• Title/Summary/Keyword: VCT

Search Result 35, Processing Time 0.081 seconds

Investigation of the concentration characteristic of RCS during the boration process using a coupled model

  • Xiangyu Chi;Shengjie Li;Mingzhou Gu;Yaru Li;Xixi Zhu;Naihua Wang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2757-2772
    • /
    • 2023
  • The fluid retention effect of the Volume Control Tank (VCT) leads to a long time delay in Reactor Coolant System (RCS) concentration during the boration process. A coupled model combining a lumped-parameter sub-model and a computational fluid dynamics sub-model is currently used to investigate the concentration dynamic characteristic of RCS during the boration process. This model is validated by comparison with experimental data, and the predicted results show excellent agreement with experimental data. We provide detailed fields in VCT and concentration variations of RCS to study the interaction between mixing in VCT and the transient responses of RCS. Moreover, the impacts of the inlet flow rate, inlet nozzle diameter, original concentration, and replenishing temperature of VCT on the RCS concentration characteristic are studied. The inlet flow rate and nozzle diameter of VCT remarkably affect the RCS concentration characteristic. Too-large or too-small inlet flow rates and nozzle diameters will lead to unacceptable long delays. In this work, the optimal inlet flow rate and nozzle diameter of VCT are 5 m3/h and 58.8 mm, respectively. Besides, the impacts of the original concentration and replenishing temperature of VCT are negligible under normal operating conditions.

Comparison of 64 Channel 3 Dimensional Volume CT with Conventional 3D CT in the Diagnosis and Treatment of Facial Bone Fractures (얼굴뼈 골절의 진단과 치료에 64채널 3D VCT와 Conventional 3D CT의 비교)

  • Jung, Jong Myung;Kim, Jong Whan;Hong, In Pyo;Choi, Chi Hoon
    • Archives of Plastic Surgery
    • /
    • v.34 no.5
    • /
    • pp.605-610
    • /
    • 2007
  • Purpose: Facial trauma is increasing along with increasing popularity in sports, and increasing exposure to crimes or traffic accidents. Compared to the 3D CT of 1990s, the latest CT has made significant improvement thus resulting in higher accuracy of diagnosis. The objective of this study is to compare 64 channel 3 dimensional volume CT(3D VCT) with conventional 3D CT in the diagnosis and treatment of facial bone fractures. Methods: 45 patients with facial trauma were examined by 3D VCT from Jan. 2006 to Feb. 2007. 64 channel 3D VCT which consists of 64 detectors produce axial images of 0.625 mm slice and it scans 175 mm per second. These images are transformed into 3 dimensional image using software Rapidia 2.8. The axial image is reconstructed into 3 dimensional image by volume rendering method. The image is also reconstructed into coronal or sagittal image by multiplanar reformatting method. Results: Contrasting to the previous 3D CT which formulates 3D images by taking axial images of 1-2 mm, 64 channel 3D VCT takes 0.625 mm thin axial images to obtain full images without definite step ladder appearance. 64 channel 3D VCT is effective in diagnosis of thin linear bone fracture, depth and degree of fracture deviation. Conclusion: In its expense and speed, 3D VCT is superior to conventional 3D CT. Owing to its ability to reconstruct full images regardless of the direction using 2 times higher resolution power and 4 times higher speed of the previous 3D CT, 3D VCT allows for accurate evaluation of the exact site and deviation of fine fractures.

Absorbed and effective dose from newly developed cone beam computed tomography in Korea (최근 개발된 cone beam computed tomography의 흡수선량 및 유효선량 평가)

  • Lee, Jong-Nyeong;Han, Won-Jeong;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.37 no.2
    • /
    • pp.93-102
    • /
    • 2007
  • Purpose: Cone beam computed tomography (CBCT) provides a lower dose and cost alternative to conventional CT, promising to revolutionize the practice of oral and maxillofacial radiology. The purpose of this study was to evaluate the absorbed and effective doses of Implagraphy and VCT (Vatech Co., Hwasung, Korea) and compare them with those of panoramic radiography. Materials and Methods: Thermoluminescent dosimeter (TLD) chips were placed at 27 sites throughout the layers of Female ART Head and Neck Phantom for dosimetry. Implagraphy, VCT units, and Planmeca Proline XC panoramic unit were used for radiation exposures. Radiation weighted doses and effective doses were measured and calculated using 1990 and 2005 ICRP tissue weighting factors. Results: Effective doses in Sv (ICRP 2005, ICRP 1990) were 90.19, 61.62 for Implagraphy at maxillay molar area, 123.20, 90.02 for Implagraphy at mandibular molar area, 183.55, 139.26 for VCT and 40.92, 27.16 for panoramic radiography. Conclusion: Effective doses for VCT and Implagraphy were only about 2.2 to 4.5 times greater than those for panoramic radiography. VCT and Implagraphy, CBCT machines recently developed in Korea, showed moderately low effective doses.

