• Title/Summary/Keyword: Useful efficiency

Search Result 1,836, Processing Time 0.029 seconds

Experimental Study on the Effective Use of Thermally Stratified Hot Water Storage System (열성층 온수저장시스템의 효율적 이용에 관한 실험적 연구)

  • Pak, Ee-Tong
    • Solar Energy
    • /
    • v.13 no.2_3
    • /
    • pp.45-52
    • /
    • 1993
  • The benefits of thermal stratification in sensible heat storage were investigated for residential solar applications. The effect of increased thermal useful efficiency of hot water stored in an actual storage tank due to stratification has been discussed and illustrated through experimental data and computer simulation, which were taken by changing dynamic and geometric parameters. When the flow rate was 8 liter/min and ${\Delta}T=40^{\circ}C$ was $40^{\circ}C$, the useful efficiency(${\eta}_u$) was about 90% in case of using a distributor, but not using a distributor the useful efficiency(${\eta}_u$) was about 82%. So these kinds of distributor would be recommendable for a hot water storage system and residential solar energy application to increase useful efficiency(${\eta}_u$). In the case of the uniform circular distributor, when the flow rate was 8 liter/min partial mixing was decreased and a stable stratification was obtained. Furthermore, if the distrbutor was manufactured so that the flow is to be the same from all perforations in order to enhance stratification, it might be predicted that further stable stratification and higher useful efficiency(${\eta}_u$) are obtainable.

  • PDF

Analysis on the Energy Performance of Solar Water Heating System according to the Configuration of Flat Plate Collectors (태양열급탕시스템의 집열기 배열에 따른 에너지성능 분석 및 평가)

  • Ko, Myeong-Jin;Lim, Bo-Min;Kim, Yong-Shik
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.4
    • /
    • pp.49-56
    • /
    • 2016
  • The objective of this work is to analyze the variation in energy performance for each flat plate collector connected in series. In this study, it was assumed that solar water heating system with annual solar fraction of 60% was installed in an office building in Seoul, South Korea. The transient energy performance corresponding to four cases, which are selected using different solar radiation and outdoor air temperature, is studied by analyzing the variation in outlet temperature, solar useful heat gain, and thermal efficiency of each collector. It is observed that the useful heat gain and the collector efficiency decrease continuously, and outlet temperature increases when increasing the number of collector connected in series. The long-term performance is assessed by evaluating the thermal efficiency of each collector for two solar radiation conditions ranging from 780 to $820W/m^2$ and from 380 to $420W/m^2$. It is found that the differences between the intercept and slope of the efficiency curves for first and eighth collectors are 3.68% and 6.74% for solar radiation of $800{\pm}20W/m^2$ and 8.57% and 12.90% for solar radiation of $400{\pm}20W/m^2$, respectively. In addition, it is interesting to note that annual useful heat gain and collector efficiency are reduced with similar rate of about 6.13% when increasing the collector area by connecting the collectors in series.

An Experimental and Numerical Study on Thermal Performance of a Regenerator System with Ceramic Honeycomb

  • Ryou, Hong-Sun;Noh, Dong-Soon;Hong, Sung-Kook;Lee, Seong-Hyuk
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.357-365
    • /
    • 2001
  • The aim of this paper is to perform the experiment and the numerical simulation for investigating the heat transfer in a regenerator system with ceramic honeycomb and to suggest a useful correlation for optimization of the regenerator system. For achieving this, the effects of some parameters were investigated, e. g., switching time, cell size and length of honeycomb on the mean temperature efficiency. The measured temperatures by R-type thermocouples were compared with the predictions by means of the commercial package, STAR-CD. A useful correlation for thermal efficiency was newly proposed as a function of the normalized switching time, defined in terms of switching time, cell size and length of honeycomb. The results showed that the thermal efficiency is above 90% and the normalized heat exchange rate is higher than 80% when the normalized switching time is less than 1000.

  • PDF

Modeling Analysis for Thermal Performance of Solar Flat Plate Collector System Through a Year (평판형 태양열 집열기의 연중 열적 성능의 모델링 해석)

  • Kim, Gew Deok;Park, Bae Duck;Kim, Kyoung Hoon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.5
    • /
    • pp.541-549
    • /
    • 2014
  • The monthly-average meteorological data, in particular, the monthly average daily terrestrial horizontal insolation are required for designing solar thermal energy systems. In this paper, the dynamic thermal performance of a flat plate solar collector system is numerically investigated through a year from the monthly average insolation data in Seoul. For a specified data set of solar collector system, the dynamic behaviors of total solar radiation on the tilted collector surfaces, heat loss from the collector system, useful energy and collector efficiency are analyzed from January to December by a mathematical simulation model. In addition, the monthly average daily total solar radiation, useful energy, and daily collector efficiencies through a year are estimated. The simulated results show that the average total radiation is highest in March and the useful energy is highest in October, while the total radiation and the collector efficiency are lowest in July.

