• Title/Summary/Keyword: University Factor

Search Result 41,798, Processing Time 0.065 seconds

Exploring the effects of speed and scale on a ship's form factor using CFD

  • Terziev, Momchil;Tezdogan, Tahsin;Demirel, Yigit Kemal;Villa, Diego;Mizzi, Simon;Incecik, Atilla
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.147-162
    • /
    • 2021
  • The problem of predicting a ship's form factor and associated scale effects has been subject to many investigations in recent years. In this study, an attempt is made to investigate whether the form factor is influenced by a change in the ship's speed by numerically modelling a geosim series of the KCS hull form by means of a RANS solver. The turbulence dependence of the problem is also studied by altering the closure model among three widely used approaches (the k-𝜔, k-𝜔 SST, and k-𝜀 models). The results show that at very low speeds (Froude numbers in the range of 0.02-0.06) the numerical model predicts changes in the form factor of a ship between 10% and 20%, depending on the turbulence model and scale factor choices. As the speed is increased further, the form factor exhibits little change, usually in the range of 1% or less. Simulations where the Reynolds number is changed by approximately two orders of magnitude, achieved by altering the value of viscosity, confirmed that the form factor can be considered Froude-dependent only for low speeds, predicting essentially identical values when high speed cases are considered.

What's the consideration attribute on purchasing the HMR? (가정식가 대용식(HMR) 선택 속성 분석)

  • Chung, Ra-Na;Yang, Il-Sun;Lee, Hae-Young
    • Journal of the Korean Society of Food Culture
    • /
    • v.22 no.3
    • /
    • pp.315-322
    • /
    • 2007
  • The purpose of this study was to analyze the factors consumers seriously considered when purchasing HMRs and the difference among the factors according to their demographic characteristics. The subjects were adults in their twenties or older who had used HMRs and lived in Seoul and Gyeonggi Province in Korea. Random sampling picked 550 of them, who were distributed a questionnaire from March 12 to 30, 2005. Total 451 questionnaires were returned(the return rates were 82%). The validity of the 27 features was examined by factor analysis. There were seven factors identified, and they were labeled considering the meaning of their items as follows: 'Factor 1. food quality,' 'Factor 2. appearance and packaging,' 'Factor 3. convenience and reliability,' 'Factor 4. access,' 'Factor 5. familiarity,' 'Factor 6. positive experiences,' and 'Factor 7. practicality.

Satisfaction and Dissatisfaction Factors on Rural Tourism, Focused on rural tourists visiting Buraemi community (CIT를 이용한 농촌관광의 만족.불만족 요인에 관한 연구 -부래미 마을 방문객을 중심으로-)

  • Ryu, Si-Young;Um, Seo-Ho
    • Journal of Korean Society of Rural Planning
    • /
    • v.14 no.3
    • /
    • pp.11-17
    • /
    • 2008
  • Drawing on Herzberg's two-factor theory, this article suggests that visitors to rural tourism base their overall evaluation with an experience on their consideration of two types of aspects referred to as either 'motivators' and 'hygienes' by using the critical incident technique. 233 critical incidents described by 121 participants are categorized into three exclusive factors which are named as experiential factor, cognitive factor, and affective factor. The application of Herzberg's two-factor theory to rural tourism suggests 'satisfiers' to come from the experience-activity itself, experiential factor. While more peripheral elements constitute 'dissatisfiers', cognitive factor. The paper provides the advancement and broad application of Herzberg's theory to further understand rural tourists satisfaction.

An Analysis of Infertility Patients (불임증(不姙症) 환자(患者)의 통계적(統計的) 고찰(考察);서울대학교병원(大學校病院) 불임상담실(不姙相談室) 1872 예(例)의 분석(分析))

