• 제목/요약/키워드: Urban Lighting

검색결과 104건 처리시간 0.026초

쉴드 TBM터널 상부 지반 연약대 전기탐사 (Electrical Resistivity Imaging for Upper Layer of Shield TBM Tunnel Ceiling)

  • 정현기;박철환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.401-408
    • /
    • 2005
  • Recently shield TBM tunnellings are being applied to subway construction in Korean cities. Generally these kinds of tunnellings have the problems in the stability of ground such as subsidence because urban subway is constructed in the shallow depth. A sinkhole occurred on the road just above the tunnel during tunneling in Kwangju, so a survey for upper layer of the tunnel was needed. But conventional Ground Probing Radar can't be applicable due to the presence of steel-mesh screen in the shield segment, so no existent geophysical method is applicable in this site. Because the outer surface of each shield segment is electrically insulated, dipole-dipole resistivity method which is popular in engineering site investigation, was tried to this survey for the first time. Specially manufactured flexible ring-type electrodes were installed into the grouting holes at an interval of 2.4 m on the ceiling. The K-Ohm II system which has been developed by KIGAM and tested successfully in many sites, was used in this site. The system consists of 1000Volt-1Ampere constant-current transmitter, optically isolated 24 bit sigma-delta A/D conversion receiver - maximum 12 channel simultaneous measurements, and graphical automatic acquisition software for easy data quality check in real time. Borehole camera logging with circular white LED lighting was also done to investigate the state of the layer. Measured resistivity data lack of some stations due to failing opening lids of holes, shows general high-low trend well. The dipole-dipole resistivity inversion results discriminate (1) one approximately 4 meter diameter cavity (grouted but incompletely hardened, so low resistivity - less than $30{\Omega}m$), (2) weak zone (100-200${\Omega}m$), and (3) hard zone (high resistivity - more than 1000${\Omega}m$) very well for the distance of 320 meters. The 2-D inversion neglects slight absolute 3-D effect, but we can get satisfactory and useful information. Acquired resistivity section and video tapes by borehole camera logging will be reserved and reused if some problem occurs in this site in the future.

  • PDF

제주지역 미세먼지의 장기변동 및 농도변화에 관한 국지기상 분석 (An Analysis of Long-Term Variation of PM10 Levels and Local Meteorology in Relation to Their Concentration Changes in Jeju)

  • 박연희;송상근;이수정;김석우;한승범
    • 한국환경과학회지
    • /
    • 제25권1호
    • /
    • pp.107-125
    • /
    • 2016
  • Long-term variations of $PM_{10}$ and the characteristics of local meteorology related to its concentration changes were analyzed at 4 air quality sites (Ido-dong, Yeon-dong, Donghong-dong, and Gosan) in Jeju during two different periods, such as PI (2001-2006) and PII (2007-2013), over a 13-year period. Overall, the long-term trend of $PM_{10}$ was very slightly downward during the whole study period, while the high $PM_{10}$ concentrations in PII were observed more frequently than those in PI. The concentration variations of $PM_{10}$ during the study period was clarified in correlation between $PM_{10}$ and meteorological variables, e.g. the low (high) $PM_{10}$ concentration with large (small) precipitation or high (low) radiation and in part high $PM_{10}$ concentrations (especially, Donghong-dong and Gosan) with strong wind speed and the westerly/northwesterly winds. This was likely to be caused by the transport effect (from the polluted regions of China) rather than the contribution of local emission sources. The $PM_{10}$ concentrations in "Asian dust" and "Haze" weather types were higher, whereas those in "Precipitation", "Fog", and "Thunder and Lighting" weather types were lower. The contribution of long-range transport to the observed $PM_{10}$ levels in the urban center (Ido-dong, Yeon-dong, and Donghong-dong), if estimated by comparison to the data of the background site (Gosan), was found to explain about 80% (on average) of its input.

