• 제목/요약/키워드: Universal testing machine

검색결과 790건 처리시간 0.025초

피로시험용 프로그램 개발에 관한 연구 (A Study on the Program Development of Fatigue Test)

  • 이종선
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.275-280
    • /
    • 1999
  • This study is object to program development of fatigue test for universal testing machine. Fatigue program is consist of test simulation, data analysis and print report by control fatigue testing program which expansively applies tension-compression tests with using oil pressure mechanism by Visual Basic software running under windows 98.

  • PDF

Experimental characterization of a smart material via DIC

  • Casciati, Sara;Bortoluzzi, Daniele;Faravelli, Lucia;Rosadini, Luca
    • Smart Structures and Systems
    • /
    • 제30권3호
    • /
    • pp.255-261
    • /
    • 2022
  • When no extensometer is available in a generic tensile-compression test carried out by a universal testing machine (for instance the model BIONIX from Material Testing Systems (MTS)), the test results only provide the relative displacement between the machine grips. The test does not provide any information on the local behaviour of the material. This contribution presents the potential of an application of Digital Image Correlation (DIC) toward the reconstruction of the behaviour along the specimen. In particular, the authors test a Ni-Ti shape memory alloys (SMA) specimen with emphasis on the coupling of the two measurement techniques.

바이몰프형 PZT를 이용한 소형만능재료시험기용 정밀 구동 액추에이터의 개발 (Development of a New Precision Actuator by Bi-morph Type PZT to Realize Nano/Micro Mechanical Testing in MUTM)

  • 권현규;최성대;정선환
    • 한국기계가공학회지
    • /
    • 제5권1호
    • /
    • pp.45-50
    • /
    • 2006
  • This paper shows a new precision actuator of MUTM(miniature universal testing machine) for the testing of compression and tensile load on the MEMS materials and structures. The MUTM consists of a sample holder, an ultraprecision precision actuator(tranlation stage) and load sensor. The precision actuator has been developed for generating displacements with nanometer accuracy and a dynamic range of 1mm simultaneously. In this paper, it can be made by using the displacement property of bi-morph type PZT, which is able to extend the long range(stroke) according to cantilever size. However, it is not enough to be generated for compression and tensile load in miniature universal testing machine. Therefore, three dozen bi-morph type PZTs are used for generating the load. The load and displacement of the precision actuator are 35g and 0.4mm respectively.

  • PDF

Numerical simulation of compressive to tensile load conversion for determining the tensile strength of ultra-high performance concrete

  • Haeri, Hadi;Mirshekari, Nader;Sarfarazi, Vahab;Marji, Mohammad Fatehi
    • Smart Structures and Systems
    • /
    • 제26권5호
    • /
    • pp.605-617
    • /
    • 2020
  • In this study, the experimental tests for the direct tensile strength measurement of Ultra-High Performance Concrete (UHPC) were numerically modeled by using the discrete element method (circle type element) and Finite Element Method (FEM). The experimental tests used for the laboratory tensile strength measurement is the Compressive-to-Tensile Load Conversion (CTLC) device. In this paper, the failure process including the cracks initiation, propagation and coalescence studied and then the direct tensile strength of the UHPC specimens measured by the novel apparatus i.e., CTLC device. For this purpose, the UHPC member (each containing a central hole) prepared, and situated in the CTLC device which in turn placed in the universal testing machine. The direct tensile strength of the member is measured due to the direct tensile stress which is applied to this specimen by the CTLC device. This novel device transferring the applied compressive load to that of the tensile during the testing process. The UHPC beam specimen of size 150 × 60 × 190 mm and internal hole of 75 × 60 mm was used in this study. The rate of the applied compressive load to CTLC device through the universal testing machine was 0.02 MPa/s. The direct tensile strength of UHPC was found using a new formula based on the present analyses. The numerical simulation given in this study gives the tensile strength and failure behavior of the UHPC very close to those obtained experimentally by the CTLC device implemented in the universal testing machine. The percent variation between experimental results and numerical results was found as nearly 2%. PFC2D simulations of the direct tensile strength measuring specimen and ABAQUS simulation of the tested CTLC specimens both demonstrate the validity and capability of the proposed testing procedure for the direct tensile strength measurement of UHPC specimens.

