• Title/Summary/Keyword: V-cracks

Search Result 179, Processing Time 0.022 seconds

Interaction between two neighboring tunnel using PFC2D

  • Sarfarazi, V.;Haeri, Hadi;Safavi, Salman;Marji, Mohammad Fatehi;Zhu, Zheming
    • Structural Engineering and Mechanics
    • /
    • v.71 no.1
    • /
    • pp.77-87
    • /
    • 2019
  • In this paper, the interaction between two neighboring tunnel has been investigated using PFC2D. For this purpose, firstly calibration of PFC was performed using Brazilian experimental test. Secondly, various configuration of two neighboring tunnel was prepared and tested by biaxial test. The maximum and minimum principle stresses were 0.2 and 30 MPa respectively. The modeling results show that in most cases, the tensile cracks are dominant mode of cracks that occurred in the model. With increasing the diameter of internal circle, number of cracks decreases in rock pillar also number of total cracks decreases in the model. The rock pillar was heavily broken when its width was too small. In fixed quarter size of tunnel, the crack initiation stress decreases with increasing the central tunnel diameter. In fixed central tunnel size, the crack initiation stress decreases with increasing the quarter size of tunnel.

Improvement of Signal Processing Circuit for Inspecting Cracks on the Express Train Wheel (고속 신호처리 회로에 의한 고속철도 차륜검사)

  • Hwang, Ji-Seong;Lee, Jin-Yi;Kwon, Suk-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.579-584
    • /
    • 2008
  • A novel nondestructive testing (NDT) system, which is able to detect a crack with high speed and high spatial resolution, is urgently required for inspecting small cracks on express train wheels. This paper proposes an improved signal processing circuits, which uses the multiple amplifying circuits and the crack indicating pulse output system of the previous scan-type magnetic camera. Hall sensors are arrayed linearly, and the wheel is rotated with static speed in the vertical direction to sensor array direction. Each Hall voltages are amplified, converted and immediately operated by using, amplifying circuits, analog-to-digital converters and $\mu$-processor, respectively. The operated results, ${\partial}V_H/{\partial}t$, are compared with a standard value, which indicates a crack existence. If the ${\partial}V_H/{\partial}t$ is larger than standard value, the pulse signal is output, and indicates the existence of crack. The effectiveness of the novel method was verified by examine using cracks on the wheel specimen model.

  • PDF

TBM disc cutter ring type adaptability and rock-breaking efficiency: Numerical modeling and case study

  • Xiaokang Shao;Yusheng Jiang;Zongyuan Zhu;Zhiyong Yang;Zhenyong Wang;Jinguo Cheng;Quanwei Liu
    • Geomechanics and Engineering
    • /
    • v.34 no.1
    • /
    • pp.103-113
    • /
    • 2023
  • This study focused on understanding the relationship between the design of a tunnel boring machine disc cutter ring and its rock-breaking efficiency, as well as the applicable conditions of different cutter ring types. The discrete element method was used to establish a numerical model of the rock-breaking process using disc cutters with different ring types to reveal the development of rock damage cracks and variation in cutter penetration load. The calculation results indicate that a sharp-edged (V-shaped) disc cutter penetrates a rock mass to a given depth with the lowest load, resulting in more intermediate cracks and few lateral cracks, which leads to difficulty in crack combination. Furthermore, the poor wear resistance of a conventional V-shaped cutter can lead to an exponential increase in the penetration load after cutter ring wear. In contrast, constant-cross-section (CCS) disc cutters have the highest quantity of crack extensions after penetrating rock, but also require the highest penetration loads. An arch-edged (U-shaped) disc cutter is more moderate than the aforementioned types with sufficient intermediate and lateral crack propagation after cutting into rock under a suitable penetration load. Additionally, we found that the cutter ring wedge angle and edge width heavily influence cutter rock-breaking efficiency and that a disc cutter with a 16 to 22 mm edge width and 20° to 30° wedge angle exhibits high performance. Compared to V-shaped and U-shaped cutters, the CCS cutter is more suitable for soft or medium-strength rocks, where the penetration load is relatively small. Additionally, two typical case studies were selected to verify that replacing a CCS cutter with a U-shaped or optimized V-shaped disc cutter can increase cutting efficiency when encountering hard rocks.