아파트 구조물 설치에 따른 교육환경 일조량 분석 (Analysis of Sunshine Amount for Education Environment according to Installation of Apartment Structures)

  • 장호식
    • 한국측량학회지
    • /
    • 제30권2호
    • /
    • pp.117-124
    • /
    • 2012
  • 최근에 노후화된 도시정비사업으로 토지의 집약적 이용을 위해 아파트 및 공동주택을 초고층 및 고층 아파트 구조물로 재건축 승인함에 따라 인근 주거지역의 일조권 침해에 따른 사회문제로 대두되고 있다. 특히, 교육시설에 있어서의 일조량 침해에 따른 교육환경 여건은 많은 문제점을 내포하고 있다. 따라서, 본 연구에서는 이러한 교육환경 일조량 분석을 위해 Auto $CAD^{(R)}$ 프로그램을 이용하여 교육시설물에 대하여 3차원 모델링으로 구성하였다. 그리고, 시뮬레이션 기법으로 교육시설에 있어서 창과 운동장을 채광기준면으로 설정하여 태양의 움직임에 따른 진태양시의 일조량을 아침 8:00에서 오후 4:00까지1분 단위로 계산하였다. 또한, 아파트 신축공사 전 후의 피해에 따른 교육시설의 일조환경을 수치화하였고 일영투사법에 의해 제작된 영상과 비교하여 교육환경 일조량을 검증할 수 있었다. 향후 이러한 시뮬레이션 기법을 활용하여 교육환경일조량 분석에 효율적으로 사용될 수 있을 것으로 기대된다.

GIS Application for Site Planning

  • Han, Seung-Hee;Lee, Jin-Duk
    • 대한공간정보학회지
    • /
    • 제17권1호
    • /
    • pp.53-59
    • /
    • 2009
  • 일반도시계획은 보편적이고 획일적인 건축행위를 제한하는 평면계획인 반면 지구단위계획은 필지, 가구, 획지단위 별로 차등을 두어 다양한 건축행위를 유도할 수 있는 입체적인 계획이다. 그러므로 단지계획을 위해서는 토지이용계획 등 2차원적인 토지정보뿐만 아니라 채광, 배수, 향 등의 분석을 위해 3차원적인 지형정보의 이용이 필요하다. 이러한 필요성을 충족시키기 위해 GIS 및 사진측량 기법을 이용하여 정보를 구축한다면 보다 합리적이고 효율적으로 단지계획을 수립할 수 있다. 본 연구에서는 테스트지역에 대해 GIS기법을 이용하여 단지계획을 위한 정보를 구축하였으며 위성영상과 DEM으로 대상지역의 3차원 모델을 구축하여 분석하였다. 연구결과 토지이용분석, 배향 분석, 수계분석, 경사분석을 실시하여 지구단위계획 수립에 효율적으로 활용할 수 있었다. 또한 분석결과를 반영하여 실제 대상지역에 대해 지구단위계획을 수립한 결과 적절하며 효율적임을 알 수 있었다.

  • PDF

초등학교 및 중학교의 일체형 셔터 안전성 확보 방안 (Methods of Ensuring Safety for Integrated Fire Protection Shutters at Elementary and Middle Schools)

  • 윤해권
    • 한국화재소방학회논문지
    • /
    • 제30권5호
    • /
    • pp.36-45
    • /
    • 2016
  • 일체형 방화셔터는 피난과는 무관하게 무분별하게 설치되고 있다. 학교 건축물의 복도, 통로, 계단 등에 주로 적용하고 있어 학생들이 사고의 위험에 언제나 노출된 상태이다. 따라서 부천옥길과 화성동탄에 있는 초등학교와 중학교에 설치된 방화셔터의 설치현황과 방화셔터 관련 사고사례를 조사하여 일체형 셔터의 출입구 및 피난, 시공관리, 유지관리의 문제점을 파악하였다. 피난자가 출입구 위치를 쉽게 확인할 수 있도록 바닥에 통로유도등 또는 표지를 설치하고, 방화셔터에 장애물 감지장치를 설치하여 셔터에 깔리는 인명피해를 줄이도록 하였고, 방화셔터의 성능시험 확대, 방화셔터의 성능을 유지하기 위해 주 또는 월 1회 정도 성능시운전을 시행, 스프링클러설비는 $1000m^2$를 넘는 4층 이상에만 설치할 것이 아니라 학교용도는 규모에 관계없이 전 층에 반영하여 방화셔터 설치개소를 최소화하는 방안을 제안하고자 한다.

