• Title/Summary/Keyword: Urban groundwater

Search Result 215, Processing Time 0.031 seconds

Effects of Changes of Climate, Groundwater Withdrawal, and Landuse on Total Flow During Dry Period (기후, 지하수 취수 및 토지이용 변화의 건기 총유출량에 대한 영향)

  • Lee, Kil-Seong;Chung, Eun-Sung;Shin, Mun-Ju
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.11 s.172
    • /
    • pp.923-934
    • /
    • 2006
  • In this study, the effects of variability in climate, groundwater withdrawal, and landuse on dry-weather streamflows were investigated by input sensitivity analysis using SWAT (Soil and Water Assessment Tool). Since only dry-period precipitation and daily average solar radiation among climate variables have high correlation coefficients to total flow (TF), sensitivity analyses of those were conducted. Furthermore, an equation was derived from simulation results for 30 years by multiple regression analysis. It may be used to estimate effects of various climatic variations (precipitation during the dry period, precipitation during the previous wet period, solar radiation, and maximum temperature). If daily average maximum temperatures increase, TFs during the dry period will decrease. Sensitivities of groundwater withdrawal and landuse were also conducted. Similarly, groundwater withdrawals strongly affect streamflow during the dry period. However, landuse changes (increasing urbanization) within the forested watershed do not appear to significantly affect TF during the dry period. Finally, a combined equation was derived that describes the relationship between the total runoff during the dry period and the climate, groundwater withdrawal and urban area proportion. The proposed equation will be useful to predict the water availability during the dry period in the future since it is dependent upon changes of temperature, precipitation, solar radiation, urban area ratio, and groundwater withdrawal.

Hydrologic Cycle Simulation of Urban river for Rehabilitation of Water Environment (I) - Anyangcheon Basin - (물 환경 건전화를 위한 도시하천의 물 순환 모의 (I) - 안양천 유역 -)

  • Lee, Jung-Min;Lee, Sang-Ho;Lee, Kil-Seong
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.349-357
    • /
    • 2006
  • Nowadays, the discharges of urban streams during dry season are depleted because the hydrologic cycle in the watershed has been destroyed due to the expansion of the impermeable area, the excessive groundwater pumping, climate change, and so forth. The streamflow depletion may bring out severe water quality problems. This research are to investigate the hydrologic characteristics and to develop a technology to restore sound hydrologic cycle of Anyangcheon watershed. For the hydrological cycle analysis of the Anyangcheon watershed, continuous simulations of urban runoff were performed for the upstream basin of Gocheok bridge whose basin area covered 4/5 of the whole catchment area. The increase of impervious area by urbanization was analysed and its effect on urban runoff was evaluated. The SWMM 5 (Storm Water Management Model 5) was used for the continuous simulation of urban runoff. The analysis results of urbanization effect on runoff are as follows: the surface runoff in 2000 increases to 65% of the whole precipitation whereas the surface runoff in 1975 amounts to 50% of the precipitation; the groundwater runoff in 2000 amounts to 7% and shows 6% decrease during the period from 1975 to 2000.

Analysis on Permittivity of Soil to Evaluate Pore Water Contamination

  • Oh Myoung-Hak;Kim Yong-Sung;Yoo Dong-Ju;Park Jun-Boum
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.249-252
    • /
    • 2005
  • 저주파수에서 유전상수 측정시 100kHz 이하의 주파수 영역에서는 전극분극효과가 발생하므로 100kHz이상의 주파수에서 유전상수가 평가되어야 한다. 유전상수는 쌍극자모멘트의 수에 비례하기 때문에 흙의 유전상수는 체적함수비에 따른 선형적인 증가경향을 나타내었다. 용액에 이온성분이 존재하는 경우에는 수화작용에 의한 물분자의 배향분극 발현의 감소로 인하여 유전상수가 감소한다. 흙과 중금속 혼합시료의 경우 함수비가 큰 시료에서는 용액의 유전특성이 발현되지만, 함수비가 작은 경우에는 공간전하분극의 영향으로 유전상수가 10-20%정도 증가하는 경향을 나타내었다. 현장에서의 정확한 오염도 평가를 위해서는 토양의 함수비에 대한 평가가 반드시 수행되어야 한다.

