• Title/Summary/Keyword: Urban heat island

Search Result 338, Processing Time 0.031 seconds

Ventilation Corridor Characteristics Analysis and Management Strategy to Improve Urban Thermal Environment - A Case Study of the Busan, South Korea - (도시 열환경 개선을 위한 바람길 특성 분석 및 관리 전략 - 부산광역시를 사례로 -)

  • Moon, Ho-Yeong;Kim, Dong-Pil;Gweon, Young-Dal;Park, Hyun-Bin
    • Korean Journal of Environment and Ecology
    • /
    • v.35 no.6
    • /
    • pp.659-668
    • /
    • 2021
  • The purpose of this study is to propose a ventilation corridor management plan to improve the thermal environment for Busan Metropolitan City. To this end, the characteristics of hot and cool spots in Busan were identified by conducting spatial statistical analysis, and thermal image data from Landsat-7 satellites and major ventilation corridors were analyzed through WRF meteorological simulation. The results showed the areas requiring thermal environment improvement among hot spot areas were Busanjin-gu, Dongnae-gu, industrial areas in Yeonje-gu and Sasang-gu, and Busan Port piers in large-scale facilities. The main ventilation corridor was identified as Geumjeongsan Mountain-Baekyangsan Mountain-Gudeoksan Mountain Valley. Based on the results, the ventilation corridor management strategy is suggested as follows. Industrial facilities and the Busan Port area are factors that increase the air temperature and worsen the thermal environment of the surrounding area. Therefore, urban and architectural plans are required to reduce the facility's temperature and consider the ventilation corridor. Areas requiring ventilation corridor management were Mandeok-dong and Sajik-dong, and they should be managed to prevent further damage to the forests. Since large-scale, high-rise apartment complexes in areas adjacent to forests interfere with the flow of cold and fresh air generated by forests, the construction of high-rise apartment complexes near Geumjeongsan Mountain with the new redevelopment of Type 3 general residential area should be avoided. It is expected that the results of this study can be used as basic data for urban planning and environmental planning in response to climate change in Busan Metropolitan City.

The Characteristics of Retention and Evapotranspiration in the Extensive Greening Module of Sloped and Flat Rooftops (저토심 경사지붕과 평지붕 녹화모듈의 저류 및 증발산 특성)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.6
    • /
    • pp.107-116
    • /
    • 2013
  • This study was undertaken to investigate the characteristics of retention and evapotranspiration in the extensive greening module of sloped and flat rooftops for stormwater management and urban heat island mitigation. A series of 100mm depth's weighing lysimeters planted with Sedum kamtschaticum. were constructed on a 50% slope facing four orientations(north, east, south and west) and a flat rooftop. Thereafter the retention and evapotranspiration from the greening module and the surface temperature of nongreening and greening rooftop were recorded beginning in September 2012 for a period of 1 year. The characteristics of retention and evapotranspiration in the greening module were as follows. The water storage of the sloped and flat greening modules increased to 8.7~28.4mm and 10.6~31.8mm after rainfall except in the winter season, in which it decreased to 3.3mm and 3.9mm in the longer dry period. The maximum stormwater retention of the sloped and flat greening modules was 22.2mm and 23.1mm except in the winter season. Fitted stormwater retention function was [Stormwater Retention Ratio(%)=-18.42 ln(Precipitation)+107.9, $R^2$=0.80] for sloped greening modules, and that was [Stormwater Retention Ratio(%)=-22.64 ln(X)+130.8, $R^2$=0.81] for flat greening modules. The daily evapotranspiration(mm/day) from the greening modules after rainfall decreased rapidly with a power function type in summer, and with a log function type in spring and autumn. The daily evapotranspiration(mm/day) from the greening modules after rainfall was greater in summer > spring > autumn > winter by season. This may be due to the differences in water storage, solar radiation and air temperature. The daily evapotranspiration from the greening modules decreased rapidly from 2~7mm/day to less than 1mm/day for 3~5 days after rainfall, and that decreased slowly after 3~5 days. This indicates that Sedum kamtschaticum used water rapidly when it was available and conserved water when it was not. The albedo of the concrete rooftop and greening rooftop was 0.151 and 0.137 in summer, and 0.165 and 0.165 in winter respectively. The albedo of the concrete rooftop and greening rooftop was similar. The effect of the daily mean and highest surface temperature decrease by greening during the summer season showed $1.6{\sim}13.8^{\circ}C$(mean $9.7^{\circ}C$) and $6.2{\sim}17.6^{\circ}C$(mean $11.2^{\circ}C$). The difference of the daily mean and highest surface temperature between the greening rooftop and concrete rooftop during the winter season were small, measuring $-2.4{\sim}1.3^{\circ}C$(mean $-0.4^{\circ}C$) and $-4.2{\sim}2.6^{\circ}C$(mean $0.0^{\circ}C$). The difference in the highest daily surface temperature between the greening rooftop and concrete rooftop during the summer season increased with an evapotranspiration rate increase by a linear function type. The fitted function of the highest daily surface temperature decrease was [Temperature Decrease($^{\circ}C$)=$1.4361{\times}$(Evapotranspiration rate(mm/day))+8.83, $R^2$=0.59]. The decrease of the surface temperature by greening in the longer dry period was due to sun protection by the sedum canopy. The results of this study indicate that the extensive rooftop greening will assist in managing stormwater runoff and urban heat island through retention and evapotranspiration. Sedum kamtschaticum would be the ideal plant for a non-irrigated extensive green roof. The shading effects of Sedum kamtschaticum would be important as well as the evapotranspiration effects of that for the long-term mitigation effects of an urban heat island.

