• Title/Summary/Keyword: VBC

Search Result 33, Processing Time 0.029 seconds

Humidity Sensitive Properties of Humidity Sensor using Quaternized Cross-linked Copolymers of Vinylbenzyl chloride (4차 염화 가교화된 Vinylbenzyl chloride 공중합체를 감습막으로 이용한 습도센서의 감습 특성)

  • Lee, Seong-Su;Gong, Myeong-Seon
    • Korean Journal of Materials Research
    • /
    • v.10 no.12
    • /
    • pp.825-830
    • /
    • 2000
  • The copolymers with various composition of vinylbenzyl chloride (VBC), methyl methacrylate (MMA), and 2-hydroxyethyl methacrylate(HEMA) were synthesized as a humidity sensitive material and quaternized with N, N, N', N'-tetraethylene diamine.. Resistance versus relative humidity decreased with increase in the content of MMA in the copolymer. The introduction of HPMA increased the resistance of the humidity sensor as well as enhanced the adherence to the alumina substrate. In the case of VBC/MMA/HEMA=80/10/10, the hysteresis and temperature dependency coefficient were $\pm$2%RH and -0.46~0.42%RH/$^{\circ}C$. The average resistance at 30%RH, 60%RH and 90%RH were 3.0M$\Omega$ ,200k$\Omega$ and 9k$\Omega$, respectively.

  • PDF

Real-Time Monitoring of Catheter-Related Biofilm Infection in Mice

  • Liu, Xu;Yin, Hong;Xu, Xianxing;Cheng, Yuanguo;Cai, Yun;Wang, Rui
    • Journal of Microbiology and Biotechnology
    • /
    • v.25 no.10
    • /
    • pp.1728-1733
    • /
    • 2015
  • This study was done to establish a mouse model for catheter-related biofilm infection suitable to bioluminescence imaging (BLI). Biofilm formation of Pseudomonas aeruginosa (P. aeruginosa) Xen5 grown on catheter disks in vitro and in an implanted mouse model was real-time monitored during a 7-day study period using BLI. The numbers of integrated brightness (IB) and viable bacterial count (VBC) in the biofilm disks in vitro were highest at 24 h after inoculation; the IB of biofilm in vivo was increased until 24 h after implantation. A statistical correlation was observed between IB and VBC in vitro by linear regression analysis. The actual VBC value in vivo can be estimated accurately by IB without sacrifice. In addition, we monitored the change in white blood cells (WBCs) during infection. The number of WBCs on day 7 was significantly higher in the infection group than in the control group. This study indicates that BLI is a simple, fast, and sensitive method to measure catheter biofilm infection in mice.

Lineage Tracing: Computational Reconstruction Goes Beyond the Limit of Imaging

  • Wu, Szu-Hsien (Sam);Lee, Ji-Hyun;Koo, Bon-Kyoung
    • Molecules and Cells
    • /
    • v.42 no.2
    • /
    • pp.104-112
    • /
    • 2019
  • Tracking the fate of individual cells and their progeny through lineage tracing has been widely used to investigate various biological processes including embryonic development, homeostatic tissue turnover, and stem cell function in regeneration and disease. Conventional lineage tracing involves the marking of cells either with dyes or nucleoside analogues or genetic marking with fluorescent and/or colorimetric protein reporters. Both are imaging-based approaches that have played a crucial role in the field of developmental biology as well as adult stem cell biology. However, imaging-based lineage tracing approaches are limited by their scalability and the lack of molecular information underlying fate transitions. Recently, computational biology approaches have been combined with diverse tracing methods to overcome these limitations and so provide high-order scalability and a wealth of molecular information. In this review, we will introduce such novel computational methods, starting from single-cell RNA sequencing-based lineage analysis to DNA barcoding or genetic scar analysis. These novel approaches are complementary to conventional imaging-based approaches and enable us to study the lineage relationships of numerous cell types during vertebrate, and in particular human, development and disease.

Preparation of Crosslinked Polyvinylbenzylchloride Anion Exchange Composite Membranes using Fabric Substrates and Their Electrodialysis Application for Ion Removal (천지지체를 사용한 가교화된 폴리비닐벤질클로라이드 음이온교환 복합막의 제조와 전기투석을 이용한 이온 제거 특성연구)

  • Lee, Jung-Soo;Chang, Bong-Jun;Kim, Jeong-Hoon;Kim, Dong-Kwon
    • Membrane Journal
    • /
    • v.20 no.2
    • /
    • pp.142-150
    • /
    • 2010
  • A series of anion exchange composite membranes were prepared and characterized for electrodialysis processes used in the removal of nitrate nitrogen and ions in groundwater. The membranes were prepared as follows; first, fabric substrates were fully impregnated with monomer mixtures of vinylbenzylchloride (VBC), divinylbenzene (DVB), Styrene (ST) and $\alpha,\alpha$-Azobis(isobutyronitrile) (AIBN). Second, they were thermally polymerized to yield crosslinked poly (VBCST- DVB)/fabric composite membranes. Finally, the membranes were treated with trimethylamine (TMA) / acetone to give $-N^+(CH_3)_3^-$-containing poly(VBC-ST-DVB)/fabric membranes. The basic membrane properties such as ion exchange capacity (IEC), electric resistance and water content of the resulting membranes were measured as a function of VBC/DVB and TMA/Acetone content. As a result, the composite membranes showed lower electric resistance and higher IEC than commercial anion exchange membranes (AMX, Astom). Electrodialysis tests using the prepared membranes were carried out for the removal of various ions such as $NaNO_3$, $MgSO_4$ and NaF for 60 minutes. The results showed that the ions were removed below 1 mg/L within about 15 minutes which indicates that the anion exchange membranes prepared here could be applied to the electrodialysis process. as can be seen in the following that the ion conductivity values were almost no change after 15 minutes electrodialysis.

