• Title/Summary/Keyword: V-t

Search Result 4,947, Processing Time 0.036 seconds

Vibrational Relaxation and Bond Dissociation in Methylpyrazine on Collision with N2 and O2

  • Young-Jin Yu;Sang Kwon Lee;Jongbaik Ree
    • Journal of the Korean Chemical Society
    • /
    • v.67 no.6
    • /
    • pp.407-414
    • /
    • 2023
  • The present study uses quasi-classical trajectory procedures to examine the vibrational relaxation and dissociation of the methyl and ring C-H bonds in excited methylpyrazine (MP) during collision with either N2 or O2. The energy-loss (-ΔE) of the excited MP is calculated as the total vibrational energy (ET) of MP is increased in the range of 5,000 to 40,000cm-1. The results indicate that the collision-induced vibrational relaxation of MP is not large, increasing gradually with increasing ET between 5,000 and 30,000 cm-1, but then decreasing with the further increase in ET. In both N2 and O2 collisions, the vibrational relaxation of MP occurs mainly via the vibration-to-translation (V→T) and vibration-to-vibration (V→V) energy transfer pathways, while the vibration-to-rotation (V→R) energy transfer pathway is negligible. In both collision systems, the V→T transfer shows a similar pattern and amount of energy loss in the ET range of 5,000 to 40,000cm-1, whereas the pattern and amount of energy transfer via the V→V pathway differs significantly between two collision systems. The collision-induced dissociation of the C-Hmethyl or C-Hring bond occurs when highly excited MP (65,000-72,000 cm-1) interacts with the ground-state N2 or O2. Here, the dissociation probability is low (10-4-10-1), but increases exponentially with increasing vibrational excitation. This can be interpreted as the intermolecular interaction below ET = 71,000 cm-1. By contrast, the bond dissociation above ET = 71,000 cm-1 is due to the intramolecular energy flow between the excited C-H bonds. The probability of C-Hmethyl dissociation is higher than that of C-Hring dissociation.

Correlation Effects in Superconducting $Sr_2VO_3FeAs$ (초전도 $Sr_2VO_3FeAs$에서 상관효과)

  • Lee, K.W.
    • Progress in Superconductivity
    • /
    • v.12 no.1
    • /
    • pp.46-50
    • /
    • 2010
  • In the superconducting $Sr_2VO_3FeAs$, containing bimetallic layers, with maximum $T_c{\approx}\;46\;K$ correlation effects on V ions have been investigated using LDA+U method. Within the local density approximation (LDA) this system has the one-third filled $t_{2g}$ manifold of V, decomposed into $d_{xy}$ of bandwidth W=2 eV and nearly degenerate $d_{zx}d_{yz}$ of W=1 eV. Consideration of correlation effects leads to a metal-insulator transition on V ions $t^{2\uparrow}_{2g}\;{\rightarrow}\;d^{1\uparrow}_{xz}\;d^{1\uparrow}_{yz}$ at the critical on-site Coulomb repulsion $U_c$= 3.5 eV. At U=4 eV, the electronic structure, in which V ions are insulating, leads to several van Hove singularities near $E_F$ and similar Fermiology with other pnictides. Applying U to V ions results in increasing Fe moment as well as V moment, indicating somewhat hybridization between Fe and V ions even though this system is strongly 2-dimesional. Our results show possible importance of correlation effects on this system.

Consolidation Behavior of Soft Ground by Prefabricated Vertical Drains (연직드레인 공법에 의한 연약지반의 압밀거동)