  • PDF

Dose Evaluation of Dental Artifacts Using MVCT in Head and Neck (두경부암 환자의 MVCT를 이용한 치아 인공물 보정에 따른 선량평가)

  • Shin, Chung Hun;Yun, In Ha;Jeon, Su Dong;Kim, Jeong Mi;Kim, Ho Jin;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.25-31
    • /
    • 2019
  • Purpose: Metals induce metal artifact during CT-image for therapy planning, and it occurs images distortion, which affects the volumetric measurement and radiation calculation. In the case of using megavoltage computed tomography(MVCT), the volume of metals can be measured as similar to true volume due to minimal metal artifact outcome. In this study, radiation assessment was conducted by comparing teeth volume from images of kVCT and MVCT of head and neck cancer patients, then assigning to kVCT image to calculate radiation after obtaining the similar volume of true teeth volume from MVCT. Also, formal IR image was able to verify the accuracy of radiation calculation. Material and method: 5 head and neck cancer patients who had intensity-modulated radiation therapy from Radixact® Series were of the subject in this study. Calculations of radiation when constraining true teeth volume out of kVCT image(A-CT) and when designated specific HU after teeth assigned using MVCT image were compared with formal IR image. Treatment planning was devised at the same constraints and mean dose was measured at the radiation assess points. The points were anterior of the teeth, between PTV and the teeth, the interior of PTV near the teeth, and the teeth where 5cm distance from PTV. Result: A difference of metals volume from kVCT and MVCT image was mean 3.49±2.61cc, maximum 7.43cc. PTV was limited to where the internal teeth were fully contained. The results of PTV dose evaluation showed that the average CI value of the kVCT treatment planning without the artifact correction was 0.86, and the average CI value of the kVCT with the artifact correction using MVCT image was 0.9. Conclusion: When the Treatment Planning was made without correction of metal artifacts, the dose of PTV was underestimated, indicating that dose uncertainty occurred. When the computerized treatment plan was made without correction of metal artifacts, the dose of PTV was underestimated, indicating that dose uncertainty occurred.

Study on Improvement for Inefficient Resource Reservation in VCT Handover (VCT 핸드오버의 비효율적 자원예약 개선방안에 대한 연구)

  • 한진백;정기운;송주석
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1999.10c
    • /
    • pp.661-663
    • /
    • 1999
  • 무선 ATM 환경에서 이동단말기의 이동성을 지원하기 위한 핸드오버방식인 VCT 핸드오버방식은 트리개념을 도입하여 이동단말이 이동할 수 있는 구역내의 모든 기지국에 대하여 사전에 모든 연결을 설정하는 방식으로서, 신속한 핸드오버가 가능하고, 핸드오버 후에도 QoS를 쉽게 보장할 수 있다는 장점이 있으나, 망 자원의 사용면에서 비효율적인 문제점을 갖고 있다. 따라서, 본 논문에서는 이동단말의 이동성을 고려하여 이동이 예상되는 셀에 대해서만 미리 자원을 예약함으로써 불필요하게 예약되는 자원의 낭비를 줄일 수 있는 방안에 대해 제시하고, 이에 대한 성능을 평가하고자 한다.

  • PDF

Evaluation of Engine Lubrication System for Adapting Variable Cam Timing System (VCT탑재를 위한 엔진윤활시스템 평가)

  • Yun Jeong-Eui
    • Tribology and Lubricants
    • /
    • v.22 no.1
    • /
    • pp.14-19
    • /
    • 2006
  • VCT(Variable Cam Timing) system is one of very useful engine components to improve fuel economy and overcome emission regulation etc. In order to adapt the VCT to a base engine, many design mod ifications in the mechanical and lubrication fields are required. Especially, because the VCT performance itself depends on supplied oil flow rate and pressure, it is very important to evaluate the engine lubrication system in a viewpoint of supplied oil flow rate and pressure. In this paper, unsteady transient flow network analysis on the engine oil circuit system was carried out to do this.

Nondestructive Buckling Load Prediction of Pressurized Unstiffened Metallic Cylinder Using Vibration Correlation Technique (Vibration Correlation Technique을 이용한 내부 압력을 받는 금속재 단순 원통 구조의 비파괴적 전역 좌굴 하중 예측)

  • Jeon, Min-Hyeok;Kong, Seung-Taek;Cho, Hyun-Jun;Kim, In-Gul;Park, Jae-Sang;Yoo, Joon-Tae;Yoon, Yeoung-Ha
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.2
    • /
    • pp.75-82
    • /
    • 2022
  • Nondestructive method to predict buckling load for the propellant tank of launch vehicle should be evaluated. Vibration correlation technique can predict the global buckling load of unstiffened cylindrical structure with geometric initial imperfection using correlation of natural frequency and compressive load from compressive test below the buckling load. In this study, vibration and buckling tests of a thin metal unstiffened propellant tank model subjected to internal pressure and compressive loads were performed and the test results were used for VCT to predict global buckling load. For the vibration test of thin structure, non-contact excitation method using a speaker was used. The response was measured with piezoelectric polymer(PVDF) sensor. Prediction results of VCT were compared with the measured buckling load in the test and the nondestructive global buckling load prediction method was verified.

