• Title/Summary/Keyword: Usability Evaluation

Search Result 905, Processing Time 0.038 seconds

A Study to Improve the Trustworthiness of Data Repositories by Obtaining CoreTrustSeal Certification (CoreTrustSeal 인증 획득을 통한 데이터 리포지토리의 신뢰성 향상을 위한 연구)

  • Hea Lim Rhee;Jung-Ho Um;Youngho Shin;Hyung-jun Yim;Na-eun Han
    • Journal of the Korean Society for information Management
    • /
    • v.41 no.2
    • /
    • pp.245-268
    • /
    • 2024
  • As the recognition of data's value increases, the role of data repositories in managing, preserving, and utilizing data is becoming increasingly important. This study investigates ways to enhance the trustworthiness of data repositories through obtaining CoreTrustSeal (CTS) certification. Trust in data repositories is critical not only for data protection but also for building and maintaining trust between the repository and stakeholders, which in turn affects researchers' decisions on depositing and utilizing data. The study examines the CoreTrustSeal, an international certification for trustworthy data repositories, analyzing its impact on the trustworthiness and efficiency of repositories. Using the example of DataON, Korea's first CTS-certified repository operated by the Korea Institute of Science and Technology Information (KISTI), the study compares and analyzes four repositories that have obtained CTS certification. These include DataON, the Physical Oceanography Distributed Active Archive Center (PO.DAAC) from NASA, Yareta from the University of Geneva, and the DARIAH-DE repository from Germany. The research assesses how these repositories meet the mandatory requirements set by CTS and proposes strategies for improving the trustworthiness of data repositories. Key findings indicate that obtaining CTS certification involves rigorous evaluation of organizational infrastructure, digital object management, and technological aspects. The study highlights the importance of transparent data processes, robust data quality assurance, enhanced accessibility and usability, sustainability, security measures, and compliance with legal and ethical standards. By implementing these strategies, data repositories can enhance their reliability and efficiency, ultimately promoting wider data sharing and utilization in the scientific community.

Quality Characteristics of Syrup made with Saccharified Barley Liquid (보리당화액을 첨가한 시럽의 제조와 품질특성)

  • Kim, Ji-Hyun;Cho, Eun-Ju
    • Culinary science and hospitality research
    • /
    • v.21 no.6
    • /
    • pp.242-254
    • /
    • 2015
  • Barley is a main food source, along with rice, in our dietary life that is easy to buy and process. It is required to develop a beverage base and barley syrup for desserts in order to raise utilization of barley beyond its present use in Sikhye (sweet fermented rice drink) and Jocheong (grain syrup) production. In pursuit of the goal to increase the usability of barley as an ingredient of processed food, this study examined the optimal preparation conditions of barley mash for barley syrup. In addition, the study prepared a barley syrup using saccharified barley liquid, analyzed quality characteristics, and conducted a sensory evaluation. Saccharified barley liquid(barley mash) was prepared with ratios of adding malt of unhulled barley germinated as 0 g(CON), 10 g(BM10), 20 g(BM20), and 30 g(BM30). The results of measuring pH under the varied conditions of saccharification temperatures from $50^{\circ}C$, $60^{\circ}C$, and $70^{\circ}C$, as well as time from 1 to 8 hours, treveal that the optimum condition for malt saccharification is $60^{\circ}C$ for 5 hours. By adding oligosaccharides and lemon juice to the saccharified barley liquid at the different ratios of added malt, this study measured quality characteristics(color value, viscosity, pH, sweetness) of barley syrup warmed up for 1 hour. As the result of measuring color in the barley syrup prepared by saccharified barley liquid, higher levels of added malt saw L-value decreased while a-value and b-value both increased. BMs30 showed the highest viscosity of $1,202.67{\pm}3.06$. As for pH, BMs30 was the highest at pH $3.57{\pm}0.02$. The result of the sensory evaluation of barley syrup showed the superior sensory characteristics of BMs20 in terms of color, flavor, sweetness, viscosity and overall quality.

