• Title/Summary/Keyword: Urinary balloon catheter

Search Result 7, Processing Time 0.018 seconds

Alternative Use of Inferior Blow-out Fracture Reduction with Urinary Balloon Catheter (풍선 달린 카테터를 이용한 안저 파열 골절 정복의 선택적 사용)

  • Park, Sung Hoon;Yang, Ho Jik
    • Archives of Plastic Surgery
    • /
    • v.34 no.6
    • /
    • pp.729-734
    • /
    • 2007
  • Purpose: The operative treatment for blow-out fracture involves restoration of intra-orbital soft tissue and bony structural integrity. There are several methods for reconstruction of inferior blow out fracture. We report reduction of inferior blow-out fracture with urinary balloon catheter in comparison with $Medpor^{(R)}$ using group to complication rate. Methods: A retrospective study was performed on 67 patients who underwent inferior orbital blow-out fracture reconstruction with $Medpor^{(R)}$ implant or urinary balloon catheter following between 2003 and 2006. Hospital records were reviewed especially for preoperative and postoperative enophthalmos, diplopia, extraocular muscle movement limitations, and hypoesthesia between $Medpor^{(R)}$ implant group and balloon catheter using group. Results: There was no significant statistical difference between both groups on incidence of postoperative complications of enophthalmos, diplopia, extraocular muscle movement limitations, and hypoesthesia. Postoperative infection, ectropion were absent in both groups.Conclusion: The use of urinary balloon catheter is simple, fast and inexpensive. Urinary balloon catheter is an alternative and reliable use for reduction of inferior orbital blow-out fracture.

Orbital Floor Reconstruction Using Endoscope and Selected Urethral Balloon Catheter (내시경과 선택적 도뇨관 풍선을 이용한 안와하벽복원술)

  • Choi, Hwan-Jun;Lee, Joo-Chul;Lee, Hyung-Gyo;Kim, Jun-Hyuk
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.35-42
    • /
    • 2011
  • Purpose: Blow-out fractures can be reduced using various methods. The orbital reconstruction technique using a balloon under endoscopic control has advantages over other methods. However, this method has some problems too, such as postoperative follow-up, management of the balloon catheter, and reduction of the posterior orbital floor. Thus, we developed a simple, effective method for orbital floor reduction that involves molding and shaping the antral balloon catheter. Methods: A 0, 30, or $70^{\circ}$, 4-mm endoscope was placed though a two-point, 5-mm maxillary antrostomy. The balloon catheter is placed directly at the orbital apex to reconstruct the anterior shelf (spherical shape), while it is turned in a U-shape towards the anterior maxilla for the posterior shelf (elliptical shape). Orbital floor defects, compound or comminuted fractures are reconstructed with alloplastic materials through an open lid incision under the endoscopic control. Results: This technique was applied to ten patients with orbital floor fractures: five anterior shelf and five posterior shelf fracture, respectively. Four of the patients had zygomatico-orbital fractures, while the rest had isolated orbital floor fractures. Two patients were given porous polyethylene implants Synpor$^{(R)}$) and three underwent reconstruction with a resorbable mesh plate. No complication associated with this technique was identified. Conclusion: The freestyle placement and selection of a urinary balloon catheter under endoscopic control and the preoperative estimation of the volume enhanced the stabilization of the orbital contour. This method improves the adaptation of the orbital floor without the risk of injuring the surrounding orbital contents, dissecting blindly, or using sharp traction. One drawback of this method is the patient's discomfort from the catheter during treatment.

Reconstruction of the Orbital Floor Fracture using the Antral Balloon Catheter with Radiopaque Dye (안저골절 정복술 후 풍선 달린 카테터와 방사선조영제의 이용)