Effects of number and angle of T Shape non persistent cracks on the failure behavior of samples under UCS test

  • Sarfarazi, V.;Asgari, K.;Maroof, S.;Fattahi, Sh
    • Computers and Concrete
    • /
    • v.29 no.1
    • /
    • pp.31-45
    • /
    • 2022
  • Experimental and numerical simulation were used to investigate the effects of angle and number of T shape non-persistent crack on the shear behaviour of crack's bridge area under uniaxial compressive test. concrete samples with dimension of 150 mm×150 mm×40 mm were prepared. Within the specimen, T shape non-persistent notches were provided. 16 different configuration systems were prepared for T shape non-persistent crack based on two and three cracks. In these configurations, the length of cracks were taken as 4 cm and 2 cm based on the cracks configuration systems. The angle of larger crack related to horizontal axis was 0°, 30°, 60° and 90°. Similar to cracks configuration systems in the experimental tests, 28 models with different T shape non-persistent crack angle were prepared in numerical model. The length of cracks were taken as 4 cm and 2 cm based on the cracks configuration systems. The angle of larger crack related to horizontal axis was 0°, 15°, 30°, 45°, 60°, 75° and 90°. Tensile strength of concrete was 1 MPa. The axial load was applied to the model. Displacement loading rate was controlled to 0.005 mm/s. Results indicated that the failure process was significantly controled by the T shape non-persistent crack angle and crack number. The compressive strengths of the specimens were related to the fracture pattern and failure mechanism of the discontinuities. Furthermore, it was shown that the compressive behaviour of discontinuities is related to the number of the induced tensile cracks which are increased by increasing the crack number and crack angle. The strength of samples decreased by increasing the crack number. In addition, the failure pattern and failure strength are similar in both methods i.e. the experimental testing and the numerical simulation methods (PFC2D).

Research on the Power Drop of Photovoltaic Module’s Aging Through the Thermal Shock Test

  • Kang, MinSoo;Jeon, YuJae;Kim, DoSeok;Shin, YoungEui
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.5
    • /
    • pp.268-273
    • /
    • 2015
  • While analyzing the specimens before and after the thermal shock test, we found that the power drop rate of the bare cell was 5.08%, while the power drop rate of the ribboned cell was 16.49%. In comparative terms, the efficiency was lower at the ribboned cell than at the bare cell. While analyzing through EL (Electroluminescence) shots and cross sections, we tried to decipher the exact cause of the power drop. Although mere color change of the cell was observed at the surface of the bare cell, no abnormality could be found inside the cell. On the surface of the ribboned cell, the short circuit of gridfinger extended from the front part of the front electrode of the ribboned cells. Therefore, cracks occurred on the surface of the cell. Cracks also appeared inside the cell. While analyzing the I-V curve, we determined an increase in the leakage current and an increase of resistances in series in the bare cell. In the ribboned cell, the resistances in parallel reduced remarkably. An increase of resistances in series could also be verified. Conclusively, we deduced that the power drop rate in the bare cell is a life span of the cell itself; aging is the cause of power drop rate in cells. In case of ribboned cell, the power drop rate was directly influenced by internal cracks and an intermetallic compound layer joining the ribbon at the front electrode.

Observation of Fatigue Crack Growth Behavior in 1Cr-1Mo-0.25V Steel Using Image Processing Technology (영상처리기법을 이용한 1Cr-1Mo-0.25V 강의 피로균열 성장거동 관찰)

  • Nahm, Seung-Hoon;Kim, Yong-Il;Ryu, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.1
    • /
    • pp.14-21
    • /
    • 2002
  • The development of a new experimental method is required to easily observe the growth behavior of fatigue cracks. To satisfy the requirement, an image processing technique was introduced to fatigue testing. The length of surface fatigue crack could be successfully measured by the image processing system. At first, the image data of cracks were stored into the computer while the cyclic loading was interrupted. After testing, crack length was determined using an image processing software which was developed by authors. Various image processing techniques like a block matching method was applied tc the detection of surface fatigue cracks. By comparing the data measured by the image processing system with those by the manual measurement with a microscope, the effectiveness of the image processing system was established. If the proposed method is used to monitor and observe the crack growth behavior automatically, the time and efforts for fatigue test could be dramatically reduced.

