• Title/Summary/Keyword: Upward air-water flow

Search Result 44, Processing Time 0.023 seconds

A Study on the Characteristics of Two-Phase Flow by Driven Bubbles (기포운동에 따른 2상유동 특성에 관한 연구)

  • 서동표;오율권
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.268-273
    • /
    • 2003
  • In the present study, the characteristics of upward bubble flow were experimentally investigated in a liquid bath. An electro-conductivity probe was used to measure local volume fraction and bubble frequency. Since the gas is concentrated at the near nozzle, the flow parameters are high near the nozzle. In general their axial and radial values tended to decrease with increasing distance. For visualization of flow characteristics, a Particle Image Velocimetry (P.I..V) and a thermo-vision camera were used in the present study. The experimental results show that heat transfer from bubble surface to water is largely completed within z=10mm from the nozzle, and then the temperature of bubble surface reaches that of water rapidly. Due to the centrifugal force, the flow was more developed near the wall than at bubble-water plume. Vortex flow in the bottom region was relatively weaker than that in the upper region.

A Study on the Characteristics of Two-Phase Flow by Driven Bubbles in a Liquid Bath

  • Oh, Yool-Kwon;Seo, Dong-Pyo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.1
    • /
    • pp.44-50
    • /
    • 2005
  • In the present study, the characteristics of upward bubble flow were experimentally investigated in a liquid bath. An electro-conductivity probe was used to measure local volume fraction and bubble frequency. Since the gas was concentrated at the near the nozzle, the flow parameters were high near the nozzle. In general their axial and radial values tended to decrease with increasing distance. For visualization of flow characteristics, a Particle Image Velocimetry (PIV) and a thermo-vision camera were used in the present study. The experimental results showed that heat transfer from bubble surface to water was largely completed within z = 10 mm from the nozzle, and then the temperature of bubble surface reached that of water rapidly. Due to the centrifugal force, the flow was more developed near the wall than at bubble-water plume. Vortex flow in the bottom region was relatively weaker than that in the upper region.

터빈 유량계를 사용한 이상유동의 측정

  • Sim, Jae-U
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.2 s.28
    • /
    • pp.147-152
    • /
    • 1998
  • In this study turbine flowmeters were used to predict volumetric flow rate of each phase in two-phase, gas-liquid, flowing in a vertical tube. To determine volumetric flow rates of two-phase, air-water, flowing vertically upward through the polycarbonate tube(57mm ID-inside diameter), two turbine flow meters were used. For void fraction measurements, two gamma densitometers were used at each location of the turbine flow meter, one at the upstream and the other at the downstream. It was determined that the turbine flowmeter's outputs were a function of actual volumetric flow rate of each of the two phases. A two-phase flow model was developed.

  • PDF

Vertical Upward Air-Water Two-Phase Flow Regime Identification (수직상향류 공기-물 이상유동영역 판별)

  • Lee, Ba-Ro;Jang, Young-Jun;Ko, Min-Seok;Lee, Bo-An;Lee, Yeon-Gun;Kim, Sin
    • Journal of Energy Engineering
    • /
    • v.22 no.4
    • /
    • pp.362-369
    • /
    • 2013
  • Two-phase flow is frequently observed in many industries such as nuclear power plants and oil transportation. Two-phase flow regime depends on the flow rates, the fluid properties and the structure of flow channels. Since the identification of the flow regime is of great importance in the system design and the safety analysis, a number of theoretical and experimental investigations have been performed. This paper presents a basic research on the characteristics of each flow regime and transition boundary in the two-phase flows. The flow regime of the upward air-water flow in the vertical tube, 30 mm in the inner diameter, is distinguished by using the high-speed camera and the Wire-mesh sensor(WMS). The identified experimental data are compared with the flow regime maps proposed by Taitel et al, Mishima and Ishii. Even though there is slight difference in the transition boundary, the experimental data show general agreement with these flow regime maps.

Counter-Current Flow Limit of a Vertical Two Phase (Water/Air) Flow (상반류(물/공기) 유동한계에 관한 연구)

  • 오율권;조상진;김상녕;이종원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.308-322
    • /
    • 1991
  • A set of experiments of Counter-Current Flow Limit(CCFL or Flooding) was performed to improve the drawbacks of Wallis' Correlation which neglects the effects of channel size, channel length, injection method and the boundary conditions at the inlet of liquid and gas phase. In these experiments using water and air, the followings were found ; (i) The effects of channel size and length were quite significant. In large tubes(D>20mm), the flooding front occurred at the bottom of the channel and when the gas flow increased the front moved upward ; however, in small tubes(D<20mm), there were no upward movement of flooding front and the flooding just occurred at the liquid inlet. (ii) The effect of water inlet device was not as significant as that of channel length though the inlet boundary conditions could affect the flow development and flooding afterward. (iii) Once the flooding front reached the inlet of water injection device, an newly reduced flow condition was set up and resulted in another flooding corresponding to the new condition.

