• 제목/요약/키워드: Used Insulation Oil

검색결과 95건 처리시간 0.024초

가스분석을 이용한 전력용 변압기 이상진단 연구 (A Study of the Preventive Diagnostic Algorithm of Gas Analysis in Oil for Power Transformer)

  • 최인혁;권동진;정길조;유연표;선종호;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1676-1678
    • /
    • 2001
  • In general, power demand is on an increasing trend as industries have made rapid strides. Power transformer is the most important equipment in substation for this reason. Transformer trobles go with blackout, expensive repair costs and huge economic losses. Therefore it is important to find the quick detection of incipient fault for the least losses. There have been gas, partial discharge, temperature, OLTC, fan and pump diagnosis for preventive techniques by present. Specially gas analysis has been adapted for a long time and proved as confident method. In this paper, we analysed the fault causes of used power transformer. The insulation faults was occupied 40% of inquired 152 faults from 1991 to 2000. This study presents the developed algorithm and expert system for finding abnormal status within transformer. We used the Element Expert tool developed Neuron DATA Inc.

  • PDF

코어공명을 이용한 허니콤패널의 흡음율 개선에 관한 연구 (A study on the improvement of sound absorption coefficient of an honeycomb panel by the core resonance)

  • 유영훈
    • 동력기계공학회지
    • /
    • 제12권4호
    • /
    • pp.46-51
    • /
    • 2008
  • Honeycomb panel has a constructive advantage because it is constructed with a honeycomb core, so it has relatively higher strength ratio to weight. Therefore honeycomb panel has been used as the light weight panels in the high-speed railway technology and high-speed ship like as cruise yachts. Also it has been used in the aircraft and aerospace industry as a structural panel because light weight structure is indispensible in that field of industry. Recently, the honeycomb panel is embossed in the viewpoints of high oil prices as the lightweight panel of the transport machine, however the sound insulation capacity of the honeycomb panel is poorer than those of uniform and another sandwich panels. In this paper a method to improving the sound absorption coefficient of a honeycomb panel Is studied by using the Helmholtz resonator. The sound absorption coefficients for some kinds of honeycomb cores are demonstrated by the normal incident absorption coefficient method.

  • PDF

자동차의 블랙박스 와이어링 화재 위험성에 관한 연구 (A Study on the Fire Risk of Black Box Wiring in Motor Vehicle)

  • 강신동;김주희;최준표;김재호
    • 한국안전학회지
    • /
    • 제32권6호
    • /
    • pp.22-28
    • /
    • 2017
  • According to the National Fire Data System (NFDS), more than 5,000 vehicle fires have occurred every year for the last 10 years. Vehicle fires are primarily caused by mechanical (breaking system and engine), electrical (wiring and battery), and chemical (oil and fuel gas leakage) problems. The electrical factor has increased with the installation of driver convenience equipment. For example, today, the black box is widely used to provide video data recording of motor vehicle accidents. The black box consists of a front camera, rear camera, and wires. The black box wires are directly connected to the junction box or fuse box from the start battery that operates to provide normal on power supplying for engine stop. It is extremely dangerous when the wires short circuit due to insulation aging, mechanical and electrical stress, etc. In this study, the black box wiring fire risk have been analyzed and investigated when the steady state and abnormal operations, and under the following conditions: wiring arrangements with a high temperature condition, insulation aging, poor contact, and short circuits. The results showed that black box wiring short circuits had a higher fire risk than the other fire hazard elements. To prevent fire hazards caused by black box wiring, the black boxes must be installed by qualified service personnel. Do not modify the wiring, remove the fuse and secure the wiring using cable ties or insulation tape.

변압기용 ONAF 방식 방열기의 팬 배치에 따른 냉각특성 연구 (Numerical Study of the Effect of Fan Arrangement on the Cooling Performance of the ONAF Type Radiator for Power Transformer)

  • 김국겸;서용권;강상모
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.449-455
    • /
    • 2015
  • 전력용 변압기 용량의 증대와 고효율화에 따른 권선의 단위체적당 열발생량의 증가 및 이에 따른 절연성능의 저하는 전력용 변압기의 수명과 신뢰성에 큰 영향을 준다. 이러한 문제점은 방열기의 냉각성능을 증가시킴으로써 해결이 가능하다. 본 연구는 ONAF(Oil Natural Air Forced) 형식의 변압기의 방열기에 대해 공기의 강제대류를 일으키는 팬의 위치에 따른 냉각성능 평가를 통하여 냉각효과가 가장 큰 팬의 위치를 찾기 위한 것이다. 해석에는 유동해석 상용소프트웨어를 사용하였으며, 해석시간의 단축을 위하여 오일의 냉각유로를 단순화시켰고 팬의 지름을 일정하게 두고 팬의 위치를 다양하게 변화시켜가며 해석을 실행하였다. 해석 결과 팬의 수직적인 위치 변화는 냉각성능에 크게 영향을 주지 않았으나 팬이 변압기의 전방영역에 위치할 경우 후방영역의 배치보다 온도강하가 큰 것을 확인할 수 있었다.

