• Title/Summary/Keyword: Unsaturated Flow

Search Result 191, Processing Time 0.028 seconds

Stability Analysis for a Dyke Subjected to Tidal Fluctuations (조위변동(潮位變動)을 받는 호안제(護岸堤)의 사면안정해석(斜面安定解析))

  • Kim, Sang Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.8 no.3
    • /
    • pp.91-100
    • /
    • 1988
  • Assuming that tidal level is constantly changed with an amplitude of 10 meters and a cycle of 12 hours, the slope stability for a typical dyke is analysed. The variation of pore water pressure within the dyke during the tidal change is obtained using a computer program, FLUMP, which is incorporated with saturated-unsaturated and transient flow. The results show that the variation of free water surface and distribution of pore water pressure within the dyke during the tidal fluctuations can be clearly predicted with the computer program. When a tide is lowered to the minimum level, the predicted pressure head is higher than the level of the free water surface in some parts of the dyke; that is, excess pore water pressure is generated in a zone affected by the tidal change. Also an unsaturated zone which shows negative pore water pressure is temporally created when a tide is lowered. The shear strength of the zone can be predicted based on the proposal suggested by Fredlund et al. It is emphasized that the excess pore water pressure generated during tidal fluctuations and strength parameters for the unsaturated zone should be considered in analyzing the slope stability of dykes. When those are considered, the critical slip surface seems to be located below the free water surface obtained when a tide is at the lowest.

  • PDF

Tertiary Treatment of Municipal Wastewater Using Unsaturated Sandy Soil (불포화 사질토양을 이용한 도시하수의 3차 처리)

  • Kim, Seung-Hyun;Chung, Jong-Bae;Ha, Hyun-Soo;Prasher, Shiv O.
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.2
    • /
    • pp.111-117
    • /
    • 2003
  • Treatment of secondary effluent was investigated using sandy soil as a possible alternative to the tertiary treatment of municipal wastewater. Secondary effluent was applied with three different flow rates to the surface of pilot scaled lysimeters, which were filled with sandy soil. Some of the lysimeters were covered with osd, while others were kept bare in order to investigate the role of plantation on the treatment. The concentration changes in COD and nitrogen were measured along the unsaturated soil depth. The same set of experiment as with the secondary effluent was performed using tap water to investigate the dissolution of the contaminants from the soil. from the results it was found that when sandy soil was used for tertiary treatment of municipal wastewater COD removal efficiency reached about 70% regardless of the application rate. The soil depth needed to obtain such efficiency increased along with the application rate, which was about 60 cm at the application rate of 50 L/day. Results also showed that nitrification occurred rapidly. The process was completed in soil depth of first $10{\sim}20\;cm$. Nitrogen removal efficiency was as low as about 20% regardless of the application rate. Some supplementary means should be considered to improve the efficiency. Sod on the soil surface had no significant influence on the contaminant treatment but was helpful to keep the infiltration rate undiminished. Finally, the organic soil was found to release significant amount of contaminants when it was in contact with soil water.

Predicting Rainfall Infiltration-Groundwater Flow Based on GIS for a Landslide Analysis (산사태해석을 위한 GIS기반의 강우침투-지하수흐름 예측 기법 제안)

  • Kim, Jung-Hwan;Jeong, Sang-Seom;Bae, Deg-Hyo
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.7
    • /
    • pp.75-89
    • /
    • 2013
  • This paper describes a GIS-based geohydrologic methodology, called YSGWF (YonSei GroundWater Flow) for predicting the rainfall infiltration-groundwater flow of slopes. This physical-based model was developed by the combination of modified Green-Ampt model that considers the unsaturated soil parameters and GIS-based raster model using Darcy's law that reflects the groundwater flow. In the model, raster data are used to simulate the three dimensional inclination of bedrock surface as actual topographic data, and the groundwater flow is governed by the slope. Also, soil profile is ideally subdivided into three zones, i.e., the wetting band zone, partially saturated zone, and fully saturated zone. In the wetting band and partially saturated zones the vertical infiltration of water (rainfall) from surface into ground is modeled. When the infiltrated water recharges into the fully saturated zone, the horizontal flow of groundwater is introduced. A comparison between the numerical calculation and real landslide data shows a reasonable agreement, which indicate that the model can be used to simulate real rainfall infiltration-groundwater flow.