Inspection of Cracks on the Express Train Wheel Using a High Speed Scan Type Magnetic Camera (초고속 스캔형 자기카메라에 의한 고속열차 차륜 탐상)

  • Lee, Jin-Yi;Hwang, Ji-Seong;Kwon, Seok-Jin;Seo, Jung-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.11
    • /
    • pp.943-950
    • /
    • 2008
  • A novel nondestructive testing (NDT) system, which is able to detect a crack with high speed and high spatial resolution, is urgently required for inspecting small cracks on express train wheels. This paper proposes a high speed scan type magnetic camera, which uses the multiple amplifying circuits and the crack indicating pulse output system. The linearly integrated Hall sensors are arrayed in parallel, and the Hall voltages from each sensor in the scanning direction are obtained and amplified. High-speed NDT can be achieved by using the exclusive analog-digital converter and micro-processor because the ${\partial}\;V_H/\;{\partial}$ x value, which provides the most important crack information, can be obtained by buffering and calculating. The effectiveness of the novel method was verified by examine using cracks on the wheel specimen model.

Impact Toughness and Fracture Behavior in Non-Heat Treating Steels Containing Bainite (베이나이트 함유 비조질강의 충격인성 및 파괴거동)

  • Cho, Ki-Sub;Kwon, Hoon
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.32 no.4
    • /
    • pp.161-167
    • /
    • 2019
  • Impact toughness and fracture behavior were studied in five kinds of non-heat treating steels containing bainite; standard(0.25C-1.5Mn-0.5Cr-0.2Mo-0.15V), high V(0.3V), Ni(0.5Mn-2Ni), W(0.4W instead of Mo), and high C-Ni(0.35C-0.5Mn-2Ni) steels. The good hardness and impact toughness balance was exhibited in the $1100^{\circ}C$-rolled condition, while the impact toughness was deteriorated due to coarse grained microstructure in the $1200^{\circ}C$-rolled condition. The impact toughness decreased with increasing the hardness in all steels studied. The fracture behavior was also basically identical, that is, the fracture area was divided into 3 zones; shear and fibrous zone, fracture transition zone with ductile dimples and cleavage cracks, where the cracks initiate and grow to critical size, unstable cleavage fracture propagation zone. The energy absorbed for the critical crack formation through the plastic deformation inside the plastic zone in front of the notch root contributed to a mostly significant portion of the total impact energy.

Corrosion Quantification of Reinforcing Bar in Concrete Using Micro Computer Tomography (Micro-CT 활용 콘크리트 내 철근 부식 정량을 위한 실험적 연구)

  • Jang, In-Dong;Yi, Chong-Ku
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.252-253
    • /
    • 2019
  • Corrosion of rebars in reinforced concrete structures is a major factor that shortens the life of the structure. As corrosion progresses, the adhesion between the concrete tissues and the rebar decreases and the cracks in the concrete due to the expansion of the oxide intensify. Although it is necessary to measure corrosion behavior of rebars inside the concrete to measure degradation of structures due to rebar corrosion, no studies have been conducted to measure corrosion of rebars in In-situ state. In this study, corrosion of rebars in reinforced concrete specimens was attempted to be quantified using micro-computer tomography. Since corrosion of concrete takes several months per 10mm of cover, accelerated corrosion techniques were applied. Accelerated corrosion on the specimen was conducted by applying a 10 V magnetic field to the buried rebar and external electrodes with the specimen submerged in a 10% calcium chloride solution. The experiment found that within two weeks, more than 40% of rebar reduction occurred, and the cracks in the radial cracks occurred through the concrete structure, leading to the transfer of the oxide produced through the cracks to the surface of the specimen.

  • PDF

V-Factor Estimation Under Thermal and Mechanical Stress for Circumferentially Cracked Cylinder (열하중 및 기계하중이 작용하는 원주 방향 균열 배관에 대한 V-계수 평가)

  • Song, Tae-Kwang;Oh, Chang-Kyun;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.12
    • /
    • pp.1123-1131
    • /
    • 2008
  • This paper provides V-factor estimation under combined mechanical and thermal load for circumferential cracks. Results are based on finite element analyses and effect of types and magnitudes of the thermal stress, crack geometry, the loading mode and plastic strain hardening on variations of the V-factor are investigated. The results of finite element analyses are compared with R6 values. As a result, it is shown that R6 gives generally conservative results. The conservatism is especially increased for the combination of large mechanical and thermal load. As a result, new estimation method which uses failure assessment line in R6 is proposed for V-factor and gives less conservative results.