• Title/Summary/Keyword: VITA Enamic

Search Result 23, Processing Time 0.024 seconds

Shear bond strengths of aged and non-aged CAD/CAM materials after different surface treatments

  • Kilinc, Hamiyet;Sanal, Fatma Ayse;Turgut, Sedanur
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.5
    • /
    • pp.273-282
    • /
    • 2020
  • PURPOSE. To assess shear bond strengths (SBS) of resin composites on aged and non-aged prosthetic materials with various surface treatments. MATERIALS AND METHODS. Cerasmart (CE), Vita Enamic (VE), Vita Mark II (VM), and IPS e.max CAD (EC) blocks were sliced, and rectangular-shaped specimens (14 × 12 × 1.5 mm; N = 352) were obtained. Half of the specimens were aged (5000 thermal cycles) for each material. Non-aged and aged specimens were divided into 4 groups according to the surface treatments (control, air abrasion, etching, and laser irradiation; n = 11) and processed for scanning electron microscopy (SEM). The repair procedure was performed after the surface treatments. SBS values and failure types were determined. Obtained data were statistically analyzed (P≤.05). RESULTS. The material type, surface treatment type, and their interactions were found significant with regard to SBS (P<.001). Aging also had a significant effect on prosthetic material-resin composite bonding (P<.001). SBS values of non-aged specimens ranged from 12.16 to 17.91 MPa, while SBS values of aged specimens ranged from 9.46 to 15.61 MPa. Non-aged VM in combination with acid etching presented the highest score while the control group of aged CE showed the lowest. CONCLUSION. Etching was more effective in achieving durable SBS for VM and EC. Laser irradiation could be considered as an alternative surface treatment method to air abrasion for all tested materials. Aging had significant effect on SBS values generated between tested materials and resin composite.

Influence of toothbrush abrasion and surface treatments on the color and translucency of resin infiltrated hybrid ceramics

  • Labban, Nawaf;Al Amri, Mohammad;Alhijji, Saleh;Alnafaiy, Sarah;Alfouzan, Afnan;Iskandar, Mounir;Feitosa, Sabrina
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.1-11
    • /
    • 2021
  • PURPOSE. The study compared the color change, lightness, and translucency of hybrid resin ceramics exposed to toothbrush abrasion and surface treatment. MATERIALS AND METHODS. Four hybrid ceramics [Lava Ultimate (LU), Vita Enamic (EN), Shofu HC (SH), and Crystal Ultra (CU)] were compared with a glass-ceramic (Vita Mark II) control. One hundred and twenty specimen blocks were prepared using a precision saw machine. Specimens in each material were divided into four subgroups based on the surface treatment (polishing or staining) and a storage medium (water or citric acid). Simulated tooth brushing with a mixture of 100 RDA (radioactive abrasives) with 0.3 ml distilled water was used for 3650 cycles (7300 strokes) for each specimen. Measurements for the color change, lightness, and translucency were measured after toothbrushing using a spectrophotometer. Statistical analysis compared outcomes using paired t-test, ANOVA, and Tukey post hoc test. RESULTS. The maximum color change was identified in SH (stained acid) [1.44 (0.40)], whereas the lowest was identified in EN (polished water) [0.66 (0.16)] material. The maximum and minimum loss of surface translucency was observed in SH (polished water) [12.3 (0.52)] and EN (stained acid) [6.5 (0.55)] specimens, respectively. Lastly, loss of lightness was the highest in VM (polished acid) [69 (0.95)], whereas the lowest was observed in CU (stained water) [56.7 (0.86)]. CONCLUSION. The comparison presented a significant effect of toothbrush abrasion on translucency and lightness of the hybrid resin ceramics. Color change was not significantly influenced irrespective of the storage medium employed. Surface staining demonstrated the preservation and stability of color and optical properties under the influence of toothbrush abrasion and chemical trauma.

Evaluation of the radiopacity of restorative materials with different structures and thicknesses using a digital radiography system