Efficiency Benchmarking of Hospitals Using DEA (DEA를 이용한 의료기관의 효율성 벤치마킹)

  • Seo, Su-Kyong;Kwon, Soon-Man
    • Korea Journal of Hospital Management
    • /
    • v.5 no.1
    • /
    • pp.84-104
    • /
    • 2000
  • This paper analyzes the technical efficiency of thirty two hospitals in Korea using DEA(Data Envelopment Analysis). DEA provides an efficiency measure for each hospital compared to the most efficient one. The amount and sources of inefficiency that are identified by the DEA are useful for benchmarking to improve efficiency. The results from multiple regression analysis and Wilcoxon Rank Sum test show that bed turnover, hospital size, and average length of stay are related to hospital efficiency.

  • PDF

A Study on a Simple Efficiency Estimation of Small DC Motor (소형 직류모터의 간략한 효율예측에 관한 연구)

  • Won, Sung Hong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.3
    • /
    • pp.143-148
    • /
    • 2014
  • This paper proposes a novel efficiency measurement method without dynamometer. In case of small motor, the measurement of efficiency is not easy because the percentage of mechanical loss is comparably huge and the mechanical loss is not easy to be measured. In this paper, the authors proposes a method which can measure the efficiency with two test motors. This method can be useful to engineers who study small electrical motors.

Dust accumulation effect on solar thermal energy systems performance

  • Alsaad, Mohammad A.
    • Advances in Energy Research
    • /
    • v.3 no.3
    • /
    • pp.157-165
    • /
    • 2015
  • This research investigates the effect of natural dust accumulation on the glass cover of solar thermal energy conversion systems. Four similar, locally manufactured, flat plate solar collectors are used. All collectors are South oriented with tilt angle of $40^{\circ}$. The glass cover of one collector is kept clean of dust during the experimental period while the second collector is cleaned at the beginning of each month. The third collector is cleaned every two months while the fourth collector is kept un-cleaned throughout the experimental period of four months. The calculated parameters are the solar heat gain rates and the corresponding values of the thermal efficiency. The result of the present work indicates that the percentage of fractional reduction of the useful heat gain rate due to dust accumulation during a period of one and two months is 11.4% and 17.0%, respectively. The percentage decrease of thermal efficiency during the same duration periods is 4.0% and 6.1%, respectively. The percentage of fractional reduction of the useful heat gain rate due to dust accumulation during a period of three and four months is 27.8% and 31.9%, respectively. The percentage decrease of monthly thermal efficiency during the same duration period is 10.2% and 11.3%, respectively.

The Moderating Effect of Operations Efficiency on the Links between Environmental Performance and Financial Performance: The UK Evidence

  • Ramanathan, Ramakrishnan;Akanni, Adewole Oluwatomi
    • Asian Journal of Innovation and Policy
    • /
    • v.4 no.1
    • /
    • pp.76-102
    • /
    • 2015
  • Drawing upon the resource-based-view of a firm, we investigate the moderating role of operations efficiency on the link between environmental and financial performance. Extant literature has highlighted that operations efficiency is closely associated with the environmental/financial performance of firms, but no empirical study has investigated how operations efficiency affects the link between environmental and financial performance. We argue that operations efficiency could act as a moderator of this relationship. To test the hypothesized relationships, we have used available secondary quantitative UK data, namely data on the environmental/financial performance of Britain's most admired companies. By employing moderated regression analysis, we have found strong evidence for the moderating impact of operations efficiency. Our results are useful to managers in that they show that improvements in operations efficiency in a company can also help improve environmental/financial performance and vice versa.

A Study on the Optimum Design of Intake System for 4 Cylinder Diesel Engines (4실린더 디젤기관 흡기계의 최적설계에 관한 연구)

  • 조규철;강인철;남정길;최재성
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.5
    • /
    • pp.104-113
    • /
    • 1997
  • In this paper, the effects of intake manifold systems on volumetric efficiency were investigated in the 4-cylinder 4-stroke cycle diesel engines. The effects of intake manifold system were analyzed on resonant speed and on volumetric efficiency. Resonant speed was calculated by acoustic theory and volumetric efficiency by the method of characteristics. The calculation results agreed well with rest results. It was assured that between the resonant speed and the volumetric efficiency there exists good correlation in multi-cylinder engines. As the results, the prediction of resonant speed was useful to design the optimum intake system. It was assured that the intake manifold systems for BOX-type and RAM-type have different characteristics on the trend of volumetric efficiency. Also a procedure to design the desirable intake manifold system was proposed.

  • PDF

A prediction of the scavenging efficiency and the performance of a two-stoke SI engine with the different exhaust systems (배기관 형상에 따른 2행정기관의 소기효율 및 성능 예측)

  • Chung, J.E.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.2
    • /
    • pp.130-135
    • /
    • 1995
  • In this paper, the numerical simulation of the method of characteristics for a two-stroke SI engine was carried out, and the scavenging efficiency and the performance of single engine with two types of exhaust system, that is, a pipe exhaust system and a tuned exhaust system, were predicted and compared. The conculusions are obtained as follows. (1) The method of characteristics of hometropic flow considering the friction and the variation of area is useful to predict the scavenging efficiency and the performance of the two-stroke engine. (2) The shape of exhaust system effects directly on the scavenging and the trapping efficiency. (3) A tuned exhaust system consisted of the diffuser and the convergent nozzle makes the plugging pulse and therefore enhances the scavenging and the trapping efficiency. (4) It may be possible to design the optimum exhaust system by using the plugging pulse.

  • PDF