The Study on the Phenomenon of Heat Transfer on a Downward Isothermal Circular Surface by an Impinging of Upward Circular Nozzle Jet (상향 원형노즐 제트에 의한 하향 등온 원형평면에서의 열전달 현상에 관한 연구)

  • Lee, In Jae;Eom, Yong Kyoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.11
    • /
    • pp.450-457
    • /
    • 2016
  • While many studies on the heat transfer effect of an impinging jet have been published, most studies focus on the downward impinging jet. This study investigates the impinging jet heat transfer phenomenon when water at a temperature of $24^{\circ}C$ impinges on the downward isothermal circular plate at 60, 70, and $80^{\circ}C$ and when the upward round jet nozzle is 4, 6, and 8 mm diameter with a flow rate 3.6, 4.6, and 5.6 L/min, respectively, and when the ratio of the nozzle clearance/nozzle diameter (H/D) is 1. The results showed that, as the nozzle diameter decreases, the heat transfer coefficient increases at a constant flow rate. The correlation equation of $Nu_r$, $Pr_r$, and $Re_{jg}$ is obtained in the impinging and constant velocity flow region $(Nu_r/Pr^{0.4}_r)Dr=4.6[Re_{jg}(r/R_c)Dr]^{0.8}$ at all flow rates, in the deceleration and falling flow regions $(Nu_r/Pr^{0.4}_r)Dr=42.7{\mid}Re_{jg}(r/R_c)Dr-345.7{\mid}^{0.3}$ at 3.6 L/min, $(Nu_r/Pr^{0.4}_r)Dr=92.4{\mid}Re_{jg}(r/R_c)Dr-16.8{\mid}^{0.2}$ at 4.6 L/min, and $(Nu_r/Pr^{0.4}_r)Dr=322.4{\mid}Re_{jg}(r/R_c)Dr-536.2{\mid}^{0.01}$ at 5.6 L/min.

The Characteristics of Two-Phase Flow Distribution in a Bottom Dividing Header

  • Im, Yang-Bin;Kim, Jang-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.8
    • /
    • pp.1195-1202
    • /
    • 2004
  • In this paper an experimental study was investigated for two-phase flow distribution in compact heat exchanger header. A test section was consisted of the horizontal bottom dividing header($\phi$: 5 mm, L: 80 mm) and 10 upward circular mini channels ($\phi$: 1.5 mm, L: 850 mm) using an acrylic tube. Three different types of tube intrusion depth were tested for the mass flux and inlet mass quality ranges of 50 - 200 kg/$m^2$s and 0.1 - 0.3, respectively. Air and water were used as the test fluids. The distribution of vapor and liquid is obtained by measurement of the total mass flow rate and the calculation of the quality. Two-phase flow pattern was observed, and pressure drop of each channel was measured. By adjusting the intrusion depth of each channel an uniform liquid flow distribution through the each channel was able to solve the mal-distribution problem.

An Experimental Study on the Melting of Horizontal Ice - Bar Located Concentrically in the Cylinder (수평원관속에 동심으로 놓여있는 얼음 봉의 융해현상에 관한 보험적 연구)

  • Lee, Dong-Wook;Yoo, Sang-Sin
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.2
    • /
    • pp.196-203
    • /
    • 1986
  • The melting phenomena of horizontal cylindrical ice-bar immersed in water and air concentrically in the cylinder are experimentally investigated for the temperature range from $3.5^{\circ}C\;to\;2.5^{\circ}C$. The shapes of the melting ice-bar are recorded photographically by the shadowgraph method. The shadowgraphs of the melting ice-bar show that water adjacent to the bar flows upward for the temperature range from $3.5^{\circ}C\;to\;5.8^{\circ}C$ while above $5.8^|\circ}C$ the flow is downward direction. The local and average Nusselt numbers are obtoined with the recorded shadowgraphs and comparator. Melting shapes of the ice-bar in the air show the vortex motion in the bottom portion of the bar, whereas no vortex motion appears in the bottom portion when the bar is melted in the water.

  • PDF

Experimental Study on Flow Patterns and Pressure Drop Characteristics of Ice Slurry in Small Size Pipe (2) (소구경 배관내 아이스슬러리의 유동형상 및 압력강하 특성에 관한 실험적 연구(2))

  • 이동원;윤찬일;주문창
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.5
    • /
    • pp.391-397
    • /
    • 2002
  • Pressure drop were experimentally investigated for ice slurry flowing in the acrylic pipes with inner diameter of 24 mm. Ice slurry was made from 6.5% ethylene glycol-water solution, and the pipes is consisted of horizontal, vertical (upward and downward) and $90^{\circ}$ elbow pipe. The ice Packing factor (IPF) and the flow rate of the experiments were varied from 0 to 30% and from 5 to 70kg/min respectively The measured pressure drop in various pipe positions were compared with those for the solution flow (IPF=0). The pressure drop was larder than that for solution flows as the IPF increased when the flow rate was low or very high. Sharp increases in pressure drop were observed for the cases when IPF is more than 70% in horizontal and vertical pipes, whereas the pressure drop increased with the IPF simultaneously in an elbow pipe.

Experimental study on vertically upward steam-water two-phase flow patterns in narrow rectangular channel

  • Zhou, Jiancheng;Ye, Tianzhou;Zhang, Dalin;Song, Gongle;Sun, Rulei;Deng, Jian;Tian, Wenxi;Su, G.H.;Qiu, Suizheng
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.61-68
    • /
    • 2021
  • Experiments of vertically upward steam-water two-phase flow have been carried out in single-side heated narrow rectangular channel with a gap of 3 mm. Flow patterns were identified and classified through visualization directly. Slug flow was only observed at 0.2 MPa but replaced by block-bubble flow at 1.0 MPa. Flow pattern maps at the pressure of 0.2 MPa and 1.0 MPa were plotted and the difference was analyzed. The experimental data has been compared with other flow pattern maps and transition criteria. The results show reasonable agreement with Hosler's, while a wide discrepancy is observed when compared with air-water two-phase experimental data. Current criteria developed based on air-water experiments poorly predict bubble-slug flow transition due to the different formation and growth of bubbles. This work is significant for researches on heat transfer, bubble dynamics and flow instability.