Classification of Wind Corridor for Utilizing Heat Deficit of the Cold-Air Layer - A Case Study of the Daegu Metropolitan City - (냉각에너지를 활용한 바람길 구성요소 분류 - 대구광역시를 사례로 -)

  • Sung, Uk-Je;Eum, Jeong-Hee
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.51 no.5
    • /
    • pp.70-83
    • /
    • 2023
  • Recently, the Korea Forest Service has implemented a planning project about wind corridor forests as a response measure to climate change. Based on this, research on wind corridors has been underway. For the creation of wind corridor forests, a preliminary evaluation of the wind corridor function is necessary. However, currently, there is no evaluation index to directly evaluate and spatially distinguish the types of wind corridors, and analysis is being performed based on indirect indicators. Therefore, this study proposed a method to evaluate and classify wind corridors by utilizing heat deficit analysis as an evaluation index for cold air generation. Heat deficit was analyzed using a cold air analysis model called Kaltluftabflussmodell_21 (KLAM_21). According to the results of the simulation analysis, the wind path was functionally classified. The top 5% were classified as cold-air generating Areas (CGA), and the bottom 5% as cold-air vulnerable Areas (CVA). In addition, the cold-air flowing Areas (CFA) were classified by identifying the flow of cold air moving from the cold air generation area. It is expected that the methodology of this study can be utilized as an evaluation method for the effectiveness of wind corridors. It is also anticipated to be used as an evaluation index to be presented in the selection of wind corridor forest sites.

Management Strategies of Ventilation Paths for Improving Thermal Environment - A Case Study of Gimhae, South Korea - (도시 열환경 개선을 위한 바람길 관리 전략 - 김해시를 사례로 -)

  • EUM, Jeong-Hee;SON, Jeong-Min;SEO, Kyeong-Ho;PARK, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.1
    • /
    • pp.115-127
    • /
    • 2018
  • This study aims to propose management strategies of ventilation paths for improving urban thermal environments. For this purpose, Gimhae-si in Gyeongsangnamdo was selected as a study area. We analyzed hot spots and cool spots in Gimhae by using Landsat 8 satellite image data and spatial statistical analysis, and finally derived the vulnerable areas to thermal environment. In addition, the characteristics of ventilation paths including wind direction and wind speed were analyzed by using data of the wind resource map provided by Korea Meteorological Administration. As a result, it was found that a lot of hot spots were similar to those with weak wind such as Jinyoung-eup, Jillye-myeon, Juchon-myeon and the downtown area. Based on the analysis, management strategies of ventilation paths in Gimhye were presented as follows. Jinyoung-eup and Jillye-myeon with hot spot areas and week wind areas have a strong possibility that hot spot areas will be extended and strengthened, because industrial areas are being built. Hence, climate-friendly urban and architectural plans considering ventilation paths is required in these areas. In Juchon-myeon, where industrial complexes and agricultural complexes are located, climate-friendly plans are also required because high-rise apartment complexes and an urban development zone are planned, which may induce worse thermal environment in the future. It is expected that a planning of securing and enlarging ventilation paths will be established for climate-friendly urban management. and further the results will be utilized in urban renewal and environmental planning as well as urban basic plans. In addition, we expect that the results can be applied as basic data for climate change adaptation plan and the evaluation system for climate-friendly urban development of Gimhye.

