Purpose: The operative treatment for blow-out fracture involves restoration of intra-orbital soft tissue and bony structural integrity. There are several methods for reconstruction of inferior blow out fracture. We report reduction of inferior blow-out fracture with urinary balloon catheter in comparison with $Medpor^{(R)}$ using group to complication rate. Methods: A retrospective study was performed on 67 patients who underwent inferior orbital blow-out fracture reconstruction with $Medpor^{(R)}$ implant or urinary balloon catheter following between 2003 and 2006. Hospital records were reviewed especially for preoperative and postoperative enophthalmos, diplopia, extraocular muscle movement limitations, and hypoesthesia between $Medpor^{(R)}$ implant group and balloon catheter using group. Results: There was no significant statistical difference between both groups on incidence of postoperative complications of enophthalmos, diplopia, extraocular muscle movement limitations, and hypoesthesia. Postoperative infection, ectropion were absent in both groups.Conclusion: The use of urinary balloon catheter is simple, fast and inexpensive. Urinary balloon catheter is an alternative and reliable use for reduction of inferior orbital blow-out fracture.
Purpose: Blow-out fractures can be reduced using various methods. The orbital reconstruction technique using a balloon under endoscopic control has advantages over other methods. However, this method has some problems too, such as postoperative follow-up, management of the balloon catheter, and reduction of the posterior orbital floor. Thus, we developed a simple, effective method for orbital floor reduction that involves molding and shaping the antral balloon catheter. Methods: A 0, 30, or $70^{\circ}$, 4-mm endoscope was placed though a two-point, 5-mm maxillary antrostomy. The balloon catheter is placed directly at the orbital apex to reconstruct the anterior shelf (spherical shape), while it is turned in a U-shape towards the anterior maxilla for the posterior shelf (elliptical shape). Orbital floor defects, compound or comminuted fractures are reconstructed with alloplastic materials through an open lid incision under the endoscopic control. Results: This technique was applied to ten patients with orbital floor fractures: five anterior shelf and five posterior shelf fracture, respectively. Four of the patients had zygomatico-orbital fractures, while the rest had isolated orbital floor fractures. Two patients were given porous polyethylene implants Synpor$^{(R)}$) and three underwent reconstruction with a resorbable mesh plate. No complication associated with this technique was identified. Conclusion: The freestyle placement and selection of a urinary balloon catheter under endoscopic control and the preoperative estimation of the volume enhanced the stabilization of the orbital contour. This method improves the adaptation of the orbital floor without the risk of injuring the surrounding orbital contents, dissecting blindly, or using sharp traction. One drawback of this method is the patient's discomfort from the catheter during treatment.
Purpose: Blow-out fractures are reduced through transcutaneous or transconjunctival incisions. But the field of orbital surgery is difficult due to lack of visualization of fracture site, blind dissection of orbital floor, susceptibility of injury of orbital structures. In these situations, the former technique of using an antral balloon catheter has advantages over other methods for reconstruction because of its rapidity, simplicity, and inexpensiveness. Furthermore, the antral balloon catheter allows not only elevation of the orbital bone fragment but also expansion of the maxillary sinus in cases where there is a fracture of its walls. But postoperative follow-up method using computed tomography is expensive. Hence, we report a simple and inexpensive follow-up method using radiopaque dye inflation. Methods: We performed endoscopic transantral approach in 5 cases of blow-out fracture under general anesthesia. To accomplish this technique, a rigid 4 mm, 0 or 30 degree angled endoscopy was inserted into the maxillary sinus. Inflation of the catheter started gradually, with 10 to 15 mL of saline mixed radiopaque dye (saline: dye, 5 : 1) by syringe and while observing the elevation of the fracture site with endoscope until a proper contour was reached. For the maintain of the position of fractured site, 12 French urinary balloon foley catheter were used in fracture site for 7 - 10 days. Results: Postoperative assessment was performed by means of clinical and simple radiographic examination to secure the catheter under the inferior orbital wall and in the maxillary sinus. No specific complications occurred related to this procedure. Results of the surgery and follow-up in all cases were satisfactory. Conclusion: It may be a better alternative to the conventional follow-up method, with less cost and effectiveness of the catheter patency. The advantages of using the urinary balloon foley catheter with the radiopaque dye include the following : it is safe, efficacy, simple, and especially low cost. On drawback of this method is the discomfort to the patient caused by the catheter during the treatment.
Background: The reduction of orbital blowout fracture primarily aims to normalize the extra-ocular movement by returning the herniated orbital soft tissue into the original position, and to prevent enophthalmos by normalizing the orbital cavity volume. We introduce a balloon catheter-assisted orbital floor reduction technique. Methods: A retrospective review was performed for all patients with orbital floor fracture who underwent the technique described in the main body of this text. Medical records were reviewed for demographic data, clinical presentation and course, degree of enophthalmos, intraorbital volume on computed tomography scan, and postoperative outcomes. The enophthalmos and intraorbital volume of the injured site were compared to the uninjured eye and orbit. Results: The review identified 14 patients (11 male, 3 female). The mean preoperative difference in en-exopthalmos was 2.13 mm, while the mean orbital volume was 116%. The mean postoperative difference in en-exophthalmos had improved to 0.61 mm with a mean orbital volume of 101.85%. At the time of catheter removal at 10 days, three patients experienced diplopia (n=1), extra-ocular movement disorder (1), or enophthalmos (1). All of these had resolved by the 6-month follow-up visit. Conclusion: Balloon catheter-assisted reduction of the orbital floor fractures was associated with improvements in intraorbital volume and enopthalmos in the 14 patients. Notable complications included diplopia, enophthalmos, and limited extra-ocular movement, all of which were transient in the early postoperative period and had resolved by 6-month follow up.