  • Yaylaci, Ayla;Karaarslan, Emine Sirin;Hatırli, Huseyin
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.261-269
    • /
    • 2021
  • Purpose: The aim of this study was to evaluate the radiopacities of various types of restorative materials with different thicknesses compared with enamel, dentin, and aluminum. Materials and Methods: Four bulk-fill resins, 2 hybrid ceramics, 2 micro-hybrid resin composites, 6 glass ionomer-based materials, 2 zinc phosphate cements, and an amalgam were used in the study. Twelve disk-shaped specimens were prepared from each of 17 restorative materials with thicknesses of 1 mm, 2 mm, and 4 mm (n=4). All the restorative material specimens with the same thickness, an aluminum (Al) step wedge, and enamel and dentin specimens were positioned on a phosphor storage plate and exposed using a dental X-ray unit. The mean gray values were measured on digital images and converted to equivalent Al thicknesses. Statistical analyses were performed using 2-way analysis of variance and the Bonferroni post hoc test(P<0.05). Results: Radiopacity was significantly affected by both the thickness and the material type (P<0.05). GCP Glass Fill had the lowest radiopacity value for samples of 1 mm thickness, while Vita Enamic had the lowest radiopacity value for 2-mm-thick and 4-mm-thick samples. The materials with the highest radiopacity values after the amalgam were zinc phosphate cements. Conclusion: Significant differences were observed in the radiopacities of restorative materials with different thicknesses. Radiopacity was affected by both the material type and thickness.

Influence of different universal adhesives on the repair performance of hybrid CAD-CAM materials

  • Demirel, Gulbike;Baltacioglu, Ismail Hakki
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.3
    • /
    • pp.23.1-23.9
    • /
    • 2019
  • Objectives: The aim of this study was to investigate the microshear bond strength (${\mu}SBS$) of different universal adhesive systems applied to hybrid computer-aided design/computer-aided manufacturing (CAD-CAM) restorative materials repaired with a composite resin. Materials and Methods: Four types of CAD-CAM hybrid block materials-Lava Ultimate (LA), Vita Enamic (VE), CeraSmart (CS), and Shofu Block HC (SH)-were used in this study, in combination with the following four adhesive protocols: 1) control: porcelain primer + total etch adhesive (CO), 2) Single Bond Universal (SB), 3) All Bond Universal (AB), and 4) Clearfil Universal Bond (CU). The ${\mu}SBS$ of the composite resin (Clearfil Majesty Esthetic) was measured and the data were analyzed using two-way analysis of variance and the Tukey test, with the level of significance set at p < 0.05. Results: The CAD-CAM block type and block-adhesive combination had significant effects on the bond strength values (p < 0.05). Significant differences were found between the following pairs of groups: VE/CO and VE/AB, CS/CO and CS/AB, VE/CU and CS/CU, and VE/AB and CS/AB (p < 0.05). Conclusions: The ${\mu}SBS$ values were affected by hybrid block type. All tested universal adhesive treatments can be used as an alternative to the control treatment for repair, except the AB system on VE blocks (the VE/AB group). The ${\mu}SBS$ values showed variation across different adhesive treatments on different hybrid CAD-CAM block types.

Comparative color and surface parameters of current esthetic restorative CAD/CAM materials

  • Egilmez, Ferhan;Ergun, Gulfem;Cekic-Nagas, Isil;Vallittu, Pekka Kalevi;Lassila, Lippo Veli Juhana
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.1
    • /
    • pp.32-42
    • /
    • 2018
  • PURPOSE. The purpose of this study was to derive and compare the inherent color (hue angle, chroma), translucency ($TP_{SCI}$), surface gloss (${\Delta}E^*_{SCE-SCI}$), and surface roughness ($R_a$) amongst selected shades and brands of three hybrid CAD/CAM blocks [GC Cerasmart (CS); Lava Ultimate (LU); Vita Enamic (VE)]. MATERIALS AND METHODS. The specimens (N = 225) were prepared into square-shaped ($12{\times}12mm^2$) with different thicknesses and shades. The measurements of color, translucency, and surface gloss were performed by a reflection spectrophotometer. The surface roughness and surface topography were assessed by white light interferometry. RESULTS. Results revealed that hue and chroma values were influenced by the material type, material shade, and material thickness (P < .001). The order of hue angle amongst the materials was LU > CS > VE, whereas the order of chroma was VE > CS > LU. $TP_{SCI}$ results demonstrated a significant difference in terms of material types and material thicknesses ($P{\leq}.001$). $TP_{SCI}$ values of the tested materials were ordered as LU > CS > VE. ${\Delta}E^*_{SCE-SCI}$ and $R_a$ results were significantly varied amongst the materials (P < .001) and amongst the shades (P < .05). The order of ${\Delta}E^*_{SCE-SCI}$ amongst the materials were as follows $LU>VE{\geq}CS$, whereas the order of $R_a$ was $CS{\geq}VE>LU$. CONCLUSION. Nano-ceramic and polymer-infiltrated-feldspathic ceramic-network CAD/CAM materials exhibited different optical, inherent color and surface parameters.