Numerical Modeling of Water Transfer among Precipitation, Surface Water, Soil Moisture and Groundwater

  • Chen, Xi;Zhang, Zhicai;Chen, Yongqin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.2-11
    • /
    • 2006
  • In the processes of hydrological cycle, when precipitation reaches the ground surface, water may become surface runoff or infiltrate into soil and then possibly further percolate into groundwater aquifer. A part of the water is returned to the atmosphere through evaporation and transpiration. Soil moisture dynamics driven climate fluctuations plays a key role in the simulation of water transfer among ground surface, unsaturated zone and aquifer. In this study, a one-layer canopy and a four-layer soil representation is used for a coupled soil-vegetation modeling scheme. A non-zero hydraulic diffusivity between the deepest soil layer modeled and groundwater table is used to couple the numerical equations of soil moisture and groundwater dynamics. Simulation of runoff generation is based on the mechanism of both infiltration excess overland flow and saturation overland flow nested in a numerical model of soil moisture dynamics. Thus, a comprehensive hydrological model integrating canopy, soil zone and aquifer has been developed to evaluate water resources in the plain region of Huaihe River basin in East China and simulate water transfer among precipitation, surface water, soil moisture and groundwater. The newly developed model is capable of calculating hydrological components of surface runoff, evapotranpiration from soil and aquifer, and groundwater recharge from precipitation and discharge into rivers. Regional parameterization is made by using two approaches. One is to determine most parameters representing specific physical values on the basis of characterization of soil properties in unsaturated zone and aquifer, and vegetations. The other is to calibrate the remaining few parameters on the basis of comparison between measured and simulated streamflow and groundwater tables. The integrated modeling system was successfully used in the Linhuanji catchment of Huaihe plain region. Study results demonstrate that (1) on the average 14.2% of precipitation becomes surface runoff and baseflow during a ten-year period from 1986 to 1995 and this figure fluctuates between only 3.0% in drought years of 1986, 1988, 1993 and 1994 to 24.0% in wet year of 1991; (2) groundwater directly deriving from precipitation recharge is about 15.0% t of the precipitation amount, and (3) about half of the groundwater recharge flows into rivers and loses through evaporation.

  • PDF

Effects of Hydrological Condition on the Coupled Thermal-Hydrological-Mechanical Behavior of Rock Mass Surrounding Cavern Thermal Energy Storage (암반 공동 열에너지저장소 주변 암반의 수리적 조건에 따른 열-수리-역학적 연계거동 분석)

  • Park, Jung-Wook;Rutqvist, Jonny;Lee, Hang Bok;Ryu, Dongwoo;Synn, Joong-Ho;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.25 no.2
    • /
    • pp.168-185
    • /
    • 2015
  • The thermal-hydrological-mechanical (T-H-M) behavior of rock mass surrounding a large-scale high-temperature cavern thermal energy storage (CTES) at a shallow depth has been investigated, and the effects of hydrological conditions such as water table and rock permeability on the behavior have been examined. The liquid saturation of ground water around a storage cavern may have a small impact on the overall heat transfer and mechanical behavior of surrounding rock mass for a relatively low rock permeability of $10^{-17}m^2$. In terms of the distributions of temperature, stress and displacement of the surrounding rock mass, the results expected from the simulation with the cavern below the water table were almost identical to that obtained from the simulation with the cavern in the unsaturated zone. The heat transfer in the rock mass with reasonable permeability ${\leq}10^{-15}m^2$ was dominated by the conduction. In the simulation with rock permeability of $10^{-12}m^2$, however, the convective heat transfer by ground-water was dominant, accompanying the upward heat flow to near-ground surface. The temperature and pressure around a storage cavern showed different distributions according to the rock permeability, as a result of the complex coupled processes such as the heat transfer by multi-phase flow and the evaporation of ground-water.

Study on Characteristics of Transient Soulte Transport in the Vadose Zone by Using TDR: (2) Application (TDR(Time Domain Reflectometry)를 이용한 비포화 토양에서 천이상태의 오염원 이송확산 특성에 관한 연구 : (2) 적용)

  • Park, Jae-Hyeon;Seo, Il-Won
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.6
    • /
    • pp.751-762
    • /
    • 1999
  • In this study, a 1-D laboratory experiment was conducted to investigate the characteristics of transient unsaturated solute transport by using two kinds of soils of which properties were known by test. Especially the TDR method which is proposed in this study was used to measure water content and solute concentration. As results, in the transient flow, the wetting front moves down rapidly, and the distribution of solute concentration near the wetting front showed the similar type of the water content distribution(semi-bell type). A numerical model HYDRUS was used to compare with the experimental results. Numerical results for the water movement are similar to experimental result. However, numerical results of the distribution of solute concentration are more scattered than experimental results. It means that measured dispersivity, numerical dispersion, adsorption coefficient, and soil sample size etc. should be considered in order to determine the dispersivity used in the numerical model. The present measuring method was proved to be superior to other formula and to be an available method to apply to solute transport test. The measuring error of the developed method is estimated smaller than 10% while water content is larger than 0.15.