The Comparative Analysis Study and Usability Assessment of Fat Suppressed 3D T2* weighted Technique and Fat Suppressed 3D SPGR Technique when Examining MRI for Knee Joint Cartilage Assesment (슬관절 연골 평가를 위한 자기공명영상 검사 시 지방 신호 억제 3D T2* Weighted 기법과 지방 신호 억제 3D SPGR 기법의 비교 및 유용성 평가)

  • Kang, Sung-Jin
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.6
    • /
    • pp.219-225
    • /
    • 2016
  • In this study, for assessment of degenerative knee joint cartilage disease we acquired images by fat suppressed 3D spoiled gradient recalled (SPGR) and fat suppressed 3D $T2^*$ weighted imaging techniques. To do a quantitative evaluation, the knee joint cartilage was divided into medial femoral cartilage (MFC), medial tibial cartilage (MTC), lateral femoral cartilage (LFC), lateral femoral cartilage (LFC) and patella cartilage (Pat) to measure their respective signal intensity values, signal-to-noise ratio, and contrast-to-noise ratio. As for the measured values, statistical significance between two techniques was verified by using Mann-Whitney U-Test. To do a qualitative evaluation, two radiologists have examined images by techniques after which image artifact, cartilage surface, tissue contrast, and depiction of lesion distinguishing were evaluated based on 4-point scaling (1: bad, 2: appropriate, 3: good, 4: excellent), and based on the result, statistical significance was verified by using Kappa-value Test. 3.0T MR system and HD T/R 8ch knee array coil were used to acquire images. As a result of a quantitative analysis, based on SNR values measured by using two imaging techniques, MFC, LFC, LTC, and Pat showed statistical significance (p < 0.05), but MTC did not (p > 0.05). As a result of verifying statistical significance for measured CNR value, MFC, LFC, and Pat showed statistical significance (p < 0.05), while MTC and LTC did not show statistical significance (p > 0.05). As a result of a qualitative analysis, by comparing mean values for evaluated image items, 3D $T2^*$ weighted Image has indicated a slightly higher value. As for conformance verification between the two observers by using Kappa-value test, all evaluated items have indicated statistically significant results (p < 0.05). 3D $T2^*$ weighted technique holds a clinical value equal to or superior to 3D SPGR technique with respect to evaluating images, such as distinguishing knee joint cartilages, comparing nearby tissues contrast, and distinguishing lesions.

An Assessment on the Urban Riverfront in Shincheon, Daegu - Focused on a Universal Design Concept - (대구광역시 신천의 친수공간 평가 연구 - 유니버설디자인 개념을 중심으로 -)

  • Choi, Dong-Sik;Moon, Ji-Won;Kim, Shang-Hee
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.2
    • /
    • pp.1-14
    • /
    • 2012
  • The purpose of this study is to derive a desirable riverfront construction plan to me for the activities of citizens through the evaluation and analysis of the urban riverfront space from the perspective of universal design. Therefore, previous studies were examined in order to induce evaluation tools that bhve been grafted from the universal design concept; in addition, a field survey was conducted in Shincheon, Daegu, which was selected as the study target, in order to induce problems and improvement directions from the perspective of universal design. The major results can be summarized as follows. (1) In the 'fairness' aspect, all the items such as installation of integrated functional signage, showing pictures, symbols, foreign language signs, and restroom entrances signage were determined to be 'All Unsuitable' for all sections; and therefore, it is necessary to improve the fairness of usage for everybody. (2) In the 'Functionality(Usability)' aspect, all items such as installation of bicycle paths beside access roads, installation of integrated functional signs, and night light signs were determined to be 'All Unsuitable' for all sections; therefore, it is necessary to improve the functionalities of these facilities. (3) In the 'Convenience' aspect, all items such as the installation of bicycle parking areas, continuous rest facilities, and back and ann support(handles) at resting facilities were determined to be 'All Unsuitable' for many sections; therefore, it is necessary to improve these facilities for the convenience of usage. (4) In the 'Information(Recognizability)' aspect, all items such as showing pictures, symbols, foreign languages and installation of night light signs, and restroom entrances signage were determined to be 'All Unsuitable' for all sections; therefore, it is necessary to improve the recognizability to minimize misunderstandings and confusion. (5) In the 'Safety' aspect, all items such as the installation of safe pedestrian paths in parking areas, using anti-slip and shock absorption materials on restroom floors, and the continuous installation of pedestrian paths that are separate from bicycle paths were determined to be 'All Unsuitable' for all sections; therefore, it is necessary to improve the safety to prevent accidents. (6) In the 'Amenity' aspect, access roads, parking areas, hygiene facilities, convenience facilities, and waterside facilities for many sections were determined to be 'All Unsuitable'; therefore, it is necessary to conduct more concentrated hygiene management. (7) In the 'Accessibility(Mobility)' aspect, all items such as the installation of safe pedestrian paths in parking areas, and continuous pedestrian paths that are separate from bicycle paths were determined to be 'All Unsuitable' for all sections; therefore, it is necessary to improve the accessibility to provide safety and convenience. (8) In the 'Durability' aspect, access roads, parking areas, rest facilities, convenience facilities, fitness facilities, and waterside facilities were determined to be 'All Unsuitable' for many sections, therefore, it is necessary to improve sunken or damaged areas by inspecting facilities by section.

