• Title/Summary/Keyword: VAD

Search Result 217, Processing Time 0.028 seconds

Induction of the Intrinsic Apoptotic Pathway by 3-Deazaadenosine Is Mediated by BAX Activation in HL-60 Cells

  • Lee, Sun-Young;Ko, Kyoung-Won;Kang, Won-Kyung;Choe, Yun-Jeong;Kim, Yoon-Hyoung;Kim, In-Kyung;Kim, Jin;Kim, Ho-Shik
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.14 no.6
    • /
    • pp.407-412
    • /
    • 2010
  • 3-Deazaadenosine (DZA), a potent inhibitor of S-adenosylhomocysteine hydrolase, was previously proposed to induce intrinsic apoptosis in human leukemic cells. In the present study, we analyzed the mechanism underlying the DZA-induced intrinsic apoptotic pathway. DZA activated typical caspase-dependent apoptosis in HL-60 cells, as demonstrated by an accumulation of hypo-diploidic cells, the processing of multiple procaspases and an inhibitory effect of z-VAD-Fmk on this cell death. During DZA-induced apoptosis, cytochrome c (cyt c) was released into the cytosol. This was neither prevented by z-VAD-Fmk and nor was it associated with the dissipation of mitochondrial membrane potential (${\Delta}{\Psi}_m$). Prior to the release of cyt c, BAX was translocated from the cytosol to mitochondria and underwent oligomerization. Finally, the overexpression of BCL-XL protected HL-60 cells from apoptosis by blocking both the cyt c release and BAX oligomerization. Collectively, these findings suggest that DZA may activate intrinsic apoptosis by stimulating BAX activation and thereby the release of cyt c.

Cobalt Chloride Induces Necroptosis in Human Colon Cancer HT-29 Cells

  • Wang, Hai-Yu;Zhang, Bo
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.6
    • /
    • pp.2569-2574
    • /
    • 2015
  • Necroptosis, also known as "programmed necrosis", has emerged as a critical factor in a variety of pathological and physiological processes and is considered a cell type-specific tightly regulated process with mechanisms that may vary rather greatly due to the change of cell line. Here we used HT-29, a human colon cancer cell line, to establish a necroptosis model and elucidate associated mechanisms. We discovered that cobalt chloride, a reagent that could induce hypoxia-inducible $factor-1{\alpha}(HIF1{\alpha})$ expression and therefore mimic the hypoxic microenvironment of tumor tissue in some aspects induces necroptosis in HT-29 cells when caspase activity is compromised. On the other hand, apoptosis appears to be the predominant death form when caspases are functioning normally. HT-29 cells demonstrated significantly increased RIPK1, RIPK3 and MLKL expression in response to cobalt chloride plus z-VAD treatment, which was accompanied by drastically increased $IL1{\alpha}$ and IL6 expression, substantiating the notion that necrosis can induce profound immune reactions. The RIPK1 kinase inhibitor necrostatin-1 and the ROS scavenger NAC each could prevent necrosis in HT-29 cells and the efficiency was enhanced by combined treatment. Thus by building up a necroptosis model in human colon cancer cells, we uncovered that mechanically RIP kinases collaborate with ROS during necrosis promoted by cobalt chloride plus z-VAD, which leads to inflammation. Necroptosis may present a new target for therapeutic intervention in cancer cells that are resistant to apoptotic cell death.

Accuracy and Precision of Ion Chromatography/Visible Absorbance Detection for Analyzing Hexavalent Chromium Collected on PVC Filter (Ion Chromatography/Visible Absorbance Detection을 이용한 Cr(VI) 분석의 정확도 및 정밀도 평가)

  • Shin, Yong Chul;Oh, Se Min;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.223-232
    • /
    • 1997
  • The accuracy and precision of a modified method of NIOSH Method 7600 and EPA method 218.6 was determined for analyzing hexavalent chromium, Cr(VI), collected on PVC filter from workplace air. The method was designed to extract from Cr(VI) on PVC filter with a alkali solution, 2% NaOH/3% $Na_2CO_3$, and to analyze it using ion chromatography/visible absorbance detection(IC/VAD). The results and conclusion are as the following. 1. The peak of Cr(VI) was separated sharply on chromatogram and was linearly related with Cr(VI) concentration in sloution. The correlation coefficient was 0.9999 in a calibration curve. The limit of detection was 0.25 $0.25{\mu}g/sample$. 2. The accuracy(% recovery) was 93.3% in a set of sample($9-50{\mu}g$) stored for a day, and 100.1%($10-60{\mu}g$) in another set of samples stored for 2 hours. It is assumed that the difference in recovery by storage time was due to reduction of Cr(VI) to Cr(III). 3. The precision(coefficient of variation, CV) of the method was 0.015 in spiked samples with Cr(VI) standard solution, and 0.010 in spiked samples with plating solution from a chrome electroplating factory. The overall CV in all types of samples was 0.0013. 4. The Cr(VI) was stable in 2% NaOH/3% $Na_2CO_3$ at least for 10 hours. In conclusion, the IC/VAD method is appropriate for determining low-level Cr(VI) in workplace air containing various interferences.

