• Title/Summary/Keyword: Urban noise

Search Result 447, Processing Time 0.033 seconds

An study on the Effects of Visual and Aural Information on Environmental Sound Amenity Evaluation (시각 및 청각 정보가 환경음의 쾌적성 평가에 미치는 영향에 관한 연구)

  • Shin, Hoon;Baek, Kun-Jong;Song, Min-Jeong;Jang, Gil-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.9
    • /
    • pp.813-818
    • /
    • 2007
  • This study aims to know the effect of road traffic noise perception when the visual and aural information is added in a laboratory experiment. ME (magnitude estimation) and SD (semantic differential method) evaluation on the effect of visual and aural effect were carried out by 43 university students. As the result, up to 10 % of psychological reduction effect was shown under the 65 dB(A). As the noise level, it was analyzed that the vision affected about 7 dB(A) and sound affected 5 dB(A). However, if these two are given simultaneously, mainly sound affects to reduce the annoyance of noise and the vision next. Compared with the urban central circumstances, this effect (2 dB(A) under 65 dB(A) noise) was shown smaller than field test.

A study on Fairing System for Traveling Noise Reduction in Urban Subway (도시철도 운행소음 저감용 훼어링시스템 연구)

  • Choi, Sang-Chun;Jang, Won-Rak;Ho, Kyoung-Chan
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.659-666
    • /
    • 2009
  • As the density and height of the buildings nearby subway lines get higher, the unprecedented residents' appeals for noise are on the rise. Furthermore, in accordance with the revision of enforcement regulations on the Noise and Vibration Control Act, the night time noise standards have been reinforced by 5dB effective on January 1st 2010 and the appropriate measures shall be taken accordingly. For the settlement of the public grievances against noise and vibration generated on tracks in at-grade and elevated section, the installation of continuously-welded-rail, rail lubrication system, improved fastening system and higher noise barrier is currently executed. Nevertheless, the noise and vibration levels in some areas are still exceeding the limits required in the regulation. Among the measures, an installation of higher noise barrier or noise tunnel seems to be the most effective way; however, it has limitations owing to the structural stability of existing elevated structures. The paper in consideration of the local conditions and foreign practices discusses the installation of fairing system under the train body as an noise insulation panel in order to reduce the rolling noise and under-carriage noise. Based on the result of this study, a performance verification test during actual train operation is in progress for further study.

  • PDF

A Case of Application-blasting in the Urban Blasting Works (도심지 터파기를 위한 응용발파 시공 사례)

  • Kim, Taihyun;Park, Yongwon;Cho, Raehun;Kim, Hongyool;Jeong, Byungho
    • Explosives and Blasting
    • /
    • v.34 no.2
    • /
    • pp.18-30
    • /
    • 2016
  • A drill & blasting method using explosives is the most efficient way to break the rock in the urban projects. However, the blasting method cause vibration, noise and fly-rock as blast pollutions so that blasting wroks are restricted by adjacent structures such as apartment and residence houses. To conduct blasting works at near structures, the numbers of blast-holes a blast and the size of the blast are limited by kinds of detonators and initiation methods. So, the production rate is reduced and the construction period should be increased. Therefore, in this case the deck-charge blasting methods using available detonators in domestic market were designed and evaluated in order to confirm the application possibilities in specific urban sites.

Bearing Capacity of Mid & Small dia Hellical Pile (중·소구경 헬리컬 파일의 지지력 특성)

  • Park, Jong-Bae;Park, Yong-Boo;Kwon, Young-Hwan
    • Land and Housing Review
    • /
    • v.11 no.2
    • /
    • pp.75-86
    • /
    • 2020
  • As the urban regeneration project and the old housing maintenance project are actively progressing in Korea, small-scale building construction is being carried out in downtown areas. Small buildings in the downtown area are constructed on about 4 to 10 floors, and since they are carried out in small units in residential areas, it is difficult to enter large equipment to construct existing piles, and it is more vulnerable to complaints about noise and vibration. in this study, helical piles suitable for urban areas or small sites where it is difficult to enter large equipment, such as noise and vibration. Reliability analysis was performed on the results of the static load tests and dynamic load tests conducted at the LH site and the bearing capacity calculated by the hydrostatic method and the empirical formula (N value). As a result of comparing and analyzing the design formula and the results of static load test and dynamic load tests, the correlation between the design formula of the bored pile (Road bridge design standard) formula using N value and the design formula by the modified Davisson method frequently used by method commonly European helical file practitioners.

Analysis of Vehicle Limit Considering the Dynamic Behavior for an Urban Train (도시철도 차량의 동적거동을 고려한 차량한계 해석)

  • 박찬경;김영국;배대성
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.7
    • /
    • pp.527-533
    • /
    • 2002
  • A railway vehicle should be satisfied with the safety criteria and ride comfort of passengers. A bogie of railway vehicle Is composed of many suspension components, such as springs, dampers and etc.. that have an influence on the dynamic behavior of the train wish the wheel/rail profiles and track geometries. Therefore, it Is necessary for engineers to check the Interference between vehicle limit and construction limit with considering the vehicle's behavior, because when the vehicle is running on curved track, it should be have enough clearance from infrastructure for safely, spacially In a subway system. This paper explains the effective method of analysis for vehicle limit considering the vehicle dynamic behavior and reviews the problem of vehicle limit for the Korean Standard Urban Train. The results show that the vehicle limit is over the construction limit when the Korean Standard Urban Train runs on the curved track with 180 m radius of curve.

