• 제목/요약/키워드: Utrasonic Application

검색결과 4건 처리시간 0.018초

수소 연료 생산의 효율향상을 위한 초음파 응용에 관한 연구 - 압력센서 계기에 의한 - (A Study on the Utrasonic Application for the Efficiency Elevation of the Hydrogen Fuel Production - By the Pressure Sensor Gage -)

  • 송민근;손승우;주은선
    • 대한기계학회논문집B
    • /
    • 제27권9호
    • /
    • pp.1229-1237
    • /
    • 2003
  • The production of hydrogen fuel depends basically on the water electrolysis. The ultrasonic effects the decrease of the overpotential in a water electrolysis. A study on the overpotential which activates the hydrogen production is the core to elevate the hydrogen production efficiency on the principle. A pressure sensor system by a new idea is developed and applied. Solutions are 4 kinds of KOH concentration such as 0%, 10%, 20%, and 30%. Two frequency bands of the ultrasonic transducer are 28kHz and 2MHz. The directions of ultrasonic forcing are the vertical direction and the horizontal direction. The temperatures are two states, i.e., no constant and constant. Experiments are carried out sequentially in order in three cases of no ultrasonic forcing, ultrasonic forcing, and ultrasonic discontinution. In results, it is clarified that the ultrasonic effects the decrease of overpotential to elevate the efficiency of hydrogen production.

초음파 송수신기를 이용한 센서 네트워크 시스템 구현 (Application of sensor network by using Ultrasonic transceiver)

  • 이준규;서영석
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 춘계종합학술대회
    • /
    • pp.707-710
    • /
    • 2007
  • 본 논문에서는 초음파 트랜스듀서를 사용하여 초음파 송수신기를 제작하였으며 이를 이용한 센서 네트워크 시스템을 구현하였다. 각 센서 노드들 간의 거리에 따른 초음파 신호 감쇄를 고려하고 데이터 전송 속도에 따른 초음파 신호의 왜곡과 베이스 노드와 최종 수신노드간의 통신 프로토콜을 고려하여 설계하였다. 제작된 노드들과 초음파송수신 결합부의 크기는 각각 $50mm\times60mm$$30mm\times40mm$이며 에러율 2%의 데이터전송을 나타내었다.

  • PDF

구동회로에 따른 초음파 노즐의 분무 특성 (The Aerosol Characteristics of Utrasonic Nozzle on the Driving Circuits)

  • 이수호;민석규;윤광희;류주현;사공건
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.1005-1009
    • /
    • 2001
  • The application of the ultrasonic nozzle has been extended because it is possible atomization of liquid material. In this study, the driving characteristics of the ultrasonic nozzle on the driving circuit were investigated. And the characteristics of the ceramic oscillator were investigated for the temperature stability. The ceramic oscillator were made the Pb[(Sb$\sub$1/2/,Nb$\sub$1/2/)$\sub$0.035/-(Mn$\sub$1/3/Nb$\sub$2/3/)$\sub$0.065/- (Zr$\sub$x/Ti$\sub$l-x/)$\sub$0.9/]O$_3$with mole ratio of Zr/Ti. The ceramis oscillator were need the curie temperature of the over 300[$^{\circ}C$] for the temperature stability. When the Zr/Ti ratio was 49/51, it's curie temperature is 322[$^{\circ}C$] and the electromechanical coupling factor(k$\sub$p/) and mechanical quality factor(Q$\sub$m/) showed the values of 0.555, 1,214, respectively The resonance frequency of ceramic oscillator were from 40KHz to 45KHz. So that, the driving circuit were made a possibility that the frequency are variable. The driving current of ultrasonic nozzle showed the value of maximum 80[mA]. Also, The surface temperature of ceramic oscillator showed 80[$^{\circ}C$] at driving time 10[min]. We knew that the ultrasonic nozzle had stabile driving above 10[min.].

  • PDF

바이스펙트럼해석을 이용한 혈관의 비선형 맥동전파특성 계측에 대한 모의실험 (A Sham Experiment for the Measurement of Nonlinear Pulse Propagation Characteristics of Blood Vessel Using Bispectral Analysis)

  • 장경영;김경조
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권4호
    • /
    • pp.525-532
    • /
    • 1995
  • 이 연구는 다음 두가지 사실에 기초를 두고 있다. 첫째, 혈관의 맥동은 전통적으로 동양의 한방에서 오랫동안 인체진단을 위해 사용되어져 왔다는 것이고, 둘째는 신체조직에서 파동의 비선형전파특성이 의용진단에 유용한 정보를 준다는 것이다. 따라서, 혈관의 벽을 전파하는 맥동파의 비선형전파특성은 의용진단을 위하여 효과적으로 이용될 수 있다는 것을 예측할 수 있다. 본 논문에서는, 혈관을 따른 두 지점에서 변위파형을 초음파 도플러 신호에 대한 직교검파에 의해 구하고, 여기에 바이스펙트럼해석과 볼테라모델전개를 적용하여 두지점 사이의 비선형 전달함수를 추정하며, 이것이 의용진단에 적용가능한지 모의샘플에 대하여 고찰하는 것을 목적으로 한다.