  • PDF

An efficient 3D inversion of magnetotelluric data

  • Han, Nu-Ree;Choi, Ji-Hyang;Nam, Myung-Jin;Kim, Hee-Joon;Lee, Tae-Jong;Song, Yoon-Ho;Suh, Jung-Hee
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.261-266
    • /
    • 2007
  • An efficient three-dimensional (3D) inversion of magnetotelluric (MT) data can be carried out by using approximate sensitivities or avoiding the calculation of a full sensitivity matrix. In this paper, we propose approximate sensitivities for efficient 3D MT inversion based on the Gauss-Newton method and test and compare four kinds of sensitivities. Applying the four sensitivities to both synthetic and field data shows that the effects of sensitivities are highly dependent on data and thus applying various combinations of sensitivities is recommended for efficient inversion and good images.

  • PDF

EVALUATION OF GROUNDWATER-STREAM INTERACTION IN AN URBAN STREAM, CHEONGGYECHEON, KOREA

  • Hyun Yun-Jung;Kim Yoon-Young;Lee Kang-Kun
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.328-331
    • /
    • 2005
  • Cheonggyecheon, covered and Paved with concretes for about more than 50 years, is a losing stream crossing over the downtown of Seoul, Korea. Due to several environmental and economic Problems about the Cheonggyecheon area, the Cheonggyecheon restoration construction has started in 2003. In restoration of Cheonggyecheon, hydraulic barriers are to be installed so as to reduce stream depletion rates for maintaining the stream flow with supplying a certain amount of water. This study evaluates the groundwater-stream interaction by analyzing stream depletion rates of Cheonggyecheon. Results show that significant stream depletion occurs at the up-midstream where the Seoul subway lines are concentrated. Simulation results demonstrate that both horizontal and vertical hydraulic barriers impeding groundwater flow into subway lines are more efficient than a horizontal barrier only for stream depletion rate reduction.

  • PDF

Rainwater Infiltration Characteristics in the Unsaturated Soil : Comparison of Finite Element Model with Experimental Results (불포화 토양에서 빗물의 침투특성 : 유한요소 모델과 실험결과 비교)

  • Yoo, Kun-Sun;Kim, Sang-Rae;Kim, Tschung-Il;Yoon, Hyun-Sik;Han, Moo-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.6
    • /
    • pp.27-33
    • /
    • 2011
  • Infiltration plays an important role in the urban water cycle. Infiltration has a potential to contribute to groundwater recharge in addition to runoff reduction. However, infiltration in urban areas has been considered only as a means of runoff reduction. Conventional design methods for infiltration facilities assume soils to be fully-saturated for the sake of simplicity. The amount of groundwater recharge can not be estimated properly with this scheme. Hence, the characteristics of the unsaturated soil condition need to be considered. The finite element model using SEEP/W to estimate infiltration under the unsaturated condition is presented. Infiltration tests for Joomonjin sand are performed and the infiltration behavior of Joomoonjin sand under the unsaturated condition is measured experimentally to verify the validity of the finite element model. The results from comparing infiltrated volume between the saturated and the unsaturated conditions under the same soil and rainfall conditions show that the infiltrated volume in the unsaturated condition is two times bigger than that in the saturated condition.

Groundwater-use Estimation Method Based on Field Monitoring Data in South Korea (실측 자료에 기반한 우리나라 지하수의 용도별 이용량 추정 방법)

  • Kim, Ji-Wook;Jun, Hyung-Pil;Lee, Chan-Jin;Kim, Nam-Ju;Kim, Gyoo-Bum
    • The Journal of Engineering Geology
    • /
    • v.23 no.4
    • /
    • pp.467-476
    • /
    • 2013
  • With increasing interest in environmental issues and the quality of surface water becoming inadequate for water supply, the Korean government has launched a groundwater development policy to satisfy the demand for clean water. To drive this policy effectively, it is essential to guarantee the accuracy of sustainable groundwater yield and groundwater use amount. In this study, groundwater use was monitored over several years at various locations in Korea (32 cities/counties in 5 provinces) to obtain accurate groundwater use data. Statistical analysis of the results was performed as a method for estimating rational groundwater use. For the case of groundwater use for living purposes, we classified the cities/counties into three regional types (urban, rural, and urban-rural complex) and divided the groundwater facilities into five types (domestic use, apartment housing, small-scale water supply, schools, and businesses) according to use. For the case of agricultural use, we defined three regional types based on rainfall intensity (average rainfall, below-average rainfall, and above-average rainfall) and the facilities into six types (rice farming, dry-field farming, floriculture, livestock-cows, livestock-pigs, and livestock-chickens). Finally, we developed groundwater-use estimation equations for each region and use type, using cluster analysis and regression model analysis of the monitoring data. The results will enhance the reliability of national groundwater statistics.

