• 제목/요약/키워드: Unstable Behavior

검색결과 338건 처리시간 0.024초

SiC입자와 Al-Ti합금 용탕간반응에 의한 in situ 생성 TiC입자강화 Al합금복합재료의 조직과 기계적특성 (Microstructure and Mechanical Properties of in situ TiCp/Al Composites Fabricated by the Interfacial Reaction between SiC Particles and Liquid Al-Ti Alloy)

  • 임석원;중전박도
    • 한국주조공학회지
    • /
    • 제17권2호
    • /
    • pp.170-179
    • /
    • 1997
  • A noble technique has been developed for fabricating in situ formed $TiC_p/Al$ composites. In this process, fairly stable TiC particles were in situ synthesized in liquid aluminum by the interfacial reaction between an Al-Ti melt and SiC, which is a comparatively unstable carbide from the view-point of thermodynamics. It is possible in the present process to generate TiC particles of nearly 1 ${\mu}m$ in diameter, even utilizing SiC of 14 ${\mu}m$ as raw material. However, the dispersion behavior of TiC particles in the matrix depends on the size of the raw material SiC. Decomposing finer SiC makes the dispersion of TiC particles more uniform and the mechanical properties of composites are improved accordingly. The structure of in situ composites and their mechanical properties are affected by the fabrication temperature and the stirring time. It has been found that the most suitable condition for fabrication should be applied depending on the size of the raw material, even if the same kinds of carbide are used. Furthermore, although Al-Ti-Si system intermetallic compounds are detected in a $TiC_p/Al-Si$ composite which is fabricated by conventional melt-stirrng method, these compounds can not be observed in a $TiC_p/Al-Si$ composite made by this in situ production method. Hence the mechanical properties of the in situ $TiC_p/Al-Si$ composite are superior to those of the conventional $TiC_p/Al-Si$ composites.

  • PDF

Zr-2.5Nb 중수로 압력관의 조사후 강도 및 파괴거동 특성 (The Strength and Fracture Behavior characteristics of Irradiated Zr-2.5Nb CANDU Pressure Tube Materials)

  • 안상복;김영석;김정규
    • 대한기계학회논문집A
    • /
    • 제25권3호
    • /
    • pp.510-519
    • /
    • 2001
  • The tensile and fracture toughness tests have been conducted to investigate the degradations of mechanical properties induced mainly by neutron irradiations in Zr-2.5Nb CANDU pressure tube materials operated in Wolsung Unit-1. the tests were performed at room, 150, 200, 250, 300 $\^{C}$ for the irradiated and unirradiated specimens in hot cell. The specimens were directly machined from the tube retaining original curvature using specially designed electric discharge machine(EDM). From the tensile tests of the irradiated specimens, it was found that tensile strength was increased and total elongation was decreased compared to those of the unirradiated ones. The active voltages in the fracture toughness tests for the irradiated showed the discontinuous abrupt increases caused by crack jumping in lower temperature. In the crack resistance curves we found the stable crack growth in the unirradiated, whereas the unstable and three crack growth stages in the irradiated specimens due to the accumulated irradiation defects. The various fracture characteristic values in the irradiated are remarkably lower than those of the unirradiated. Through the fractography, we found in the irradiated that smaller dimple and shorter fissures than the unirradiated, and that the fractured surface had three regions that were flat, transition and slant/shear area. These can explain the difference in the crack growth characteristic values of the irradiated and the unirradiated ones.

난류 모형에 따른 수직 평판 위 파동 액막류의 수치해석 연구 (Numerical Study of Wavy Film Flow on Vertical Plate Using Different Turbulent Models)