  • 이달원;강예묵
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.376-381
    • /
    • 1998
  • The large scaled field test by prefabricated vertical drains was performed to evaluate the superiority of vertical discharge capacity for drain materials through compare and analyze the time-settlement behavior with drain spacing and the compression index and consolidation coefficient obtained by laboratory experiments and field monitoring system 1. The relation of measurement settlement( $S_{m}$) versus design settlement( $S_{t}$) and measurement consolidation ratio( $U_{m}$) versus design consolidation ratio( $U_{t}$) were shown $S_{m}$=(1.0~l.1) $S_{t}$, $U_{m}$=(1.13~l.17) $U_{t}$, at 1.0m drain spacing and $S_{m}$=(0.7~0.8) $S_{t}$, $U_{m}$=(0.92~0.99) $U_{t}$ at 1.5m drain spacing, respectively. 2. The relation of field compression index( $C_{cfield}$) and virgin compression index( $V_{cclab}$) was shown $C_{cfield}$=(1.0~1.2) $V_{cclab}$, But it was nearly same value when considered the error with determination method of virgin compression index and prediction method of total settlement. 3. field consolidation coefficient was larger than laboratory consolidation coefficient, and the consolidation coefficient ratio( $C_{h}$/ $C_{v}$) were $C_{h}$=(2.4 ~ 3.0) $C_{v}$. $C_{h}$=(3.5 ~ 4.3) $C_{v}$ at 1.0m and 1.5m drain spacing and increased with increasing of drain spacingngasing of drain spacingng spacingng

  • PDF

A Study on the Midwater pair Trawling-III (쌍끌이 중층트롤어업의 연구 ( III ) - 끌줄의 예망장력에 관하여 - ( A Study on the Midwater Pair Trawling ( III ) ))

  • Jang, Choong-Sik;Lee, Byoug-Gee
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.32 no.1
    • /
    • pp.1-6
    • /
    • 1996
  • Towing tension of the model nets were determined by the load cell(O~20kg, 20DBBP) in front of W$T_mA$ = 1.57 . $V^1.86$ (unit: kg, mlsec) $T_mB$= 1.58 . $V^1.90$ 2. The towing tension of the full scale net was almost coincided with the results obtained by the model experiment. The towing tension(T) can be expressed as a function of the towing veJocity(V) as T=479$V^1.75$(unit: kg, k't)

  • PDF

A study on the ice and snow loading condition in Taebaek and Sabuk area in Gangwon province for the construction of KEPCO 765kV transmission lines (한전 765 kV 송전선로 건설을 위한 강원도 태백.사북지역 착빙설 하중조건 검토)

  • Park, K.H.;Kim, Y.W.;Won, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1923-1924
    • /
    • 1996
  • Some part of the route in KEPCO 765kV transmission line being constructed passes through a high mountain area which is 800m above the sea level (Taebaek, Sabuk area in Gangwon province). This area is the top part of Taebaek mountains corresponding to the backbone of korean peninsula and has lots of snow during the winter season because the winter seasonal wind gone up along the mountainside of Taebaek Mts. meets open air of the East sea. KEPCO has experienced 63 faults of T/L between 1968 and 1993 in this area, which is a very serious problem. Especially 154kV Hwang-Ji T/L fault in 1990, 2 was a unprecedented case which needs to be analyzed carefully to take proper measures. After reviewing ice and snow loading conditions and analyzing the fault of Hwang-Ji T/L, we're going to determine the revisement of ice and snow loading condition in this area to increase reliability of 765kV transmission line.

  • PDF

Development of Site Classification System and Modification of Design Response Spectra considering Geotechnical Site Characteristics in Korea (II) - Development of Site Classification System (국내 지반특성에 적합한 지반분류 방법 및 설계응답스펙트럼 개선에 대한 연구 (II) - 지반분류 개선방법)

  • Yoon, Jong-Ku;Kim, Dong-Soo;Bang, Eun-Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.2 s.48
    • /
    • pp.51-62
    • /
    • 2006
  • In the companion paper (I-Problem Statements of the Current Seismic Design Code), the current Korean seismic design code is required to be modified considering site characteristics in Korea for the reliable estimation of site amplification. In this paper, three site classification methods based on the mean shear wave velocity of the top 30m $V_{S30}$, fundamental site periods $(T_G)$ and bedrock depth were investigated and compared with each other to determine the best classification system. Not enough of a difference in the standard deviation of site coefficients $(F_a\;and\;F_v)$ to determine the best system, and neither is the difference between the average spectral accelerations and the design response spectrum of each system. However, the amplification range of RRS values based on $T_G$ were definitely concentrated on a narrow band than other classification system. It means that sites which have a similar behavior during earthquake will be classified as the same site category at the site classification system based on $T_G$. The regression curves between site coefficients and $T_G$ described the effect of soil non linearity well as the rock shaking intensity increases than the current method based on $V_{S30}$. Furthermore, it is unambiguous to determine sue category based on $T_G$ when the site investigation is performed to shallower depth less than 30m, whereas the current $V_{S30}$ is usually calculated fallaciously by extrapolating the $V_s$ of bedrock to 30m. From the results of this study, new site classification system based on $T_G$ was recommended for legions of shallow bedrock depth in Korea.

