• Title/Summary/Keyword: Utility-reduction

Search Result 196, Processing Time 0.028 seconds

Data Reduction Method in Massive Data Sets

  • Namo, Gecynth Torre;Yun, Hong-Won
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.1
    • /
    • pp.35-40
    • /
    • 2009
  • Many researchers strive to research on ways on how to improve the performance of RFID system and many papers were written to solve one of the major drawbacks of potent technology related with data management. As RFID system captures billions of data, problems arising from dirty data and large volume of data causes uproar in the RFID community those researchers are finding ways on how to address this issue. Especially, effective data management is important to manage large volume of data. Data reduction techniques in attempts to address the issues on data are also presented in this paper. This paper introduces readers to a new data reduction algorithm that might be an alternative to reduce data in RFID Systems. A process on how to extract data from the reduced database is also presented. Performance study is conducted to analyze the new data reduction algorithm. Our performance analysis shows the utility and feasibility of our categorization reduction algorithms.

Utility-Connected Solar Power Conditioner Using Edge-Resonant Soft Switching Duty Cycle Sinewave Modulated Inverter Link

  • Ogura, Koki;Chandhaket, Srawouth;Nakaoka, Mutsuo;Terai, Haruo;Sumiyoshi, Shinichiro;Kitaizumi, Takeshi;Omori, Hideki
    • Journal of Power Electronics
    • /
    • v.2 no.3
    • /
    • pp.181-188
    • /
    • 2002
  • The utility interfaced sinewave modulation Inverter for the solar photovoltaic power conditioner with a high frequency transformer is presented for residential applications. As compared with the conventional full-bridge hard switching slnewave PWM inverter with a high frequency link, the simplest single-ended edge-resonant soft switching sinewave inverter with a sinewave duty cycle pulse control scheme is implemented, resulting in size and weight reduction, low cost and high efficiency This paper presents a prototype system of the sinewave zero voltage soft switching sinewave inverter for solar power conditioner, along with its operating principle and unique features. In addition to these, this paper discusses a control implementation to deliver high quality output current. Major design of each component and the power loss analysis under actual power processing is also discussed and evaluated from an experimental point of view A newly developed utility-connected sinewave power conditioning circuit which achieves 92.5% efficiency under 4kW output is demonstrated.

Analysis of underground post-tensioned precast concrete box utility tunnel under normal fault displacement

  • Wu, Xiangguo;Nie, Chenhang;Qiu, Faqiang;Zhang, Xuesen;Hong, Li;Lee, Jong-Sub;Kang, Thomas H.K.
    • Computers and Concrete
    • /
    • v.29 no.2
    • /
    • pp.69-79
    • /
    • 2022
  • For long underground box utility tunnels, post-tensioned precast concrete is often used. Between precast tunnel segments, sealed waterproof flexible joints are often specified. Fault displacement can lead to excessive deformation of the joints, which can lead to reduction in waterproofing due to diminished contact pressure between the sealant strip and the tunnel segment. This paper authenticates utilization of a finite element model for a prefabricated tunnel fault-crossing founded on ABAQUS software. In addition, material parameter selection, contact setting and boundary condition are reviewed. Analyzed under normal fault action are: the influence of fault displacement; buried depth; soil friction coefficient, and angle of crossing at the fault plane. In addition, distribution characteristics of the utility tunnel structure for vertical and longitudinal/horizontal relative displacement at segmented interface for the top and bottom slab are analyzed. It is found that the effect of increase in fault displacement on the splice joint deformation is significant, whereas the effects of changes in burial depth, pipe-soil friction coefficient and fault-crossing angle on the overall tunnel and joint deformations were not so significant.

Spatial Decision Support System for Residential Solar Energy Adoption

  • Ahmed O. Alzahrani;Hind Bitar;Abdulrahman Alzahrani;Khalaf O. Alsalem
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.6
    • /
    • pp.49-58
    • /
    • 2023
  • Renewable energy is not a new terminology. One of the fastest growing renewable energies is solar energy. The implementation of solar energy provides several advantages including the reduction of some of the environmental risks of fossil fuel consumption. This research elaborated the importance of the adaption of solar energy by developing a spatial decision support system (SDSS), while the Residential Solar Energy Adoption (RSEA) is an instantiation artifact in the form of an SDSS. As a GIS web-based application, RSEA allows stakeholders (e.g., utility companies, policymakers, service providers homeowners, and researchers) to navigate through locations on a map interactively. The maps highlight locations with high and low solar energy adoption potential that enables decision-makers (e.g., policymakers, solar firms, utility companies, and nonprofit organizations) to make decisions. A combined qualitative and quantitative methodological approach was used to evaluate the application's usability and user experience, and results affirmed the ability of the factors of utility, usefulness, and a positive user experience of the residential solar energy adoption of spatial decision support system (RSEA-SDSS). RSEA-SDSS in improving the decision-making process for potential various stakeholders, in utility, solar installations, policy making, and non-profit renewable energy domains.

