• Title/Summary/Keyword: V-bed

Search Result 239, Processing Time 0.028 seconds

Systematic Review and Comparative Meta-Analysis of Outcomes Following Pedicled Muscle versus Fasciocutaneous Flap Coverage for Complex Periprosthetic Wounds in Patients with Total Knee Arthroplasty

  • Economides, James M.;DeFazio, Michael V.;Golshani, Kayvon;Cinque, Mark;Anghel, Ersilia L.;Attinger, Christopher E.;Evans, Karen Kim
    • Archives of Plastic Surgery
    • /
    • v.44 no.2
    • /
    • pp.124-135
    • /
    • 2017
  • Background In cases of total knee arthroplasty (TKA) threatened by potential hardware exposure, flap-based reconstruction is indicated to provide durable coverage. Historically, muscle flaps were favored as they provide vascular tissue to an infected wound bed. However, data comparing the performance of muscle versus fasciocutaneous flaps are limited and reflect a lack of consensus regarding the optimal management of these wounds. The aim of this study was to compare the outcomes of muscle versus fasciocutaneous flaps following the salvage of compromised TKA. Methods A systematic search and meta-analysis were performed to identify patients with TKA who underwent either pedicled muscle or fasciocutaneous flap coverage of periprosthetic knee defects. Studies evaluating implant/limb salvage rates, ambulatory function, complications, and donor-site morbidity were included in the comparative analysis. Results A total of 18 articles, corresponding to 172 flaps (119 muscle flaps and 53 fasciocutaneous flaps) were reviewed. Rates of implant salvage (88.8% vs. 90.1%, P=0.05) and limb salvage (89.8% vs. 100%, P=0.14) were comparable in each cohort. While overall complication rates were similar (47.3% vs. 44%, P=0.78), the rates of persistent infection (16.4% vs. 0%, P=0.14) and recurrent infection (9.1% vs. 4%, P=0.94) tended to be higher in the muscle flap cohort. Notably, functional outcomes and ambulation rates were sparingly reported. Conclusions Rates of limb and prosthetic salvage were comparable following muscle or fasciocutaneous flap coverage of compromised TKA. The functional morbidity associated with muscle flap harvest, however, may support the use of fasciocutaneous flaps for coverage of these defects, particularly in young patients and/or high-performance athletes.

A Study of Development for High-speed Cloud Video Service using SDN based Multi Radio Access Technology Control Methods (초고속 클라우드 비디오 서비스 실현을 위한 SDN 기반의 다중 무선접속 기술 제어에 관한 연구)

  • Kim, Dongha;Lee, Sungwon
    • Journal of Broadcast Engineering
    • /
    • v.19 no.1
    • /
    • pp.14-23
    • /
    • 2014
  • This paper proposed controlling methods for SDN(Software Defined Network) based multiple radio access technology as the solutions of following two issues which were mainly occurred by explosive increasing of video traffic. The first one is a requirement for traffic off-loading caused by 3rd-party video service providers from the mobile network operator's viewpoint. The other one is a provision of high-speed video contents transmission services with low price. Furthermore, the performance evaluation was also conducted on the real test-bed which is composed of OpenStack cloud and SDN technology such as OpenFlow and Open vSwitch. A virtual machine running on the OpenStack provide a video service and the terminal which is able to use multiple radio access technology supports two 2.4GHz WLANs(Wireless Local Area Network) and three 5GHz WLANs, concurrently. Finally, we can get 820Mbps of the maximum transmission speed by using that five WLAN links for the single service at the same time.