두부의 주조 및 질감 특성에 미치는 지방의 영향 (Effect of Fat on the Structural and Textural Properties of Soybeam Curd)

  • 윤영미;손경희
    • 한국식품조리과학회지
    • /
    • 제1권1호
    • /
    • pp.57-64
    • /
    • 1985
  • This study was conducted to investigate the effect of fat on structure and texture of soybean curds by partial or whole replacement of soybean with defatted soy flour, The textural properties of soybean curd were examined by Instron universal testing machine, and the microscopic structure of soybean curds was examined by Scanning electron microscope(SEM). The results obtained were as follows ; 1. Textural parameters determined by Instron universal testing machine showed that hardness and gumminess of soybean curs were significantly increased as the fat contents of the samples decreased. On the while, springiness of the samples were significantly lowered as the fat content decreased. 2. Microscopic structure of soybean curds examined by SME demonstrated that samples with high fat had more fat globules and thinner network layer which were assumed to surround moisture with.

  • PDF

병렬 운동 기구의 미끄럼 볼 조인트 개발에 관한 연구 (A Study on the Sliding Ball Joint of Parallel Kinematic Mechanism)

  • 유대원;이재학
    • 대한기계학회논문집A
    • /
    • 제33권9호
    • /
    • pp.982-989
    • /
    • 2009
  • Parallel Kinematic Mechanism (PKM) is a device to perform the various motion in three-dimensional space and it calls for six degree of freedom. For example, Parallel Kinematic Mechanism is applied to machine tools, medical equipments, MEMS, virtual reality devices and flight motion simulators. Recently, many companies have tried to develop new Parallel Kinematic Mechanism in order to improve the cycle time and the precisional tolerance. Parallel Kinematic Mechanism uses general universal joint and spherical joint, but such joints have accumulated tolerance problems. Therefore, it causes position control problem and dramatically life time reduction. This paper focused on the rolling element to improve sliding precision in new sliding ball joint development. Before the final design and production, it was confirmed that new sliding ball joint held a higher load and a good geometrical structure. FEM analysis showed a favorable agreement with tensile and compressive testing results by universal testing machine. In conclusions, a new sliding ball joint has been developed to solve a problem of accumulated tolerance and verified using tensile and compressive testing as well as FEM analysis.

소형 재료시험기의 모델링 및 진동 제어 (Modeling and Vibration Control of the Miniature Universal Testing Machine)

  • 복진;김영식;권현규;김인수;최성대
    • 한국소음진동공학회논문집
    • /
    • 제15권3호
    • /
    • pp.290-296
    • /
    • 2005
  • This paper proposes the modeling scheme of the Miniature Universal Testing Machine (MUTM) composed of 36 thin-beam-type bimorph PZTs and the control algorithm to minimize the residual vibration of the MUTM in the dynamic testing of specimens. In the operation of the MUTM, hysteresis, residual displacement and vibration of it are major issues. From the analysis of the MUTM behaviors, the hysteresis is described by the curving fitting scheme with the function of an input voltage. The dynamic characteristics of the MUTM are identified by the frequency domain modeling technique based on the experimental data. The interested bandwidth is focused on 125-315HZ for effective modeling and control. For the robust vibration control of the MUTM, the sliding mode control and the Kalman filter as observer are proposed. The paper also proposes the best input signal type to operate the MUTM effectively. The feasibility of the proposed modeling scheme and control algorithm are tested and verified experimentally.

소형 재료시험기의 모델링 및 진동 제어 (Modeling and Vibration Control of the Miniature Universal Testing Machine)

  • 복진;김영식;권현규;김인수;최성대
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.476-481
    • /
    • 2004
  • This paper proposes the modeling scheme of the Miniature Universal Testing Machine (MUTM) composed of 36 thin-beam-type bimorph PZTs and the control algorithm to minimize the residual vibration of the MUTM in the dynamic testing of specimens. In the operation of the MUTM, hysteresis, residual displacement and vibration of it are major issues. From the analysis of the MUTM behaviors, the hysteresis is described by the curving fitting scheme with the function of an input voltage. The dynamic characteristics of the MUTM are identified by the frequency domain modeling technique base on the experimental data. The interest bandwidth is focused on 125-315HZ for effective modeling and control. For the robust vibration control of the MUTM, the sliding mode control and the Kalman filter as observer are proposed. The paper also proposes the best input signal type to operate the MUTM effectively. The feasibility of the proposed modeling scheme and control algorithm are tested and verified experimentally.

  • PDF