Kim, Jaehee;Yang, Ho Jik;Kim, Jong Hwan;Kim, Su Jin
대한두개안면성형외과학회지
/
제18권4호
/
pp.238-242
/
2017
Background: Conservative treatment is performed for isolated anterior wall of the maxillary sinus fractures, in many cases when the fracture is clinically not severe and asymptomatic. Despite the absence of symptoms, complications such as sinusitis, rhinitis, and chronic purulent secretion may develop; therefore, successful reduction is required. We attempted to reduce the risk of complications using an alternative technique: reduction of the fracture with two urinary balloon catheters inserted through the maxillary ostium and fixation using fibrin glue, which minimizes the damage to the bony fragments and sinus mucosa. Methods: In this study, 38 patients who were diagnosed with an isolated anterior wall of the maxillary sinus fracture at our hospital between January 2014 and January 2017 were enrolled. The fracture site was exposed via the Caldwell-Luc approach followed by reduction through the insertion of two urinary balloon catheters using a nasal endoscope and fixation with fibrin glue. The sex, cause of fracture, physical examination, and presence of complications were examined and patient's medical records and facial bone computed tomography scans were analyzed. Results: Radiological evaluation showed that there was no evidence of collapsed reduction fragments. Although some patients had remaining symptoms of hypoesthesia (15%; 3 patients), there were no complications such as infection, rhinitis, sinusitis, and chronic purulent secretion at the surgical site. Conclusion: In this study, we present an alternative surgical technique using two urinary balloon catheters and fibrin glue for the successful reconstruction of an isolated anterior wall of the maxillary sinus fracture. This technique enables precise restoration with a reduced risk of complications.
요낭종이란 신장 및 비뇨기계로부터 누출된 소변이 신장 및 신우 주위에 캡슐상의 낭종을 형성하는 드문 질환으로 자연발생적인 신우의 파열로 인한 누출은 매우 드물며, 대부분 요로와 신우 내강의 압력 증가에 의해 발생한다. 본 증례에서 18세 여자 환아는 내원 7일 전부터 시작된 고열과 핍뇨 및 호흡곤란을 주소로 내원하였다. 환아는 출생시 다운 증후군을 진단받았으며 평소 배뇨는 원활하였다. 입원 후 환아는 패혈증 쇼크 및 급성 신손상, 급성 호흡 곤란 증후군 진단 하에 항생제 및 스테로이드 충격 요법 시행 후 핍뇨, 호흡곤란 및 혈액검사 호전 소견 보였으나 7일 동안 유치된 도뇨관 제거 후 환아는 요 폐색 소견이 관찰되었다. 복부 전산화 단층 촬영상 좌측 신장 주위에 요낭종이 확인되어 좌측 요관에 Double-J catheter가 삽입 되었으며 신우의 파열 부위에 조영제 누출이 확인되었다. 시술 후 요 폐색 소견은 호전되었고, 배뇨성 방광 요도 조영술 상 좌측 신장의 4단계 방광 요관 역류가 관찰되었다. Double-J catheter 제거 3개월 후 좌측 신장 주변의 요낭종은 대부분 소실되었고, 좌측 신장의 방광 요관 역류는 보이지 않았다. 저자들은 급성 신부전 환아에서 유치 도뇨관 제거 후 배뇨곤란 및 요 폐색 소견을 보인 신 주위 요낭종 1례를 경험하였기에 보고하는 바이다.
Recently a non-electronic, disposable and portable infusor(Baxter infusor with patient control module, Baxter health care Co., Deerfield IL 60015 USA: BI $\bar{c}$ PCM) has been developed that will deliver both a continuous drug infusion as well as allow the patient to deliver extra doses of medication on a demand basis under predetermined limitation of analgesics. Patients may also not require as high analgesic dose rate to control pain when the acceptable and tolerable level of pain relief can be maintained by this device. From April l99l, we have used a total l93 units of BI $\bar{c}$ PCM. These units consisting of two components which one made by a balloon reservoir(capacity 65 ml, flow rate 0.5 ml/hr) to store medication and to regulate the pump power(490 torr), and another two PCMs to regulate additional analgesic administration by patients demand at intervals of 1S minutes and 60 minutes. The dose administered to the patient can be varied by changing the concentration of the infusate within the balloon reservoir. These devices were utilized for the pain control of 44 patients. These patients were divided into two groups. Twenty seven cases had cancer pain and 17 cases had non-cancer pain. The Touhy needle(No. l8 G.) tip was inserted into the epidural space and was used to guide the catheter to the spinal nerve level corresponding to the most painful area. The device was connected to the opposite site of the catheter tip and was filled with 60 ml of mixture solution such as 0.5% bupivacaine 15 ml, morphine HCl 10 mg, trazodone 10 ml, Tridol 3 ml and normal saline 31 ml were administed as the initial dose. When the initial dose was less effective, the next dose could be varied by increasing the concentration of bupivacaine, by adding more morphine (5~10 mg), and by reducing the volume of normal saline. Using these modules of drug self administration, we experienced the following: 1) Improvement of patient's self titration of analgesic requirement was provided. 2) The patients anxiety with pain recurrence resulting from delays in administering pain control medication was decreased significantly. 3) The working load accompanying with the single bolus injection as the usual method was reduced remarkably. 4) There was urinary retention in 5 cases and pruritus in 4 eases which developed as side effects but respiratory depression and vomiting was not encountered in a single case.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.