Evaluation of the repair capacities and color stabilities of a resin nanoceramic and hybrid CAD/CAM blocks

  • Bahadir, Hasibe Sevilay;Bayraktar, Yusuf
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.140-149
    • /
    • 2020
  • PURPOSE. This study evaluated the color stabilities of two computer-aided design and computer-aided manufacturing (CAD/CAM) blocks and a nanofill composite resin and the microtensile bond strength (µTBS) between the materials. MATERIALS AND METHODS. Twelve specimens of 4 mm height were prepared for both Lava Ultimate (L) and Vita Enamic (E) CAD/CAM blocks. Half of the specimens were thermocycled (10,000 cycle, 5° to 55℃) for each material. Both thermocycled and non-thermocycled specimens were surface treated with one of the three different methods (Er,Cr:YSGG laser, bur, or control). For each surface treatment group, one of the thermocycled and one of non-thermocycled specimens were restored using silane (Ceramic Primer II), universal adhesive (Single Bond Universal), and nanofill composite resin of 4-mm height (Filtek Ultimate). The other specimens were restored with the same procedure without using silane. For each group, 1 × 1 × 8 mm bar specimens were prepared using a microcutting device. Bar specimens were thermocycled (10,000 cycle, 5° to 55℃) and microtensile tests were performed. Staining of the materials in coffee solution was also compared using a spectrophotometer. Data were analyzed using one-way ANOVA, t-test and post-hoc Scheffe tests. RESULTS. µTBS were found similar between the thermocycled and non-thermocycled groups (P>.05). The highest µTBS (20.818 MPa) was found in the non-thermocycled, bur-ground, silane-applied E group. Silane increased µTBS at some E groups (P<.05). Composite resin specimens showed more staining than CAD/CAM blocks (P<.05). CONCLUSION. CAD/CAM blocks can be repaired with composite resins after proper surface treatments. Using silane is recommended in repair process. Color differences may be shown between CAD/CAM blocks and the nanofill composite after a certain time period.

Effects of staining liquids and finishing methods on translucency of a hybrid ceramic material having two different translucency levels

  • Buyukkaplan, Sebnem Ulviye;Ozarslan, Mehmet Mustafa;Barutcigil, Cagatay;Arslan, Merve;Barutcigil, Kubilay;Yoldan, Elif Ece
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.5
    • /
    • pp.387-393
    • /
    • 2017
  • PURPOSE. Beverages may affect the translucency of esthetic dental restorative materials.The aim of the present study was to investigate the effects of coffee and red wine on the translucency of a PICN material with two translucency levels, and finished with different methods. MATERIALS AND METHODS. 2M2 high translucent and translucent VITA Enamic hybrid ceramic blocks were investigated. Rectangular specimens with the dimensions of $12mm{\times}14mm{\times}2mm$ were prepared. The specimens were finished and polished with different methods as suggested by the manufacturer. The translucency parameters of the specimens were evaluated before and after 24 hours, 7 days, and 28 days immersion in distilled water, coffee and red wine. Translucency parameters were measured using a portable spectrophotometer. RESULTS. At the end of 28 days, there was no statistically significant difference between the groups of specimens kept in coffee (P>.05). In the red wine groups, there was a statistically significant difference between the control group and all other groups (P<.05) at the end of 28 days. CONCLUSION. The translucency of hybrid ceramic for a restoration may not be important regarding the effects of coffee on translucency change because the specimens with different translucencies and finishing methods that were immersed to coffee had similar translucency parameters at the end of 28 days. The translucency of hybrid ceramic may be important in the case of red wine, however, since the results showed that highly translucent specimens exposed to red wine demonstrated better translucency parameters than specimens made from translucent blocks at the end of 28 days.

The effects of different polishing techniques on the staining resistance of CAD/CAM resin-ceramics

  • Sagsoz, Omer;Demirci, Tevfik;Demirci, Gamze;Sagsoz, Nurdan Polat;Yildiz, Mehmet
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.6
    • /
    • pp.417-422
    • /
    • 2016
  • PURPOSE. The purposes of this study were to evaluate the staining resistance of CAD/CAM resin-ceramics polished with different techniques and to determine the effectiveness of the polishing techniques on resin-ceramics, comparing it with that of a glazed glass-ceramic. MATERIALS AND METHODS. Four different CAD/CAM ceramics (feldspathic ceramic: C-CEREC Blocs, (SIRONA) and three resin-ceramics: L-Lava Ultimate, (3M ESPE), E-Enamic, (VITA) and CS-CeraSmart, (GC)) and one light cure composite resin: ME-Clearfil Majesty Esthetic (Kuraray) were used. Only C samples were glazed (gl). Other restorations were divided into four groups according to the polishing technique: nonpolished control group (c), a group polished with light cure liquid polish (Biscover LV BISCO) (bb), a group polished with ceramic polishing kit (Diapol, EVE) (cd), and a group polished with composite polishing kit (Clearfil Twist Dia, Kuraray) (kc). Glazed C samples and the polished samples were further divided into four subgroups and immersed into different solutions: distilled water, tea, coffee, and fermented black carrot juice. Eight samples ($8{\times}8{\times}1mm$) were prepared for each subgroup. According to CIELab system, four color measurements were made: before immersion, immersion after 1 day, after 1 week, and after 1 month. Data were analyzed with repeated measures of ANOVA (${\alpha}=.05$). RESULTS. The highest staining resistance was found in gl samples. There was no difference among gl, kc and cd (P>.05). Staining resistance of gl was significantly higher than that of bb (P<.05). Staining resistances of E and CS were significantly higher than those of L and ME (P<.05). CONCLUSION. Ceramic and composite polishing kits can be used for resin ceramics as a counterpart of glazing procedure used for full ceramic materials. Liquid polish has limited indications for resin ceramics.