Heavy Metal Contamination of Roadside Gully-Pot Sediments, Seoul, Korea

  • Kim, Sung-Hwan;Lee, Pyeong-Koo;Yun, Seong-Taek;So, Chil-Sup
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.222-225
    • /
    • 2001
  • In urban environments, the surface land impermeability fundamentally related to urban growth emphasizes the environmental problems such as the storm water peak flow (so-called the urban flooding) and the pollution. The conventional urban drainage system provides a number of temporary reservoirs intercepting and retaining surface-derived pollutants following their introduction to and deposition upon the impermeable surface. Gully-pots are common features in urban drainage systems in Korea, which were installed for draining rainwater to prevent regurgitation in rainy season and retaining larger particles, hence minimizing pipe blockage problems. When the road runoff conveying sediment enters a gully-pot, the sediment mixes with the gully liquor causing direct pollution of receiving waters. The characteristics of local sediment contamination are usually related to the types of land use activities that take place or have taken place within the area., This study was undertaken to evaluate the spatial and temporal variations of the contamination of gully-pot sediments in Seoul with respect to heavy metals such as As, Cd, Co, Cr, Ni, Pb, Cu and Zn. The heavy metal data were examined according to the land use type. In this paper, sampling sites in Seoul were divided into six groups (commercial area, industrial area, residental area, motor way, rural area, and local pollution).

  • PDF

Assessing Groundwater Vulnerability Using DRASTIC Method and Groundwater Quality in Changwon City (DRASTIC과 지하수 수질에 의한 창원시 지하수 오염취약성 평가)

  • Hamm Se-Yeong;Cheong Jae-Yeol;Kim Moo-Jin;Kim In-Soo;Hwang Han-Seok
    • Economic and Environmental Geology
    • /
    • v.37 no.6 s.169
    • /
    • pp.631-645
    • /
    • 2004
  • This study assesses groundwater vulnerability to contaminants in industrial and residential/commercial areas of the city of Changwon, using DRASTIC technique and groundwater data. The DRASTIC technique was originally applied to situations in which the contamination sources are at the ground surface, and the contaminants flow into the groundwater with infiltration of rainfall. Mostly the industrial area has higher DRASTIC indices than the residential/commercial area. However, a part of the residential/commercial area having much groundwater production and great drawdown is more contaminated in groundwater than other industrial and the residential/commercial areas even if it has lowest DRASTIC indices in the study area. It indicates that groundwater contamination in urban areas can be closely related to excessive pumping resulting in a lowering of the water level. The correlation coefficient between minimum DRASTIC indices and the degree of poor water quality for 10 districts is as low as 0.40. On the other hand, the correlation coefficients between minimum DRASTIC indices and the groundwater discharge rate, and between minimum DRASTIC indices and well distribution density per unit area are 0.70 and 0.87, respectively. Thus, to evaluate the potential of groundwater contamination in urban areas, it is necessary to consider other human-made factors such as groundwater withdrawal rate and well distribution density per unit area as well as the existing seven DRASTIC factors.

Track Stability Assessment for Deep Excavations in Adjacent to Urban Railways (도시철도 인접지반 깊은 굴착 시 궤도 안정성 평가)

  • Jeon, Sang-Soo;Lee, Sang-Seung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.614-627
    • /
    • 2018
  • Urban railway lines have been constructed adjacent to residential buildings and urban areas. The expansion of transportation networks and reconstruction of residential buildings in highly populated urban areas require deep excavations in areas adjacent to urban railways. Mobilized soil stresses and changes in the groundwater level induced by deep excavations results in track irregularities in urban railways. In this study, a three-dimensional finite difference model using the commercial program FLAC3D was adopted to estimate the horizontal displacements of earth retaining structures, settlements of backfill, the stability of track irregularity and underground box structure based on the criteria of each railway organization and its relationships. In deep excavations, a change in groundwater level induces relatively very small differences for track gauge irregularities, whereas relatively large differences for longitudinal irregularities of 72.5%, twist irregularities of 83.3%, cross level irregularities of 61.9%, and alignments of 43.3% were found to be the maximum differences when the horizontal displacement of earth retaining wall and settlement of backfill were 65.1% and 21.4%, respectively, because the groundwater level (GWL) on the ground surface-mobilized tensile strength of the underground box structure exceeds the allowable value. Therefore, three-dimensional numerical analysis was performed in this study. Overall, real-time monitoring should be carried out to prevent railway accidents in advance when a deep excavation adjacent to urban railway structures is constructed.