified internal-ester-transfer of 2,2,4-trimethyl-1,3-pentanediol-1-isobutyrate during the reaction. 2,2,4-trimethyl-1,3-pentanediol-1-butyrate-3-isobutyrate gave better properties in PVC than 2,2,4-trimethyl-1,3-pentanediol diisobutyrate(TXIB, a trademark of Eastman Chemicals) such as lower viscosity, higher tensile strength and better elongation. In particular, remarkably reduced migration compared with TXIB suggested a reduced emission of VOC(volatile organic compound) from PVC.

  • PDF

Analysis of Volatile Organic Compounds Emitted from Electronic Parts in PC/Monitor Set (PC/Monitor 구성 전자부품에서 방출되는 휘발성 유기화합물의 분석)

  • Ri, Chang Seop;Choe, Jong Woo;Baek, Kyu Won
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.4
    • /
    • pp.343-349
    • /
    • 2000
  • Volatile Organic Compounds(VOCs) emitted form electronicSince toluene, xylene, cyclohexanone, and benzofuran will bring on the deleterious smell and the health risk, eventhough very small amount of these areexposed to human body, quantitative analysis was achieved by GC-MS system. As a result of these analyses, except PCB(CEM-1) of which is one of the electronic parts, the left of electronic parts represented, imme-diately form 30 minutes to 1 hour after heating, the trends that toluene, xylene, cyclohexanone and phenol were consecuticely emitted very high. and toluene, xylene, phenol, cyclohexanone, and benzofuran from most of the electronic parts were emitted very frequently within the measuring period. Finally, Trans of electronic parts showed the highest concentration of emission, and xylene(550~2482 ${\mu}g/m^2$) was the most noticeably emitting compound of VOCs.

  • PDF

Characteristics of Volatile Organic Compounds Emitted from Wood-based Panels (목질제품에서 방출되는 휘발성 유기화합물 특성 연구)

  • Park, Hyun-Ju;Son, Youn-Suk;Lim, Bo-A;Kim, Jo-Chun;Park, Sang-Bum
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.6
    • /
    • pp.616-623
    • /
    • 2010
  • Recently, interests in indoor air quality (IAQ) have been increased; however, a number of researchers have mainly focused on anthropogenic volatile organic compounds (AVOC) emitted from building materials. Therefore, the properties of natural VOC (NVOC) and anthropogenic VOC (AVOC) emitted from wood-based panels was investigated in this work. VOCs emitted from these panels were sampled through Tenax TA/Cabotrap and analyzed by GC-MS and GC-FID. Comparisons were made concerning TVOC, NVOC, and composition ratios of NVOC. It was revealed that TVOC emission rates of midium density fiber (MDF) were the highest. Besides, it was found that emissions of NVOC from wood-based panels were much higher than those of anthropogenic AVOC except for plywood of Oceania timber. It was also observed that the composition ratio of NVOC emitted from plywood of Pinus radiata was the highest as 65% of TVOC. Major NVOC components were monoterpene compounds such as $\alpha$-pinene, $\beta$-pinene, d-limonene, camphene and $\alpha$-terpinene. It was concluded that the composition rates of VOCs emitted from building materials were clearly different according to the raw materials and manufacturing methods.