Evaluation of the usefulness of the method according to changes in patient breathing during chest 4D CT imaging (흉부 4D CT에서 호흡 변화에 대한 일시 중지 및 재개 방법의 유용성 평가)

  • Heo, Sol;Shin, Chung Hun;Jeong, Hyun Sook;Yoo, Soon Mi;Kim, Jeong Mi;Yun, In Ha;Hong, Seung Mo;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.47-54
    • /
    • 2021
  • Purpose : In order to evaluate the usefulness of clinical application of the Pause & Resume methods by comparing and analyzing the data stability and dose reduction effect when repeat scan assuming irregular breathing and using the Pause & Resume method during chest 4D CT using QuasarTM Phantom. Materials and Methods : Using the QuasarTM Phantom, set the breathing rate per minute to 15 BPM and 7.5 BPM, and set the S15 point as an irregular breathing section, and then placed OSLD to this point and use the Pause & Resume method to measure the dose of S15. CTDIvol, DLP, and ALARA-CT were used for comparative analysis of radiation dose between Pause & Resume method and Repeat-scan. In order to evaluate the stability and usability of the data applying the Pause & Resume method, the captured images were sorted by Advanced Workstation Volume Share7 and then sent to EclipseTM, the diameter and volume were analyzed by forming a contour on the iron ball in the QuasarTM Phantom Results : When using Pause & Resume, the dose of OSLD measurement increased by 1.97 times in the section of S15. As a result of image evaluation, the average value of all volumes measured with and without the Pause & Resume method at 15 BPM and 7.5 BPM was 15.2 cm3±0.5%.Allthemeasuredvaluesfor the radius of iron ball were 3.1 cm regardless of whether Pause & Resume method was used or not. In the case of using Pause & Resume, 33% decreased from the lowest DLP value and 38% decreased from the highest DLP value of repeat scan, and the effective dose also decreased 32.1% from the minimum value and 37.6% from the maximum value. Conclusion: Irradiation dose was increased by Pause & Resume method because of the repeat scan on the S15 site where assuming irregular breathing occurred, However Pause & Resume method led to a significant reduction in dose on overall scan range. It also proved the usefulness of clinical application of the Pause & Resume method as a result of similar diameters and volumes of iron ball measurement.

Evaluation of Usability Both Oblique Verification for Inserted Fiducial Marker of Prostate Cancer Patients (Fiducial Marker가 삽입된 전립선암 환자를 대상으로 한 양사방향 촬영의 유용성 평가)

  • Kim, Koon Joo;Lee, Jung Jin;Kim, Sung Gi;Lim, Hyun Sil;Kim, Wan Sun;Kang, Su Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The way check the movement of the fiducial marker insertion in the treatment of patients with prostate cancer. However the existing methods of fiducial marker verification process difficult to identify the specific location of the marker behind the femur and pelvic bone. So to study the evaluation of maker match with using kilo voltage (KV) X-ray by On-board imager to both oblique verification method. Materials and Methods: Five patients were selected for rectal ballooning and inserted fiducial marker. Compare the position of the fiducial marker of reference plan 2D/2D Anterior/Posterior verification method and 2D/2D both oblique verification method. So to measurement the shift score of X, Y, Z (axis) and measure exposure dose given to patients and compare matching time. Results: 2 dimensional OBI KV X-ray imaging using two-dimensional matching image are orthogonal, so locating fiducial marker matching clear and useful DRR (digital reconstruction radiography) OBI souce angle ($45^{\circ}/315^{\circ}$) matching most useful. 2D/2D both oblique verification method was able to see clearly marker behind the pelvic bone. Also matching time can be reduced accordingly. According to the method of each matching results for each patient in each treatment fraction, X, Y, and Z axis the Mean $value{\pm}SD$ (standard deviation) is X axis (AP/LAT: $0.4{\pm}1.67$, OBLIQUE: $0.4{\pm}1.82$) mm, Y axis (AP/LAT: $0.7{\pm}1.73$, OBLIQUE: $0.2{\pm}1.77$) mm, Z axis (AP/LAT: $0.8{\pm}1.94$, OBLIQUE:$1.5{\pm}2.8$) mm. In addition, the KV X-ray source dose radiation exposure given to the patient taking average when AP/LAT matching is (0.1/2.1) cGY, when $315^{\circ}/45^{\circ}$ matching is (0.27/0.26) cGY. Conclusion: In conclusion for inserted fiducial marker of prostate cancer patients 2D/2D both oblique matching method is more accurate verification than 2D/2D AP/LAT matching method. Also the matching time less than the 2D/2D AP/LAT matching method. Taken as the amount of radiation exposure to patients less than was possible. Suggest would improve the treatment quality of care patients more useful to establish a protocol such as case.