  • 민준기;박일석
    • 대한기계학회논문집B
    • /
    • 제38권5호
    • /
    • pp.373-380
    • /
    • 2014
  • 액막류는 다양한 산업분야에 적용되는 쉘-튜브 열교환기의 주요 열교환기구로 오랫동안 연구되어왔다. 액막류의 한쪽 경계는 고정벽에 접하고 있지만 반대편에서는 기체 영역과 경계를 형성하므로 액막 레이놀즈 수가 증가함에 따라 쉽게 불안정해지는 특징을 가지고 있다. 따라서 레이놀즈 수가 증가함에 따라 자유표면 파동 현상이 나타나는데, 층류 영역에서는 큰 진폭의 고립파가, 난류 천이 이후에는 낮은 진폭의 물결파가 나타난다. 액막류의 열전달 성능은 액막의 두께에 의해 크게 지배받는데 액막류에 동반된 파동은 액막 두께의 시공간적 변화를 의미하는 것이므로 이에 대한 정보를 해석적으로 수집하는 것은 액막류 열전달 성능을 예측하는데 필수적이다. 본 연구에서는 낮은 진폭의 물결파를 동반한 난류 액막류에 대하여 여러 가지 난류 모형을 적용한 해석결과들을 실험결과와 비교함으로써 난류 모형들에 대한 평가를 실시하였다.

비정상 호흡 감지를 위한 신호 분석 (Signal Analysis for Detecting Abnormal Breathing)

  • 김현진;김진현
    • 센서학회지
    • /
    • 제29권4호
    • /
    • pp.249-254
    • /
    • 2020
  • It is difficult to control children who exhibit negative behavior in dental clinics. Various methods are used for preventing pediatric dental patients from being afraid and for eliminating the factors that cause psychological anxiety. However, when it is difficult to apply this routine behavioral control technique, sedation therapy is used to provide quality treatment. When the sleep anesthesia treatment is performed at the dentist's clinic, it is challenging to identify emergencies using the current breath detection method. When a dentist treats a patient that is under the influence of an anesthetic, the patient is unconscious and cannot immediately respond, even if the airway is blocked, which can cause unstable breathing or even death in severe cases. During emergencies, respiratory instability is not easily detected with first aid using conventional methods owing to time lag or noise from medical devices. Therefore, abnormal breathing needs to be evaluated in real-time using an intuitive method. In this paper, we propose a method for identifying abnormal breathing in real-time using an intuitive method. Respiration signals were measured using a 3M Littman electronic stethoscope when the patient's posture was supine. The characteristics of the signals were analyzed by applying the signal processing theory to distinguish abnormal breathing from normal breathing. By applying a short-time Fourier transform to the respiratory signals, the frequency range for each patient was found to be different, and the frequency of abnormal breathing was distributed across a broader range than that of normal breathing. From the wavelet transform, time-frequency information could be identified simultaneously, and the change in the amplitude with the time could also be determined. When the difference between the amplitude of normal breathing and abnormal breathing in the time domain was very large, abnormal breathing could be identified.

생물막공법을 이용한 도시하수처리에 관한 연구 (A Study on the Municipal Wastewater Treatment Using Biofilm Process)

  • 곽병찬;탁성제;김남천;황용우
    • 상하수도학회지
    • /
    • 제14권1호
    • /
    • pp.62-75
    • /
    • 2000
  • Most of biological treatment to remove contaminants in municipal wastewater have been conducted by activated sludge process. But, the process have several probIems such as enormous site needed for construction of treatment facilities, unstable treatment due to limited ability to control load fluctuation, frequent sludge bulking and appearance of lots of surplus sludge. In this study, the experiments were performed through submerging biofilm of PEPP media in existing aeration tank with raw water from municipal wastewater treatment plant and then submerging PVDC and PEPP media, different from shape and chemical peculiarity in anoxic reactor. Throughout the experience, nutrient removal efficiency according to HRT, nitrogen phosphorous removal efficiency, behavior of nitrogen and dewatering efficiency have been compared and analysed with those of activated sludge process. As the results, BOD removal efficiency according to BOD volumetric load and F/M ratio was not found any differency in two processes, but was decreased below 90% as going along the condition of high load in activated sludge process. Kinetic coefficient was $K_{max}=1.162day^{-1}$, $K_s=53.77mg/L$, $Y=0.166mgVSS/mgBOD_{rem}$. and $K_d=0.019day^{-1}$. It was found that the removal efficiency, even though in aerobic condition, in biofilm process equipped anoxic reactor was higher than the one in activated sludge process within the range of 70~80%, and became better as HRT increased. Phosphorous removal efficiency was not found any differency in two processes. In biofilm process, treament efficiency even in conditions of high load was not decreased, because the biomass concentration could be maintained in high condition compared with activated sludge process. As HRT increased, suspended and attached biomass was increased and the other hand, F/M ratio was decreased as biomass' increasing. Biomass thickness was increased. from $10.43{\mu}m$ to $10.55{\mu}m$ as HRT increased and density of biomass within $40.79{\sim}41.16mg/cm^2$. The results also present that the dewatering efficiency of sludge generated in biofilm process was higher than in activated sludge process, and became better as HRT increased.

