• Title/Summary/Keyword: Upper arm

Search Result 717, Processing Time 0.03 seconds

The Effect of Upper Extremity Usage and Length of Training to the Function of Dance Turn (상지 이용 유무와 훈련 기간이 무용 회전 동작의 기능에 미치는 영향)

  • Park, Yang-Sun;Lim, Young-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.1
    • /
    • pp.175-184
    • /
    • 2007
  • The first purpose of this study was to compare kinematic variables during spinning motion with or without upper extremity and identify the most effective spinning method. The second purpose of this study was to compare functional difference between novice and elite dancers with the term of training. Ten experienced female dancers and ten novices were recruited as subjects for this study. Elite group was asked to perform turn motion with three types of upper extremity. Novice group has taken training of spotting technique for five weeks. Four Falcon HiRES cameras were used to analyze kinematic variables including head angular velocity and CG displacement during spinning. These data were sampled before training, after 3-week, and 5-week of training. Eight different events in two consecutive turns were defined for statistical comparison. One-way ANOVA was performed to compare among the kinematics of turning motion with three types of upper extremity. Independent t-test also used to compare kinematics between elite and novice at three different length of training. As results, spinning with both arm increased angular velocity and stability compared to the turning motion with one arm or with arm strapped and found out that the turn with both arm was the most effective way of spin. Also, for novice dancers, three weeks of training were needed to complete spinning motion.

The survey on the skin color and pigmentation index in Korean adult subjects

  • Cho, Joon-Hwan;Yun, Ju-An;Bae, Ji-Yeon;Ha, Jea-Hyon
    • Proceedings of the SCSK Conference
    • /
    • 2003.09b
    • /
    • pp.438-447
    • /
    • 2003
  • We selected 113 subjects (male:59, female:54) in 20 to 29 age and observed the skin color difference between female and male. Also we measured the minimal persistent pigment darkening dose (MPPD) in same subjects. The skin colors of upper inner arm and back were measured with chromameter (CR10, Minolta, Japan) which represents skin color as $L^{*}$, $a^{*}$, and $b^{*}$ in value. MPPD was measured with solar simulator multi-port 601(Solarlight Co. USA). All statistical analysis was performed on the computer software package SPSS 8.0. The skin colors between male and female was significant difference in back and upper inner arm. There was significant difference of skin colors between back and upper inner arm in both male and female. There was no relationship existed between the values of MPPD and skin color ( $L^{*}$ $a^{*}$ $b^{*}$) of back in both male and female. As a result of survey, we knew that there was apparent difference of skin color between back and upper inner arm due to gender. Also we hope these data will be helpful to study on the correlation of the pigmentation index and skin color.(omitted)omitted)ted)

  • PDF

The Effects of Task-oriented Training Using the PNF in Upper Arm Function and Activities of Daily Living with Chronic Stroke Patients (PNF를 이용한 과제지향훈련이 만성뇌졸중환자의 상지기능과 일상생활수행능력에 미치는 영향)

  • Bang, Dae-hyouk;Jeong, Wang-Mo;Bong, Soon-Nyung
    • PNF and Movement
    • /
    • v.11 no.2
    • /
    • pp.41-48
    • /
    • 2013
  • Purpose : The aim of this study was to compare the effect of task-oriented training using the PNF(proprioceptive neuromuscular facilitation) and task-oriented training with chronic stroke patients. Methods : Sixteen chronic stroke patients participated. Participants were randomly assigned to the control and experimental group( 8 experimental, 8 control). All of participants were in-patients at local hospital and had been received training appropriate to the purpose of each group program. Experimental period was carried out 30 minutes/day, five days/week, during four weeks. The experimental group trained the task-oriented training using the PNF and control group trained the task-oriented training. Fugl-meyer assessment scale and Modified Barthel Index was measured to compare the upper arm function and activities of daily living. We were measured before and after the training. Results : The results of the study were as follow: Fugl-meyer assessment scale was significantly increased both groups(p<.05), and significant between groups(p<.05). Modified Barthel index was significantly increased both groups(p<.05) and between groups(p<.05). Conclusion : PNF can be effective in improving upper arm function and ability to perform daily life of chronic stroke patients.