  • PDF

Evaluation of usability of the shielding effect for thyroid shield for peripheral dose during whole brain radiation therapy (전뇌 방사선 치료 시 갑상선 차폐체의 주변선량 차폐효과에 대한 유용성 평가)

  • Yang, Myung Sic;Cha, Seok Yong;Park, Ju Kyeong;Lee, Seung Hun;Kim, Yang Su;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.265-272
    • /
    • 2014
  • Purpose : To reduce the radiation dose to the thyroid that is affected to scattered radiation, the shield was used. And we evaluated the shielding effect for the thyroid during whole brain radiation therapy. Materials and Methods : To measure the dose of the thyroid, 300cGy were delivered to the phantom using a linear accelerator(Clinac iX VARIAN, USA.)in the way of the 6MV X-ray in bilateral. To measure the entrance surface dose of the thyroid, five glass dosimeters were placed in the 10th slice's surface of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. In the same location, to measure the depth dose of the thyroid, five glass dosimeters were placed in the 10th slice by 2.5 cm depth of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. Results : Entrance surface dose of the thyroid were respectively 44.89 mGy at the unshield, 36.03 mGy at the bismuth shield, 31.03 mGy at the 0.5 mmPb shield and 23.21 mGy at a self-made 1.0 mmPb shield. In addition, the depth dose of the thyroid were respectively 36.10 mGy at the unshield, 34.52 mGy at the bismuth shield, 32.28 mGy at the 0.5 mmPb shield and 25.50 mGy at a self-made 1.0 mmPb shield. Conclusion : The thyroid was affected by the secondary scattering dose and leakage dose outside of the radiation field during whole brain radiation therapy. When using a shield in the thyroid, the depth dose of thyroid showed 11~30% reduction effect and the surface dose of thyroid showed 20~48% reduction effect. Therefore, by using the thyroid shield, it is considered to effectively protect the thyroid and can perform the treatment.

Heart Rate Variability and Parenting Stress Index in Children with Attention-Deficit/Hyperactivity Disorder (주의력결핍 과잉행동장애 아동에서의 심박 변이도와 양육 스트레스)

  • Kim, Soo-Young;Lee, Moon-Soo;Yang, Jae-Won;Jung, In-Kwa
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.19 no.2
    • /
    • pp.74-82
    • /
    • 2011
  • Objective:The aim of this study was to evaluate the relationship between sustained attention deficits in Attention-Deficit/Hyperactivity Disorder(ADHD) children and short-term Heart Rate Variability(HRV) parameters. In addition, we evaluate the relationship between The ADHD rating scale(ARS), the computerized ADHD diagnostic system(ADS) and Parenting stress index- short form(PSI-SF). Methods:This study was performed in the department of children and Adolescent psychiatry, Korea university Guro hospital from august 2008 to January 2009. We evaluated HRV parameters by short-term recordings of 5 minutes. K-ARS and ADS are used for screening and identifying ADHD children. Intelligence was measured using Korean educational Developmental Institute-wechsler Intelligence Scale for Children. The caregivers Complete Parenting Stress Index scale for evaluation parent stress. Results:The low frequency(LF) was significantly correlated with response variability of ADS. However, the other variables of ARS and ADS were not significantly correlated with LF. Hyperactivity subscale of ARS was significantly correlated with parental distress subscale and difficult child subscale of PSI-SF and inattention subscale of ARS was also significantly correlated with dysfunctional interaction and difficult child subscale of PSI-SF. Conclusion:The LF, 0.10-Hz component of HRV is known to measure effort allocation. This study shows that the LF component of HRV is significantly correlated with the response variability of ADS. This means that more severe symptoms of ADHD were correlated with the increase in the LF that means decreased effort allocation. These results also support the clinical usability of HRV in the assessment of ADHD. Furthermore, PSI-SF is correlated with hyperactivity and inattention variables of ARS.

