• 제목/요약/키워드: Urban Sewage

검색결과 198건 처리시간 0.03초

대규모 아파트 단지주변 하수관로의 악취 발생과 대책 1: 주거지역 하수관로의 악취 발생 특성 (The Foul Smelling from Sewer Pipe near Large Apartment Complexes and its Countermeasures I: Characteristics of the Foul-Smelling Sewer Pipe in Residential Areas)

  • 이장훈;강선홍
    • 상하수도학회지
    • /
    • 제21권5호
    • /
    • pp.621-629
    • /
    • 2007
  • This study intends to investigate the characteristics of the foul smell of sewer pipes near large apartment complexes as complaints about offensive odors have drastically increased in urban residential areas. Targeting apartments where people actually complained about foul orders, the study result revealed that components in the smell of the water-purifier tank of the target apartment were very similar to those of sewage treatment plants and night soil treatment plants. Measuring components of odors inside the management layer of tank showed that the concentration of hydrogen sulfide was 10ppm, which is approximately 160 times the safety standard of 0.06ppm; the concentration of mercaptan was 0.9ppm, which is about 220 times the safety standard of 0.004ppm. The source materials of foul odors were discharged outside through ducts, and those households living near outlets producing bad smell complain that it gets worse depending on the air pressure or wind direction and strength, and they could not even open windows. As well, these source materials were transferred by discharge pumps to public sewer pipes outside the apartment complex. While discharge pumps starts operating, they remain on the sewer pipe and then begin to spread over to roads through small openings of manholes on the road. Then, the smell offends passers-by and residents near the road, leading to a lot of complaints. The study results suggest that, among the sources of foul odors in sewer pipes of residential areas, especially those from the water-purifier tank of large apartments, hydrogen sulfide should be the main target for follow-up treatment.

코안다효과가 적용된 빗물받이에 관한 연구 (A Study on Rain Gutters with Coanda Effect)

  • 정용신;김용선;신희재;고상철
    • 한국기계가공학회지
    • /
    • 제19권4호
    • /
    • pp.58-64
    • /
    • 2020
  • Large-scale flooding due to extreme weather and typhoons causes heavy damage. This is especially true in urban areas where accumulated debris prevents the smooth drainage of rainwater in sewage facilities such as rain gutters installed near roads. In this study, to improve the drainage performance and effectively remove foreign substances by applying the dust screen used in rivers, the rain gutter with Coanda effect was simulated and compared with the experiment. The simulation was performed by setting the parameters to the fillet radius R1 and R2 at the top of the screen filter, the fillet radius R3 at the bottom of the screen filter, and the height H of the gap W from the bottom. W is the gap at the backside of screen filter which is applied to stimulate the Coanda effect. According to the simulation results, the highest drain performance was 87.99% derived from R1= 30mm, R2= 5mm, R3= 85mm, H= 75mm, and W= 2mm. The error rate of simulation results refer to the 4.89%~7.36% compared to the experimental results. In the future, by considering the slope according to the installation environment, the simulation results can be applied to the actual roadside to help prevent flood damage.

중온 혐기성 연속회분식 공정에 의한 도시하수슬러지의 소화가능성 평가 (Application of Anaerobic Sequencing Batch Reactor to Mesophilic Digestion of Municipal Sewage Sludge)

  • 허준무;장덕;정태학;손부순;박종안
    • 한국환경보건학회지
    • /
    • 제24권2호
    • /
    • pp.9-19
    • /
    • 1998
  • Laboratory experiments were carried out to investigate the performance of anaerobic sequencing batch reactor(ASBR) for digestion of a municipal sludge. Each cycle of the ASBR comprised feeding, two-or three-day reaction, one-day thickening, and withdrawal. The reactors were operated at an HRT of 10days and 5days with an equivalent organic loading rate of 0.8-1.54 gVS/l/d, 1.81-3.56 gVS/l/d at 35$\circ$C, respectively. Solids accumulation was remarkable in the ASBR during start-up period, and directly affected by settleable solids in the feed sludge. Floatation thickening occured in the ASBRs, and Solids profiles at the end of thickening step dramatically changed at solid-liquid interface. Slight difference in solids concentrations was observed within thickened sludge bed. Efficiencies through floatation thickening were comparable to that of additional thickening of the completely mixed control reactor. Average solids concentrations in the ASBRs were 2.2-2.6 times higher than that in the control throughout the total operation period. The dehydrogenase activity had a strong correlation with the solids concentration. Organics removals based on clarified effluent of the ASBRs were consistently above 86%. Remarkable increase in equivalent gas production of 27-52% was observed at the ASBRs compared with the control though the control and ASBRs showed similiar effluent quality. Thus, digestion of a municipal sludge was possible using the ASBR in spite of high concentration of solids in the sludge.

