• 제목/요약/키워드: V-shape tube

검색결과 25건 처리시간 0.019초

Contribution of Scattered X Rays to Signal Imaging with Anti-scatter Grids

  • Maeda, Koji;Arimura, Hidetaka;Morikawa, Kaoru;Kanamori, Hitoshi;Matsumoto, Masao
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.404-406
    • /
    • 2002
  • We have investigated the contribution of the scattered x rays to the signal imaging in the radiographs acquired with anti-scatter grids of several grid ratios by separating the line spread functions (LSFs) derived from the signal edge image into the primary and the scatter components. By using a 1.0-mm lead plate in the scattering material, the blurred signal edge images were acquired by use of an imaging plate at a tube voltage of 80 kV with the anti-scatter grids of grid ratios for 5:1, 6:1, 8:1, 10:1 and 12:1. The edge profiles of the signal images were scanned and those in relative exposure were differentiated to obtain the LSFs. To investigate the contribution of the scattered x rays to the signal imaging, we proposed a method for separating the LSFs derived from the signal images into the primary and the scatter components, where the scatter component was approximated with exponential function. Our basic approach is to separate the area of the LSFs by ratios of the scattered x-ray exposure to the primary x-ray exposure, which were obtained for the grid ratios by use of a lead disk method. The LSFs and the two components were Fourier transformed to obtain the modulation transfer functions (MTFs) and their two components. As the result, we found that, by using the anti-scatter grids, the scattered x rays were reduced, but the shape of the LSFs of the scatter component hardly changed. The contributions of the scatter component to the MTFs were not negligible (more than 10 %) for spatial frequencies lower than about 1.0 mm$\^$-l/ and that was greater as the grid ratio decreasing. On the other hand, for higher frequencies, the primary component was dominant compared with the scatter component.

  • PDF

대기압 마이크로웨이브 플라즈마를 이용한 다양한 크기의 ZnO tetrapod 합성 및 광촉매 특성 평가 (Synthesis of size-controlled ZnO tetrapods sizes using atmospheric microwave plasma system and evaluation of its photocatalytic property)

  • 허성규;정구환
    • 한국표면공학회지
    • /
    • 제54권6호
    • /
    • pp.340-347
    • /
    • 2021
  • Among various metal oxide semiconductors, ZnO has an excellent electrical, optical properties with a wide bandgap of 3.3 eV. It can be applied as a photocatalytic material due to its high absorption rate along with physical and chemical stability to UV light. In addition, it is important to control the morphology of ZnO because the size and shape of the ZnO make difference in physical properties. In this paper, we demonstrate synthesis of size-controlled ZnO tetrapods using an atmospheric pressure plasma system. A micro-sized Zn spherical powder was continuously introduced in the plume of the atmospheric plasma jet ignited with mixture of oxygen and nitrogen. The effect of plasma power and collection sites on ZnO nanostructure was investigated. After the plasma discharge for 10 min, the produced materials deposited inside the 60-cm-long quartz tube were obtained with respect to the distance from the plume. According to the SEM analysis, all the synthesized nanoparticles were found to be ZnO tetrapods ranging from 100 to 600-nm-diameter depending on both applied power and collection site. The photocatalytic efficiency was evaluated by color change of methylene blue solution using UV-Vis spectroscopy. The photocatalytic activity increased with the increase of (101) and (100) plane in ZnO tetrapods, which is caused by enhanced chemical effects of plasma process.