Characteristic Analysis of Wireless Channels to Construct Wireless Network Environment in Underground Utility Tunnels (지하공동구 내 무선 네트워크 환경구축을 위한 무선채널 특성 분석)

  • Byung-Jin Lee;Woo-Sug Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.3
    • /
    • pp.27-34
    • /
    • 2024
  • The direct and indirect damages caused by fires in underground utility tunnels have a great impact on society as a whole, so efforts are needed to prevent and manage them in advance. To this end, research is ongoing to prevent disasters such as fire flooding by applying digital twin technology to underground utility tunnels. A network is required to transmit the sensed signals from each sensor to the platform. In essence, it is necessary to analyze the application of wireless networks in the underground utility tunnel environments because the tunnel lacks the reception range of external wireless communication systems. Within the underground utility tunnels, electromagnetic interference caused by transmission and distribution cables, and diffuse reflection of signals from internal structures, obstacles, and metallic pipes such as water pipes can cause distortion or size reduction of wireless signals. To ensure real-time connectivity for remote surveillance and monitoring tasks through sensing, it is necessary to measure and analyze the wireless coverage in underground utility tunnels. Therefore, in order to build a wireless network environment in the underground utility tunnels. this study minimized the shaded area and measured the actual cavity environment so that there is no problem in connecting to the wireless environment inside the underground utility tunnels. We analyzed the data transmission rate, signal strength, and signal-to-noise ratio for each section of the terrain of the underground utility tunnels. The obtained results provide an appropriate wireless planning approach for installing wireless networks in underground utility tunnels.

An experimental study of electrocution-decreasing methods for Oriental Storks (Ciconia boyciana) in captivity (재도입 황새(Ciconia boyciana)의 감전사 저감을 위한 사례연구)

  • Ha, Dong-Soo;Nam, Hyung-Kyu;Yoon, Jongmin
    • Korean Journal of Ornithology
    • /
    • v.25 no.2
    • /
    • pp.112-116
    • /
    • 2018
  • Electrocution is one of the key components affecting the mortality of birds. Various electrocution-decreasing methods refer to two directions: safe perching with insulation versus perching restriction. In Yesan County, we have reintroduced 30 oriental storks (Ciconia boyciana) since 2015. Two female storks died due to electrocution while perching in a utility pole in 2016. To reduce such electrocution mortality in storks, a branch of Korea Electric Power Corporation partly installed insulators in 630 utility poles located in the major habitats of Yesan in 2016-2017. Simultaneously, we conducted an experiment to reduce the perching events using 8 captive storks and the two types of common utility poles along with/without the installation of bird-spikes and/or wires in Mar-Jun of 2017. Our results indicated the installation of additional wires alone exhibited a lack of reduction in perching, while those of bird-spikes or both significantly decreased their perching frequencies. Therefore, the present study highlights the installation of bird spikes on top of utility poles may elicit a better effect so that storks avoid perching in utility poles, presumably resulting in lowering potential electrocution in the wild.

Design of Input.Output Filter of Single Multifunctional UPS (단상 다기능 UPS 입.출력 필터 설계)

  • 김제홍
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.307-310
    • /
    • 2002
  • A design for the input filter and the output filter of a single-phase UPS system is proposed. And also, this paper describes a reduction of the DC voltage ripple of a single-phase UPS. The input power of proposed UPS fluctuates with twice frequency of the utility source, which causes DC voltage fluctuation. The reduction of the DC voltage fluctuation requires a large DC link capacitor. The proposed method uses a LC series resonant filter paralleled with a conventional smoothing capacitor. The effectiveness of the proposed method was confirmed by simulation results.

  • PDF

Development of Monitoring and Control System of Utility-Pipe Conduit (Power Tunnel) using PLC

  • Lee, Tae-Young;Park, Byung-Seok;Ju, Seong-Ho;You, Dong-Hee;Lim, Yong-Hoon;Song, Seok-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.116-119
    • /
    • 2004
  • The existing monitoring and control systems of utility-pipe conduit (power tunnel, cable tunnel etc) have established communication lines using optical fiber, leaky coaxial cable (LCX), and several kinds of control cable. Due to the properties of the used media, the cost of equipment is considerably high and the maintenance of the system is difficult. Also, the term of carrying out is long so that the extension of the system is in difficulty. Now it is desirable to adopt Power Line Communication (hereinafter, PLC) technology in the monitoring and control systems and use the existing low-voltage power-line for lamplight as communication line. This will lead the reduction of the construction cost and the easy maintenance of the system. In this paper, we research the characteristics of PLC in conduit, design and manufacture the field test system, and analyze the performance of the system by field test. Then, we introduce the reliable monitoring and control system of utility-pipe conduit using PLC.

  • PDF

Improved Operating Method of Utility Interactive PV System for Peak Power Cut Effect (첨두부하 삭감효과를 갖는 UIPV시스템의 개선된 운용방법)

  • Kim, Young-Sik;Bayasgalan, Dugarjav;Heo, Hye-Seong;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.415-422
    • /
    • 2009
  • This paper describes the UIPV(Utility Interactived Photovoltaic) system which can improve the peak-cut effect by adding energy storage device of batteries to the power converter. The proposed system has three possible operation modes depending on relative condition of PV output, which can have the power shaping function covering the peak power for 3 hours. A new power circuit and application algorithm has been applied to UIPV system which is based on working PV system during 3-hour peak time. The energy relationship by the proposed system is analyzed theoretically and experimentally. Also the proposed system is evaluated at the viewpoint of cost and total spacing, which enables the proposed UIPV system to have the reduction of the peak power demand and hence to improve.

A Study on the breakdown reduction of porcelain insulators (자기제 애자의 절연파괴 감소대책 연구)

  • Song, I.K.;Park, K.P.;Kim, Y.L.;Kim, K.W.;Kwak, H.R.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1042-1044
    • /
    • 1995
  • This paper provides the results and analyses of investigations into porcelain suspension insulators failures on the KEPCO system. The high failure rate of suspension insulators on distribution lines has been attributed to the volume expansion of the cement, the insulation puncture breakdown of the porcelain and the power arc failure. The utility must use only the good insulators and at least reduce the insulator failure rate. So, this paper recommends that the utility make test criteria(cement expansion test, steep front-of-wave flashover voltage test and power arc test. etc) on the suspension insulators.

  • PDF