  • PDF

주거복지지표 개발에 관한 연구 I - 객관적 측면의 주거복지 지표를 중심으로 - (A Study on Development of the Objective Indicators of Housing Welfare)

  • 홍형옥;채혜원;최은희
    • 한국주거학회논문집
    • /
    • 제19권5호
    • /
    • pp.77-84
    • /
    • 2008
  • The purpose of this study is to develop the housing welfare indicators for evaluating housing welfare policies conducted by the Korean government. The contents of this research were as follows: as a phrase of setting up the development of housing welfare indicators, the scope of housing welfare and the direction of developing housing welfare indicators were settled. Second, as a phrase of drawing the housing welfare indicators, the indicators were categorized and selected. Third, as a phrase of applying the housing welfare indicators, the indicators in this research were quantified, and suggest the housing welfare from 2000 to 2005. As a result of this research, selected housing welfare indicators were settled as follows: the housing welfare indicators comprise 9 in the department of 'House', 4 in the department of 'Community', and 6 in the department of 'Policy Environment' (19 in total). Indicators were (1) Ratio of housing with Flush Toilets (2) Ratio of housing with Kitchen Sink (3) Ratio of housing with Bath facilities (4) Ratio of housing provided water supply (5) Ratio of housing supplied a sewage system (6) Floor Space per person (7) Number of persons per Room (8) PIR (9) RIR (10) Community Facilities Space per person (11) Urban Park Space per person (12) Journey to work (13) Crime Ratio (14) Number of Houses per 1,000 persons (15) Ratio of Substandard housing of the Minimum Housing Standard (16) Ratio of Irregular Dwelling Households (17) Ratio of Owner Occupant (18) Ratio of compulsory immigration (19) Ratio of Long-term Public Social Houses. The housing welfare indicators developed in this research will be used for the comprehensive assessment of the results of housing welfare policies and the establishment of housing policies as a basic material in the future.

A Survey of Cryptosporidium Oocysts in Water Supplies during a 10-Year Period (2000-2009) in Seoul

  • Lee, Mok-Young;Cho, Eun-Joo;Lee, Jin-Hyo;Han, Sun-Hee;Park, Yong-Sang
    • Parasites, Hosts and Diseases
    • /
    • 제48권3호
    • /
    • pp.219-224
    • /
    • 2010
  • This study has been conducted to estimate the occurrence of Cryptosporidium oocysts in water supplies in the Metropolitan area of Seoul, South Korea, for 10 years from 2000 to 2009. Water samples were collected quarterly at 6 intakes in the Han River and its largest stream and 6 conventional Water Treatment Plants (WTPs) serving drinking water for 10 million people of Seoul. Cryptosporidium oocysts were found in 22.5% of intake water samples and arithmetic mean was 0.65 oocysts/10 L (range 0-22 oocysts/10 L). Although the annual mean of oocyst number was as low as 0.04-1.90 oocysts/10 L, 3 peaks in 2004 and 2007 were observed and the pollution level was a little higher in winter. The lowest density was observed at Paldang intake and the pollution level increased at Kuui and Jayang intakes. At the end of the largest stream, oocysts were found in 70% of collected samples (mean 5.71 oocysts/10 L) and it seemed that its joining the Han River resulted in the increase at Kuui intake and downstream. Oocyst removal by physical process exceeded 2.0-2.3 log and then all finished water samples collected at 6 WTPs were negative for Cryptosporidium in each 100 L sample for 10 years. These results suggested that domestic wastewater from the urban region could be a source of Cryptosporidium pollution and separating sewage systems adjacent to the intakes could be meaningful for some intakes having weakness related to parasitological water quality.