  • PDF

산화제 첨가에 따른 W-CMP 특성 (W Chemical Mechanical Polishing (CMP) Characteristics by oxidizer addition)

  • 박창준;서용진;이경진;정소영;김철복;김상용;이우선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.46-49
    • /
    • 2003
  • Chemical mechanical polishing (CMP) is an essential dielectric planarization in multilayer microelectronic device fabrication. In the CMP process it is necessary to minimize the extent of surface defect formation while maintaining good planarity and optimal material removal rates. The polishing mechanism of W-CMP process has been reported as the repeated process of passive layer formation by oxidizer and abrasion action by slurry abrasives. Thus, it is important to understand the effect of oxidizer on W passivation layer, in order to obtain higher removal rate (RR) and very low non-uniformity (NU%) during W-CMP process. In this paper, we compared the effects of oxidizer or W-CMP process with three different kind of oxidizers with 5% hydrogen peroxide such as $Fe(NO_3)_3$, $H_2O_2$, and $KIO_3$. The difference in removal rate and roughness of W in stable and unstable slurries are believed to caused by modification in the mechanical behavior of $Al_3O_3$ particles in presence of surfactant stabilizing the slurry.

  • PDF

층류 부상 화염의 화염부상 높이 감소 구간에서 교류 전기장이 인가된 화염에 관한 영향 (Effect of AC Electric Field on Decreasing Liftoff Height in Laminar Lifted Jet Flames)

  • 서보현;반규호;김경택;박정;길상인;김세원;정석호
    • 한국연소학회지
    • /
    • 제22권3호
    • /
    • pp.17-22
    • /
    • 2017
  • An experimental study has been conducted to elucidate the effect of AC electric field on behaviors of laminar lifted flame in nitrogen-diluted methane coflow-jets. Our concerns are focued on the regime to show a decrease in liftoff height, $H_L$ with increasing nozzle exit velocity, $U_O$ (hereafter, $decreasing-H_L$). The $H_L$ with $U_O$ near flame extinction were measured by varying the applied AC voltage, $V_{AC}$ and frequency, $f_{AC}$ in a single electrode configuration. The behavior of $H_L$ with a functional dependency of $V_{AC}$ and $f_{AC}$ was categorized into two regime : (I) $H_L$ decreased for nozzle diameter, D = 1.0 mm, and (II) $H_L$ increased in the increase of $f_{AC}$ for a fixed $V_{AC}$ in a D = 4.0, 8.4 mm. The lifted flames in $decreasing-H_L$ region was unstable in high voltage regimes while the $H_L$ showed a decreasing tendency with $U_O$ except them. Such behaviors in $H_L$ were also characterized by functional dependencies of related physical parameters such as $V_{AC}$, $f_{AC}$, $U_O$, fuel mole fraction ($X_{F.O}$) and D.

강원도 정선군 고한 지역 붕괴사면의 수치해석을 이용한 사면안정성 평가 (Stability Evaluation of failed Slope in Gohan, Korea using Numerical Analysis)