아로요 파크웨이 조경설계 (Streetscape Design of Arroyo Parkway, Pasadena, California)

  • 정욱주
    • 한국조경학회지
    • /
    • 제32권4호
    • /
    • pp.105-117
    • /
    • 2004
  • The Pasadena Freeway follows the Arroyo Seco through foothills and scenic passes to link Downtown Los Angeles with Pasadena. The approximately 10 mile road was the first freeway built in the West during the 1930's and is today designated as a Historic Parkway. As it approaches Pasadena, it terminates at a traffic light intersection at Glenarm Street, and then becomes a commercial road the Arroyo Parkway. This one and a quarter mile long, north south road moves significant volumes of traffic both into and out of Pasadena. The Arroyo Parkway is thus a major 'gateway' and an important axis of orientation and movement, terminating in the City's core civic, commercial and retail district. Planting, lighting, signage, paving, furnishing and fixtures ought to all be properly designed and coordinated to create a distinctive 'gateway' experience arriving to Pasadena and driving along the Arroyo Parkway. Alternate design studies, developed in discussion with City officials and others involved in the redevelopment of the area, would need to be done to properly decide on the best direction. Issues of heritage and traditional streetscape will likely have to be reconciled with both the reality of the vehicular character of the road and more contemporary themes. Obviously with such large parcels of property available in the Arroyo Fair Oaks corridor, there is a huge potential for redevelopment and building. This potential would only be strengthened by the Light Rail Line and its stations, the improvements to the Arroyo Parkway, and the redevelopment of the Arts Center College of Design. Guides and controls to the development process, including programming and physical design studies, would need to be developed in order to ensure that the maximum potential for the corridor be realized. This concept proposal suggests that the whole strip might be developed as a Arts and Technology corridor, with special emphases on education, public culture, media and lifestyle. The full programming possibilities need to be further developed. Additionally, appropriate urban design guidelines to ensure high quality development also need to be incorporated into an overall development plan.

반투과형 태양전지를 이용한 창호형 BIPV 건물의 환경성능 분석 (Comparison assessment of semi-transparent solar cell for BIPV windows)

  • 정민희
    • 토지주택연구
    • /
    • 제11권1호
    • /
    • pp.87-94
    • /
    • 2020
  • To implement the planning of zero-energy buildings, their energy performance must be improved, and renewable energy applications must also be included. To accelerate the use of renewable energies in such buildings, BIPVs should be actively used in windows and on roofs. Window-type BIPVs are being developed in various forms depending on the size, composition, area ratio of the window, specification of glass, and so on. To analyze the applicability of various solar cells as window-type BIPVs, in this study, we evaluated their applicability, at the current development level, by analyzing the indoor illuminance, heat gain and heat loss; the cooling, heating, and lighting energy levels; and the generation performance of the various solar cells. To enhance the future applicability of window type BIPV, we analyze the overall energy performance of the building, according to changes in visible light transmittance and generation efficiency. The main research results are as follows. The area ratios above the standard illuminance, based on the window type and according to the VLT, were in order of low-e glazing, a-Si window, DSSC window, and c-Si window. The heat gain of the semi-transparent solar cell winodw was remarkably low. The energy consumption of buildings was highest in the order of c-Si window, DSSC window, a-Si window, and clear low-e window. However, in the case of including the power generation performance of the solar cell, the energy consumption was found to be high in order of DSSC window, c-Si window, a-Si window, and clear low-e window. In the future, if a window-type BIPV is developed, we believe that improvement in power generation performance and improvement in visible light transmittance will be needed.

표본건물 계측에 의한 공동주택 세대에서의 용도별 에너지사용량 및 CO2 배출량 연간 원단위 (2016 - 2017) 분석 (Annual Intensities (2016-2017) Analysis of Energy Use and CO2 Emission by End Use based on Measurements of Sample Apartment Units)