생물막 여과반응기를 이용한 고도질소 제거법의 개발 (Development of Biological Filtration Process for Effective Nitrogen Removal in Tertiary Treatment of Sewage)

  • 정진우;김성원;津野洋
    • 한국물환경학회지
    • /
    • 제22권2호
    • /
    • pp.222-229
    • /
    • 2006
  • The treatment performance and operational parameters of a tertiary wastewater treatment process a biological filtration system were investigated. The biological filtration system consisted of a nitrification filter (Fiter 1) and a polishing filter with anoxic and aerobic parts (Filter 2). SS, T-C-BOD, and T-N in effluent were kept stable at less than 3, 5 mg/L, and 5 mgN/L, respectively, under a HRT in Filter (filter-bed) of 0.37~2.3 h. T-N at the outlet of Filter 2 were about 1~5 mgN/L under the condition of LV of 50~202 m/d. In Filter 2, denitrification was accomplished under LV of 50~168 m/d in a 1 m filter-bed. However, the denitrification capacity reached the maximum when the linear velocity was increased to 202 m/d. Relationship between increase in microorganism and headloss was clearer in Filter 2. As a result, the denitrification rate increased from 1.0~2.3 kgN/($m^3-filter-bed{\cdot}d$) as the headloss increased. The COD removal rate was 6.0~9.6 kgCOD/($m^3-filter-bed{\cdot}d$) when operated with Filters 1 and 2. These results mean that captured bacteria contributed a part of COD consumption and denitrification. The maximum nitrification and denitrification rate was 0.5 and 4 kgN/($m^3-filter-bed{\cdot}d$) in Filter 1 and 2.The ratio of backwashing water to the treated water was about 5~10 %. In Filter 1, wasted sludge in backwashing was only 0.7~5.3 gSS/($m^3$-treated water). In Filter 2, added methanol was converted into sludge and its value was 8.0~24 gSS/($m^3$-treated water). These results proved that this process is both convenient to install as tertiary treatment and cost effective to build and operate.

More about Taxonomic Sufficiency: A Case Study using Polychaete Communities in a Subtropical Bay Moderately Affected by Urban Sewage

  • Muniz Pablo;Pires-Vanin Ana M. S.
    • Ocean Science Journal
    • /
    • 제40권3호
    • /
    • pp.127-143
    • /
    • 2005
  • The taxonomic sufficiency approach has been proposed as a surrogate for the typical analysis of species-abundance data, especially in conditions involving prominent pollution gradients. Here, we evaluate the use of taxonomic sufficiency with infralittoral macrobenthic data derived from samples taken in a moderate polluted subtropical environment in southeastern Brazil, analysing five taxonomic levels and including two functional levels throughout polychaete feeding guilds and trophic groups. The data were collected seasonally at nine stations and studied for two abundance data series (0.5 and 1.0 mm sieve mesh-size). The results showed a similar ordination pattern between the two sieve mesh-size, but with the 0.5 mm sieve data a different pattern was observed during austral summer. A slight loss of information was detected using genus, family, polychaete species and their feeding guilds as taxonomic/functional units. These results together with those of the cost! benefit ratio, suggested that the family level seemed to be sufficient to detect the impact caused by moderate pollution in this shallow-water, subtropical environment. In additional, through the use of feeding guilds, similar patterns are obtained. Correlation analysis showed that chlorophyll a, total organic matter, zinc, and chromium sediment content were the variables that best explained the biological pattern observed and not always the best correlation coefficient occurring at the species level. The feeding guild approach seems to be useful and generates interpretable results similar to those obtained with the species level of the whole macroinfauna. The results showed an important cost reduction in the sample processing, suggesting that it is possible to adopt a coarser taxonomic level monitoring program even in species-rich communities.

