• Title/Summary/Keyword: V² control

Search Result 4,917, Processing Time 0.035 seconds

Stability Improvement of a V/f Controlled Induction Motor Drive System using a Dynamic Current Compensator (다이나믹 전류보상기를 이용한 V/f 제어 유도전동기 드라이브 시스템의 안정도 향상)

  • 정강률
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.6
    • /
    • pp.402-408
    • /
    • 2004
  • This paper proposes the novel V/f control method to improve the stability of a V/f controlled induction motor drive system. The conventional V/f control method used in the proposed V/f control method is a vector-based method that is slightly different from the existing conventional V/f control method. The proposed control method uses a dynamic current compensator to improve the stability of a V/f controlled induction motor drive system. This proposed method is easy to implement and completely eliminates the motor oscillation phenomenon causing the instability of a V/f controlled induction motor drive system, especially when the system is driven near the resonant frequency in steady-state with light load. Additionally, this paper analyzes theoretically the instability of a V/f controlled induction motor drive system and shows the validity of the Proposed V/f control method through simulation and experimental results.

Control Methods for Aerosols and Airborne Spreading Theory of SARS-CoV-2 (사스-코로나바이러스-2 공기 중 부유 전파이론과 에어로졸 제어기술)

  • Lee, Byung Uk
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.2
    • /
    • pp.123-130
    • /
    • 2021
  • Objectives: Control methods against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) aerosols have been introduced. Airborne spreading theories for SARS-CoV-2 were analyzed in this study. Methods: Control methods for airborne microorganisms were discussed. Studies on theoretical estimations for airborne spreading of SARS-CoV-2 were presented and analyzed. Analytic calculations were conducted for explaining control techniques for airborne microorganisms. Results: Control methods for SARS-CoV-2 aerosols can include physical or biological procedures. Characterization of SARS-CoV-2 aerosols and massive clustering infection cases of COVID-19 support the airborne spreading theories of SARS-CoV-2. It is necessary to consider the disadvantages of control methods for airborne microorganisms. Conclusions: A study on control methods against bioaerosols is necessary to prevent the spreading of viruses. Airborne spreading theories of SARS-CoV-2 were supported by the current evidence, but further studies are needed to confirm these theories.

Stem Firmness and Flowering Response of Cut Lilies as Influenced by Medium Composition in Box Culture

  • Suh, Jeung-Keun
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2001.04b
    • /
    • pp.45-50
    • /
    • 2001
  • Stem firmness and flowering response of cut lily as influenced by medium composition (Control: Upland soil, Pt: Peatmoss, Pe: Perlite, Ve: Vermiculite, Rrh: Rotted rice-hull, RPt: Russian Peatmoss) were studied. For 'Casa Blanca', plant height and length of flower stalk increased when bulbs were planted in Pt:Rrh:Ve(1:1:1, v/v), and dried leaves of lower part plants decreased by RPt:Pe:Rrh(1:1:1, v/v). In case of 'Marco Polo' plant height and length of flower stalk increased with Pt:Rrh(1:1, v/v) as compared to other treatment, number of leaves and dried leaves increased when bulbs were planted in RPt:Pe:Rrh(1:1:1, v/v) as compared to control. Flowering of 'Casa Blanca' was promoted in Pt:Pe:Ve(1:1:1, v/v) and 'Marco Polo' was accelerated in Pt:Rrh:Ve(1:1:1, v/v). Flower length of 'Casa Blanca' was increased by RPt:Pe:Rrh(1 :1 :1, v/v) as compared with control and 'Marco Polo' was increased when bulbs planted to Pt:Rrh(1 :1, v/v). Flower-bud blasting of two cultivars was increased with Pt as compared with other treatment. Stem firmness of 'Casa Blanca' was increased by Pt:Pe:Ve (1:1 :1, v/v), and especially, stem firmness of upper part plants was increased by Pt:Rrh(1 :1, v/v) in 'Marco Polo' as compared to control plants. but generally, stem firmness of 'Casa Blanca' was not influenced with all cultural media as compared to control.

  • PDF

A Stable Startup Method of V/f Scalar Controlled Permanent Magnet Synchronous Motors (V/f 스칼라 제어 영구자석 동기 전동기의 안정적 초기 구동 기법)

  • Kim, Hyeon-Seong;Lee, Sang-Min;Lee, Kibok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.5
    • /
    • pp.395-403
    • /
    • 2020
  • This study presents a stable start-up strategy for v/f scalar-controlled permanent magnet synchronous motors (PMSMs). The v/f-controlled PMSMs easily lose synchronism under low-speed conditions if an insufficient stator voltage is applied to the machine due to errors in measured motor parameters and inverter nonlinearity, such as inverter dead time and on-state voltage drop. The proposed method adopts the I/f control method to ensure a stable start at low speeds and then switches to the v/f control method at medium speeds. A smooth transition method from I/f control to v/f control is proposed to minimize the oscillation of the stator current and rotor speed during transition. Moreover, the stability of the I/f and v/f control methods is analyzed using a small-signal model. Simulation and experimental results are provided to verify the performance of the proposed control strategy.

Efficient Interference Control Technology for Vehicular Moving Networks

  • Oh, Sung-Min;Lee, Changhee;Lee, Jeong-Hwan;Park, Ae-Soon;Shin, Jae Sheung
    • ETRI Journal
    • /
    • v.37 no.5
    • /
    • pp.867-876
    • /
    • 2015
  • This paper proposes an efficient interference control scheme for vehicular moving networks. The features of the proposed scheme are as follows: radio resources are separated into two resource groups to avoid interference between the cellular and vehicle-to-vehicle (V2V) links; V2V links are able to share the same radio resources for an improvement in the resource efficiency; and vehicles can adaptively adjust their transmission power according to the interference among the V2V links (based on the distributed power control (DPC) scheme derived using the network utility maximization method). The DPC scheme, which is the main feature of the proposed scheme, can improve both the reliability and data rate of a V2V link. Simulation results show that the DPC scheme improves the average signal-to-interference-plus-noise ratio of V2V links by more than 4 dB, and the sum data rate of the V2V links by 15% and 137% compared with conventional schemes.