  • 진혜선;임한영;이수진;김성임;임재한;송승영
    • 대한건축학회논문집:구조계
    • /
    • 제34권7호
    • /
    • pp.43-52
    • /
    • 2018
  • In this study, annual site and primary energy use intensities (EUIs) and CO2 emission intensities (CEIs) per area by end use were estimated based on the measurement data from June 2016 to May 2017 of 50 sample apartment units in Seoul. In addition, estimated site EUIs by end use were compared to the U.S. Residential Energy Consumption Survey (RECS) 2009 data. Site EUIs by end use were found to be in the order of heating > electric appliance > domestic hot water > cooking > lighting > cooling > air movement. In the case of primary EUIs and CEIs by end use, electric appliance was found to be the largest. As results of comparison with the RECS 2009 data, it was found that site EUIs were very similar for heating, domestic hot water and electric appliance, etc., but slightly different for cooling. The number of sample apartment units will continue to increase until 2020 (total number of samples 200) and intensities data by end use will be continuously updated through continuous collection of measurement data.

자연광의 색온도 주기 재현을 위한 슬라이딩 윈도우 기반 이상치 판정 알고리즘 (Algorithm for Judging Anomalies Using Sliding Window to Reproduce the Color Temperature Cycle of Natural Light)

  • 전건우;오승택;임재현
    • 한국멀티미디어학회논문지
    • /
    • 제24권1호
    • /
    • pp.30-39
    • /
    • 2021
  • Research in the field of health lighting has continued to advance to reproduce the color temperature of natural light which periodically changes. However, most of this research could only reproduce a uniform circadian color temperature of natural light, therefore failing to realize the characteristics of the circadian cycle of color temperature difference by latitude and longitude. To reproduce the color temperature of natural light on which the characteristics of a region are reflected, the collection technology of real-time characteristics of natural light is needed. If the color temperatures which are not within a periodical pattern due to climate changes, etc., are measured, it will be difficult to judge the occurrence (presence) of the anomalies and to reproduce the circadian cycle of the color temperature of natural light. Therefore, this study proposes an algorithm for judging the anomalies in real time based on the sliding window to reproduce the color temperature of natural light. First, the natural light characteristics DB collected through the on-site measurement were analyzed, the differential values at a one-minute interval were calculated and examined, and then representative color temperature circadian patterns by solar terms were drawn. The anomalies were then detected by the application of the sliding window that calculated the deviation of the color temperature for the measured color temperature data set, which was collected through RGB sensors, while moving along the time sequence. In addition, the presence of anomalies was verified through the comparison study between the detection results and the representative circadian cycle of the color temperature by solar term. The judgment method for the anomalies from the measured color temperature of natural light was proposed for the first time, confirming that the proposed method was capable of detecting the anomalies with an average accuracy of 94.6%.

운문산반딧불이(Luciola unmunsana)의 서식지 특성과 먹이원에 관한 연구 - 전주시 산성천을 대상으로 - (The study of habitat characteristics and food sources of Luciola unmunsana - A Case Study of Sansungcheon, Jeonju City -)

  • 임현정;김종만;정문선
    • 한국환경복원기술학회지
    • /
    • 제25권3호
    • /
    • pp.83-95
    • /
    • 2022
  • This study aims to present primary data for habitat restoration and artificial breeding conditions of L. unmunsana by identifying the habitat conditions and the larvae's food sources. In order to investigate the habitat characteristics of the adult L. unmunsana and land snails, which are the primary food sources for the larvae, field surveys were conducted on a total of 10 habitats in south-central parts of Korea including Sanseongcheon, Jeonju. The results revealed that the L. unmunsana habitat in the Sanseongcheon area had a broadleaf forest with a multi-layered vegetation structure, adjacent water features, and the north/northeast/northwest slopes with little effect of artificial lighting. The adult L. unmunsana in the Sanseongcheon area appeared from the end of May to the end of June, and was especially intensively observed around the middle of June. The most active time was from 23:30 to 00:30 with a temperature range of 19~22℃ and higher than 80% humidity. The peak count of the observed adults L. unmunsana was a total of 774 on June 11, 2021. In the case of land snails, 11 families and 23 species were observed in 10 habitats of L. unmunsana, and Euphaedusa fusaniana was the most extensive and the most observed in the five survey areas. The land snails of L. unmunsana habitats are mostly found under the organic layers of leaves and a fallen tree branch in broadleaf forests, where a thick organic material layer buffers temperature changes and provides high humidity for various snails. These habitat conditions are suitable for the larva of L. unmunsana and land snails to inhabit, feed, hide and hibernate.