하수터널의 콘크리트 라이닝 부식 방지공법 선정방법에 관한 고찰 (Selection of concrete lining corrosion protection method for large sewer tunnels)

  • 문준식;이성준
    • 한국터널지하공간학회 논문집
    • /
    • 제16권4호
    • /
    • pp.347-360
    • /
    • 2014
  • 최근 기후변화로 인한 도시침수와 합류식 하수관거 월류수 (combined sewer overflow)로부터 처리되지 않은 하수의 하천유입, 그리고 그에 따른 하천의 오염의 방지를 위해 지하방수로/저류조 겸용의 대형 하수터널의 건설이 증가하고 있다. 이러한 대형 하수터널의 경우 대부분 콘크리트 라이닝을 적용하고 있지만 하수관거 내에서 발생되는 황화수소($H_2S$)로 인하여 콘크리트가 부식될 수 있으므로 이에 대한 적절한 보호공이 필요하다. 본 논문에서는 최소 100년의 수명을 고려하여 설계된 대형 하수터널의 콘크리트라이닝 부식을 방지하기 위해 여러 공법들을 소개하고 각 공법의 일반적인 장단점과 설계 사례를 설명하였다. 하지만 대형 하수터널 라이닝의 부식방지 공법들의 적용 실적이 부족하여 부식방지 공법을 적용한 터널설계 대안에 대한 객관적인 평가가 쉽지 않다. 따라서 본 논문은 설계 사례연구를 통해 콘크리트 라이닝 부식방지 공법선정 프로세스를 소개하였다.

광촉매 이산화티타늄(TiO2)을 혼합한 도로 포장재의 습윤 조건에서의 성능 변화에 관한 실험적 연구 (Experimental Study on Capacity Variation of Paving Materials with TiO2 in Wet Condition)

  • 서다와;윤태섭
    • 한국지반공학회논문집
    • /
    • 제32권5호
    • /
    • pp.49-55
    • /
    • 2016
  • 본 연구는 도심지의 도로 환경을 고려하여, 기능성 포장 재료 중 하나인 이산화티타늄($TiO_2$)을 포함한 시멘트 모르타르의 실질적인 일산화질소(NO) 제거 성능을 평가하고자 하였다. 실험은 크게 두 가지로, 유입되는 기체의 습도에 따른 NO 제거율 변화 실험과 시편의 포화도에 따른 NO 제거율 변화 실험으로 구성되었다. 습도 변화 실험에서는 건조 상태의 시편을 대상으로 유입 기체의 습도를 변화시키며 NO 제거율을 관찰하였다. 습도-NO 제거율 곡선은 로그 정규 분포 형상으로, 특정 습도에서 최대 NO 제거율이 나타났다. 포화도 변화 실험은 강우 및 생활 하수로 인하여 불포화 상태인 도로를 반영하고자 습윤 상태인 시편을 대상으로 하였다. 습윤 상태의 시편은 건조 상태보다 낮은 NO 제거 성능을 보였으며 증발이 진행되면서 $TiO_2$가 노출되어 NO 제거 성능이 증가하였다. 그리고 시편의 특정 깊이 아래에 존재하는 $TiO_2$는 NO 제거 성능에 크게 기여하지 않는 것으로 나타났다.

저부하형 개발을 위한 화단형 빗물침투시설 적용방안 - 생태전원마을에서의 적용을 중심으로 - (Application of the Flowerbed Type Infiltration System for Low Impact Development - Focus on the Application to Eco-Village -)

  • 한영해;이태구
    • KIEAE Journal
    • /
    • 제12권3호
    • /
    • pp.33-40
    • /
    • 2012
  • Since 2000 country region developmental policy has been to integrate not only the improvement of physical living environment but also various subjects on ecology, environment, scenery, local culture, and green tourism. This study has recently established a decentralized Rainwater Management plan in order to provide an hydrology cycle system to the eco-village being planned by Seocheon-gun as a part of the garden village development business promoted by the ministry of agriculture and forestry. Hydraulic conductivity of the subject area is measured at $10^{-7}{\sim}10^{-10}m/sec$, and a flowerbed-type rainwater Infiltration system capable of controlling a non-point pollution source that stems from the development-caused impermeable surface has been applied. In the case of rainwater flowing out from the main entrance way and parking lot within the complex being treated in the flowerbed-type rainwater infiltration system, natural purification effects via soil and plants as well as natural water cycling effects through evaportranspiration and infiltration are expected. The significance of this study, compared to conventional decentralized rainwater management being applied limited to the urban areas, is that it offers appropriate rainwater management planning based on the analysis of the current situation of the subject area. Decentralized Rainwater Management is a valuable measure both economically and ecologically that reduces the burdens on local underground water cultivation as well as rain water pipe lines or purification systems, and sewage pipes.