  • Choi, Hwan-Jun;Lee, Han-Jung;Yang, Hyung-Eun;Lee, Young-Man
    • Archives of Plastic Surgery
    • /
    • v.37 no.1
    • /
    • pp.99-103
    • /
    • 2010
  • Purpose: Blow-out fractures are reduced through transcutaneous or transconjunctival incisions. But the field of orbital surgery is difficult due to lack of visualization of fracture site, blind dissection of orbital floor, susceptibility of injury of orbital structures. In these situations, the former technique of using an antral balloon catheter has advantages over other methods for reconstruction because of its rapidity, simplicity, and inexpensiveness. Furthermore, the antral balloon catheter allows not only elevation of the orbital bone fragment but also expansion of the maxillary sinus in cases where there is a fracture of its walls. But postoperative follow-up method using computed tomography is expensive. Hence, we report a simple and inexpensive follow-up method using radiopaque dye inflation. Methods: We performed endoscopic transantral approach in 5 cases of blow-out fracture under general anesthesia. To accomplish this technique, a rigid 4 mm, 0 or 30 degree angled endoscopy was inserted into the maxillary sinus. Inflation of the catheter started gradually, with 10 to 15 mL of saline mixed radiopaque dye (saline: dye, 5 : 1) by syringe and while observing the elevation of the fracture site with endoscope until a proper contour was reached. For the maintain of the position of fractured site, 12 French urinary balloon foley catheter were used in fracture site for 7 - 10 days. Results: Postoperative assessment was performed by means of clinical and simple radiographic examination to secure the catheter under the inferior orbital wall and in the maxillary sinus. No specific complications occurred related to this procedure. Results of the surgery and follow-up in all cases were satisfactory. Conclusion: It may be a better alternative to the conventional follow-up method, with less cost and effectiveness of the catheter patency. The advantages of using the urinary balloon foley catheter with the radiopaque dye include the following : it is safe, efficacy, simple, and especially low cost. On drawback of this method is the discomfort to the patient caused by the catheter during the treatment.

Inferior Blow-Out Fracture Reduction Using Two Urinary Balloon Catheters

  • Jo, Eun Jun;Kim, Jong Hwan;Yang, Ho Jik
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.3
    • /
    • pp.114-118
    • /
    • 2015
  • Background: The reduction of orbital blowout fracture primarily aims to normalize the extra-ocular movement by returning the herniated orbital soft tissue into the original position, and to prevent enophthalmos by normalizing the orbital cavity volume. We introduce a balloon catheter-assisted orbital floor reduction technique. Methods: A retrospective review was performed for all patients with orbital floor fracture who underwent the technique described in the main body of this text. Medical records were reviewed for demographic data, clinical presentation and course, degree of enophthalmos, intraorbital volume on computed tomography scan, and postoperative outcomes. The enophthalmos and intraorbital volume of the injured site were compared to the uninjured eye and orbit. Results: The review identified 14 patients (11 male, 3 female). The mean preoperative difference in en-exopthalmos was 2.13 mm, while the mean orbital volume was 116%. The mean postoperative difference in en-exophthalmos had improved to 0.61 mm with a mean orbital volume of 101.85%. At the time of catheter removal at 10 days, three patients experienced diplopia (n=1), extra-ocular movement disorder (1), or enophthalmos (1). All of these had resolved by the 6-month follow-up visit. Conclusion: Balloon catheter-assisted reduction of the orbital floor fractures was associated with improvements in intraorbital volume and enopthalmos in the 14 patients. Notable complications included diplopia, enophthalmos, and limited extra-ocular movement, all of which were transient in the early postoperative period and had resolved by 6-month follow up.

Reduction of the Isolated Anterior Wall of the Maxillary Sinus Fracture with Double Urinary Balloon Catheters and Fibrin Glue

  • Kim, Jaehee;Yang, Ho Jik;Kim, Jong Hwan;Kim, Su Jin
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.4
    • /
    • pp.238-242
    • /
    • 2017
  • Background: Conservative treatment is performed for isolated anterior wall of the maxillary sinus fractures, in many cases when the fracture is clinically not severe and asymptomatic. Despite the absence of symptoms, complications such as sinusitis, rhinitis, and chronic purulent secretion may develop; therefore, successful reduction is required. We attempted to reduce the risk of complications using an alternative technique: reduction of the fracture with two urinary balloon catheters inserted through the maxillary ostium and fixation using fibrin glue, which minimizes the damage to the bony fragments and sinus mucosa. Methods: In this study, 38 patients who were diagnosed with an isolated anterior wall of the maxillary sinus fracture at our hospital between January 2014 and January 2017 were enrolled. The fracture site was exposed via the Caldwell-Luc approach followed by reduction through the insertion of two urinary balloon catheters using a nasal endoscope and fixation with fibrin glue. The sex, cause of fracture, physical examination, and presence of complications were examined and patient's medical records and facial bone computed tomography scans were analyzed. Results: Radiological evaluation showed that there was no evidence of collapsed reduction fragments. Although some patients had remaining symptoms of hypoesthesia (15%; 3 patients), there were no complications such as infection, rhinitis, sinusitis, and chronic purulent secretion at the surgical site. Conclusion: In this study, we present an alternative surgical technique using two urinary balloon catheters and fibrin glue for the successful reconstruction of an isolated anterior wall of the maxillary sinus fracture. This technique enables precise restoration with a reduced risk of complications.

