• Title/Summary/Keyword: Urban Energy

Search Result 1,294, Processing Time 0.028 seconds

A study on the ventilation control method of road tunnel for small vehicles (소형차 전용 도로터널의 환기기 제어방안에 대한 연구)

  • Ryu, Ji-Oh;Lee, Hu-Young;Chang, Ji-Don
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.749-762
    • /
    • 2019
  • In recent years, in urban areas, underground of roads are being promoted in order to resolve traffic congestion and to secure green spaces, and due to the low ratio of large vehicles, they are planned or constructed as road tunnels for small cars only. In addition, the tunnels being built in the city is a tendency to be enlarged to play the role of main roads. Accordingly, the capacity of the ventilation system is increasing and various ventilation methods are required, and the importance of maintenance after the completion of the tunnel such as the operating cost of the ventilation system is emphasized. Therefore, the need for optimization of the operation stage for reducing the power consumption of the ventilation system and the study of the ventilation system operation control logic is increasing. In this study, the study on the necessity of the optimization of operation stage and control logic of the ventilation system was carried out to realize the energy-saving operation for the small car only passing through tunnels which is applied of ① jet fan and combination ventilation system (② jet fan + air purifying equipment, ③ jet fan + vertical shaft, ④ jet fan + supply air semi-transverse). As a result of this study, there can be various operating combinations in the case of the combined ventilation system, and even though the amount of ventilation air is the same, the operating power varies greatly according to the operating combinations. It was found that operating the axial fan first rather than the jet fan first operation method has an effect on power saving.

Alternative to Improve the Lighting of Crosswalk on Rural Highways (지방지역 도로 횡단보도 조명 개선 방안)

  • Lee, Suk-Ki
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.3
    • /
    • pp.435-443
    • /
    • 2013
  • While rural highways carry on lower traffic volumes, the deviations of running speeds between vehicles appear to be higher on rural highways than urban highways. The speed characteristic of rural highways is adding to pedestrian-related accidents which occur on a crosswalk with poor sight distance due to the limits of car headlights and lighting. Specially, the aged was mostly occupied in nighttime-related accidents on crosswalks, and pedestrians crossing on the far side of approaching vehicles appear to have the probability of fatality higher than the near side. An alternative is needed to resolve the compounded accidents, and then this study is to establish a new approach to an optimum lighting environment on a crosswalk to improve pedestrian safety. This study was conducted by a survey and a field study on the lighting of existing crosswalks. The field study shows that the existing lighting has the problem of wasting energy and impeding walking due to glare. The survey shows that nighttime sight distance on a crosswalk is required to improve and that road users prefer to be brighter pedestrian waiting space together with the crosswalk. Thus, a lighting environment that is not too bright and illuminates the crosswalk and the pedestrian waiting space is needed to implement.

A Study on the Concentration Distribution of Airborne Heavy Metals in Major Industrial Complexes in Korea (국내 주요 산업단지 대기 중 중금속농도 분포에 관한 연구)

  • Kang, Byung-Wook;Kim, Min-Ji;Baek, Kyung-Min;Seo, Young-Kyo;Lee, Hak Sung;Kim, Jong-Ho;Han, Jin-Seok;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.2
    • /
    • pp.269-280
    • /
    • 2018
  • This paper reports the results of field evaluation to determine the levels of heavy metals in major industrial complexes in Korea over a seven year period (2007~2013). The measurement of heavy metal was conducted using quartz fiber filter sampling and ICP-AES analysis. In order to validate the analytical performance of these methods, studies were also carried out to investigate data quality control(QC) parameters, such as the method detection limit (MDL), repeatability, and recovery efficiencies. The average concentrations of total suspended particulates (TSP) for the nine industrial complexes in Korea were $104{\sim}169{\mu}g/m^3$, which was higher than other industrial complexes and urban areas. The Sihwa and Banwol industrial complexes were shown to be the biggest contributing sources to high TSP emission ($159{\mu}g/m^3$ and $169{\mu}g/m^3$, respectively). The concentrations of heavy metals in TSP were higher in the order of Fe>Cu>Zn, Pb, Mn>Cr, Ni, As and Cd. It was observed that Fe was the highest in the Gwangyang and Pohang steel industrial complexes. The concentrations of Zn and Pb were high in Onsan, Sihwa and Banwol industrial complexes, and this was attributed to the emission from the nonferrous industry. Additionally, Cr and Ni concentrations were high in the Sihwa and Banwol industrial complexes due to plating industry. On the other hand, Ulsan and Onsan industrial complexes showed high Cr and Ni concentrations as a response to the emission of metal industry related to automobile. The correlation analysis revealed the high correlation between Cr and Ni in plating industry from Sihwa and Banwol industrial complexes. Adding to this, components related to coal combustion and road dust showed high correlation in Pohang and Gwangyang industrial complexes. Then Onsan and Ulsan industrial complexes showed high correlation among components related to the nonferrous metals.