250 m 급 Bi-2223/Ag 고온 초전도선재 제조 (Fabrication of 250 m class Bi-2223/Ag HTS Tapes)

  • 하홍수;오상수;하동우;장현만;김상철;송규정;박찬;권영길;류강식
    • Progress in Superconductivity
    • /
    • 제3권1호
    • /
    • pp.130-133
    • /
    • 2001
  • A multifilamentary Bi-2223 HTS tape for superconducting power applications was studied through the fabrication of 250-meter long tapes by the PIT(powder in tube) process. To fabricate continuous long wire, a drawing machine, a two-drum bull block and a rolled tape winding machine were developed. Especially, 250-meter long tapes were heat treated in the shape of pancake coil to reduce the heat affect zone and to achieve the high critical current. Engineering critical current density was improved through both the enhancements of critical current density by control of thermal process and the increase of filling factor by using thin Ag alloy sheath tubes less than 1.5 mm in thickness. We have made successfully 250-meter long 37 filamentary tapes with high filling factor up to 31 % employing the modified drawing and rolling technique. The critical current of 250-meter long tapes with pancake coil type was measured by transport method at self-field up to 250 gauss of center field. The measured values, based on the transport critical current at self-field, $I_{c}$ -B characteristics and magnetic field analysis, are 34 A of I$_{c}$ and 4.0 $kA/\textrm{cm}^2$ of $J_{e}$ at 250 m, 77 K, and 0 T. We also have achieved the 56 A of I$_{c}$ and 7.0 $0 kA/\textrm{cm}^2$ of$ J_{e}$ in short tapes at 77K, self-field, and 1$mutextrm{V}$/cm.

  • PDF

전산화 치료계획의 CT/MRI 영상 융합 시 PLANNING MRI영상 획득의 유용성 평가 (USABILITY EVALUATION OF PLANNING MRI ACQUISITION WHEN CT/MRI FUSION OF COMPUTERIZED TREATMENT PLAN)

  • 박도근;최병기;김진만;이동훈;송기원;박영환
    • 대한방사선치료학회지
    • /
    • 제26권1호
    • /
    • pp.127-135
    • /
    • 2014
  • 목 적 : 전립선 암의 방사선 치료 시 컴퓨터 단층촬영 영상만을 이용하여 타겟 및 정상장기의 체적을 정의하기에는 제약성이 따른다. 이러한 제약성을 보완해주기 위하여 연부조직 대조도가 우수한 자기공명영상 장치가 사용되고 있다. 그러나 부정확한 CT/MRI 영상의 융합은 정확한 타겟 설정에 불확실성이 따르게 되며 정상장기의 불필요한 선량이 입사되어 부작용을 초래 할 수 있다. 이러한 불확실성을 줄이기 위해 본원에서는 CT/MRI영상 융합 시 모의 치료 과정과 동일한 고정용구와 자세로 환자를 셋업하여 MRI(Planning MRI)영상을 획득하고 있으며, 본 연구에서는 진단용 MRI영상과 Planning MRI영상을 비교 분석하여 Planning MRI의 유용성을 평가하고자 한다. 대상 및 방법 : 본원에서 2011년 8월부터 2013년 7월까지 전립선 암으로 진단을 받고 Non-hormone, Definitive RT 70 Gy/28 fx을 처방받은 10명의 환자를 대상으로 하였다. 모의 치료 후 30분 뒤에 MRI영상을 획득하였으며, 획득 된 CT/MRI영상은 뼈를 중심으로 Philips pinnacle v9.2를 이용하여 융합하였다. 전립선 Balloon tube의 유무에 따른 전립선의 변화를 측정하기 위하여 Planning MRI, 진단용 MRI영상에서의 전립선 체적을 측정 비교하였으며, 각각의 영상에서 전립선의 모양의 변화를 측정하기 위해 전립선의 중심에서 상하, 앞뒤, 좌우방향에서의 직경을 측정 비교하였다. 결 과 : Planning MRI, 진단용 MRI영상에서의 전립선 체적을 비교한 결과 각각 평균 $25.01cm^3$(범위 $15.84-34.75cm^3$), $25.05cm^3$(범위 $15.28-35.88cm^3$)의 결과를 얻었다. Planning MRI 대비 진단용 MRI는 0.12 % 증가로 그 차이는 크지 않다는 것을 알 수가 있었다. 하지만 Planning MRI를 기준으로 Transition zone 방향으로 총 $7.46cm^3$(29 %) 체적의 증가가 있었으며, Peripheral zone 방향으로 $8.52cm^3$(34 %)의 체적 감소가 있었다. 전립선 중심의 2차원 영상에서의 상하, 앞뒤, 좌우방향의 직경을 측정한 결과 Planning MRI에서 평균 3.82cm, 2.38cm, 4.59cm의 값을 나타냈으며, 진단용 MRI에서는 평균 3.37cm, 2.76cm, 4.51cm의 값을 알 수 있었다. Planning MRI 기준으로 앞뒤 방향으로 0.38cm(13 %)감소하였으나 좌우 방향 0.08cm(1.6 %), 상하방향 0.45cm(13 %)가 증가되었다. 결 론 : 본 연구의 결과를 바탕으로 Planning MRI와 진단용 MRI에서의 전립선의 총 체적은 큰 차이를 보이지 않았지만 직장에 전립선 Balloon tube 삽입으로 인한 전립선의 모양 및 부분 체적의 변화를 알 수가 있었다. 따라서 CT/MRI 영상 융합 시 Planning MRI영상을 이용한다면 진단용 MRI영상과 비교하여 Transition zone에 증가하는 체적만큼 손실 없이 타겟을 CTV에 포함시킬 수 있으며, Balloon으로 인한 Peripheral zone 체적의 감소를 더 명확히 구분하여 직장에 전달되는 방사선량을 줄일 수 있을 것이다. 이에 본 저자는 전산화 치료 계획에서의 CT/MRI영상 융합 시 모의 치료 과정과 동일한 고정용구와 자세를 재현하여 MRI영상을 획득하는 것이 유용할 것이라 사료된다.