  • PDF

The Application of a Bi-ventricular Assist Device for a Low Weight (2.4 kg) Neonate with Coarctation of the Aorta and Critical Aortic Stenosis (대동맥 축착증 및 심한 대동맥 협착을 가진 저체중 신생아(2.4 kg)의 수술 전후 발생한 심실 기능 부전의 치료에 대한 양심실 보조 장치 적용 치험 예)

  • Kwak, Jae-Gun;Park, Chun-Soo;Lee, Chang-Ha;Lee, Cheul
    • Journal of Chest Surgery
    • /
    • v.43 no.3
    • /
    • pp.304-307
    • /
    • 2010
  • A 5-day-old neonate (body weight=2.4 kg) with coarctation of the aorta and critical aortic stenosis underwent an interventional balloon valvuloplasty for aortic stenosis. During the intervention, cardiac arrest occurred due to injury of the right carotid artery by the guide wire. An extracorporeal membrane oxygenator (ECMO) was applied. After 1 day's support, total surgical correction was achieved; however, in the immediate postoperative period, cardiac function was severely depressed. We applied a bi-ventricular assist device (bi-VAD) instead of an ECMO and we were able to wean the patient off the bi-VAD device after 3 days' support. The patient was discharged without severe complications.

A development of the virtual auditory display system that allows listeners to move in a 3D space (청취자가 이동이 가능한 청각 디스플레이 시스템 개발)

  • Kang, Dae-Gee;Lee, Chai-Bong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.1
    • /
    • pp.1-5
    • /
    • 2012
  • In this study, we constructed a virtual auditory display(VAD) that enables listener to move in a room freely. The VAD system was installed in a soundproof room($4.7m(W){\times}2.8m(D){\times}3.0m(H)$). The system consisted of a personal computer, a sound presentation device, and a three-dimensional ultrasound sensor system. This system acquires listener's location and position from a three-dimension ultrasonic sensor system covering the entire room. Localization was realized by convolving the sound source with head related transfer functions(HRTFs) on personal computer(PC). The calculated result is generated through a LADOMi(Localization Auditory Display with Opened ear-canal for Mixed Reality). The HRTFs used in the experiment were measured for each listener with loudspeakers constantly 1.5m away from the center of the listener' s head in an anechoic room. To evaluate the system performance, we experimented a search task of a sound source position in the condition that the listener is able to move all around the room freely. As a result, the positioning error of presented sound source was within 30cm in average for all listeners.

Development of the Control Algorithm for Counterpulsation between a Moving-actuator type Bi-Ventricular Assist Device (AnyHeart) and a Natural Heart (한국형 심실 보조 인공심장과 자연심장 간의 counterpulsation 제어 알고리즘의 개발)

  • Nam, Kyoung Won;Choi, Seong Wook;Chung, Jinhan;Kim, Wook Eun;Min, Byoung Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.33-38
    • /
    • 2002
  • A Ventricular Assist Device(YAD) is used to support the injured natural heart So. when considering a control algorithm for YAD. it is important to reduce a natural heart's load to enhance its recovery condition. To reduce natural heart's load, a counterpulsation algorithm is used commonly. In this study, we developed a counterpulsation control algorithm for moving-actuator type VAD and tested its usefulness using in vitro MOCK circulatory system. To notice a natural heart's Pumping status, electrocardiogram(ECG) signal was used and as a result of test. the counterpulsation effect between YAD and a natural heart was occurred and Automatic Control Mode Transition was occurred properly.