  • Chang, Y.S.;Lee, J.Y.;Moon, S.Y.;Kim, J.K.;Choi, S.H.;Lim, Y.T.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.12 no.1
    • /
    • pp.47-70
    • /
    • 1985
  • This study was presented of the 1,872 cases of infertile couples who visited and examined at the sterility clinic of Department of Obstetrics & Gynecology, Seoul National University Hospital from Sept., 1980 to Dec., 1983. Age, duration of infertility, past medical history, and other general factors were analyzed, and the factors responsible for infertility were classified and discussed. Mode of treatment, outcome of pregnancy, pregnancy rate responsible for each factor were also presented. The results were as follows: 1) The infertility was primary in 1,128, or 60.3% and secondary in 744, or 39.7%. 2) The age between 26 and 30 years of age comprised about one half of the total patients. 3) The duration of infertility between 1 and 4 years comprised about three quarters of the total patients, and the mean duration was 3.8 years. 4) The most common medical history in primary infertility was tuberculous disease, and that in secondary infertility was history of previous laparotomy. 5) About two thirds of antecedent pregnancies were abortion. 6) The major etiologic factor of infertility were male factor in 12.3%, tubal factor in 38.8%, ovulatory failure in 25.4%, uterine factor in 8.8%, cervical factor in 5.2%, peritoneal factor in 9.5%, and no demonstrable cause in 11.3%. 7) The types of male factor were azoospermia in 61.6%, oligospermia in 25.8%, low motility in 11.6%, and other abnormality in 1.0%. 8) The types of ovulatory failure were ovarian failure in 7.4%, hypothalamo-pituitary failure in 8.1 %, hypothalamo-pituitary dysfunction (including Polycystic ovarian syndrome) in 30.2%, and hyperprolactinemia in 22.4%. 9) The types of uterine factor were endometrial tuberculosis in 27.5%, uterine synechia in 33.8%, uterine anomaly in 19.7%, myoma and polyp in 9.1 %, and luteal phase defect in 9.9%. 10) The types of peritoneal factor were pelvic adhesion in 80.9% and endometriosis in 19.6%. 11) Surgeries were done in 408 patients, and they were salpingolysis, lysis of extraadnexal adhesion, salpingostomy, fimbrioplasty, ovarian wedge resection for polycystic ovarian disease, tubo-tubal anastomosis, and tubo-uterine implantation in orders. 12) 243 pregnancies were achieved during the infertility work-up, of which livebirth was 46.5%, ectopic pregnancy was 7.4%, spontaneous abortion was 7.8%, and on-going pregnancy or lost to follow-up was 36.2%. 13) Pregnancy rates in various factors were male factor in 18.7%, ovulatory factor in 31.7%, tubal factor in 24.2%, uterine factor in 34.6%, cervical factor in 19.0%, peritoneal factor in 29.0%, combined factors in 10.5%, and unexplained infertility in 37.1%. Pregnancy rate in whole patients was 25.2%.

  • PDF

A Study on the Body Types of the Chinese Women (I) -Focusing on Beijing and Shanghai- (중국 성인 여성의 체형 연구(I) -북경과 상해에 거주하는 여성을 중심으로-)

  • Lim, Soon;Sohn, Hee-Soon;Seok, Hye-Jung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.7
    • /
    • pp.831-842
    • /
    • 2003
  • The purpose of this study is to analyze body types of Chinese women and provide concrete information on it by classifying them into several representative groups. As for the method of this study, statistical analysis is made of 79 items. This is done from July 18 to Aug 07, 2002, 525 female subjects from age 20 to 49 participated in this study. They all live in Beijing and Shanghai in China. The results of this study are as follows. 1. Means, standard deviations, the maximum and minimum of 19 items are extracted. The height and girth item have a high standard deviations. 2. 8 factors are extracted by using factor analysis. Factor 1: body obesity, Factor 2: vertical body size, Factor 3: upper body length Factor 4: size of ankles, Factor 5: angle of shoulders, Factor 6: length of hip Factor 7: size of shoulder, Factor 8: shape of chest 3. The body types of Chinese women are classified into 5 sub groups from the result of the Cluster analysis.

Power Factor improvement of Power Conversion Equipment for High Pressure Sodium Lamps (고압 나트륨 램프 구동용 전력변환장치의 역률 개선)

  • Lee, S.H.;Suh, K.Y.;Lee, H.W.;Lee, S.H.;Mun, S.P.
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.147-150
    • /
    • 2002
  • HPSL(High Pressure Sodium lamp)have attracted much attention in recent years, because they offer high luminous efficiency and very long life. Recently, AC-DC converters have been widely as power factor improvement circuits in the power conversion equipment An application of the ZVT-PWM(Zero Voltage Transition Pulse Width Modulation) boost converter, which has great advantage on miniaturization and high power density, to the power factor improvement circuit of the HPSL inverter are described to identify the power factor correction characteristics of the inverter. In this paper the series-parallel resonant inverter(electronic ballast) for driving a HPS lamp is discussed. Finally, a power factor corrector is cascaded in front of the electronic ballast. Consequently, a high power factor above 0.99 and low THD on the line current can be achieved.