NREH: Upper Extremity Rehabilitation Robot for Various Exercises and Data Collection at Home (NREH: 다양한 운동과 데이터 수집이 가능한 가정용 상지재활로봇)

  • Jun-Yong Song;Seong-Hoon Lee;Won-Kyung Song
    • The Journal of Korea Robotics Society
    • /
    • v.18 no.4
    • /
    • pp.376-384
    • /
    • 2023
  • In this paper, we introduce an upper extremity rehabilitation robot, NREH (NRC End-effector based Rehabilitation arm at Home). Through NREH, stroke survivors could continuously exercise their upper extremities at home. NREH allows a user to hold the handle of the end-effector of the robot arm. NREH is a end-effector-based robot that moves the arm on a two-dimensional plane, but the tilt angle can be adjusted to mimic a movement similar to that in a three-dimensional space. Depending on the tilting angle, it is possible to perform customized exercises that can adjust the difficulty for each user. The user can sit down facing the robot and perform exercises such as arm reaching. When the user sits 90 degrees sideways, the user can also exercise their arms on a plane parallel to the sagittal plane. NREH was designed to be as simple as possible considering its use at home. By applying error augmentation, the exercise effect can be increased, and assistance force or resistance force can be applied as needed. Using an encoder on two actuators and a force/torque sensor on the end-effector, NREH can continuously collect and analyze the user's movement data.

Apparel Fit by Body Perception and Body Satisfaction (신체만족도와 신체인지도에 따른 의복맞음성(Apparel Fit) 만족도)

  • 이경림;박숙현
    • Journal of the Korean Society of Costume
    • /
    • v.54 no.1
    • /
    • pp.69-81
    • /
    • 2004
  • The purpose of this study was to find out apparel fit satisfaction according to item(jacket, pants, skirt) by body perception and body satisfaction. This research was done by a survey method. Descriptive Statistics, Pearson's Correlation, Crosstabs were used for data analysis. The results of this study are as follows. 1) Correlation between body perception and body satisfaction : The subjects were less satisfied with larger or thicker girth of upper body. The subjects were less satisfied with thicker upper arm, lower arm, waist and lower abdomen. The subjects were more satisfied with taller height. The subjects were less satisfied with larger or thicker girth of lower body. The subjects were less satisfied with thicker hips. thighs, calves, ankles, and longer crotch length. However, they were more satisfied with longer legs. 2) Apparel fit by body perception and body satisfaction: The subjects who were less satisfied with thicker upper arm, waist, thighs and wider hips were less satisfied with the upper arm area, waist area. hip area of jacket. The subjects who were more satisfied with longer arms were more satisfied with the sleeve length of jacket. The subjects who were less satisfied with wider shoulder width were less satisfied with the upper back width of jacket. It means the shoulder width affected more the upper back width of jacket than shoulder width of jacket. The subjects who were less satisfied with wider hips were less satisfied with the hip area of pants and skirt. The subjects who were less satisfied with thicker thighs were less satisfied with the thigh area and the hip area of pants and skirt. The subjects who were less satisfied with longer crotch length were less satisfied with the crotch length of pants. 3) Difference between actual body and perceived body by Rohrer Index: Rohrer Index 109 calculated by average of the ideal height(165.83cm) and weight(49.78kg) of the subjects ranged in thin body type(below 120). The subjects tended to perceived their bodies fatter than their actual bodies. Also, the subjects tended to perceived their lower bodies fatter than upper bodies.

Studies on Garment Restraint(II) - Change of Skin Temperature by Intermittent Restraint Method - (의복의 구속성에 관한 연구(II) - 단속적인 구속방법에 따른 피부온 변화에 대하여 -)