A Study on the Change in Dietary Patterns of Some Elementary School Children in Seoul - concerning the Frequent Use of Computers - (서울지역 일부 초등학생의 식생활 양상 변화에 대한 연구 - 컴퓨터 사용을 중심으로 -)

  • 강영림;김애정
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.13 no.4
    • /
    • pp.284-292
    • /
    • 2003
  • This study was conducted to investigate the changes of dietary attitudes and behaviors in relation to the use of computers of elementary school children in Seoul. The total of 451 elementary school children, consisting of 235 females and 216 males, participated in the study. The result of domestic characteristics, dietary attitudes and behaviors, the level of the use of computers, and health-related symptoms of the subjects were achieved through the questionnaires as follows: The average height, weight, BMI and obesity-index of the participants were 149.0 cm, 42.4 kg, 19.0, -8.6, respectively. Anions subjects, 42.8% answered their bed times were between 11~12 pm, and 82.4% answered that they had extracurricular activities. The most desired activity as their leisure was computer works (female: 44.3%, male: 62.5%). 38.4% of children used the computers for 1~2 hours a day and the most general usage of computers was a computer game (66.1%). The changes in dietary habits of the subjects were such as eating faster(30.2%), having lots of snacks(28.8%), eating anything at hand(26.4%), skipping breakfast due to over-sleeping(18.4%). As changes in life patterns, those in the time managements for watching T.V.(35.3%), reading(35.0%), exercising(31.9%), sleeping(27.5%), relaxing(27.5%) and other hobbies(26.4%) were observed. In conclusion, many children were being affected by the socioeconomic factors changing the environments, especially by the need for the use of computers. The rates of eating alone and skipping breakfast were getting higher in the dietary patterns of elementary school children. We found that the changes in social environments according to the heavy use of the computer were affecting on their dietary pattern. The direction and method of nutrition education had to be established for the proper understanding of the desirable dietary behaviors.

  • PDF

Research Investigations at the Municipal (2×35) and Clinical (2×5 MW) Waste Incinerators in Sheffield, UK

  • Swithenbank, J.;Nasserzadeh, V.;Ewan, B.C.R.;Delay, I.;Lawrence, D.;Jones, B.
    • Clean Technology
    • /
    • v.2 no.2
    • /
    • pp.100-125
    • /
    • 1996
  • After recycle of spent materials has been optimised, there remains a proportion of waste which must be dealt with in the most environmentally friendly manner available. For materials such as municipal waste, clinical waste, toxic waste and special wastes such as tyres, incineration is often the most appropriate technology. The study of incineration must take a process system approach covering the following aspects: ${\bullet}$ Collection and blending of waste, ${\bullet}$ The two stage combustion process, ${\bullet}$ Quenching, scrubbing and polishing of the flue gases, ${\bullet}$ Dispersion of the flue gases and disposal of any solid or liquid effluent. The design of furnaces for the burning of a bed of material is being hampered by lack of an accurate mathematical model of the process and some semi-empirical correlations have to be used at present. The prediction of the incinerator gas phase flow is in a more advanced stage of development using computational fluid dynamics (CFD) analysis, although further validation data is still required. Unfortunately, it is not possible to scale down many aspects of waste incineration and tests on full scale incinerators are essencial. Thanks to a close relationship between SUWIC and Sheffield Heat&Power Ltd., an extended research programme has been carried out ar the Bernard Road Incinerator plant in Sheffield. This plant consists of two Municipal(35 MW) and two Clinical (5MW) Waste Incinerators which provide district heating for a large part of city. The heat is distributed as hot water to commercial, domestic ( >5000 dwelling) and industrial buildings through 30km of 14" pipes plus a smaller pipe distribution system. To improve the economics, a 6 MW generator is now being added to the system.