Stem Firmness and Flowering Response of Cut Lilies as Influenced by Medium Composition in Box Culture (절화백합의 상자 재배시 몇가지 배양토 조성이 생육과 줄기경도에 미치는 영향)

  • Suh, Jeung-Keun
    • Journal of Bio-Environment Control
    • /
    • v.10 no.2
    • /
    • pp.75-79
    • /
    • 2001
  • Stem firmness and flowering response of cut lily as influenced by medium composition (Control; Upland soil, Pt; Peatmoss, Pe; Perilite, Ve; Vermiculite, Rrh; Rotted rice-hull, RPt: Russian Peatmoss) were studied. For 'Casa Blanca', plant height and length of flower stalk increased when bulbs were planted in Pt:Rrh:Ve (1:1:1, v.v$^{-1}$ ), and dried leaves of lower part plants decreased in RPt:Pe:Rrh (1:1:1, v.v$^{-1}$ ). In case of 'Marco Polo', plant height and length of lower stalk increased in Pt:Rrh (1:1, v.v$^{-1}$ ) as compared to other treatment, number of leaves and dried leaves increased when bulbs were planted in RPt:Pe:Rrh (1:1:1, v.v$^{-1}$ ) as compared to the control. Flowering of 'Casa Blanca' increased in RPt:Pe:Rrh (1:1:1, v.v$^{-1}$ ) as compared to the control and that o 'Marco Polo' increased when bulbs planted in Pt:Rrh(1:1, v.v$^{-1}$ ). Flower-bud blasting of both cultivars increased with Pt as compared. Stem firmness of 'Casa Blanca' increased in Pt:Pe:Ve (1:1:1, v.v$^{-1}$ ), and especially stem firmness of upper part plant of 'Marco Polo' increased in Pt:Rrh (1:1, v.v$^{-1}$ ) as compared to the control. Generally, stem firmness of 'Casa Blanca' was not influenced by the culture medium.

  • PDF

The Software Verification and Validation Tasks for a Safety Critical System in Nuclear Power Plants

  • Cheon Se Woo;Cha Kyung Ho;Kwon Kee Choon
    • International Journal of Safety
    • /
    • v.3 no.1
    • /
    • pp.38-46
    • /
    • 2004
  • This paper introduces the software life-cycle V&V (verification and validation) tasks for the KNICS (Korea nuclear instrumentation and control system) project. The objectives of the V&V tasks are mainly to develop a programmable logic controller (PLC) for safety critical instrumentation and control (I&C) systems, and then to apply the PLC to developing the prototype of an engineered safety features-component control system (ESF-CCS) in nuclear power plants. As preparative works for the software V&V, various kinds of software plans and V&V task procedures have been developed according to the software life-cycle management. A number of software V&V tools have been adopted or developed to efficiently support the V&V tasks. The V&V techniques employed in this work include a checklist-based review and inspection, a requirement traceability analysis, formal verification, and life-cycle based software testing.

Control Mode Switching of Induction Machine Drives between Vector Control and V/f Control in Overmodulation Range

  • Nguyen, Thanh Hai;Van, Tan Luong;Lee, Dong-Choon;Park, Joo-Hong;Hwang, Joon-Hyeon
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.846-855
    • /
    • 2011
  • This paper proposes a control mode switching scheme between vector control and constant V/f control for induction machine (IM) drives for maximum torque utilization in a higher speed region. For the constant V/f scheme, a smooth transition method from the linear range of PWM up to the six-step mode is applied, by which the machine flux and torque can be kept constant in a high-speed range. Also, a careful consideration of the initial phase angle of the voltage in the transient state of the control mode change between the vector control and V/f schemes is described. The validity of the proposed strategy is verified by the experiment result for a 3-kW induction motor drives.

A Stator Flux Oriented V/f Control of Induction Motor in Low Speed Range

  • Kim Young-Real
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.466-469
    • /
    • 2001
  • In this paper, closed loop V/f control of induction motor has been implemented by the estimated speed. Closed loop V/f control improve the performance of induction motor drive system at low speed compared to open loop V/f control. However, closed loop V/f control need speed sensor. By using the estimated speed, closed loop V/f control is possible without speed sensor. Rotor speed is calculated from the difference between synchronous frequency and slip angular frequency. 3-phase voltage reference is obtained from synchronous frequency. And the PWM technique using space vector PWM is applied in this scheme. In the space vector PWM, effective time of 3-phase voltage reference is used to simplify the calculation of effective voltage time. This scheme is simple to implement and one chip microprocessor was used in experimental system.

  • PDF

A MTPA Control Method for Sensorless V/f Operation of SPMSMs (SPMSM의 센서리스 V/f 운전 시 MTPA 제어 기법)

  • Kim, Won-Jae;Kim, Sang-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.4
    • /
    • pp.240-246
    • /
    • 2018
  • In this paper, a sensorless V/f control based on maximum torque per ampere (MTPA) operation for PMSMs is proposed. Given that the MTPA operation is not considered in the conventional sensorless V/f control, efficient PMSM drives cannot be achieved. Therefore, this paper proposes an improved technique based on the d-axis current control to enable the MTPA operation in the V/f control for PMSMs. A stabilization technique is also proposed to improve the dynamic characteristics and stability against load variation. The effectiveness of the proposed technique is verified by conducting experiments with a 250 W SPMSM for driving a blower.