  • Shim, Boo-Ja
    • Journal of the Korean Society of Costume
    • /
    • v.16
    • /
    • pp.173-185
    • /
    • 1991
  • We measured change of peripheral skin temperature and mean skin temperature when the upper arm and thigh pressured in order to know the effect of skin pressure applied by clothing on blood circulation. After release from pressure, we observed also recovery condition. At the same time, we examined relation between pressure and a feeling of tightness. Three physiques of healthy females, namely slender, standard and plump, served as subjects. We used intermittent method with skin pressure applied by experimental fabric at l-minute intervals. Besides we made a comparative study with results according to different restraint method (continuous method and intermittent method). As a result of this experiment, we obtained following findings. 1. The significant difference was marked at the pressure, measuring time, physique and measuring region with change of skin temperature under upper arm and thigh restraint by intermittent method. The peripheral skin temperature decreased with the lapse of restraint time. A remarkable tendency observed according to the. increase of restraint pressure. Recovery condition after release from pressure not yet recovered to original state, for all after a lapse of 10 min. The mean skin temperature decreased with the lapse of restraint time in case of upper arm restraint, it was not an obvious tendency except 60mmHg under thigh restraint. 2. Main factor affecting the evaluation of a feeling of tightness was restraint pressure, when the upper arm and thigh restraint by intermittent method. The respondence rate of 'very tight' grew larger according to the increase of restraint pressure. The value of pressure sensation declined after restraint ten times as compared with one time, but there was difference according to restraint pressure. 3. We reexamined change of skin temperature and feeling of tightness by different restraint method(continuous method and intermittent method). The results were as follows. 1) The skin temperature decreased more greatly during skin pressure by continuous method than intermittent method, especially in the peripheral. Without different restraint method, the skin temperature of slender plysique decreased more greatly than that of plump physique. 2) The value of pressure sensation by intermittent method was highly on both sites of upper arm and thigh.

  • PDF

Efficacy of mid-upper arm circumference in identification, follow-up and discharge of malnourished children during nutrition rehabilitation

  • Mogendi, Joseph Birundu;De Steur, Hans;Gellynck, Xavier;Saeed, Hibbah Araba;Makokha, Anselimo
    • Nutrition Research and Practice
    • /
    • v.9 no.3
    • /
    • pp.268-277
    • /
    • 2015
  • BACKGROUND/OBJECTIVES: Although it is crucial to identify those children likely to be treated in an appropriate nutrition rehabilitation programme and discharge them at the appropriate time, there is no golden standard for such identification. The current study examined the appropriateness of using Mid-Upper Arm Circumference for the identification, follow-up and discharge of malnourished children. We also assessed its discrepancy with the Weight-for-Height based diagnosis, the rate of recovery, and the discharge criteria of the children during nutrition rehabilitation. SUBJECTS/METHODS: The study present findings from 156 children (aged 6-59 months) attending a supplementary feeding programme at Makadara and Jericho Health Centres, Eastern District of Nairobi, Kenya. Records of age, weight, height and mid-upper arm circumference were selected at three stages of nutrition rehabilitation: admission, follow-up and discharge. The values obtained were then used to calculate z-scores as defined by WHO Anthro while estimating different diagnostic indices. RESULTS: Mid-upper arm circumference single cut-off (< 12.5 cm) was found to exhibit high values of sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio at both admission and discharge. Besides, children recorded higher rate of recovery at 86 days, an average increment of 0.98 cm at the rate of 0.14mm/day, and a weight gain of 13.49gm/day, albeit higher in female than their male counterparts. Nevertheless, children admitted on basis of low MUAC had a significantly higher MUAC gain than WH at 0.19mm/day and 0.13mm/day respectively. CONCLUSIONS: Mid-upper arm circumference can be an appropriate tool for identifying malnourished children for admission to nutrition rehabilitation programs. Our results confirm the appropriateness of this tool for monitoring recovery trends and discharging the children thereafter. In principle the tool has potential to minimize nutrition rehabilitation costs, particularly in community therapeutic centres in developing countries.

Thermal Characteristics Analysis of Upper Arm Hybrid Structure of Lightweight Pantograph Considering Heat Source by Collecting Current (집전전류에 의한 열원을 고려한 경량 판토그래프 상부암 혼성구조체의 열 특성 분석 연구)

  • Park, Chan-Bae;Jeong, Geochul
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.4
    • /
    • pp.466-473
    • /
    • 2017
  • Recently, domestic railway related institutes are developing pantographs for high speed trains; to lighten the upper arm, this device has a composite structure of CFRP (Carbon Fiber Reinforced Plastic) and aluminum instead of conventional steel. In the case of KTX-Sancheon, the pantograph must have a large current capacity because this system is of power-car type, supplying all necessary power for the train through a single pantograph. If the thickness of the pipe is arbitrarily increased in order to increase the current carrying capacity, without analyzing the thermal characteristics of the aluminum pipe, the increase in the weight of the upper arm may cause degradation of the current collecting performance. Therefore, in this paper, using the thermal analysis technique, we analyze the temperature change characteristics of the aluminum pipe of the upper arm over time, while receiving power at the stationary state of the KTX-Sancheon; we also examine the adequacy of the minimum thickness of the aluminum pipe in accordance with the proposed pantograph flow capacity.