Recent Developments and Field Application of Foreign Waterworks Automatic Meter Reading (국외 상수도 원격검침시스템의 개발 동향 및 현장 적용 사례 고찰)

  • Joo, Jin Chul;Ahn, Hosang;Ahn, Chang Hyuk;Ko, Kyung-Rok;Oh, Hyun-Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.12
    • /
    • pp.863-870
    • /
    • 2012
  • The market trends of automatic meter reading associated with smart water meters were investigated. Also, recent developments and field applications of key technology for automatic meter reading associated with smart water meters were analyzed. Smart water meters have been manufactured mostly in United States and Europe and have been expanded their business to Asia. Integrated water management system combining with the additional functions such as real-time consumption metering, cost notification, water conservation, leak detection, water quality monitoring, and flow control have been operated in automatic meter reading. Both water quality and quantity data measured from smart water meters and sensors were transferred to data concentration units through neighborhood area network, and then were transferred to integrated server through wide area network. The data transfer methods were determined by comprehensively considering urban scale, density of smart water meters, power supply and network topologies. Common data collection methods such as fixed network to data concentation units, vehicles drive by, people walk by, and drone fly by have been applied. The automatic meter reading associated with smart water meters are spread throughout the world, and both water and energy savings result in saving the money and reducing the greenhouse gases emission.

A Reduction Effect in Noise Reflection by Different Shapes of Soundproofing-panel (도로소음원에 대한 방음패널 형상별 반사소음 저감효과)

  • Kim, Ilho;Park, Taeho;Chang, Seoil;Lee, Haein
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.2
    • /
    • pp.120-125
    • /
    • 2015
  • With rapid urbanization, the volume of traffic in urban area has been significantly increased. This in turn led to problem which can be described as Road Traffic Noise. Currently, to alleviate the road traffic noise damage, a demand for installation of soundproofing walls is rising. Among different shapes of soundproof walls being installed, the reflection-type acoustical insulation panel is highly drawing attentions of residents due to the fact that it does not obstruct their field of vision in contrast with the opaque acoustical insulation panel. On the other hand, improving the soundproofing wall of the reflection-type acoustical insulation barrier panel needs to be focused on since it has a possibility to cause a secondary damage by reflected sounds. Therefore, in this research, study has been carried out to improve the forms in order to minimize travelling of reflected sounds through changing the frontal surface shape and geometrical shape of the reflection-type soundproofing panel. A result from comparison between the normal reflection-type soundproofing panel and the improved soundproofing panel, with reduction effects in the noise reflection, showed that the curved type of soundproofing panel has an impact on reducing the noise up to 1.5 dB. Furthermore, from the research conducted, it appears that the increase and decrease in the reflected sounds can be changeable depending on various design factors. Thus, it turns out that the study shows a potential possibility to develop a reduction technology of the reflected sounds pertaining to overall condition on the soundproofing walls.

A Study on the Fire Prevention Activities and Suppression Measures of Utility-Pipe Conduit (지하공동구 화재예방활동 및 진압대책에 관한 연구)

  • Lee, Jung-Il
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.4
    • /
    • pp.63-68
    • /
    • 2010
  • Utility-Pipe Conduit is, Housing and city effectively accommodate what they absolutely need power, communications, gas, pipeline, water supply, drainage, energy facilities etc, according to expansion of urban infrastructure are derived, several ways to solve problems in, collection facilities in place are maintained and managed facility. If Utility-Pipe Conduit is damaged, as well as national security, because their impact on society as a whole, by introducing large vulnerability in the fire prevention activities and suppression measures and disaster for our situation by introducing measures, comprehensive analysis of the fire risk, it shall establish fire prevention activities and suppression through analysis of Utility-Pipe Conduit design, institutional issues, the problem of fire protection facilities, fire spread phenomenon etc. Because of Utility-Pipe Conduit is an enclosed place, so incomplete combustion due to lack of oxygen supply that there are problem such dark smoke, carbon monoxide etc, toxic combustion products and heat generation and visual impairment is an issue difficult to enter. As well as fire prevention activities, the fire In light of the particularity of the under ground than above ground fire, so this phenomenon is weak fire fighting that fire to become effective fire fighting tactics, basically it is necessary difficulty softening, non-burn softening and prevent combustion expansion of the cable is installed on the Utility-Pipe Conduit, having to considering the specificity of the response command system and relevant organizations to establish an on-site, Structural identification and other information gathering required to record of Response agencies, keep air conditioning system 24 hours and strengthening Virtual Total Training of Response agen

Analysis of Pollution Characteristics in the Mainstream and Its Tributaries of Gongneung Stream Using Water Quality Index and Pollution Load Data (통합수질지수 및 오염부하자료를 이용한 공릉천 유입지천과 본류의 오염특성 분석)