Photon Knife 시스템에 근거한 뇌정위 방사선수술에서 표적위치 확인 (Verification of Target Position in Stereotactic Radiosurgery Based on Photon Knife System)

  • 최태진;김진희;김옥배
    • 한국의학물리학회지:의학물리
    • /
    • 제14권2호
    • /
    • pp.99-107
    • /
    • 2003
  • 선형가속기(Mitsubishi, ML15MDX)를 이용한 방사선수술시스템인 Photon Knife에서 Linac-gram을 통해 선속-표적 위치를 확인하여 신뢰성 있는 시술을 유지하도록 하였다. 선속-레이저광 교정 기구를 제작하여 레이저광의 입사점과 사출점을 조사하여 빔의 위치결정에 이용하였다. 선형가속기에 부착한 보조 콜리메이터의 고정을 확인하기 위해 Isocenter에서 5 cm 떨어진 위치에 팔각형 필름지지체를 두도록 제작하고 확인용 필름(Kodak X-omat V2)을 설치하였다. 필름에 선형가속기의 지지체를 45$^{\circ}$씩 회전조사 하여 필름에 나타난 거리로 보조 콜리메이터의 이동을 확인한 결과 실험 오차내에서 이동이 없음을 확인하였다. 임상에 이용한 체위 표시기는 10 mm 쇠구슬 제도와 납인형을 두어 PKRS 시술시 환부의 체위를 쉽게 확인할 수 있도록 고안제작되었다. 앙와위 및 우측 측와위로 조사한 방사선수술에서 표적 위치기에 있는 양측 쇠구슬과 콜리메이터 조사면과의 일치를 LINAC-gram에서 확인한 결과 CT 영상의 표적좌표와 비교해서 평균 0.8$\pm$0.26 mm 의 오차범위에서 시술하였음을 보이므로 방사선조사의 정확성을 알 수 있다. 선형가속기의 Couch 에 임의의 힘을 가했을 때 위치변동은 좌우 $\pm$5 mm, Couch 축방향으로 $\pm$1 mm, 상하로 $\pm$2 mm 이동할 수 있음을 확인하였다. 이상의 결과로 Photon knife 방사선 수술 시스템은 방사선수술 전 환부의 표적과 선속의 일치를 LINAC-gram을 통해 확인할 수 있어 시술의 신뢰도를 높일 수 있을 것으로 생각된다.

  • PDF