Fabrication and characteristics of SSIMT using a CMOS Process (CMOS공정에 의한 SSIMT의 제작 및 특성)

  • 송윤귀;임재환;정귀상;김남호;류지구
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.168-171
    • /
    • 2002
  • A SSIMT(Suppressed Sidewall Injection Magnetotransistor) sensor with high linearity is presented in this thesis. The prototype is fabricated by using the Hynix 0.6$\mu\textrm{m}$ P-substrate twin-well double poly three-metal CMOS Process. The fabricated SSIMT shows that variation of the collector current is extremely linear by varing the magnetic induction from -200mT to 200mT at I$\_$B/=500${\mu}$A, V$\_$CE/=2V and V$\_$SUB/=5V. The relative sensitivity is up to 120%/T. At B = 0, magnetic offset is about 79mT, there relative sensitivity is 30.5%/T. The nonlinearity of the fabricated SSIMT is measured about 1.4%.

  • PDF

A study on the mechanical strength system and supporting method of insulator strings for KEPCO 765kV transmission lines (한전 765 kV 송전선로 애자장치 강도계열 및 지지방식에 관한 검토)

  • Han, Yup;Park, K.H.;Yoon, S.H.;Seo, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1920-1922
    • /
    • 1996
  • After determining the type and string condition of conductor of 765kV transmission lines, we studied the mechanical strength system of insulator strings to support conductors and insulate conductors from towers. In this paper, for the insulator strings which will be used in 765kV transmission lines, we're going to optimally determine the mechanical strength system and supporting method in the consideration of the reliability, economics and the survey data of T/L routes, and also suggest the calculation method to stipulate for the application limits of suspension and strain insulator strings according to the loadspan and height difference of tower.

  • PDF

ON ALMOST PSEUDO-VALUATION DOMAINS, II

  • Chang, Gyu Whan
    • Korean Journal of Mathematics
    • /
    • v.19 no.4
    • /
    • pp.343-349
    • /
    • 2011
  • Let D be an integral domain, $D^w$ be the $w$-integral closure of D, X be an indeterminate over D, and $N_v=\{f{\in}D[X]{\mid}c(f)_v=D\}$. In this paper, we introduce the concept of $t$-locally APVD. We show that D is a $t$-locally APVD and a UMT-domain if and only if D is a $t$-locally APVD and $D^w$ is a $PvMD$, if and only if D[X] is a $t$-locally APVD, if and only if $D[X]_{N_v}$ is a locally APVD.

Temperature Dependence of Electrical Characteristics of AIGaAs/GaAs Heterojunction Bipolar Transistors (AIGaAs/GaAs 이종접합 바이폴라 트랜지스터의 온도 변화에 따른 전기적 특성에 대한 연구)

  • 박문평;이태우;김일호;박성호;편광의
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.349-352
    • /
    • 1996
  • When the ideality factor of collector current of AIGaAs/GaAs Heterojunction Bipolar Transistors (HBTs) is larger than unity, conventional $I_{CO}$ / $T^2$ versus 1000/T plot used in the determination of the barrier height of base-emitter junction of HBT was deviated from the straight line. We introduced the effective temperature $T_{eff}$ as nT in the Thermionic-emission equation. The modified $I_{CO}$ /TB versus 1000/ $T_{eff}$ plot was on the straight line in the temperature range considered. The activation energy obtained from the modified plot is 1.61 eV. The conduction band discontinuity calculated using this value was 0.305 eV and this value is coincident with the generally accepted value of 0.3 eV. eV.

  • PDF