Spontaneous Perinephric Urinoma after the Removal of a Foley Catheter in a Girl with Acute Kidney Injury (급성 신부전 환아에서 유치 도뇨관 제거 후 발생한 신 주위 요낭종 1례)

  • Yang, Tae Hwan;Yim, Hyung Eun;Yoo, Kee Hwan
    • Childhood Kidney Diseases
    • /
    • v.17 no.2
    • /
    • pp.127-131
    • /
    • 2013
  • Urinomas can occur after renal trauma or perforation of the collecting system during an endosurgical procedure. However, spontaneous urinomas are very rare. Here we report a case of a spontaneous perinephric urinoma following the removal of a Foley catheter in an 18-year-old girl with acute kidney injury caused by septic shock. The patient had been treated for septic shock, acute kidney injury, and acute respiratory distress syndrome, and had a Foley catheter in place for seven days. After Foley catheter removal, the patient complained of consistent voiding difficulty. An abdominal computed tomography scan showed a large amount of left perinephric fluid, and the aspirated fluid included urothelial cells, confirming the diagnosis of a urinoma. The urinoma was successfully treated by insertion of a double-J stent into the left ureter. This report discusses the available literature on urinomas, and their clinical features, diagnosis, and treatment.

Clinical Experience of Continuous Epidural Analgesia Using Baxter $Infusor^{(R)}$ (Baxter $Infusor^{(R)}$를 이용한 경막외 진통제 지속 주입)

  • Bae, Sang-Chull;Lee, Jang-Won;Kim, Ill-Ho;Song, Hoo-Bin;Park, Wook;Kim, Sung-Yell
    • The Korean Journal of Pain
    • /
    • v.4 no.2
    • /
    • pp.127-132
    • /
    • 1991
  • Recently a non-electronic, disposable and portable infusor(Baxter infusor with patient control module, Baxter health care Co., Deerfield IL 60015 USA: BI $\bar{c}$ PCM) has been developed that will deliver both a continuous drug infusion as well as allow the patient to deliver extra doses of medication on a demand basis under predetermined limitation of analgesics. Patients may also not require as high analgesic dose rate to control pain when the acceptable and tolerable level of pain relief can be maintained by this device. From April l99l, we have used a total l93 units of BI $\bar{c}$ PCM. These units consisting of two components which one made by a balloon reservoir(capacity 65 ml, flow rate 0.5 ml/hr) to store medication and to regulate the pump power(490 torr), and another two PCMs to regulate additional analgesic administration by patients demand at intervals of 1S minutes and 60 minutes. The dose administered to the patient can be varied by changing the concentration of the infusate within the balloon reservoir. These devices were utilized for the pain control of 44 patients. These patients were divided into two groups. Twenty seven cases had cancer pain and 17 cases had non-cancer pain. The Touhy needle(No. l8 G.) tip was inserted into the epidural space and was used to guide the catheter to the spinal nerve level corresponding to the most painful area. The device was connected to the opposite site of the catheter tip and was filled with 60 ml of mixture solution such as 0.5% bupivacaine 15 ml, morphine HCl 10 mg, trazodone 10 ml, Tridol 3 ml and normal saline 31 ml were administed as the initial dose. When the initial dose was less effective, the next dose could be varied by increasing the concentration of bupivacaine, by adding more morphine (5~10 mg), and by reducing the volume of normal saline. Using these modules of drug self administration, we experienced the following: 1) Improvement of patient's self titration of analgesic requirement was provided. 2) The patients anxiety with pain recurrence resulting from delays in administering pain control medication was decreased significantly. 3) The working load accompanying with the single bolus injection as the usual method was reduced remarkably. 4) There was urinary retention in 5 cases and pruritus in 4 eases which developed as side effects but respiratory depression and vomiting was not encountered in a single case.

  • PDF