  • PDF

Mechanical Properties Characteristics according to Heat Treatment Conditions of Medical Bone Plates by 3D Printing (3D프린팅 제조기반 골절합용 금속판의 열처리 조건에 따른 기계적 성능 특성)

  • Jung, Hyunwoo;Park, Sung Jun;Woo, Heon
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.116-123
    • /
    • 2022
  • This study analyzes the Mechanical properties of a medical bone plate by 3D printing. With the recent development of 3D printing technology, it is being applied in various fields. In particular, in the medical field, the use of 3D printing technology, which was limited to the existing orthosis and surgical simulation, has recently been used to replacement bones lost due to orthopedic implants using metal 3D printing. The field of application is increasing, such as replacement. However, due to the manufacturing characteristics of 3D printing, micro pores are generated inside the metal printing output, and it is necessary to reduce the pores and the loss of mechanical properties through post-processing such as heat treatment. Accordingly, the purpose of this study is to analyze the change in mechanical performance characteristics of medical metal plates manufactured by metal 3D printing under various conditions and to find efficient metal printing results. The specimen to be used in the experiment is a metal plate for trauma fixation applied to the human phalanx, and it was manufactured using the 'DMP Flex 100(3D Systems, USA), a metal 3D printer of DMLS (Direct Metal Laser Sintering) method. It was manufactured using the PBF(Powder Bed Fusion) method using Ti6Al4V ELI powder material.

Intraoperative Radiotherapy for Resectable Pancreatic Cancer Using a Low-Energy X-Ray Source: Postoperative Complications and Early Outcomes

  • Yeona Cho;Jun Won Kim;Hyung Sun Kim;Joon Seong Park;Ik Jae Lee
    • Yonsei Medical Journal
    • /
    • v.63 no.5
    • /
    • pp.405-412
    • /
    • 2022
  • Purpose We evaluated the safety, feasibility, and early treatment outcomes of intraoperative radiotherapy (IORT) using a low-energy X-ray source. Materials and Methods Patients with resectable pancreatic cancer were enrolled in this single-institution, prospective, single-arm, phase II trial. Patients underwent surgery and IORT with 10 Gy prescribed at a 5-mm depth from the tumor bed using a 50 kV X-ray source (Intrabeam, Carl Zeiss). Six cycles of adjuvant gemcitabine-based chemotherapy were administered 8-12 weeks after surgery. Results A total of 41 patients were included. Thirty-one patients (75.6%) underwent wide R0 resection, while 5 (12.2%) underwent R1 resection and 5 (12.2%) underwent narrow R0 resection (retroperitoneal margin <1 mm). Grade 3 postoperative complications were reported in only one patient (4.9%) who needed additional surgery due to ulcer perforation. At a median follow-up of 9 months, four patients showed local-only recurrence, nine had distant metastases, and two showed both local and distant recurrence. The 1-year local control rate was 76.4%. Conclusion Our preliminary report suggests that IORT is well-tolerated and feasible in patients with resectable pancreatic cancer. Further follow-up is needed to confirm the clinical benefits of IORT in terms of local control and overall survival. Trial Registration: Clinical trial registration No. (NCT03273374).

A study on the Development of a Drying and Fermentation Process of Domestic Animal Manure;II. Demonstration of a Pig Manure Treatment System on a Farm (가축분(家畜糞) 건조(乾燥) , 발효(醱酵) 복합시설(複合施設) 개발(開發) 연구(硏究);II. 돈분(豚糞) 건조(乾燥), 발효(醱酵), 복합시설(複合施設) 실증시험(實證試驗))

  • Yun, Sun-Gang;Jung, Kwang-Yong;Park, Woo-Kun;Kwon, Sun-Ik;Park, Hong-Jae;Yoo, Sun-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.13 no.2
    • /
    • pp.223-230
    • /
    • 1994
  • A practical study on a drying and fermentation system equipped with a stirring machine operated mechanically, of pig manure was conducted to prove the efficiency of and practicability to an ordinary pig farm. The type of the drying bed was a round-shaped (r=3m) concrete structure and the stirring machine was adopted to stir and transfer dried pig manure to the fermentation tank. The dried pig manure was put into a fermentation tank ($V=18m^3$), which was aerated from pipe lines installed at the bottom. While water content of pig manure passing through a drying bed was remarkably reduced than before drying, the drying efficiency of this system decreased in winter. However, the temperature of pig manure piled up in the fermentation room in winter reached over $60^{\circ}C$ and excess water of pig manure was removed during the fermentation process. The reduction rate of water content of pig manure, to which dried pig manure was added as bulking material on the drying bed, was 52.1%, but when dried without bulking material it was only 19.7%. Although the content of $P_2O_5$ of dried pig manure was slightly higher than that of fresh pig manure, progressive changes in chemical composition between fresh and dried pig manure made no great difference. Among the contents of minerals of fresh and dried pig manure, CaO was the highest and the rest were in the decreasing order of $K_2O$, MgO, and $Na_2O$. Population density of E. coli and Streptococci of dried pig manure was reduced by 142 and 236 times that of fresh pig manure, respectively. The installation cost of this drying and fermentation system was 4,185,630 won (approximately 5,232 US $) and operating cost per year was 190,000 won (237.5US $) on the basis of self-labor condition.