셀룰로오스 절연지의 열화온도에 따른 절연특성 및 통계처리에 의한 상관관계 규명 (Estimating for Properties of Insulating Degradation for Cellulose paper with Aging Temperature and Correlation by Statistical Treatment)

  • 김재훈;김대식;한상옥
    • 전기학회논문지
    • /
    • 제59권5호
    • /
    • pp.912-917
    • /
    • 2010
  • It was known that oil-filled transformer's life depended on insulating paper which was applied to transformers for insulating of transformer. Therefore when paper was aged, its electrical, mechanical and chemical characteristics were changed. Especially if operating temperature was high, paper was quickly damaged. As cellulose paper which was mainly used for solid insulation of transformers was degraded, the cellulose polymer chains broke down into shorter lengths and gases such as CO, $CO_2$, $CH_4$, $C_2H_4$ and so on were produced from paper. Also by-product known as furan compounds were producted from paper and it were dissolved within insulating oil. In this paper accelerating aging cell was aged during 60 hours at 100, 150, 180 and $200^{\circ}C$, respectively, so evaluating the chemical characteristics of cellulose paper by thermal. An it were performed analysis such as tensile strength(TS), dissolved gas analysis(DGA) and high performance liquid chromatography(HPLC). Also for analyzing of correlation between insulating degradation characteristics, it was performed linear regression method as statistical treatment.

가교폴리에틸렌 계면에서의 트리성장 분석 (An Analysis of Tree Growth in the XLPE Interface)

  • 김철운;박현빈;김태성;이준웅
    • 한국전기전자재료학회논문지
    • /
    • 제11권2호
    • /
    • pp.90-94
    • /
    • 1998
  • This study aims at analyzing to treeing in the solid-solid interface which is insulation type of cable junction parts, the proceeding of tree-growth and electrical breakdown were research in the study. Interface was made artificially to detect how it influenced the insulating ability of the whole system, the specimen were XLPE generally used in cable. The interface conditions were divided into two parts. First condition being the one focused on the surface of interface, it was treated with sand paper (#80, #600, #1200). For the second condition, the pressure of interface was varied as the value of 1, 5, 10 [$kg/cm^2$]. Using above conditions, treeing and breakdown properties on tree-growth were respectively compared in details. As a result, breakdown time was shorter for the full range of supplied voltage in the case of interface existed in the joint than non-existed interface. In the case of existed interface, the interface which had high-interface pressure and painted with silicon insulating oil was the best in the aspect of breakdown characteristics.

  • PDF

송전용 OF 케이블의 절연특성 분석방법에 대한 고찰 (The Investigation of Analytical Techniques for Insulation Characteristics of Oil-Filled Transmission Cables)

  • 김종은;서광석;김정태;이전선;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1608-1610
    • /
    • 1999
  • To find effective diagnostic method for Transmission OF cables, various characterizations were carried such as DGA (dissolved gas analysis), water contents, total acidity and AC breakdown voltage. It was found that the result was varied by sampling and container. The results from those characterization method showed the present condition and history very well and could be used to estimate the degree of degradation of cables.

  • PDF

$SF_6$가스절연 변압기 ($SF_6$ Gas Insulated Transformer)

  • 조광제;홍기돈;하영식;조규복;노철웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.304-309
    • /
    • 1991
  • We introduce the trend, of several countries, to the gas insulated transformer recently coming into the spot light by the advantages of less weight, GIS-lization, low noise level and easiness to decrease environmental pollutions, and the insulating gases. the cooling media and the insulating materials used for transformer. Hereinafter, additively the design of proto type $SF_6$ gas insulated transformer (insulation, cooling), which was developed by us(HICO) from 1987. 2 through 1990. 3, the manufacturing processes(leak protection, pressure, drying of main body), the accessories, the protective system, the cooling system, the method and the results of test and the evaluation of economics compared with conventional oil-filled transformer are represented.

  • PDF

O.F. Cable에 연결된 154kV GIS의 뇌보호 (Lightning protection in an 154kV GIS connected by oil-filled cables)

  • 정태호
    • 전기의세계
    • /
    • 제29권5호
    • /
    • pp.315-320
    • /
    • 1980
  • It has been appeared and widely used today SF6 Gas Insulated Substation(Hereafter called GIS) for the power supply to the densely populated area due to the superior insulation withstand ability of SF6 Gas. And to maximize the compact effect of this substation, it is normal practice to connect underground cables. If it is possible to elieminate the redundant lightning arresters using the physical characterestics of travelling waves in underground cables, economical advantages can be obtained together with easy maintenances. It is presented in this paper the possiblity of eliminating the transformer protection lightning arresters under some conditions for the 154kV GIS's (BIL:750kV) which Korea Electric Co. plans to construct using the general purpose digital computer program.

  • PDF

The Fault Diagnosis of a Transformer Using Neural Network and Transfer Function

  • Park, Byung-Koo;Kim, Jong-Wook;Kim, Sang-Woo;Park, Poo-Gyeon;Park, Tae-Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.127.2-127
    • /
    • 2001
  • A transformer is one of the most important elements in the power network. Transformer faults could cause costly repairs and be dangerous to personnel. To avoid this, its reliable operation has great significance and, therefore, the diagnosis system of the transformer is necessitated. The dissolved gas-in-oil analysis (DGA) is the worldwide popular method of detecting faults such as a hot spot or partial discharges inside the transformer. DGA, however, is not a reliable technique to identify aging phenomena and mechanical faults including insulation failure, inter-turn short, etc. To overcome the drawbacks of DGA, the transfer function method is used to identify effectively these kinds of the mechanical faults. The transformer has a unique transfer function independent of the shape of the input waveform, which can be evaluated through sweep test. This transfer function changes by winding ...

  • PDF