Inspiratory Muscle Strengthening Training Method to Improve Respiratory Function : Comparison of the Effects of Diaphragmatic Breathing with Upper Arm Exercise and Power-Breathe Breathing (호흡 기능 향상을 위한 들숨근 강화 훈련 방법 : 위팔운동을 동반한 가로막 호흡과 파워브리드 호흡의 효과 비교)

  • Lee, Keon-Cheol;Choo, Yeon-Ki
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.3
    • /
    • pp.203-211
    • /
    • 2021
  • Purpose : It was to compare changes in respiratory function (pulmonary function, inspiratory function) after four weeks of inspiratory muscle strengthening training (diaphragmatic breathing with upper arm exercise, Power-Breathe breathing) for 36 healthy people. Methods : Subjects were randomly assigned to diaphragmatic breathing with upper arm exercise (Group I) and Power-breathe breathing (Group II) was conducted by the protocol for four weeks five times per week. As the main measurement method for comparison between groups For pulmonary function, Forced Vital Capacity (FVC) and Forced Expiratory Volume at One second (FEV1) were used, and for inspiratory function, Maximum Inspiratory Capacity (MIC), Maximum Inspiratory Pressure (MIP), and Maximum Inspiratory Flow Rate (MIFR) were used. Results : In changes in pulmonary function between groups, FVC and FEV1 showed no significant difference, and in inspiratory function changes, MIC showed no significant difference, but in MIP and MIFR, Group B significantly improved over Group A. Conclusion : The progressive resistance training using the Power-breath device applied to the inspiratory muscle did not show a significant difference in the increase in the amount of air in the lungs and chest cage compared to the diaphragmatic breathing training accompanied by the upper arm exercise. However, by increasing the air inflow rate and pressure, it showed a more excellent effect on improving respiratory function.

Analysis of breast Replicas of Elementary School Girls (초등학교 여학생의 유방 레플리카 분석)

  • 이경화
    • Journal of the Korean Home Economics Association
    • /
    • v.37 no.11
    • /
    • pp.49-58
    • /
    • 1999
  • This study is to develop the well-fit brassieres by observing the changes in the breast sizes and shapes, the surface area of the breast through the arm movements of 3 types (0$^{\circ}$ , 90$^{\circ}$ and 180$^{\circ}$) in vortical motion. The 11 elementary girls who are aged 12 participated in this experiment. To obtain the measures regarding the surface area of the breast, replicas are made at each motion. The results of this study are as fellows: 1. The changes in the breast sizes and shapes at each motion By increasing the motions of the arm movement, the following measure items are inclined to decrease: Shoulder length, Upper blast girth, Bust girth, Under bust girth, Upper bust depth, Bust depth, Under bust depth, Nipple to nipple breadth, Horizontal distance of bust, Horizontal length of the cup, Bust height, Cup size. By increasing the motions of the arm movement, the fellowing measure items are inclined to increase: Center point of shoulder~B.p., Shoulder point~B.p., Center point of shoulder~armpit, Upper Bust breadth, Bust breadth, Under bust breadth, Vertical distance of Bust. 2. The changes in the surface area of breast at each motion By making the replica to observe changes in the surface area, which are sectioned to 4 parts(area 1 to area 4), and volume of breast at each motion, the results are as follows: At 0$^{\circ}$and 180$^{\circ}$, the sizes of each part are ordered as the following: area2>area1>area4> area3. At 90$^{\circ}$, the sizes of each part are ordered as the following: area2>area1>area3>area4. Through these orders, it is found that the upper and inside part of the breast huts the inclination to increase so along as the motions of the arm movement increase. Also, the total surface area increases so long as the motions of the arm movement increase. As a reset of the F-test on the changes in the each surface areas, the surface area by arm movements, the significant differences among the each surface areas are found.

  • PDF