  • PDF

Performance Characteristics of Agitated Bed Manure Composting and Ammonia Removal from Composting Using Sawdust Biofiltration System (교반식 축분 퇴비화 및 톱밥 탈취처리 시스템의 퇴비화 암모니아 제거 성능)

  • Hong, J.H.;Park, K.J.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.1
    • /
    • pp.13-20
    • /
    • 2007
  • Sawdust biofiltration is an emerging bio-technology for control of ammonia emissions including compost odors from composting of biological wastes. Although sawdust is widely used as a medium for bulking agent in composting system and for microbial attachment in biofiltration systems, the performance of agitated bed composting and sawdust biofiltration are not well established. A pilot-scale composting of hog manure amended with sawdust and sawdust biofiltration systems for practical operation were investigated using aerated and agitated rectangular reactor with compost turner and sawdust biofilter operated under controlled conditions, each with a working capacity of approximately $40m^3\;and\;4.5m^3$ respectively. These were used to investigate the effect of compost temperature, seed germination rate and the C/N ratio of the compost on ammonia emissions, compost maturity and sawdust biofiltration performance. Temperature profiles showed that the material in three runs had been reached to temperature of 55 to $65^{\circ}C$ and above. The ammonia concentration in the exhaust gas of the sawdust biofilter media was below the maximum average value as 45 ppm. Seed germination rate levels of final compost was maintained from 70 to 93% and EC values of the finished compost varied between 2.8 and 4.8 ds/m, providing adequate conditions for plant growth.

  • PDF

Study on the Midwater Trawl Available in the Korean Waters ( V ) - Opening Efficiency of the Otter Board with a Large Float on the Top - (한국 근해에 있어서의 중층 트로올의 연구 ( V ) - 전개판에 대형 뜸을 달았을 때의 전개성능 -)

  • Lee, Byong-Gee;Kim, Min-Suk
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.24 no.2
    • /
    • pp.78-82
    • /
    • 1988
  • Near sea trawlers of Korea sometimes catch pelagic fishes like file fish by using midwater trawl gear even though usually catch bottom fish. It is reasonable to use the specific otter board as well as specific net in bottom trawling and in midwater trawling respectively. But, the trawlers are so small ranging 100 to 120GT, 700 to 100ps that it is very complicated to use different otter board for bottom trawling and for midwater trawling. The otter board for bottom trawling. is also used for the midwater trawling without any change even though the net is changed into the specific one. Although the otter board in the midwater trawling should be lighter than that for bottom trawling, to use otter board for bottom trawling directly for the midwater trawling without any change makes the net easily touch the sea bed and also make the horizontal opening of the otter boards be limited owing to the length of warp in the southern sea of Korea, main fishing ground of midwater trawling, which is 100m or so in depth. That is why the otter board for the midwater trawling should be made lighter than that in the bottom trawling, even if temporary. The authors carried out an experiment to achieve this purpose by attaching a large styropol float on the top of the otter board. In this experiment, underwater weight of the otter board was 630kg and buoyancy of the float was 510kg. To determine the depth and horizontal opening of the otter board, two fish finder was used. A transmitter of 50KHz fish finder was set downward through the shoe plate of otter board to determine the elevation of otter board from the sea bed, and a transmitter of 200KHz fish finder was set sideways on the starboard otter board to be able to detect the distance between otter boards. The obtained results can be summarized as follows: 1. The actual towing speed in the experiment varied 1.1 to 1.8 m/sec. 2. The depth of otter board was within 41 to 25m with float on the top and 45 to 26m without float in case of the warp length 100m, whereas the depth 68-44m with float and 74-46m without float in case of the warp length 150m. This fact means that the depth with float was 9-4% shallower than that without float. 3. The horizontal opening between otter boards was within 34-41m with float and 30-38m without float in case of the warp length 100m, whereas the opening was 44-50m with float and 37-46m without float in case of the warp length 150m. This fact means the opening with float was 10% greater than that without float in case of the warp length 100m, and 15% greater in case of the warp length 150m. 4. The horizontal opening between wing tips by using the otter board with float was 1m greater than by without float in case of the warp length 100m, whereas the opening by with float was 2m greater than by without float in case of warp length 150m. From this fact, it can be estimated that the effective opening area of the net mouth by using the otter board with float could be made 10% greater than by without float in case of warp length 100m, whereas the area with float 20% greater than by without float in case of warp length 150m.