  • Yu, Jae-Hyun;Lee, Han-Saem;Lim, Byung-Ran;Kang, Joo-Hyoung;Ahn, Tae-Ung;Shin, Hyun-Sang
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.2
    • /
    • pp.125-136
    • /
    • 2020
  • In this study, we identified the major pollution-zones of the mainstream and its tributaries of Gongneung stream and investigated their pollution sources based on water quality, flowrate and pollution-load data of the stream having the characteristics of the urban-rural complex to examine the effect of the tributaries on the water quality changes in the mainstream. The water quality and flowrate data were collected for 10 months (2018 ~ 2019) at 3 points of mainstream and ten tributaries. Water quality index (WQI), load duration curve (LDC), discharge load density (DLD)and delivery ratios for each tributary were obtained so as to investigate the pollution characteristics and some of the information visualized on GIS. The main pollution-zone in the Gongneung stream was in the middle and lower streams, and the tributaries that may affect the pollution of the area were JS, JY, SL and SM. JS and SL had low WQI levels (34.7/37.5) and DLD (kg/d/㎢) of BOD and T-P were relatively high in JY (99.2/6.00) and SL (60.0/2.07). BOD and T-P delivery ratios in JS were high (0.94/0.83), suggesting that JS had significant influence on the water quality of the main pollution-zone in the Gongneung stream. Meanwhile, SM having a high T-P delivery ratio (0.97) was found to be more affected by the non-point source due to the higher LDC excess rate (%) in the low flow compared to high flow. This study provides basic data on the water quality and pollution characteristics of the Gongneung stream, and the analysis results are expected to be used as examples for identifying the main pollution-zone and tributaries of stream and their pollution sources.

Seismic Evaluation of Exposed Column-base Plate Weak-axis Connections Using L-shaped Hooked Anchor Bolts (L형 갈고리 앵커볼트를 사용한 약축방향 노출형 주각부의 내진성능 평가)

  • Lim, Woo-Young;You, Young-Chan
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.4
    • /
    • pp.269-280
    • /
    • 2017
  • In this study, seismic performance was evaluated for the exposed column-base plate weak-axis connections of small size steel structures through cyclic loading tests. The primary test parameters are the thickness of base plate, the presence of rib plates, the number of anchor bolts and embedment length of anchor bolts. To investigate the effect of bond performance of anchor bolts on the seismic performance of column-base plate connections, L-shaped round bars and thread bars were used as the hooked anchor bolts in the test specimens. Test results showed that bond performance of anchor bolts and the thickness of base plate significantly affect the structural performance and energy dissipation capacity. In particular, it was found that even if the requirements for minimum thickness of the base plate that is satisfied, the base plate can yield before the capacity of steel column reaches the plastic moment resulting in decreasing the structural performance of the connections. However, the proposed details of the connections might be considered as the partially restrained, that is semi-rigid connections. Consequently, the L-shaped thread anchor bolts is applicable in the exposed column-base plate weak-axis connections of small-size steel structures.

Estimation of Willingness-To-Pay for Extensive Implementation of Congestion Pricing (혼잡통행료제도 확대시행에 따른 지불의사액 추정)

  • Kim, Gun-Young;Han, Sang-Yong;Kang, Kyung-Woo;Kim, Tae-Seung
    • Journal of Korean Society of Transportation
    • /
    • v.23 no.5 s.83
    • /
    • pp.7-14
    • /
    • 2005
  • Traffic congestion causes enormous social costs as well as loss of travel time and waste of energy. Though the Seoul metropolitan government implemented various forms of transportation policies such as urban road pricing and public transportation reform, traffic volume which across the Seoul metropolitan borders have greatly increased because of housing land development in suburban area. The purpose of this study is to estimate individual's willingness-to-pay(WTP) for extensive implementation of congestion pricing through policy-mix with bus rapid transit(BRT) system. So the field survey interviews carried out. The empirical analysis was done with priority given to the following two topics; derivation of individual WTP and prior evaluation of policy effect from the equity aspect. To estimate individual WTP, we adopted contingent valuation method (CVM). The former is to estimate individual WTP for respondent's maintaining his/her transit pattern when he/she is faced with congestion pricing by using compensating variation(CV) concept. And, the latter aims at evaluating policy effect from the equity aspect by calculating the Proportion of WTP to average income using WTP in income bracket for policy scenarios.

Study of Biomass Estimation in Forest by Aerial Photograph and LiDAR Data (항공사진과 Lidar 데이터를 이용한 산림지역의 바이오매스 추정에 관한 연구)

  • Chang, An-Jin;Kim, Hyung-Tae
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.11 no.3
    • /
    • pp.166-173
    • /
    • 2008
  • Recently, problem of earth environment being attended with international issue, people are concerned about the environmentally-friendly and renewable biomass energy. Especially, the forest biomass is more important because Korea have to control carbon footprint for Kyoto Protocol and Convention on Climate Change. In case of Korea, forest area covers the land about 2/3 of all country. It is needed that more economical and efficient method to estimate the biomass by remote sensing data which include wide coverage and is progressed by one-step. In this study, we estimate forest biomass with LiDAR data and aerial photograph. Three biomass equation is used and estimate mean biomass of single tree and entire biomass in plots. The results are compared with field data. $R^2$ of the mean biomass of single tree is greater than 0.8 and that of entire biomass in plots is greater than 0.65. In conclusion, the method using remote sensing data is verified more economical and efficient than previous field data method.

  • PDF