Performance Evaluation of Bidirectional MIN Using Hierarchical Buffering Scheme on Non-Uniform Traffic Under HWCR (혼합 웜홀 컷-스루 라우팅 하에서 비균형 트래픽시 계측적 버퍼를 사용한 양방향 MIN의 성능평가)

  • 장창수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.7A
    • /
    • pp.1234-1249
    • /
    • 2001
  • 본 논문에서는 확장 가능한 병렬컴퓨터 시스템의 성능에 중요한 영향을 주는 MIN에서 통신 지연을 개선하기 위한 방법에 대해 고찰하였다. 네트워크의 트래픽이 매우 많거나 고르지 않게 분포되었을 때 개선하기 위한 효율적인 스위칭 방안으로, 본 논문에서 제안된 HWCR 스위칭 방법은 양방향 MIN 상에서 웜홀 라우팅을 수행시 라우팅 경로 상에 패킷들이 충돌이 발생하여 링크가 블럭되었을 때 VCT로 전환하는 방법이다. 각 스위치에 계층적 버퍼를 설치함으로서 더욱 효율적인 라우팅을 할 수 있도록 설계하였다. 이는 VCT 라우팅이 일률적으로 각 스테이지마다 커다란 크기의 버퍼를 부여함에 반하여 매우 Cost-Effective 한 버퍼 할당 방법이다. 이를 정당화하고 버퍼크기와 라우팅시 평균 통신 지연과의 관계를 적정화하기 위해 균일 트래픽 패턴과 여러 가지 비균일 트래픽 패턴 하에서 성능평가를 하였다. 성능결과는 부하가 0.4 일 때 제안된 HWCR 방법이 VCT 라이팅 보다 2-3배의 버퍼가 절약됨을 보여준다.

  • PDF

A Study on the Improvement of Validation and Application for Slipmeters using Reference Surfaces (표준 바닥재를 이용한 미끄럼 측정기의 검증방법 개선 및 활용방안)

  • Kim, Jung-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.6
    • /
    • pp.73-78
    • /
    • 2013
  • The purpose of this study was to evaluate three kinds of slipmeters (BOT, BPT, English XL) used on-site floor with ASTM F2508 which is comprised of four different standard surfaces(polished granite, glazed porcelain, vinyl composite tile ;VCT, and ceramic tile). ASTM F2508 has two criteria that decide which slipmeter is appropriate or not. The evaluated slipmeters were dreg sled, articulated sturt, and pendulum strike type. The test results revealed that two kinds of slipmeters(BOT, BPT) successfully ranked all four standard surfaces and differentiated among standard surfaces with varying degrees of slipperiness. Nevertheless, the measured value with BOT on the VCT, which was reported as slippery floor in previous study, was higher than its threshold(0.6). Although some slipmeter satisfy two criteria of ASTM F2508, they can underestimate the slip potential. So, another criteria is needed so as to reduce this problem. English XL couldn't properly measure slipperiness under the two kind of floors(glazed porcelain, VCT). So the slider of English XL was modified in order to meet two criteria of ASTM F2508.

The Estimation of Buckling Load of Pressurized Unstiffened Cylindrical Shell Using the Hybrid Vibration Correlation Technique Based on the Experimental and Numerical Approach (실험적/수치적 방법이 혼합된 VCT를 활용한 내부 압력을 받는 원통형 쉘의 좌굴 하중 예측)

  • Lee, Mi-Yeon;Jeon, Min-Hyeok;Cho, Hyun-Jun;Kim, Yeon-Ju;Kim, In-Gul;Park, Jae-Sang
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.10
    • /
    • pp.701-708
    • /
    • 2022
  • Since the propellant tank structure of the projectile is mainly subjected to a compressive force, there is a high risk of damage due to buckling. Large and lightweight structures such as propellant tank have a complex manufacturing process. So it requires a non-destructive test method to predict buckling load to use the structure after testing. Many studies have been conducted on Vibration Correlation Technique(VCT), which predicts buckling load using the relationship between compressive load and natural frequency, but it requires a large compressive load to predict the buckling load accurately, and it tends to decrease prediction accuracy with increasing internal pressure in structure. In this paper, we analyzed the causes of the decrease in prediction accuracy when internal pressure increases and proposed a method increasing prediction accuracy under the low compressive load for being usable after testing, through VCT combined testing and FEA result. The prediction value by the proposed method was very consistent with the measured actual buckling load.