  • 장현식;이주용;서용석;장보안
    • 지질공학
    • /
    • 제24권4호
    • /
    • pp.511-523
    • /
    • 2014
  • 확장공사 중 큰 규모의 붕괴가 발생한 사면에 대하여 현재와 확장공사 완료 후의 안정성을 평가하기 위하여 한계평형법과 유한차분법을 이용하여 안정해석을 실시하였다. 이 지역은 복잡한 공학적 특성을 갖는 붕적층이 존재하여 안정해석을 위한 해석모델 결정이 쉽지 않다. 따라서 실제 사면의 상태를 반영하는 해석모델을 만들기 위해 경계면(파괴면)의 형상과 지반강도정수를 변화시켜가며 역해석을 실시하여 최종적인 해석모델을 결정하였다. 대책공법으로 고려한 억지말뚝이 적용된 해석모델은 비교적 안정한 상태로 분석되었으며, 이러한 해석결과는 실제 사면의 상태와 일치하는 것이다. 또한 이 연구에서 제시된 해석모델과 지반물성은 향후 계획중인 사면 절취공사 시 지반의 안정성을 확보하는데 기초자료로 사용될 수 있을 것으로 판단된다.

화학적 전처리를 통한 혐기성 슬러지 처리효율의 향상 (Performance Enhancement of Anaerobic Treatment of Waste Sludge by Chemical Pretreatment)

  • 허준무;박종안;손부순
    • 환경위생공학
    • /
    • 제13권1호
    • /
    • pp.16-25
    • /
    • 1998
  • Laboratory-scale experiment using anaerobic fluidized bed reactor was carried out to investigate the prehydrolysis step with caustic soda on the treatment efficiency of anaerobic sludge treatment, since the overall rate-limiting step for the complete anaerobic digestion of sludge was the hydrolysis step by extracellular bacterial enzymes of insoluble polymeric molecules. Reactors received a sludge which had not been pretreated, a 50-50 mixture of pretreated and untreated sludge, and the fully pretreated sludge. Hydraulic retention time of 10, 5, 2.5 days and 1 day were applied with an respective equivalent organic loading rate of 1.17, 2.23, 4.17, 11.24 gCOD/L/d. Reactor with the untreated sludge did not archieve adequate digestion even at the HRT of 5 days, and reactor, which received the 50-50 mixture, operated well at the HRT of 5 days, but began to show signs of unstable digestion at the HRT of 2.5 days. While, reactor, which was fed the hydrolyzed sludge, operated reasonably well at the 2.5 days, but was showing somewhat decrease in removal efficiencies. Results, therefore, have substantiated that the limiting reaction in the anaerobic treatment process is hydrolysis. The soluble COD did not significantly accumulate in the reactor as organic acid form, even when they were highly stressed. It was believed that this resistance to a build-up of organic acids and soluble COD behavior was mainly due to the maintenance of the methane bacteria in the fixed-film system which prevents washout as the organic loading increased. The anaerobic fluidized bed reactor was therefore effective for the digestion of waste activated sludge at short HRT.

  • PDF

벌크 비정질 용사코팅과 비정질 기지 복합재료의 건조 마찰특성 (Dry Friction Characteristics of Bulk Amorphous Thermal Spray Coating and Amorphous Metallic Matrix Composites)

  • 장범택;이승훈
    • Tribology and Lubricants
    • /
    • 제30권2호
    • /
    • pp.108-115
    • /
    • 2014
  • The friction behaviors of bulk amorphous thermal spray coating (BAC) and second phase-reinforced composite coatings using a high velocity oxy-fuel spraying process were investigated using a ball-on-disk test rig that slides against a ceramic ball in an atmospheric environment. The surface temperatures were measured using an infrared thermometer installed 50 mm from the contact surface. The crystallinities of the coating layers were determined using X-ray diffraction. The morphologies of the coating layers and worn surfaces were observed using a scanning electron microscope and energy-dispersive spectroscopy. The results show that the friction behavior of the monolithic amorphous coating was sensitive to the testing conditions. Under lower than normal loads, a low and stable friction coefficient of about 0.1 was observed, whereas under a higher relative load, a high and unstable friction coefficient of greater than 0.3 was obtained with an instant temperature increase. For the composite coatings, a sudden increase in friction coefficient did not occur, i.e., the transition region did not exist and during the friction test, a gradual increase occurred only after a significant delay. The BAC morphology observations indicate that viscous plastic flow was generated with low loads, but severe surface damage (i.e., tearing) occurred at high loads. For composite coatings, a relatively smooth surface was observed on the worn surface for all applied loads.