Implementation of Adaptive Multi Rate (AMR) Vocoder for the Asynchronous IMT-2000 Mobile ASIC (IMT-2000 비동기식 단말기용 ASIC을 위한 적응형 다중 비트율 (AMR) 보코더의 구현)

  • 변경진;최민석;한민수;김경수
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.56-61
    • /
    • 2001
  • This paper presents the real-time implementation of an AMR (Adaptive Multi Rate) vocoder which is included in the asynchronous International Mobile Telecommunication (IMT)-2000 mobile ASIC. The implemented AMR vocoder is a multi-rate coder with 8 modes operating at bit rates from 12.2kbps down to 4.75kbps. Not only the encoder and the decoder as basic functions of the vocoder are implemented, but VAD (Voice Activity Detection), SCR (Source Controlled Rate) operation and frame structuring blocks for the system interface are also implemented in this vocoder. The DSP for AMR vocoder implementation is a 16bit fixed-point DSP which is based on the TeakLite core and consists of memory block, serial interface block, register files for the parallel interface with CPU, and interrupt control logic. Through the implementation, we reduce the maximum operating complexity to 24MIPS by efficiently managing the memory structure. The AMR vocoder is verified throughout all the test vectors provided by 3GPP, and stable operation in the real-time testing board is also proved.

  • PDF

Characteristics of Snowfall Event with Radar Analyses over Honam District and Gwangju Occurred by Cloud Streets over Yellow Sea for 04 Jan. 2003 (서해상에 발생하는 Cloud Streets에 동반된 2003년 1월 4일 강설의 레이더관측사례 분석)

  • Shin, Ki-Chang;Ryu, Chan-Su
    • Journal of Environmental Science International
    • /
    • v.19 no.10
    • /
    • pp.1187-1201
    • /
    • 2010
  • The formation and development conditions of the cloud streets over the yellow sea by the Cold Surge of Siberian Anticyclone Expansion which produce the heavy snowfall events over the southwestern coast, Honam District of the Korean peninsula, has been investigated through analyses of the three dimensional snow cloud structures by using the CAPPI, RHI, VAD and VVP data of X-band Radar at Muan Weather Observatory and S-band Radar at Jindo Weather Station. The data to be used are obtained from January 04, 2003, when heavy snow storm hits on Gwangju and Honam District. The PPI Radar images show that the cloud bands distribute in perpendicular to the expansion direction of the high pressure and that the radius of cloud cells is about 5~8 km with 20~30 dBz and distance between each cell is about 10 km. And but the vertical Radar images show that the cloud street is a small scale convective type cloud within height of about 3 km where a stable layer exists. From the VVP images, the time period of the high pressure expansion, the moving direction and development stages of the system are delineated. Finally, the vertical distribution of wind direction is fairly constants, while the wind speed sheer increases with altitude to 3 km.

A Study on Miniaturization of Digital Controller for both Implantable Total Artificial Heart (TAH) and Ventricular Assist Device (VAD) using PSD302 (PSD302를 이용한 완전 이식형 인공심장 및 심실보조장치 제어용 디지탈 콘트롤러 소형화에 관한 연구)

  • Lee, J.H.;Choi, J.H.;Lee, J.J.;Kim, W.E.;Om, K.S.;Choi, J.S.;Ahn, J.M.;Choi, W.W.;Park, S.K.;Cho, Y.H.;Kim, H.C.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.273-276
    • /
    • 1996
  • In the Total Artificial Heart (TAH) and Ventricular Assist Device (VAD), the size implanting the internal controller into human body is very serious problem. Hence, we need the size reduction of that controller for safe implantation. Using PSD302 chip for microcontroller-based applications, we could decrease the number of components in the digital control board and miniaturize the digital control board. We could replace a ROM, RAM, and a latch with that single chip, so the size of the newly developed board could be half the previous board.

  • PDF

Estimation of Ventricular Assist Device Outflow with the Pressures in Air Pressure Line (공압식 박동형 심실보조장치의 공압관 내 압력 측정을 통한 박출량 추정)

  • Kim, Young Il;Her, Keun;Kang, Seong Min;Choi, Seong Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.119-124
    • /
    • 2014
  • A Ventricular assist device (VAD) is one of the most efficient treatments to raise the survivability of the end stage heart failure patient. However, some of LVAD patients have died for the failures and improper control of LVAD. To detect critical dangers in LVAD, the monitoring methods of LVAD outflow have been requested, because it can be affected by patient's hemodynamic states and abnormal conditions of LVAD. In the case of an external pulsatile LVAD, the air movement through the air line can be used to estimate LVAD outflow. In this study, the air movement in the air-line of the extracorporeal pulsatile LVAD was measured with a differential pressure sensor between different points. The precise estimation of air movement could be achieved by additional measurement of air pressure. In a series of in-vitro experiments, the LVAD outflow were changed according to the afterload of LVAD and the differential pressure of LVAD didn't have close correlation with the LVAD outflow that were measured with an ultrasonic flowmeter at the same time. However, new precise estimation with the data from differential pressure and one point pressure in the air-line showed higher correlations with LVAD outflow.