  • PDF

Evaluation of Average CT to Reduce the Artifact in PET/CT (PET/CT 검사에서 호흡에 따른 인공산물을 줄이기 위한 Average CT의 유용성)

  • Kim, Jung-Sun;Nam, Ki-Pyo;Park, Seung-Yong;Ryu, Jae-Kwang;Cha, Min-Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.3-7
    • /
    • 2010
  • Purpose: The usefulness of Positron Emission Tomography (PET) images in diagnosis, staging, recurrent and treatment response evaluation has already been known. However, tumors which are small size, located in lower lobe of lung or upper lobe of liver are shown misalignment, distortion and different Standard Uptake Value (SUV) by respiration in PET images. Therefore, if radiotherapy based on normal respiration, it may cause low treatment response or more side effects because targets which had to treat, out of treat range or over dose to normal tissue. The purpose of this study is to evaluate attenuation-correction with Average CT (ACT) for more accuracy SUV measurement and minimize artifact by respiration. Materials and Methods: 13 patients, who had tumors which are around the diaphragm, underwent ACT scan after Helical CT (HCT) scan with PET/CT (Discovery DSTE 8; GE Healthcare). We quantified the differences between attenuation corrected image with HCT and attenuation corrected image with ACT in artifact size and maximum SUV ($SUV_{max}$). Artifacts were evaluated by measurement of the curved photogenic area in the lower thorax of the PET images for all patients. $SUV_{max}$ was measured separately at the primary tumors. Analysis program was Advantage Workstation v4.3 (GE Healthcare). Patients were injected with 7.4 MBq (0.2 $mC_i$) per kg of $^{18}F$-FDG and scanned 1 hour after injection. The PET acquisition was 3 minute per bed. Results: Significantly lower artifact were observed in PET/ACT images than in PET/HCT images (below-thoracic artifacts caused by under corrected $1.5{\pm}3.5$ cm vs. $13.4{\pm}4.2$ cm). Significantly higher $SUV_{max}$ were noted in PET/ACT images than in PET/HCT images in the primary tumor. Compared with PET/HCT images, $SUV_{max}$ in PET/ACT images were higher by $5.3{\pm}3.9%$ (mean value) tumor. The highest difference was observed in Lower lobe of lung (7.7 to 8.7; 13%). Conclusion: Due to its significantly reduced artifacts in lower thoracic, attenuation corrected image with ACT images provided more reliable $SUV_{max}$ and may be helpful in monitoring treatment response. Moreover, ACT can separate upper lobe of liver and lower lobe of lung, it may be helpful in interpretation. ACT will be clinically useful, considering increased dose caused by ACT scan and adapt.

  • PDF