Analysis of Water Cycle Effect according to Application of LID Techniques (LID 기법 적용에 따른 물순환 효과분석)

  • Lee, Jungmin;Lee, Yun;Choi, Jongsoo
    • Journal of Wetlands Research
    • /
    • v.16 no.3
    • /
    • pp.411-421
    • /
    • 2014
  • At present, the development in rainwater management approach is still insufficient due to the numerous adverse effects of urbanization. Storm water management is being developed to restore the natural state of water cycle undergoing several processes which were hindered such as infiltration and evapotranspiration. Low Impact Development (LID) was established in order to reduce the negative effects of urbanization to our environment. These developments can be used to respond to the effects of climate change such as heat island phenomenon. The effects of the development of new town in the district plan with application of LID facilities were studied and reported. Typically, LID facilities were applied in small scale development and were rarely used in large-scale development. Most of studies, however, did not assessment the effects of large-scale development projects with LID application to the natural water cycle. This study was conducted to simulate the urban hydrologic cycle simulation on Asan-Tangjeong in Korea. This study may be used in urban hydrologic cycle simulation and establishment of an urban water management plan in the future. Lastly, this study generated a model using the recently updated SWMM5 which determined the hydrologic cycle simulation after installation of LID facilities.

Impacts of Three-dimensional Land Cover on Urban Air Temperatures (도시기온에 작용하는 입체적 토지피복의 영향)

  • Jo, Hyun-Kil;Ahn, Tae-Won
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.3
    • /
    • pp.54-60
    • /
    • 2009
  • The purpose of this study is to analyze the impacts of three-dimensional land cover on changing urban air temperatures and to explore some strategies of urban landscaping towards mitigation of heat build-up. This study located study spaces within a diameter of 300m around 24 Automatic Weather Stations(AWS) in Seoul, and collected data of diverse variables which could affect summer energy budgets and air temperatures. The study also selected reflecting study objectives 6 smaller-scale spaces with a diameter of 30m in Chuncheon, and measured summer air temperatures and three-dimensional land cover to compare their relationships with results from Seoul's AWS. Linear regression models derived from data of Seoul's AWS revealed that vegetation volume, greenspace area, building volume, building area, population density, and pavement area contributed to a statistically significant change in summer air temperatures. Of these variables, vegetation and building volume indicated the highest accountability for total variability of changes in the air temperatures. Multiple regression models derived from combinations of the significant variables also showed that both vegetation and building volume generated a model with the best fitness. Based on this multiple regression model, a 10% increase of vegetation volume decreased the air temperatures by approximately 0.14%, while a 10% increase of building volume raised them by 0.26%. Relationships between Chuncheon's summer air temperatures and land cover distribution for the smaller-scale spaces also disclosed that the air temperatures were negatively correlated to vegetation volume and greenspace area, while they were positively correlated to hardscape area. Similarly to the case of Seoul's AWS, the air temperatures for the smaller-scale spaces decreased by 0.32% ($0.08^{\circ}C$) as vegetation volume increased by 10%, based on the most appropriate linear model. Thus, urban landscaping for the reduction of summer air temperatures requires strategies to improve vegetation volume and simultaneously to decrease building volume. For Seoul's AWS, the impact of building volume on changing the air temperatures was about 2 times greater than that of vegetation volume. Wall and rooftop greening for shading and evapotranspiration is suggested to control atmospheric heating by three-dimensional building surfaces, enlarging vegetation volume through multilayered plantings on soil surfaces.

Assessment of Temperature Reduction and Evapotranspiration of Green Roof Planted with Zoysia japonica (한국잔디식재 옥상녹화의 온도저감 및 증발산량 평가)

  • Kim, Se-Chang;Lee, Hyun-Jeong;Park, Bong-Ju
    • Journal of Environmental Science International
    • /
    • v.22 no.11
    • /
    • pp.1443-1449
    • /
    • 2013
  • This was an experimental study to evaluate temperature reduction and evapotranspiration of extensive green roof. Three test cells with a dimension of $1.2(W){\times}1.2(D){\times}1.0(H)$ meters were built using 4-inch concrete blocks. Ten-centimeter concrete slab was installed on top of each cell. The first cell was control cell with no green roof installed. The second and third cells were covered with medium-leaf type Zoysiagrass (Zoysia japonica) above a layer of soil. Soil thickness on the second cell was 10cm and that on the third cell was 20cm. Air temperature, relative humidity and solar irradiance were measured using AWS (automatic weather system). Temperature on top surface and ceiling of the control cell and temperature on top surface, below soil and ceiling of green roof cells was measured. Evapotranspiration of the green roof cells were measured using weight changes. Compared with temperature difference on the control cell, temperature difference was greater on green roof cells. Between two green roof cells, the temperature difference was greater on the third cell with a thicker soil layer. Temperature differences below soil and on ceilings of green roof cells were found greater than those of the control cell. Between the green roof cells, there was no difference in the temperature reduction effects below soil and on ceilings based on substrate depth. In summary, green roof was found effective in temperature reduction due to evapotranspiration and shading effect.

