• Title/Summary/Keyword: Utility Interactive Photovoltaic System

Search Result 96, Processing Time 0.019 seconds

50kw Photovoltaic Generation System of Chosun university Dormitory for Model House Power Supply (시범주택 전원용 조선대 기숙사 50kW 태양광발전시스템의 운전특성)

  • Park J. M.;Kim K. B.;Lee K. Y.;Seo J. Y.;Cho G. B.;Baek H. N.
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.62-64
    • /
    • 2002
  • This paper presents experimental operation with utility invertactive 50kW photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for dormitory. The status of photovoltaic generation system components and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for dormitory.

  • PDF

Simulation Method of Photovoltaic Generation Systems using EMTP Type Simulators (EMTP형 시뮬레이터를 이용한 태양광발전시스템 모의 방법)

  • Park Minwon;Yu In-Keun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.6
    • /
    • pp.303-308
    • /
    • 2005
  • As the cost of photovoltaic(PV) generation systems continues to decrease, utility interactive systems are becoming more economically viable. Furthermore, increases in consumer awareness correspond to a willingness to pay a premium price for clean electrical energy generated using renewable energy resources. Especially, PV generation systems, in particular, is undergoing a rapid expansion-showing an industrial growth of approximately 40$\%$ per year in the worldwide, as PV cell and systems technology improve new markets become increasingly accessible. This has resulted in an increased demand for the simulation scheme and operational technologies of utility interactive PV devices and systems. The simulation schemes that can be applied to the utility interactive PV generation systems readily and cheaply under various conditions considering the sort of solar cell, the capacity of systems and the converter system as well are strongly expected and emphasized among researchers. So far, authors have been introducing the simulation method of PV generation systems with several papers. In this paper, authors introduce the simulation way of PV generation systems using EMTP type simulators; EMTP/ATP, EMTDC/PSCAD, RTDS, with each examples. And, by connecting the voltage amplifier to the RTDS a novel simulation method which is extremely close to the real condition of PV generation system is also introduced.

A Study on the Phase Synchronization Control of the Output Voltage of the Photovoltaic Inverter (태양광 발전용 인버터 출력 전압의 위상 동기제어에 관한 연구)

  • Cheon, Hee-Young;Park, Gwi-Tae;Ahn, Ho-Gyun;Eom, Ju-Kyoung;Yoo, Ji-Yoon;Song, Jin-Su
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.367-371
    • /
    • 1990
  • The photovoltaic inverter is a system which transforms the solar energy to the electrical energy. Because the output of photovoltaic inverter depends on solar radiation, it is necessary to save generated power or to interface with utility line. This paper describes a 2KVA photovoltaic inverter utilizing IGBT, designed to have a very high efficiency in stand alone mode and to have the function synchronizing the phase between inverter and utility voltage as a fundamental study for utility interactive mode.

  • PDF

Utility Interactive Photovoltaic System for DC Reactor Reduction (직류리액터 경감을 위한 계통연계형 태양광 발전시스템)

  • Sung, Nark-Kyu;Lee, Sang-Chip;Lee, Seung-Hwan;Oh, Bong-Hwan;Lee, Hoon-Goo;Han, Kyung-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.1948-1950
    • /
    • 1997
  • In this paper, we compose of the single current source inverter for utility interactive photovoltaic system. According to insert parallel resonant circuit, the do reactor decreases the distortion of dc current and output current. Therefore, we decrease the do reactance and control modulation factor to operation at the maximum power point around of solar cell.

  • PDF

A Utility Interactive Photovoltaic Generation System using PWM Converter (PWM 컨버터를 이용한 계통연계형 태양광발전 시스템)

  • Kim, Dae-Gyun;Jeon, Kee-Young;Hahm, Nyon-Kun;Chung, Choon-Byeong;Lee, Seung-Hwan;Oh, Bong-Hwan;Lee, Hoon-Goo;Han, Kyung-Hee
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.3
    • /
    • pp.111-118
    • /
    • 2005
  • Since the residential load is an AC load and the output of solar cell is DC power, the photovoltaic system needs the DC/AC converter to utilize solar cell. In case of driving to interact with utility line, in order to operate at unity power factor, converter must provide the sinusoidal wave current and voltage with same phase of utility line. Since output of solar cell is greatly fluctuated by insolation, it is necessary that the operation of solar cell output in the range of the vicinity of maximum power point. In this paper, DC/AC converter is three phase PWM converter with smoothing reactor. And then, feed-forward control used to obtain a superior characteristic for current control and digital PLL circuit used to detect the phase of utility line.

Efficiency characteristics analysis of residential PV System (주택용 태양광발전시스템의 성능비교 분석)

  • LEE K. Y.;CHOI Y. O.;BAEK H. L.;CHO G. B.;Lee S. G.;KIM D. H.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.144-146
    • /
    • 2004
  • This paper presents experimental operation with utility invertactive 3kW photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for Demonstration experiment. The status of photovoltaic generation system comp-onents and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for demonstration experiment.

  • PDF

Analysis of Demonstration Research for Grid-connected Photovoltaics System (계통연계형 태양광발전시스템의 실증시험 분석)

  • Piao, Zheng-Guo;Kim, Seong-Kyeol;Lee, Kang-Yeon;Cho, Guem-Bae;Baek, Hyung-Lae
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.205-207
    • /
    • 2004
  • This paper presents experimental operation with utility invertactive 3kW photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for Demonstration experiment. The status of photovoltaic generation system components and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for demonstration experiment.

  • PDF

Using Demonstration PV System for Operation Efficiency Analysis (태양광발전시스템의 실증연구를 통한 운용효율 분석)

  • Park Jeong Min;Kim Seong Kyeol;Jung Byung Ho;Cho Geum-Bae;Baek Hyung Rae
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.244-246
    • /
    • 2003
  • This paper presents experimental operation with utility invertactive 3kW photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for Demonstration Complex. The status of photovoltaic generation system components and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for Demonstration Complex.

  • PDF

Demonstration analysis of residential 3kW PV System (주택보급형 3kW PV시스템 실증연구)

  • Park, J.M.;Moon, Y.A.;Kim, H.S.;Lim, B.O.;Baek, H.L.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.734-736
    • /
    • 2005
  • This paper presents experimental operation with utility invertactive 3kW photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for Demonstration experiment. The status of photovoltaic generation system comp-onents and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for demonstration experiment.

  • PDF

Rapid response control A Utility Interactive Photovoltaic Generation System (계통연계형 태양광발전 시스템의 속응성 제어)

  • Chung, Choon-Byeong;Jeon, Kee-Young;Lee, Sang-Hyun;Han, Kyung-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.279-285
    • /
    • 2007
  • Since the residential load is an AC load and the output of solar cell is a DC power, the photovoltaic system needs the DC/AC converter to utilize solar cell. In case of driving to interact with utility line, in order to operate at unity power factor, converter must provide the sinusoidal wave current and voltage with same phase of utility line. Since output of solar cell is greatly fluctuated by insolation, it is necessary that the operation of solar cell output in the range of the vicinity of maximum power point. In this paper, DC/AC converter is three phase PWM converter with smoothing reactor. And then, feedforward control used to obtain a superior characteristic for current control and digital PLL circuit used to detect the phase of utility line.

  • PDF