  • PDF

Development of advanced Power Factor Computation Algorithm in Harmonics distorted Distribution System (고조파 왜곡 환경에서 향상된 역률 계측 알고리즘 개발)

  • Lee, Hyun-woo;Park, Young-kyun;Lee, Jinhan;Joung, Sanghyun;Park, Chul-woo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.7
    • /
    • pp.121-127
    • /
    • 2016
  • We propose a algorithm to calculate power factor of fundamental waveform in an environment where the voltage and current have been distorted by harmonics. In the proposed power factor computation algorithm, voltage and current are converted to rotating DQ reference frame, and power factor is calculated from active power and reactive power. We compare the proposed method with the conventional power factor measurement method as mathematically. In a condition that voltage and current are distorted by harmonics, the proposed method accurately measure the power factor of fundamental wave, and it is confirmed by simulation using MATLAB. If the proposed power factor measurement method is applied to an automatic power factor control system, a power factor compensation performance can be maximized in harmonic distortion environment. As a result, it is possible to reduce electricity prices, reduce line loss, increase load capacity, ensure the transmission margin capacity, and reduce the amount of power generation.

Factor Structure of the Beck Depression Inventory in Anxiety Disorder (불안 장애에서 벡우울척도의 요인구조)

  • Yang, Hyun-Joo;Kim, Dae-Ho;Jang, Eun-Young;Han, Chang-Woo;Park, Yong-Chon
    • Anxiety and mood
    • /
    • v.7 no.1
    • /
    • pp.16-21
    • /
    • 2011
  • Objective : Depressive symptoms often coexist with other anxiety disorder symptoms. Furthermore, an anxiety disorder that is comorbid with a depressive disorder results in more severe symptoms and a poorer outcome prognosis. To understand the construct of depressive symptoms in anxiety disorder, this study investigated the factor structure of the Beck Depression Inventory among outpatients with anxiety disorders. Methods : All data were from psychiatric department outpatients at a university-affiliated hospital. We conducted a principal component analysis using data from 194 outpatients with DSM-IV anxiety disorders and calculated goodness-of-fit-indices. Results : Exploratory factor analysis revealed a four factor structure--Cognitive-affective symptoms (Factor 1), Somatic symptoms (Factor 2), Self-reproach (Factor 3), and Hypochondriasis/indecisiveness (Factor 4)--and a 57% total variance. This four-factor model demonstrated an acceptable level of model fit, and it fit better than did a three-factor solution from the literature on depressive disorder. Conclusion : This study's results suggest a difference in the construct of self-reported depressive symptoms in anxiety disorders. These findings also support a dimensional approach to studying anxiety and depression. Further studies may benefit from including comorbid depressive disorder and its influence on anxiety disorders.

A Study on The Relationship Among Motivation Factor, Hygiene Factor and Job Satisfaction of School Meal Chefs

  • Cho, Yoon-Shik;Lee, Mi-Ock
    • Journal of the Korean Data and Information Science Society
    • /
    • v.17 no.4
    • /
    • pp.1119-1127
    • /
    • 2006
  • The purpose of this study is to identify relationship among motivation factor, hygiene factor, and job satisfaction of school meal chefs. The respondents included 155 school meal chefs in the survey. Data was analyzed by confirmatory factor analysis and cause-effect analysis among the constructs. After research model testing, the following results was obtained : hygiene factor was influenced directly and positively by the job satisfaction of school meal chefs. But motivation factor was not influenced directly and positively by the job satisfaction of school meal chefs.

  • PDF

A Study on Enhancing the Load Power Factor from the Point of View of Economic Operation Using the Load Power Factor Sensitivity Method (부하역률 감도기법 적용에 의한 전력시스템의 경제운용 측면에서의 역률개선 방안 연구)

  • Lee B. H.;Kim J. H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.153-155
    • /
    • 2004
  • Various problems such as the increase of the power loss and the voltage instability may often occur in the case of low load power factor. The demand of reactive power increases continuously with the growth of active power and the restructuring of electric power companies makes the integrated management of ractive power a troublesome problem, so that the systematic control of load power factor is required. In this paper, the load power factor sensitivity of the generation cost is used for determining the locations of reactive power compensation devices effectively and for enhancing the load power factor appropriately. In addition, the integrated costs are used for determining the value of the load power factor from the point of view of the economic operation. It is shown through the application to a large-scale power system that the system power factor can be enhanced effectively and appropriately using the load power factor sensitivity and integrated costs.

  • PDF