Urbanization Effect on the Observed Warming in Korea during the Recent Half Century (우리나라의 기온상승-도시효과인가 지구온난화인가)

  • 윤진일
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.4 no.1
    • /
    • pp.58-63
    • /
    • 2002
  • Since the rapid urbanization period coincides with the start of global warming, climate data might be contaminated with urbanization effect in Korea. Monthly normals of daily minimum, maximum, and mean temperature of 14 stations were calculated for 1951-1980 and 1971-2000 periods. Differences in two temperature normals were regressed to the natural logarithms of population increase at corresponding 14 cities from 1966 to 1990. The regression models were used to remove potential effects of urbanization from the apparent warming, and to determine the net contribution of global warming to the temperature change in Korea during the recent half century. According to the model calculation, there was little evidence of global warming in the warm season (May through November), while urbanization effect was common in all season except April. Up to 0.5$^{\circ}C$ warming of nighttime temperature was found to be induced by urbanization. Cool season temperature was increased by up to 0.6$^{\circ}C$ due mainly to the global warming of daytime temperature.

Use Situation Analysis of Evergreen Broad-Leaved Trees as Landscape Trees in Kyushu Area, Japan (일본 규슈지역에서의 조경수로서 상록활엽수의 이용실태 분석)

  • Park, Seok-Gon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.14 no.6
    • /
    • pp.29-39
    • /
    • 2011
  • This study aimed to select evergreen broad-leaved trees (EBT) that can be produced and planted in Korea by analyzing the current use of the trees for landscaping in the Kyushu area of Japan, a warm temperate region. The results revealed the total production of EBT was higher than that of conifers and due to the suitable growth environment of the area and the subsequent high demand for them. The landscape tree production methods in Japan were divided into container nursery and outdoor nursery, and the uses and species of the trees varied depending on the method; a variety of native species were produced in container nursery rather than in outdoor nursery, whereas trees used as ornamental, gardening, and shade plants were produced in outdoor nursery rather than in container nursery. The results also showed that in Fukuoka, a major city in Kyushu that is adjacent to Korea, the planting rate of EBT, used as ornamental, gardening, and shade plants, was higher than that of deciduous broad-leaved trees and conifers. In the city, the planting rate of Cinnamomum camphora was the highest, Elaeocarpus sylvestris var. ellipticus, Ternstroemia gymnanthera, Ilex rotunda, Quercus glauca, Camellia sasanqua, Eurya emarginata, Pittosporum tobira, Raphiolepis indica var. umbellata, Hedera rhombea, Kadsura japonica, Trachelospermum asiaticum var. asiaticum. These species were verified in Kyushu area for their application as landscape trees and are expected to serve as landscape trees in Korea if the planting areas of them are expanded by global warming, urban heat island and regional microclimate.

Comparison of Land Surface Temperature Algorithm Using Landsat-8 Data for South Korea

  • Choi, Sungwon;Lee, Kyeong-Sang;Seo, Minji;Seong, Noh-Hun;Jin, Donghyun;Jung, Daeseong;Sim, Suyoung;Jung, Im Gook;Han, Kyung-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.1
    • /
    • pp.153-160
    • /
    • 2021
  • Land Surface Temperature (LST) is the radiological surface temperature which observed by satellite. It is very important factor to estimate condition of the Earth such as Global warming and Heat island. For these reasons, many countries operate their own satellite to observe the Earth condition. South Korea has many landcovers such as forest, crop land, urban. Therefore, if we want to retrieve accurate LST, we would use high-resolution satellite data. In this study, we made LSTs with 4 LST retrieval algorithms which are used widely with Landsat-8 data which has 30 m spatial resolution. We retrieved LST using equations of Price, Becker et al. Prata, Coll et al. and they showed very similar spatial distribution. We validated 4 LSTs with Moderate resolution Imaging Spectroradiometer (MODIS) LST data to find the most suitable algorithm. As a result, every LST shows 2.160 ~ 3.387 K of RMSE. And LST by Prata algorithm show the lowest RMSE than others. With this validation result, we choose LST by Prata algorithm as the most suitable LST to South Korea.