  • PDF

Variation of Flow and Filtration Mechanisms in an Infiltration Trench Treating Highway Stormwater Runoff (고속도로 강우유출수 처리를 위한 침투도랑에서 흐름조건에 따른 여과기작 및 효율분석)

  • Guerra, Heidi B.;Yu, Jianghua;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.20 no.1
    • /
    • pp.63-71
    • /
    • 2018
  • The particle filtration mechanisms in an infiltration trench should be varying due to the different hydraulic conditions during stormwater runoff. The understanding of these variations associated with different filtration mechanisms and their effect on the particle removal efficiency is of vital importance. Therefore, a LID (Low Impact Development) system comprising of an infiltration trench packed with gravel and woodchip was investigated during the monitoring of several independent rainfall events. A typical rainfall event was divided into separate regimes and their corresponding flow conditions as well as filtration mechanisms in the trench were analyzed. According to hydraulic conditions, it was found out that filtration changes between vertical and horizontal flows as well as between unsaturated, saturated, and partially-saturated flows. Particle separation efficiency was high (55-76%) and was mainly governed by physical straining during the unsaturated period. It was then enhanced by diffusion during the saturated period (75-95%). When the trench became partially saturated at the end of the rainfall event, the efficiency decreased which was believed to be due to the existence of a negatively charged air-water interface which limited the removal to positively charged particles.

Measurement of Soil Water Content by Time Domain Reflectometry (TDR(Time Domain Reflectometry)을 이용한 토양함수량의 측정)

  • Park, Jae-Hyeon;Yun, Seong-Yong;Kim, Sang-Jun
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.6
    • /
    • pp.587-595
    • /
    • 1997
  • Experimental study on unsaturated flow in the soil is important to understand the characteristics of the water flow. Measurement of unsteady-state water movement using the traditional equipment (e.g. tensiometer) has a problem that requires relatively a long response time. In this study a quick measurement method of soil water flow using TDR is introduced. TDR consists of an electronic function generator which generates a squared wave, and an oscilloscope which catches the reflected wave. The wave is reflected where both the impedance of the transmission line and the propagation velocity are changed. The water content can be obtained from the travel time measured by means of TDR because the dielectric constant is affected by the change of soil water content. From the result of TDR calibration. TDR measurement error for the oven dried soil was found to be less than 3.5%. This supports that TDR is a viable technique to measure the unsteady-state water movement.

  • PDF

A Study of Theoretical Method and Application to Laboratory Tests for Three-dimensional Transient Seepage Analysis (삼차원(三次元) 침투류해석(浸透流解析)을 위한 이론적(理論的) 방법(方法)과 실험적용예(實驗適用例)에 관(關)한 고찰(考察))

  • Jin, Byung Ik;Kim, Jae Hong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.2
    • /
    • pp.13-24
    • /
    • 1984
  • The main part of this thesis deals with a three-dimensional transient seepage flow, discussing its fundamental conception into Which the mathematical analysis was introduced based upon the finite element method, propriety of geometrical analysis and flow movement of seepage water. As is commented in the body of the report, the saturated-unsaturated method with respect to the free water surface method is revealed to have the relative merits and demerits. Generally, the unknown sections in the form of free water surface matters in case that tunnels or pores appear. On the other hand, the applicable range is quite large and variable to the methods accordingly. Also, an example as to the seepage analysis in the rock bed section is described. An unfavorable time-consuming problem is inevitale because the complicated and widely multifarious joints and faults are responsible for the intensity of seepage flow.

  • PDF

Simulation of Unsaturated Fluid Flow on the 2nd Phase Facility at the Wolsong LILW Disposal Center (경주 중저준위방폐장 2단계 처분시설의 불포화 환경하에서 침투수 유동 해석)

  • Ha, Jaechul;Lee, Jeonghwan;Yoon, Jeonghyoun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.3
    • /
    • pp.219-230
    • /
    • 2017
  • This study was conducted to predict and evaluate the uncertainty of safety after closure of the second phase surface disposal facility of the Gyeongju intermediate and low level repository in Korea. In this study, four scenarios are developed considering both intact and degraded states of multi-layered covers and disposal containers; also, the fluid flow by a rainfall into the disposal facility is simulated. The rainfall conditions are implemented based on the monthly average data of the past 30 years (1985~2014); the simulation period is 300 years, the management period regulated by institutional provisions. As a result of the evaluation of the basic scenario, in which the integrity of both of the containers and the covers is maintained, it was confirmed that penetration of rainfall does not completely saturate the inside of the disposal facility. It is revealed that the multiple cover layers and concrete containers effectively play the role of barrier against the permeation of rainfall.