• Title/Summary/Keyword: VEINS Simulation

Search Result 3, Processing Time 0.019 seconds

Model for the Connection-Time of Vehicle-to-Mobile RSU (V2MR) Communications Near a Bus Station (버스 정류소 주변에서 자동차-이동기지국 (V2MR) 통신의 연결시간에 대한 성능분석모형)

  • Jeong, Han-You;Purnaningtyas, Magdalena Trie;Nguyen, Hoa-Hung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.12
    • /
    • pp.1969-1977
    • /
    • 2016
  • We study the connection time of vehicle-to-mobile roadside unit (V2MR) communications which can reduce the significant cost of the fixed RSU by installing a gateway of mobile network into a transit bus called the mobile RSU. In the V2MR communications, the connectivity of a commute vehicle can be improved via ad-hoc connection to a nearby mobile RSU. In this paper, we present a new analysis model to estimate the connection time between a commute vehicle and a mobile RSU, when there is a bus station in the overlapping route. Since the connection time between two vehicles is highly dynamic and unpredictable, our analysis will provide a fundamental basis of connection-time estimation of V2MR communications. Numerical results obtained from VEINS simulation show that our analysis can estimate the connection time of V2MR communications with the average error below 1.0 percent. Moreover, we show that the average connection time of V2MR communications can be extended to approximately 3.85 times of that of V2R communications.

Computational Study on the Hemodynamic Behaviors of the Human Cardiovascular System with an Acute Arteriovenous Fistula (급성 동정맥루를 포함하는 인체 심혈관계의 혈류역학적 거동에 관한 수치 해석적 연구)

  • 변수영;손정락;심은보;노승탁
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.329-337
    • /
    • 2003
  • Blood in congenital or acquired AY fistula(arteriovenous fistula) flows from arteries directly to veins. detouring peripheral micro-circulation. This makes a great effect on the hemodynamics of human cardiovascular system. In this study, a computational method using lumped parameter mode) was proposed to simulate the cardiovascular hemodynamics of patients with acute AV fistula The cardiovascular system model with a fistula compartment in left lower limb was built using 17 standard lumped compartments. Using fourth order Runge-Kutta method. we solved numerically the unsteady linear set of the ordinary differential equations resulting from application of Kirchhoff's law to the lumped parameter hemodynamic model. The baroreceptor reflex system was implemented to explain the auto-regulation effect of the cardiovascular system with acute AV fistula.

A Study of Feasibility of Dipole-dipole Electric Method to Metallic Ore-deposit Exploration in Korea (국내 금속광 탐사를 위한 쌍극자-쌍극자 전기탐사의 적용성 연구)

  • Min, Dong-Joo;Jung, Hyun-Key;Park, Sam-Gyu;Chon, Hyo-Taek;Kwak, Na-Eun
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.3
    • /
    • pp.250-262
    • /
    • 2008
  • In order to assess the feasibility of the dipole-dipole electric method to the investigation of metallic ore deposit, both field data simulation and inversion are carried out for several simplified ore deposit models. Our interest is in a vein-type model, because most of the ore deposits (more than 70%) exist in a vein type in Korea. Based on the fact that the width of the vein-type ore deposits ranges from tens of centimeters to 2m, we change the width and the material property of the vein, and we use 40m-electrode spacing for our test. For the vein-type model with too small width, the low resistivity zone is not detected, even though the resistivity of the vein amounts to 1/300 of that of the surrounding rock. Considering a wide electrode interval and cell size used in the inversion, it is natural that the size of the low resistivity zone is overestimated. We also perform field data simulation and inversion for a vein-type model with surrounding hydrothermal alteration zones, which is a typical structure in an epithermal ore deposits. In the model, the material properties are assumed on the basis of resistivity values directly observed in a mine originated from an epithermal ore deposits. From this simulation, we can also note that the high resistivity value of the vein does not affect the results when the width of the vein is narrow. This indicates that our main target should be surrounding hydrothermal alteration zones rather than veins in field survey. From these results, we can summarize that when the vein is placed at the deep part and the difference of resistivity values between the vein and the surrounding rock is not large enough, we cannot detect low resistivity zone and interpret the subsurface structures incorrectly using the electric method performed at the surface. Although this work is a little simple, it can be used as references for field survey design and field data Interpretation. If we perform field data simulation and inversion for a number of models and provide some references, they will be helpful in real field survey and interpretation.