An improved adaptive control technique for the Voltage Bus Conditioner with parallel loads in the DC Power Distribution System (병렬 부하를 갖는 DC배전 시스템을 위한 Voltage Bus Conditioner의 향상된 적응제어)

  • Lee, Byung-Hun;Chang, Han-sol;La, Jae-Du;Kim, Young-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.249-250
    • /
    • 2011
  • In DC Power Distribution System(DC PDS), a bus voltage instability is occurred by multiple parallel loads. The Voltage Bus Conditioner(VBC) is used to mitigate the DC bus voltage transient. An adaptive controller of the VBC is designed and the simulation result of the controller is verified by PSIM simulation package for the proposed control technique.

  • PDF

The Comparison of Two Control Algorithm for a Voltage Bus Conditioner in a DC Power Distribution System (DC 전력시스템에서의 Voltage Bus Conditioner의 제어기법 비교)

  • La, Jae-Du;Lee, Yong-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.1
    • /
    • pp.47-53
    • /
    • 2006
  • A Voltage Bus Conditioner (VBC) is used to mitigate the voltage transients on a common power distribution bus. The VBC described here utilises inductive storage and unlike its counter part with capacitive storage, it can employ the entire stored energy towards transients' mitigation. The performances of adaptive duty ratio control and sliding mode control have been compared. The simulation results (with the package SABER) indicate that the sliding mode control results in the shortest and the smallest bus voltage excursions.

A Unity Power Factor Electronic Ballast for Fluorescent Lamp having Improved Valley Fill and Valley Boost Converter (개선된 밸리필과 밸리용 승압형 변환기를 결합한 고역률 형광등용 전자식 안정기)

  • Youn, Yong-Sik;Chae, Gyun;Cho, Gyun-Hyeong
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2002-2006
    • /
    • 1997
  • A new PF correction topology, Improved Valley Fill (IVF) with Valley Boost Converter (VBC) used in the electronic ballast for fluorescent lamp is presented. The IVF can adjust the valley voltage higher than half the peak line voltage. Hence, there is no pulsating line current around the line voltage peak, PF and THD are significantly improved. The VBC is added to the IVF to achieve unity PF and to increase the valley voltage. The measured PF and THD for a prototype electronic ballast are 0.997 and 5%, respectively, and the lamp current CF is as low as 1.5

  • PDF

The PI control of the Voltage Bus Conditioner for the improvement of the Power Quality in the DC Power Distribution System with multiple parallel loads (다중 병렬 부하를 가지는 DC 배전 시스템에서의 전력 품질 향상을 위한 Voltage Bus Conditioner의 PI 제어)

  • Lee, Byung-Hun;Woo, Hyun-Min;La, Jae-Du;Shin, Jae-Hwa;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1234-1235
    • /
    • 2011
  • A DC Power Distribution Systems(DC PDS) are widely used in telecommunication system, electric vehicle, aircraft, military system, etc. In the DC PDS, DC bus voltage instability may be occurred by the operation of multiple loads such as pulsed power load, motor drive system, and constant power loads. To damp the transients of the DC bus voltage, the Voltage Bus Conditioner(VBC) with the PI compensator is used. In this paper, the validity of the proposed VBC system is verified by PSIM simulation package.

  • PDF

The Design of the PI Compensator for a Voltage Bus Conditioner in the DC Distributed Power System (DC 배전시스템에서 Voltage Bus Conditioner를 위한 PI 보상기 설계)

  • Kim, Young-Seok;Seok, Bong-Jun;La, Jae-Du
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.12
    • /
    • pp.2195-2201
    • /
    • 2010
  • The VBC(Voltage Bus Conditioner) is a bidirectional DC-DC converter with the energy storage for damping the instability and any transients of bus voltage in the DC DPS(Distributed Power System). This paper presents the PI(Proportional Integration) controller for the VBC. The PI controller is not only damping the bus transient, but also keeping the storage voltage level. Matlab Simulink simulation and experimental results are presented by validity of the proposed control technique.

A Voltage Bus Conditioner for a High Voltage DC Power Distribution System using High Performance Hysteresis Control (고성능 히스테리 제어를 이용한 고전압 DC 전력시스템을 위한 Voltage Bus Conditioner)

  • La, Jae-Du
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.2
    • /
    • pp.90-98
    • /
    • 2007
  • More and All-Electric Aircraft (AEA) carry many loads with varied functions. In particular, there may be large pulsed loads with short duty ratio, which can affect the normal operation of other loads. In this paper, a bi-directional converter with inductive storage is used as a voltage bus conditioner (VBC) to mitigate voltage transients on the bus. In addition, the constant frequency hysteresis control technique for a VBC is presented. A simple and fast prediction of the hysteresis band-width is implemented by the phase-lock loop control, keeping constant switching frequency. This technique offers the excellent dynamic response in load or parameter variation. The control performance is illustrated by simulated results with the SABER package, The proposed hysteresis control results in the shortest and the smallest excursions.