The effects of different surface treatments on the shear bond strengths of two dual-cure resin cements to CAD/CAM restorative materials

  • Turker, Nurullah;Buyukkaplan, Ulviye Sebnem;Basar, Ebru Kaya;Ozarslan, Mehmet Mustafa
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.4
    • /
    • pp.189-196
    • /
    • 2020
  • PURPOSE. The aim of the present study was to investigate the effects of surface treatments on the bond strengths between polymer-containing restorative materials and two dual-cure resin cements. MATERIALS AND METHODS. In the present study, rectangular samples prepared from Lava Ultimate (LU) and Vita Enamic (VE) blocks were used. The specimen surfaces were treated using CoJet sandblasting, 50 ㎛ Al2O3 sandblasting, % 9 HF (hydrofluoric) acid, ER,Cr:YSGG laser treatment, and Z-Prime. Dual-cure resin cements (TheraCem and 3M RelyX U 200) were applied on each specimen's treated surface. A micro-tensile device was used to evaluate shear bond strength. Statistical analysis was performed using the SAS 9.4v3. RESULTS. While the bond strength using TheraCem with LU or VE was not statistically significant (P=.164), the bond strength using U200 with VE was statistically significant (P=.006). In the TheraCem applied VE groups, Z-Prime and HF acid were statistically different from CoJet, Laser, and Sandblast groups. In comparison of TheraCem used LU group, there was a statistically significant difference between HF acid and other surface treatments. CONCLUSION. The bonding performance between the restorative materials and cements were material type-dependent and surface treatment had a large effect on the bond strength. Within the limitations of the study, the use of both U200 and TheraCem may be suggested if Z-prime was applied to intaglio surfaces of VE. The cementation of LU using TheraCem is suitable after HF acid conditioning of the restoration surfaces.

Wear evaluation of CAD-CAM dental ceramic materials by chewing simulation

  • Turker, Izim;Kursoglu, Pinar
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.5
    • /
    • pp.281-291
    • /
    • 2021
  • PURPOSE. To evaluate the wear of computer-aided design/computer-aided manufacturing (CAD-CAM) dental ceramic materials opposed by enamel as a function of increased chewing forces. MATERIALS AND METHODS. The enamel cusps of healthy human third molar teeth (n = 40) opposed by materials from CAD-CAM dental ceramic groups (n = 10), including Vita Enamic® (ENA), a polymer-infiltrated ceramic network (PICN); GC Cerasmart® (CERA), a resin nanoceramic; Celtra® Duo (DUO), a zirconia-reinforced lithium silicate (ZLS) ceramic; and IPS e.max ZirCAD (ZIR), a polycrystalline zirconia, were exposed to chewing simulation (1,200,000 cycles; 120 N load; 1 Hz frequency; 0.7 mm lateral and 2 mm vertical motion). The wear of both enamel cusps and materials was quantified using a 3D laser scanner, and the wear mechanisms were evaluated by scanning electron microscopy (SEM). The results were analysed using Welch ANOVA and Kruskal Wallis test (α = .05). RESULTS. ZIR showed lower volume loss (0.02 ± 0.01 mm3) than ENA, CERA and DUO (P = .001, P = .018 and P = .005, respectively). The wear of cusp/DUO [0.59 mm3 (0.50-1.63 mm3)] was higher than cusp/CERA [0.17 mm3 (0.04-0.41 mm3)] (P = .007). ZIR showed completely different wear mechanism in SEM. CONCLUSION. Composite structured materials such as PICN and ZLS ceramic exhibit more abrasive effect on opposing enamel due to their loss against wear, compared to uniform structured zirconia. The resin nano-ceramic causes the lowest enamel wear thanks to its flexible nano-ceramic microstructure. While zirconia appears to be an enamel-friendly material in wear volume loss, it can cause microstructural defects of enamel.