• Title/Summary/Keyword: V2X modeling

Search Result 22, Processing Time 0.02 seconds

Dose Distribution and Characterization for Radiation Fields of Multileaf Collimateor System (방사선 입체조형치료용 다엽콜리메이터의 특성과 조직내 선량분포 측정)

  • Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.77-85
    • /
    • 1996
  • Purpose : Multileaf collimator(MLC) is very suitable tool for conformal radio-therapy and commissioning measurements for a multileaf collimator installed on a dual energy accelerator with 6 and 10MV photons are required, For modeling the collimator with treament planning software, detailed dosimetric characterization of the multileaf collimator including the penumbra width, leaf transmission between leaf leakage and localization of the leaf ends and sides is an essential requirement. materials and Methods : Measurement of characteristic data of the MLC with 26 pair block leaves installed on CLINAC 2100C linear accelerator was performed. Low sensitive radiographic film(X-omatV) was used for the penumbra measurement and separate experiments using radiographic film and thermoluminescent dosimeters were performed to verify the dose distribution, Measured films were analized with a photodensitometer of WP700i scanner. Results : For 6 & 10 MV x-ray energies, approximately $2.0\%$ of photons incident on the multileaf collimator were transmitted and an additional $0.5\%$ leakage occurs between the leaves. Localizing the physical end of the leaves showed less than 1mm deviation from the $50\%$ decrement line and this difference is attributed to the curved shaped end on the leaves One side of a sin히e leaf corresponded to the $50\%$ decrement line, but the opposite face was aligned with a lower value. This difference is due to the tongue and groove used to decrease between leaf leakage. Alignment of the leaves to form a straight edge resulted larger penumbra at far position from isocenter as compare with divergent alloy blocks. When the MLC edge is stepped by sloping field, the isodose lines follow the leaf pattern and Produce scalloping isodose curves in tissue. The effective penumbra by 45 degree stepped MLC is about 10mm at 10cm depth for 6MV x-ray. The difference of effective penumbra in deep tissue between MLC and divergent alloy blocks is small (5mm). Conclusion : Using the characteristic data of MLC, the MLC has the clinlical acceptability and suitability for 3-D conformal radiotherapy except small field size.

  • PDF

Pharmacokinetic Modeling of Reversible Interconversion between Prednisolone and Prednisone (가역적상호대사과정 모델을 이용한 Prednisolone과 Prednisone의 약동학적 분석)

  • Shin, Jae-Gook;Yoon, Young-Ran;Cha, In-June;Jang, In-Jin;Lee, Kyung-Hoon;Shin, Sang-Goo
    • The Korean Journal of Pharmacology
    • /
    • v.32 no.2
    • /
    • pp.269-281
    • /
    • 1996
  • Pharmacokinetics of prednisolone and prednisone undergoing reversible interconversion were analyzed from the model including this metabolic process. Blood samples were drawn serially upto 12 hours after I,V. bolus injection of 1 mg/kg prednisolone sodium phosphate and prednisone into 8 dogs as a crossover manner. Plasma concentrations of those two steroids were simultaneously measured with the method of HPLC. After injection, plasma concentrations of administered prednisolone and prednisone were declined with a biexponential pattern and their metabolic partner was rapidly formed. Plasma concentrations of those metaboite were decayed in parallel with their parent steroids throught the elimination phase. Apparent clearances of prednisolone and prednisone were $11.1{\pm}2.0\;ml/min/kg$ and $45.9{\pm}6.4\;ml/min/kg$, and they were underestimated by 29.4% and 33.6% compared to their real clearances$(15.7{\pm}4.4\;and\;69.2{\pm}17.7\;ml/min/kg)$ estimated using reversible interconversion model. Apparent volume of distribution of prednisolone$(1.32{\pm}0.43\;L/kg)$ and prednisone$(4.81{\pm}2.75\;L/kg)$ were overestimated by 53.5 and 52.7% and were compared to the real volumes $(0.86{\pm}0.30\;and\;3.15{\pm}2.13\;L/kg)$. Mean residence time of prednisolone$(2.0{\pm}0.61\;h)$ and prednisone$(1.74{\pm}0.74\;h)$ were much longer than the real sojourn time$(0.93{\pm}0.26\;and\;0.88{\pm}0.54\;h)$. Essential clearances In the reversible interconversion were greater as following orders: $Cl_{21}$(44.3 ml/min/kg) > $Cl_{20}$(24.2 ml/min/kg) > $Cl_{12}$ (7.9 ml/min/kg) > $Cl_{10}$(7.8 ml/min/kg). Estimated mean values of RF, EE, $%X^1_{ss}$ and $RHO^2_1$ were $0.31{\pm}0.10$, $1.49{\pm}0.23$, $69.3{\pm}16.7%$ and $0.65{\pm}0.10$, respectively. These results suggested that true pharmacokinetic parameters estimated from the model including reversible interconversion were significantly different from the apparent parameters estimated from the conventional mamillary model, and disposition of these two steroids seemed to be well explained by the model including reversible interconversion.

  • PDF