A Study on the Application of Human Factors to the Introduction of PAV & UAM

  • Ahn, Kyung Su;Jeong, Won Kyong
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.28 no.4
    • /
    • pp.171-175
    • /
    • 2020
  • The present and future cities are expanding, and the noise and environmental pollution in cities are getting worse day by day, causing saturation of road and subway traffic. As a result, citizens are spending a great deal of time and money. The use of the sky as a measure to solve this problem has become a reality. However, airplanes that require airstrips and noisy helicopters are difficult to use in cities. As a solution, PAVs and UAMs that generate low noise and enable vertical takeoff and landing using electric energy, motor, hybrid, and hydrogen energy, are attracting attention, with its practicality being promoted in many countries. The development of urban environment and technology has led to the emergence of Personal Air Vehicle (PAV), Vertical Takeoff and Landing (eVTOL), and Urban Air Mobility (UAM) for shipping. Though currently at the level of testing, general commercialization of these air transport means is expected in the next five to fifteen years. This study suggests a plan on the application of human factors to the introduction of PAV and UAM.

The Study on an Electric Noise Effect using Physical Scale Modeling (축소모형 실험을 이용한 전기적 잡음에 관한연구)

  • Yun, Jeum-Dong;Song, Young-Su;So, Kyung-Mok
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.297-302
    • /
    • 2007
  • Recently, electrical resistivity survey is used in the various fields and applied to urban area with many electrical noises. Therefor it's necessary to observe the electrical noise effect of the geological structure. The physical scale modeling was conducted for measuring the electric noise effect of the two geological models at various distances, depths and diameters of the electric noise objects. The results are as following. 1. When conductive noise object was vertical to the strike of geological structure and moved to the strike direction, the effect of conductive noise object at various separated distances to the measurement line was disappeared at a half distance measurement line length regardless of electrode arrays. 2. When conductive noise object was vertical to the strike of geological structure and moved to the strike direction, the effect of conductive noise object at various depths was disappeared at 4unit apart from the measurement line regardless of electrode arrays. 3. When conductive noise object was vertical to the strike of geological structure and moved to the strike direction, the effect of conductive noise object at various diameters was disappeared at 4unit apart from the measurement line regardless of electrode arrays.

  • PDF

The Analysis of Musle Fatigue for Urban Bus Driver using Electromyography (근전도를 이용한 시내버스 운전자 피로도 분석)

  • Kim, Kyong;Kim, Jae-Jun;Lee, Chan-Ki;Kim, Dong-Won;Kwon, Tae-Kyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.584-590
    • /
    • 2009
  • Since driving include compilcated actions that require a variety of abillity and cause extrme concentration or strain, divers tend to feel tired easiy. However, divers can't recognize fatigue degree by himself and accordingly the methods to measure quantitative fatigue degree exactly is quite difficult to be secured. In this study, the most efficient driving posture was suggested based on the analysis of quantitative muscular strength and fatigue degree according to posture. The driver whom we experimented included 9 commercial bus drivers. We also analyzed quantitative legs' muscular strength according te operating each pedal, left and right then we analyzed muscular strength and muscular fatigue degree according to driving pattern while driving commercial buses. And then we suggested the most efficient driving posture.

  • PDF

A Study on the Sound Absorption effect of Concrete track the Sound Absorption Blocks in Urban Transit (도시철도 콘크리트 궤도의 흡음블럭이 소음저감에 미치는 영향)

  • Yoo, Sang-Bum;Lee, An-Ho;Kim, Sang-Jin;Kang, Kee-Dong
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.329-336
    • /
    • 2011
  • Urban transit is promoting improvement of the concrete track to solve many problems maintenance in ballasted track. But concrete track has a lot of noise compared to ballated track by multiple reflections. The concrete track is to install sound absorption blocks to reduce noise. And it has a lot of research and effort. This is study analyzed the effect of sound absorption blocks though field measurements, in the range of installed sound absorption blocks. And this was an analysis of the surface shape and sound absorption effects of sound absorption blocks.

  • PDF

The Vibration Velocity and Vibration Level of Near-field Blasting Vibration in an Urban Blasting Site (근접장 발파진동에서 진동속도와 진동레벨)

  • Lee, Yeon-Soo;Chang, Seo-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.766-771
    • /
    • 2005
  • To compare blasting vibration at blasting construction field in urban area, the vibration level (dB(V)) and vibration velocity (cm/sec) on the ground and the structure of buildings due to the differences of the measuring sites from the blasting source is investigated and the difference between the measured vertical vibration level and the calculated vibration level by using vibration velocity PVS and the correlation between vibration velocity and vibration level and is studied in the thesis.

  • PDF