  • PDF

Reliability of a Questionnaire for Evaluation of Dry Mouth Symptoms (구강건조증 증상 평가를 위한 설문지의 신뢰도에 관한 연구)

  • Lee, Jeong-Yun;Lee, Young-Ok;Kho, Hong-Seop
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.4
    • /
    • pp.383-389
    • /
    • 2005
  • Xerostomia is defined as a subjective complaint of dry mouth that may be perceived when there is insufficient mucosal wetting. However, the diagnosis and treatment of xerostomia is not that simple because of the fact that the subjective awareness of dry mouth is not always correlated with a diminution in the flow of saliva and there is always a difference between individuals in salivary flow rates needed for normal oral function. In the present study, the aim was to develop a questionnaire to evaluate the dry mouth symptoms and to analyze its reliability and usability as a diagnostic and analytic tool for xerostomia. The questionnaire which consists of 6 Visual Analogue Scale(VAS) type questions to evaluate the subjective oral dryness and 4 questions to evaluate behavior to avoid oral dryness was developed and administered twice with 1 week's interval to the healthy 88 young adults without dry mouth symptoms(44 males and 44 females; mean age was $25.6{\pm}3.1$ years in male and $24.3{\pm}2.1$ years in female). The results were as follows. 1 The intraclass correlation coefficients of 6 questions to evaluate the subjective oral dryness were as significantly high as 0.767 for the degree of oral dryness at other times of the day, 0.850 for the amount of saliva in the mouth, and 0.791 for the degree of effect on daily life due to oral dryness and as high as 0.563 for the degree of oral dryness at night or on awakening, 0.674 for the degree of oral dryness during eating, and 0.641 for the degree of difficulty in swallowing foods. 2. Cronbach's alpha value of 6 questions was 0.982. It can be concluded that the series of questions to evaluate the subjective oral dryness has high internal consistency. 3. Cohen's kappa values of 4 questions to evaluate behavior to relieve oral dryness were as significantly high as 0.850 for the frequency of keeping a glass of water at the bedside and as high as 0.506 the frequency of awakening during sleeping due to oral dryness, 0.419 for the frequency of sipping liquids to aid in eating dry foods, and 0.407 for the frequency of using a candy or chewing gum due to oral dryness. From the results, it can be concluded that the questionnaire consisting of 6 VAS type questions to evaluate the subjective oral dryness and 4 questions to evaluate behavior to relieve oral dryness has reliability of good to excellent level, and that the series of 6 VAS type questions has significantly high internal consistency to evaluate the subjective oral dryness.

The Usability Evaluation of the Usefulness of Bismuth Shields in PET/CT Examination (PET/CT 검사에서 비스무스(bismuth) 차폐체의 적용에 따른 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Ji-Hyeon;Nam, Kun-Sik;Lyu, Kwang-Yeul;Lee, Tae Soo
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.49-56
    • /
    • 2014
  • Recently with CT developed, various studies for reduction of exposure dose is underway. Study of bismuth shields in these studies is actively underway, and has already been applied in the clinical. However, the application of the PET/CT examination was not activated. Therefore, through this study, depending on the application of bismuth shields in the PET/CT examination, we identify the quality of the image and the impact on the Standard Uptake Value (SUV). In this study, to apply to the shielding of the breast, by using the bismuth shields that contains 0.06 mm Pb ingredients, was applied to the PET/CT GEMINI TF 64 (Philips Healthcare, Cleveland, USA). Phantom experiments using the NEMA IEC Body Phantom, images were acquired according to the presence or absence of bismuth shields apply. Also, When applying, images were obtained by varying the spacing 0, 1, 2 cm each image set to the interest range in the depth of the phantom by using EBW-NM ver.1.0. When image of the PET Emission acquires, the SUV was in increased depending on the use of bismuth shields, difference in the depth to the surface from deep in the phantom increasingly SUV increased (P<0.005). Also, when using shields, as the more gab decreased, SUV is more increased (P<0.005). Through this study, PET/CT examination by using of bismuth shields which is used as purpose of reduction dose. When using shields, the difference of SUV resulting from the application of bismuth shields exist and that difference when gab is decrease and surface is wider. Therefore, setting spacing of shield should be considered, if considering the reduction of the variation of SUV and image quality, disease of deep organs should be a priority rather than superficial organ disease. Use of bismuth shielding factor considering the standard clinical examination, decrease unnecessary exposure can be expected to be considered.